Laserfiche WebLink
PROJECT: GRANDVIEW DEVELOPMENT RENOVATION PROJECT: GRANDVIEW DEVELOPMENT RENOVATION PROJECT: GRANDVIEW DEVELOPMENT RENOVATION PROJECT: GRANDVIEW DEVELOPMENT RENOVATION <br /> LOCATION: EVERETT LOCATION: EVERETT LOCATION: EVERETT LOCATION: EVERLII <br /> UNIT TYPE: TYPE A UNIT TYPE: TYPE B UNIT TYPE: TYPE C UNIT TYPE: TYPE D <br /> TOTAL SQUARE FT. 800 X 3 WATTS PER SQUARE FT 2400 VA TOTAL SQUARE FT. 832 X 3 WATTS PER SQUARE FT 2496 VA TOTAL SQUARE FT. 871 X 3 WATTS PER SQUARE FT 2613 VA TOTAL SQUARE FT. 925 X 3 WATTS PER SQUARE FT 2775 VA <br /> APPLIANCE CIRCUITS 2 X 1500 WA'is EACH= 3000 VA APPLIANCE CIRCUITS 2 X 1500 WATTS EACH= 3000 VA APPUANCE CIRCUITS 2 X 1500 WATTS EACH= 3000 VA APPUANCE CIRCUITS 2 X 1500 WAi IS EACH= 3000 VA <br /> LAUNDRY CIRCUITS 1 X 1500 WATTS EACH= 1500 VA LAUNDRY CIRCUITS 1 X 1500 WATTS EACH= 1500 VA LAUNDRY CIRCUITS 1 X 1500 WATTS EACH= 1500 VA LAUNDRY CIRCUITS 1 X 1500 WATTS EACH= 1500 VA <br /> GENERAL LIGHTING LOAD: 6900 VA GENERAL LIGHTING LOAD: 6996 VA GENERAL LIGHTING LOAD: 7113 VA GENERAL LIGHTING LOAD: 7275 VA <br /> DEMAND FACTOR PER N.E.C. TABLE 220-11 DEMAND FACTOR PER N.E.C. TABLE 220-11 DEMAND FACTOR PER N.E.C. TABLE 220-11 DEMAND FACTOR PER N.E.C. TABLE 220-11 <br /> FIRST 3000W OR LESS 0100% 3000 VA FIRST 3000W OR LESS 0100% 3000 VA FIRST 3000W OR LESS 0100% 3000 VA FIRST 3000W OR LESS 0100% 3000 VA <br /> FROM 3000W TO 120,000W AT 35% 1365 VA FROM 3000W TO 120,000W AT 35% 1399 VA FROM 3000W TO 120,000W AT 35% 1440 VA FROM 3000W TO 120,000W AT 35% 1496 VA <br /> REMAINDER OVER 120,000W AT 25% 0 VA REMAINDER OVER 120,000W AT 25% 0 VA REMAINDER OVER 120,000W AT 25% 0 VA REMAINDER OVER 120,000W AT 25% 0 VA <br /> LIGHTING LOAD DEMAND: 4365 VA 4365 VA LIGHTING LOAD DEMAND: 4399 VA 4399 VA LIGHTING LOAD DEMAND: 4440 VA 4440 VA LIGHTING LOAD DEMAND: 4496 VA 4496 VA <br /> COOKING APPLIANCES CALCULATIONS COOKING APPLIANCES CALCULATIONS COOKING APPLIANCES CALCULATIONS COOKING APPLIANCES CALCULATIONS <br /> PER N.E.C. TABLE 220-19, COLUMN A PER N.E.G. TABLE 220-19, COLUMN A PER N.E.C. TABLE 220-19, COLUMN A PER N.E.C. TABLE 220-19, COLUMN A <br /> NOTE 1 NOTE 1 NOTE 1 NOTE 1 <br /> 1 UNIT(S) 8 KW EA. 1 UNIT(S) 8 KW EA. 1 UNIT(S) 8 KW EA. 1 UNIT(S) 8 KW EA. <br /> N.E.C. TABLE 220-19,COLUMN A 8000 VA N.E.C. TABLE 220-19,COLUMN A 8000 VA N.E.C. TABLE 220-19,COLUMN A 8000 VA N.E.C. TABLE 220-19,COLUMN A 8000 VA <br /> 0 EXCESS KW X 0.05 5%x NUMBER OF EXCESS KW 0 EXCESS KW X 0.05 5%x NUMBER OF EXCESS KW 0 EXCESS KW X 0.05 5%x NUMBER OF EXCESS KW 0 EXCESS KW X 0.05 5%x NUMBER OF EXCESS