Laserfiche WebLink
E LECTR I CAL SY M • oLs & ABBREVIATIONS FIXTURE SCHEDULE i 0 <br /> FS1 FLUORESCENT SURFACE MOUNTED ACRYLIC WRAPAROUND FIXTURE, 1. THE CONTRACTOR SHALL NOT SCALE ELECTRICAL DRAWINGS. REFER <br /> HEAVY GAUGE STEEL HOUSING, 100% CLEAR ACRYLIC PRISMATIC TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS. <br /> DIFFUSER, ENERGY SAVING BALLAST. METALUX W332A SERIES, <br /> DAY-BRITE, LITHONIA OR APPROVED. LAMPS;3-F32/T8/3500K. 2. BEFORE SUBMITTING A BID, THE CONTRACTOR MUST VISIT THE SITE <br /> AND REVIEW THE CONDITIONS THAT AFFECT THE WORK SHOWN. THE <br /> FS2 FLUORESCENT SURFACE MOUNTED ACRYLIC WRAPAROUND FIXTURE, EXISTING CONDITIONS ARE BASED ON DRAWINGS BY OTHERS AND <br /> HEAVY GAUGE STEEL HOUSING, 100% CLEAR ACRYLIC PRISMATIC CASUAL FIELD OBSERVATION. ALTHOUGH THIS INFORMATION IS <br /> GENERAL COMMUNICATIONS DIFFUSER, ENERGY SAVING BALLAST. METALUX W232A SERIES, BELIEVED TO BE RELIABLE, THE ENGINEER IS NOT RESPONSIBLE FOR <br /> DAY-BRITE, LITHONIA OR APPROVED. LAMPS;2-F32/T8/3500K. ITS ACCURACY. <br /> ® INDICATES NOTES THIS SHEET. 1► TELEPHONE OUTLET FS3 INCANDESCENT SURFACE MOUNTED FIXTURE, WHITE CANOPY, 12" 3. ALL 120 VOLT, SINGLE PHASE, RECEPTACLES TO SERVE KITCHEN <br /> SQUARE WHITE GLASS DIFFUSER, WHITE FINISH. SEA GULL COUNTER TOP SURFACES AND BATHROOMS SHALL HAVE GROUND FAULT <br /> AN REFERENCE TARGET, UPPER HALF INDICATES DETAIL'S D COMPUTER OUTLET LIGHTING 7452-15 SERIES, PROGRESS, TIMELY OR APPROVED. INTERRUPTER PROTECTION FOR PERSONNEL. <br /> Ur NUMBER, LOWER HALF INDICATES DETAIL'S SHEET NO. LAMPS;2-60W A19. <br /> TELEVISION OUTLET. 4. ALL COUNTERTOP RECEPTACLES LOCATED IN THE KITCHEN AND <br /> FS4 FLUORESCENT STRIP FIXTURE, TWO LAMPS IN CROSS SECTION, BATHROOMS SHALL BE MOUNTED ABOVE THE BACKSPLASH UNLESS NOTED <br /> P-31 PROVIDE AN INDIVIDUAL 'HOME RUN' FROM THIS BAKED WHITE ENAMEL FINISH. METALUX STN-232 SERIES, DAY- OTHERWISE. <br /> 7 LOCATION TO THE PANEL AND CIRCUIT DESIGNATION BRITE, LITHONIA OR APPROVED. LAMPS;2-F32/T8/3500K. <br /> INDICATED (i.e. PANEL 'P', CIRCUIT #31). 