Laserfiche WebLink
l <br /> ® — rrr®1 .loss■ — mama s.s® alma= _m rrltru II <br /> itv 1 _ LINTY�E0eII <br /> O I a s PLAN N <br /> 1 rSa _a u f r�- <br /> s , --1 <br /> • I <br /> � CLEM CLEA3 CLEAR CLEMEXISTING WALL <br /> l - _ - - ,4 ® REMOVE GWB ENTIRELY FIZOM ALL EXTERIOR <br /> „' - WALLS AND WOOD SIDING FROM UTILITY ROOM <br /> ig G a o - N.•r <br /> �� J _ il e ` _e 1�_ I • I : • p I I4 WALLS. REMOVE TI�M FROM AROUND WINDOW <br /> .-. I I ,9 •-�' 1 , ( •n- :IN& �C I I : I PROTECT SILL,JAMBAND HEAD DURING GWB REMOVAL <br /> , ( ,�. ..-_emu ,, <br /> P 1 n 23L 2 L MC ; 23 h 2 C REMOVE GWB ENTIRELY FROM ONE <br /> c J..••i <br /> SIDE OF DEMISING WALL <br /> ..4 1 J. N rr.. c <br /> ❑❑ • 1 I 00�, 4 -fp i 18 _ 18 <br /> , - \ ai 1 ( 3LM> r g 23LMC (-231ZMG7 <br /> (23RC <br /> 1 9 �' 2 M REMOVE PORTION OF CEILING ABOVE r..:•::•:•.:.::•:•:•::•:•::•:•1 <br /> rf;) 2 L ` 2 LM 23g MAX ARM 24"X 24"COORDINATE WITH <br /> 4. 0, 49 _ ,� = -_ - 6 : MECWELEG DRAWINGS/SPECIFICATIONS <br /> _!, ' _1 I I ' ' 11 A 1 . ,°`. e i i I JJ • A7.1 4 DEMO ALL INTERIOR DOORS AND FRAMES, <br /> a_p 1 1I _r .. <br /> ,Amilia <br /> orsi sears <br /> raoti rrirra ee®_ �1 rr�em _:„ :. raierar prow,, _® rams <br /> ¢ �� TYF ��_m •f ALL CABINETRY,ALL PLYWOOD WALLS <br /> "-ONO 18 23L > � / �L'M 18 4) - 18 1 2 RM �r 18 ANDALL PLUMBING(EXCEPT TUBS) <br /> 0 ., .//// //�// 1. f/r' /1'/ / //`//.1 i / / /),23K <br /> -''` /7/ ///�•'�,.//77/C • REMOVE GWB FROM FLOOR TO MAX 50 AFF <br /> �' I r` _ I -� ---- {@�SIM REMOVE GWB COMPLETELY FROM <br /> ,, 20L ILh 422L4 22fi�P�1C�o d- 2C�I�I I ORC ——-_, CEILING)FLOOR TO <br /> COORDINATE WM-I NEW <br /> 1 �ii...,..,.,.: 1 I t""—,�1..." .I...+++w�e�iM 1 1 1 _.. <br /> �4 •"� p INSTALLATIONS PER ELECTRICAL AN M <br /> \ r ( OI � ' �2C ) MECHANICAL <br /> .F:71 .. 'r , 20 .) 2 MC ,,, . _m "__ �',-, ,, • 1 20,R6 N V D NICAL <br /> , ...._ �/ I:.... I © ?�LG a o (22LM1C 2--RPr1G N i 4 <br /> '� © •�` � // � � 2,-© �22RC) � DRAWINGS FOR LOCATION AND EXTENT OF DEMO <br /> ! M� I l\ > DNS DN _ '-O �. PH f /CL p ,�: -�:� \CLE �-9a ® RELOCATE VENT IN NEW WALL <br /> ' ■� 111 Iill <br /> 20L 14 2DLM r 7 a 9" 20I M 1�e: 0RVIFY 'gI VERIFY WITH ARCHITECT AND MECH DWGS <br /> ( Q f I FY 4 �J1 1 � � IN, - - �' `� REMOVE EXISTING VENT AND CONNECTING DUCT. <br /> o7ti, v 22LM (22R) .r <br /> a I *Div � �22L 22LM) �� lirETE1) PLUG WITH INSULATION AND COVER WITH <br /> 51 �`� J 1.© ,;>, I. 1M .Oa 3'_6" IM 21L, w �..... �.! �ry o-:\M. C L�. C1RM} ;r,� • ` o _\_i 1 'IR� VINYL SIDING(OFGI)TO MATCH EXISTING <br /> ' I REMOVE CARPET AND CARPET PAD FROM ALL ROOMS <br /> t <br /> • <br /> � a w .a.a� ® � rrs,� 'a.��.�•::.•.�"'�''.ta.+a e., d.'n: •. • B. •. his, _ .. -valor ..�o. �. � :. 0 � �a 4 , <br /> INH; MPH; 1 "NH; ;WH 4 • J <br /> i''► h :►� k • G• REMOVE BATHTUB SURROUND AND GWB BACKING <br /> 177 i ; 1! x REMOVE GLASS AND SLIDING DOOR SHOWER <br /> 1 ! v n ' ' IIII 22L 21L `, ; \ �J 21LM 22LM A 221;:M 21i M ` i . _\ ) 21 22I A55EMBLYPROTECTANDREINSTALL <br /> — `—— I �TYP <br /> 1 --. I' <br /> * 1 1 4 T P N � � pc___,I, 0 I • `� REMOVE EXISTING TILE FLOORING FROM BA?HAND <br /> L _, I J „. IIli o AND WHERE REMAINING IN OTHER ROOMS. <br /> ' l'�I'=i i u , l■I 1. r I- 1111-'3. 