KW <br /> 0 % ADJUSTMENT FACTOR PER NOTE 1 0 VA 0 % ADJUSTMENT FACTOR PER NOTE 1 0 VA 0 % ADJUSTMENT FACTOR PER NOTE 1 0 VA 0 % ADJUSTMENT FACTOR PER NOTE 1 0 VA <br /> COOKING APPUANCE LOAD DEMAND: 8000 VA 8000 VA COOKING APPLIANCE LOAD DEMAND: 8000 VA 8000 VA COOKING APPLIANCE LOAD DEMAND: 8000 VA 8000 VA COOKING APPLIANCE LOAD DEMAND: 8000 VA 8000 VA <br /> ELECTRIC CLOTHES DRYER(S) ELECTRIC CLOTHES DRYER(S) ELECTRIC CLOTHES DRYER(S) ELECTRIC CLOTHES DRYER(S) <br /> 1 DRYERS 5000 WATTS EACH 5000 VA 1 DRYERS 5000 WATTS EACH 5000 VA 1 DRYERS 5000 WATTS EACH 5000 VA 1 DRYERS 5000 WATTS EACH 5000 VA <br /> DEMAND® 100 % DEMAND® 100 % DEMAND@ 100 % DEMAND 100 % <br /> ELECTRIC CLOTHES DRYER DEMAND: 5000 VA 5000 VA ELECTRIC CLOTHES DRYER DEMAND: 5000 VA 5000 VA ELECTRIC CLOTHES DRYER DEMAND: 5000 VA 5000 VA ELECTRIC CLOTHES DRYER DEMAND: 5000 VA 5000 VA <br /> APPLIANCE LOAD: APPLIANCE LOAD: APPUANCE LOAD: APPUANCE LOAD: <br /> 1500 WATTS 1500 VA 1500 VA 1500 WATTS 1500 VA 1500 VA 1500 WATTS 1500 VA 1500 VA 1500 WATTS 1500 VA 1500 VA <br /> SUBTOTAL FEEDER—VOLT/AMPS: 18865 VA SUBTOTAL FEEDER—VOLT/AMPS: 18899 VA SUBTOTAL FEEDER—VOLT/AMPS: 18940 VA SUBTOTAL FEEDER—VOLT/AMPS: 18996 VA <br /> TOTAL FEEDER AMPS: TOTAL FEEDER AMPS: TOTAL FEEDER AMPS: TOTAL FEEDER AMPS: <br /> 18865 VA DIVIDED BY 240 VOLTS= 79 AMPS 18899 VA DIVIDED BY 240 VOLTS= 79 AMPS 18940 VA DIVIDED BY 240 VOLTS= 79 AMPS 18996 VA DIVIDED BY 240 VOLTS= 79 AMPS <br /> PROJECT: GRANDVIEW DEVELOPMENT RENOVATION PROJECT: GRANDVIEW DEVELOPMENT RENOVATION PROJECT: GRANDVIEW DEVELOPMENT RENOVATION <br /> LOCATION: EVERETT LOCATION: EVERETT LOCATION: EVERETT <br /> UNIT TYPE: TYPE E UNIT TYPE: TYPE F UNIT TYPE: TYPE FX <br /> TOTAL SQUARE FT. - 1034 X 3 WATTS PER SQUARE FT 3102 VA TOTAL SQUARE FT. 1248 X 3 WATTS PER SQUARE FT 3744 VA TOTAL SQUARE FT. 1488 X 3 WATTS PER SQUARE FT 4464 VA <br /> APPLIANCE CIRCUITS 2 X 1500 WATTS EACH= 3000 VA APPLIANCE CIRCUITS 2 X 1500 WATTS EACH= 3000 VA APPLIANCE CIRCUITS 2 X 1500 WATTS EACH= 3000 VA <br /> LAUNDRY CIRCUITS 1 X 1500 WATTS EACH= 1500 VA LAUNDRY CIRCUITS 1 X 1500 WATTS EACH= 1500 VA LAUNDRY CIRCUITS 1 X 1500 WATTS EACH= 1 500 VA <br /> GENERAL LIGHTING LOAD: 7602 VA GENERAL LIGHTING LOAD: 8244 VA GENERAL LIGHTING LOAD: 8964 VA <br /> DEMAND FACTOR PER N.E.C. TABLE 220-11 DEMAND FACTOR PER N.E.C. TABLE 220-11 DEMAND FACTOR PER N.E.C. TABLE 220-11 <br /> FIRST 3000W OR LESS 100% 3000 VA FIRST 3000W OR LESS 0100% 3000 VA FIRST 3000W OR LESS 0100% 3000 VA <br /> FROM 3000W TO 120,000W AT 35% 1611 VA FROM 3000W TO 120,000W AT 35% 1835 