5. CONTRACTOR IS RESPONSIBLE FOR CORE DRILLING, CUTTING, <br /> UNLESS OTHERWISE INDICATED ALL CONDUIT SHALL BE IW1 INCANDESCENT WALL MOUNTED FIXTURE, WET LABELED, WHITE PATCHING, FIRE STOPPING, ETC. AS REQUIRED. <br /> SIZED PER N.E.C. BY THE ELECTRICAL CONTRACTOR POLYCARBONATE GLOBE DIFFUSER, SATIN ALUMINUM FINISH. <br /> FIRE ALARM PROGRESS P5697-16 OR APPROVED. LAMPS;1�-60W A19. 6. ALIGN ALL LIGHTING FIXTURES WITH SMOKE DETECTORS, EXHAUST <br /> SWITCH - SINGLE POLE (SUBSCRIPTS a,b, etc., FANS, ETC. FOR A "CLEAN" CEILING LAYOUT. <br /> $(o) DENOTES FIXTURE CONTROLLED) IW2 INCANDESCENT WALL MOUNTED FIXTURE, WHITE TEXTURED <br /> CHANNEL GLASS DIFFUSER, 13" IN WIDTH, 4 1/4" HEIGHT. 7. THE CONTRACTOR SHALL PROVIDE ALL TRENCHING, BACKFILL, <br /> PROCESS P3015-30 OR APPROVED. LAMPS;2-60W A19. EXCAVATION, SAW CUTTING AND PATCHING UNLESS NOTED OTHERWISE. <br /> $3 3 WAY SWITCH SMOKE DETECTOR, 120 VOLT SINGLE STATION <br /> ® IS1 INCANDESCENT SURFACE MOUNTED DRUM FIXTURE, 9 1/2" 8. THE CONTRACTOR SHALL LOCATE ALL UTILITIES PRIOR TO STARTING <br /> 4 4 WAY SWITCH WITH BATTERY BACKUP. DIAMETER, 5 1/4" HEIGHT, WHITE CANOPY, WHITE GLASS ANY EXCAVATION. ANY DAMAGE TO EXISTING UTILITIES SHALL BE <br /> �M MOTOR RATED DISCONNECT SWITCH DIFFUSER. PROGRESS P3410-30 SERIES OR APPROVED. REPAIRED AT THE CONTRACTORS EXPENSE. <br /> CARBON MONOXIDE DETECTOR. MACURCO INC. CM-14A LAMPS;2-60W A19. <br /> - -P- - PRIMARY SERVICE UNDERGROUND U.N.O. ® 9. ELECTRICAL DRAWINGS INDICATE TYPICAL UNIT LAYOUTS. REFER TO <br /> ( SERIES OR APPROVED. PROVIDE POWER CONNECTION GENERAL FIXTURE NOTES; ARCHITECTURAL DRAWINGS FOR QUANTITY AND LOCATION OF UNITS. <br /> - -S- - SECONDARY SERVICE (UNDERGROUND U.N.O.) AND 24 VAC TRANSFORMER, CONNECT COMPLETE. 1. ALL FLUORESCENT BALLASTS SHALL BE ELECTRONIC. 10. ARCHITECTURAL DRAWINGS INDICATE LOCATIONS WHERE PORTIONS OF <br /> - -T- - TELEPHONE SERVICE (UNDERGROUND U.N.O.) MOUNT AT 5'-O" AFF. EXISTING WALLS AND CEILINGS WILL BE REMOVED FOR INSTALLATION <br /> 2. PROVIDE ALL MOUNTING HARDWARE, FLANGES, STEMS, SLOPE OF DEVICES AND WIRING. ELECTRICAL CONTRACTOR SHALL REVIEW <br /> -- -1V- - CABLE TV SERVICE (UNDERGROUND U.N.O.) CEILING ADAPTERS, SWIVEL HANGERS ETC. FOR THE FINAL THIS INFORMATION, AND COORDINATE WITH GENERAL CONTRACTOR <br /> CEILING CONSTRUCTION TYPE. REGARDING EXACT CUT-OUT LOCATIONS AND SIZES REQUIRED. <br /> LIGHTING 11. DURING CONSTRUCTION, THE CONTRACTOR IS RESPONSIBLE FOR <br /> PROVIDING AT LEAST ONE OPERATIONAL 30 AMP CIRCUIT IN EACH <br /> UNIT AT THE END OF EACH WORKING DAY FOR USE BY THE OWNER <br /> MI FFLUORESCENT <br /> O SWITCHING CONTROL).FIX U E, (SUBSCRIPT INDICATES ELECTRIC HEATER SCHEDULE AFTER HOURS AND ON WEEKENDS. <br /> • FLUORESCENT STRIP FIXTURE ABBREVIATIONS <br /> TAG MAKE MODEL WATTS V/PH <br /> Q SURFACE MOUNTED FIXTURE <br /> VI N T <br /> 10 i WALL MOUNTED FLUORESCENT FIXTURE AC ABOVE COUNTER EWH-1 MARKEL E4003 TA-RP 1000 120/1 <br /> AFF ABOVE FINISHED FLOOR 1. BIDDER IS EXPECTED TO VISIT THE SITE OF PROPOSED <br /> WALL MOUNTED FIXTURE CONSTRUCTION TO VERIFY AND INSPECT THE EXISTING SITE TO <br /> AG ABOVE GRADE DETERMINE THE EXTENT OF DEMOLITION WORK. QUANTITY AND <br /> ® RECESSED DOWNLIGHT. LOCATION OF DEVICES ARE APPROXIMATE. CONTRACTOR IS <br /> A,AMP AMPERE RESPONSIBLE FOR VERIFYING EXISTING CONDITIONS AND REMOVING <br /> LIGHT FIXTURE TYPE DESIGNATION MARKEL 4000 SERIES; U.L. LISTED ELECTRIC FAN FORCED TYPE, ALL DEVICES. <br /> �CXX� X = TYPE FIXTURE(SEEAWG AMERICAN WIRE GAUGE REGISTERED GRILLE, ROMOTE WALL MOUNTED THERMOSTAT, <br /> SCHEDULE) THERMAL OVERLOAD, FLUSH MOUNTED, COLOR BY ARCHITECT. 2. ALL DEVICES INDICATED ON DEMOLITION PLANS ARE TO BE REMOVED <br /> CB CIRCUIT BREAKER UNLESS NOTED OTHERWISE. <br /> LINE VOLTAGE THERMOSTAT: MARKEL TW 141, SPST, COLOR BY <br /> G, GRD GROUND ARCHITECT. CONDUIT AND CONTROL WIRING BY DIVISION 16. 3, CONTRACTOR SHALL REMOVE AND PROPERLY DISPOSE OF, IN AN <br /> APPROVED MANNER, ALL EXISTING ELECTRICAL SYSTEMS NOT USED IN <br /> GFI GROUND FAULT CIRCUIT INTERRUPTER THE FINAL DESIGN. <br /> HP HORSEPOWER 4. CONTRACTOR SHALL REMOVE ALL ASSOCIATED CONDUIT, BOXES, <br /> RECEPTACLES J-BOX JUNCTION BOX CABLE, ETC. BACK TO THEIR POINT OF ORIGIN AND/OR <br /> N NEUTRAL DESTINATION. <br /> CE DUPLEX RECEPTACLE. NIC NOT IN CONTRACT <br /> DOUBLE DUPLEX RECEPTACLE. PNL PANEL <br /> ® SPECIAL PURPOSE RECEPTACLE. R RACEWAY <br /> SUBSCRIPT "R" INDICATES RANGE RO RACEWAY ONLY LECTRICAL DRAWING IN D X <br /> SUBSCRIPT "D" INDICATES DRYER. <br /> RECEPT RECEPTACLE E-0.1 ELECTRICAL SYMBOLS AND ABBREVIATIONS <br /> SPECS SPECIFICATIONS E-DX1.O UNIT "DX" ELECTRICAL SITE PLAN <br /> EQUIPMENT