VA FROM 3000W TO 120,000W AT 35% 2087 VA <br /> REMAINDER OVER 120,000W AT 25% 0 VA REMAINDER OVER 120,000W AT 25% 0 VA REMAINDER OVER 120,000W AT 25% 0 VA <br /> LIGHTING LOAD DEMAND: 4611 VA 4611 VA LIGHTING LOAD DEMAND: 4835 VA 4835 VA LIGHTING LOAD DEMAND: 5087 VA 5087 VA <br /> COOKING APPLIANCES CALCULATIONS COOKING APPLIANCES CALCULATIONS COOKING APPLIANCES CALCULATIONS <br /> PER N.E.C. TABLE 220-19, COLUMN A PER N.E.C. TABLE 220-19, COLUMN A PER N.E.C. TABLE 220-19, COLUMN A <br /> NOTE 1 NOTE 1 NOTE 1 <br /> 1 UNIT(S) 8 KW EA. 1 UNIT(S) 8 KW EA. 1 UNIT(S) 8 KW EA. <br /> N.E.C. TABLE 220-19,COLUMN A 8000 VA N.E.C. TABLE 220-19,COLUMN A 8000 VA N.E.C. TABLE 220-19,COLUMN A 8000 VA <br /> 0 EXCESS KW X 0.05 5%x NUMBER OF EXCESS KW 0 EXCESS KW X 0.05 5%x NUMBER OF EXCESS KW 0 EXCESS KW X 0.05 5%x NUMBER OF EXCESS KW <br /> 0 % ADJUSTMENT FACTOR PER NOTE 1 0 VA 0 % ADJUSTMENT FACTOR PER NOTE 1 0 VA 0 % ADJUSTMENT FACTOR PER NOTE 1 0 VA <br /> COOKING APPLIANCE LOAD DEMAND: 8000 VA 8000 VA COOKING APPLIANCE LOAD DEMAND: 8000 VA 8000 VA COOKING APPLIANCE LOAD DEMAND: 8000 VA 8000 VA <br /> ELECTRIC CLOTHES DRYER(S) ELECTRIC CLOTHES DRYER(S) ELECTRIC CLOTHES DRYER(S) <br /> 1 DRYERS 5000 WATTS EACH 5000 VA 1 DRYERS 5000 WATTS EACH 5000 VA 1 DRYERS 5000 WATTS EACH 5000 VA <br /> DEMANDI. 100 % DEMANDS' 100 <br /> DEMANDS 100 % <br /> ELECTRIC CLOTHES DRYER DEMAND: 5000 VA 5000 VA ELECTRIC CLOTHES DRYER DEMAND: 5000 VA 5000 VA ELECTRIC CLOTHES DRYER DEMAND: 5000 VA 5000 VA <br /> APPLIANCE LOAD: APPLIANCE LOAD: APPLIANCE LOAD: <br /> 1500 WATTS 1500 VA 1500 VA 1500 WATTS 1500 VA 1500 VA 1500 WATTS 1500 VA 1500 VA <br /> SUBTOTAL FEEDER—VOLT/AMPS: 19111 VA SUBTOTAL FEEDER—VOLT/AMPS: 19335 VA SUBTOTAL FEEDER—VOLT/AMPS: 19587 VA <br /> TOTAL FEEDER AMPS: TOTAL FEEDER AMPS: TOTAL FEEDER AMPS: <br /> 19111 VA DIVIDED BY 240 VOLTS= 80 AMPS 19335 VA DIVIDED BY 240 VOLTS= 81 AMPS • 19587 VA DIVIDED BY 240 VOLTS= 82 AMPS <br /> v-Qv WAS. JUNE 16, 1998 PERMIT APPLICATION <br /> E , /Y <br /> 17928 BOTHELL EVERETT HWY SE, SUITE H <br /> d,) BOTHELL, WASHINGTON 98012 <br /> 'A ��- wa ', � ���� ENGINEERS INC. (425) 481-7735 FAX (425) 481-7692 <br /> 'r CONTACT: CARL MAEHL <br /> S�it�vAL.�-�'�'��. <br /> EXPIRES: 6/24/98GRANDVIEW APARTMENTS 411B01■6110 GENERAL IMPROVEMENTS sT c < \ .... y <br /> M <br /> JOB NUMBER: 7047 <br /> SHEET <br /> ,�, LOAD CALCULATIONS <br /> FOR THE HOUSING AUTHORITY OF THE CITY OF EVERETT • �WM G. MCC POW„ F '°' it `� DATE: BY: MAR 3,,998 4. 2 <br /> SAFE VA en Wen= 96104 t614 623-1104 CHECKED: LOB OF SHEETS <br />