SW SWITCH <br /> E-DX2.1 UNIT "DX" LIGHTING PLAN <br /> SWBD SWITCHBOARD E-A3.1 TYPICAL "A" UNIT DEMOLITION, LIGHTING AND POWER PLAN <br /> V/A MAIN DISTRIBUTION PANEL TELE TELEPHONE <br /> E-133.1 TYPICAL "B" UNIT DEMOLITION, LIGHTING AND POWER PLAN <br /> iii BRANCH CIRCUIT PANEL TTB TELEPHONE TERMINAL BOARD (TTB) <br /> E-C3.1 TYPICAL "C" UNIT DEMOLITION, LIGHTING AND POWER PLAN <br /> 14) I TELEPHONE TERMINAL BOARD (TTB) TYP TYPICAL <br /> E-D3.1 TYPICAL "D" UNIT DEMOLITION, LIGHTING AND POWER PLAN <br /> 0 MOTOR CONNECTION. U.N.O. UNLESS NOTED OTHERWISE <br /> E-DX3.1 UNIT "DX" POWER PLAN <br /> UJ JUNCTION BOX. V VOLT E-E3.1 TYPICAL UNIT "E" DEMOLITION, LIGHTING AND POWER PLAN <br /> XXX VP VANDAL PROOF_ ) <br /> MECHANICAL EQUIPMENT (SEE SCHEDULE). E-F3.1 TYPICAL UNIT "F" DEMOLITION, LIGHTING AND POWER PLAN <br /> XXX W WIRE OR WATT <br /> E-FX3.1 TYPICAL UNIT "FX" DEMOLITION, LIGHTING AND POWER PLAN <br /> QI DISCONNECT SWITCH WP WEATHERPROOF <br /> E7 ME.ItR PHASE E-4.1 TYPICAL ONE-UNE DIAGRAM AND PANEL SCHEDULES <br /> (ER) EXISTING TO REMAIN E-DX4.1 UNIT "DX" ONE-LINE DIAGRAM <br /> E-4.2 LOAD CALCULATIONS <br /> ELECTRICAL RISER <br /> -'"---1-1.r FUSED SWITCH <br /> --6-1, CIRCUIT BREAKER <br /> -r\i FUSE OR CURRENT LIMITER <br /> J TRANSFORMER <br /> 1 GROUND <br /> 0, MEIER NOM <br /> anFEEDER SIZE, SEE FEEDER SCHEDULE 1. ALL WORK IS INDICATED IS TYPICAL AND TO BE COMPLETED <br /> IN ALL APARTMENT UNITS WHETHER INDICATED IN THAT <br /> SPECIFIC APARTMENT OR NOT. <br /> • - oc.D.s.� JUNE 16, 19 8 PT <br /> ,, l 9_ _ T APPLICATION <br /> Q- <br /> -. ' -.� ; ;: .! 17928 BOTHELL EVERETT HWY SE, SUITE H <br /> 0 -0 , �T51 <br /> BOTHELL, WASHINGTON 98012 <br /> '� I- ,���� ENGINEERS INC.t Ni a (425) 481-7735 FAX (425) 481-7692 <br /> `S'S/ONAL� CONTACT: CARL MAEHL <br /> EXPIRES: 6/24/98 JOB NUMBER: 7047 <br /> ® � <br /> GRAN Dv, Ew ApARTv ENTs <br /> - y <br /> v ulD - - SYMBOLS 8c ABBREVIATIONS <br /> SHEET <br /> ® GENERAL IMPROVEMENTS sTic < \ _ y v <br /> MONEY ROM DATE: JUNE 3,1998 <br /> FOR THE HOUSING AUTHORITY OF THE CITY OF EVEREI I � �"` G. <br /> F. "`� "`�"�' '"'� � DRAWN BY: MAR O . <br /> 111 NSW 4131UF, WE= SEATIl& smarm 9B104 523 -1104 CHECKED: LDB OF SHEETS <br /> - - <br />