40 o KITCHEN <br /> VERIFY ASBESTOS TILE LOCATIONS PRIOR TO BED <br /> -.e �L'+**%PJi1 1 Ir+'� � it�411,.��"� �..1 1I&!1 I '- 4 i ��'i'ili.19- �� ...w�l.l_� <br /> 'N.���i�i1�.1�«, di1�i�+.�' - -- - -- - - -- 1 - � ��--= SUBMtT1'AL. IF 9 x 9 Oi212 x 12 ASBESTOS TILE 15 <br /> ' _�/ ENCOUNTERED, CONTRACTOR SHALL FOLLOW PASAPCA <br /> � — : II I �� III <br /> Q l - , o REQUIREMENTS FOR REMOVALAND DISPOSAL. <br /> FIU1-ELOOI~ NEW 2 x 4 WOOD STUD CdNSTRUG110N4 <br /> ® NEW 1/2"GWB OVER R-11(R 19 if 2x6 CONSTRUCTION)9=Z65525825992 <br /> DEMOLITION L BATTINSULATION @ALL EXTERIOR WALLS, INCLUDING <br /> �' NEW TRIM TO MATCH @ EXTERIOR WINDOWS, PROVIDE <br /> SCALE: 1/8"= 1'-a' SCALE: 1/4" =1'-a' , ' 6 MIL VAPOR BARRIER BETWEEN NEW GWB AND INSULATION. <br /> c` X <br /> 5 L; 4 NEW 5/8'TYPE"X'GWB OVER NEW RESILIENT r--�'---' -' . <br /> /) CHANNEL W/NEW SOUND BATT @ DEMISING WALL <br /> ❑ ❑ ❑ p `l ' NEW 5/81 TYPE'X'GWB OVER NEW SCUJND 4`. .•°•-.--- <br /> BATT INSULATION @ DEMISING WALL <br /> NEW PLAM TUB SURROUND OVER 1/2"MARINE ivieMsrawR. <br /> ----- - - - - ��,� �...� �...�. r� r�r..� r . TUB DEMISING <br /> i 1 rl Il""�' ...I�. If 1'll'�' . 1 -1 11 siaini p ,- : i I Iga YWD W/NEW 'ABOVE OP OF M <br /> ' ii . <br /> GRAD PLYWOODSOUND BATT IN <br /> ' I I WALL EXPEND PL <br /> I I I ,� +4 1 •TYF 22 <br /> 0 .I AND 1 INCH MIN TO EACH SIDE•SEE 5/A7.1 <br /> / y I (• 4, a NEW.0. WOOD HANDRAIL. RETURN ENDS TO WALL AS <br /> • `�'II i Up *1. 1 - U0' �-. <br /> UP U, INDICATED. LOCATE EXISTING STUDS FOR MOUNTING BRACKETS. <br /> INN <br /> ATTIC TTIC ATTIC •TTIC -1 I I. NNE I SEE FINISH NOTES. <br /> ACCESS_. -- I .......&ESS E55 I Ar-.,CESS I ACCESS �III' PROVIDE ONE CLOTHES ROD @60"AFF AND <br /> _ '""�`'� '� ---: '"`..'..,�""`--.�_:_ . �' { . TWO 14"DEEP MELAMINE SHELVES, TYPICAL <br /> ---�------- '_-. _,ILL <br /> { I I ��� I Ii[�� Ty <br /> �" �I 1 ,/ <br /> '- " - '-' ` ' - " ' ' 1I ICI =Am I 1�� NEW OPEN SHELVING IN UTILITY ROOM USE 1°MDF(PAINTED) <br /> �i11�I I I�/ 1 LM • <br /> I I I 1 L ��I ( Mil 1 cow x 12"D x 48"TALL @ 36"A.F.F.PROVIDE TWO INTERIOR <br /> III SHELVES EQUALLY SPACED LOCATION TO BE DETERMINED. <br /> 1_ II — <br /> ' �' ' MI <br /> J I► LOCATE AND MOUNT ON EXISTING STUDS. VERIFY SIZE <br /> + I 4„„. ! o AND LOCATION WITH OWNER. <br /> .t1' 0 ... <br /> I I +► I • NEW 1/2"GWB ON ALL WALLS IN UTILITY ROOM <br /> 1 --) <br /> I I - i EXCEPT 5/8"TYPE'X°@DEMISING WALL <br /> - ° '-�a 1L 1 MC -6r '-�° 21-6,u x,.e11 _ 1�:M i 1�IC '-�� 2'- <br /> ./ <br /> �� • NEW WALL CABINET-PROVIDE SOLID BACKING <br /> ✓ 1L I I /6-1-3,./c) I t t T � MG� I 1Re� 1►- CENTER ABOVE TOILET <br /> SECOND FLOOR Pie <br /> ❑ , . A A I 1 , - p . MODIFY EXISTING ROOF SHEATHING AND MEMBRANE <br /> KITCHEN I 0.1'.C.I, O F}C•I• I O.FI.C.I. •F •I" I KITCHEN TO ACCOMODATE NEW DUCTS PENETRATING ROOF-SEE MECH <br /> EXHAUST 0 Q RE ►4 1 EF 00 40 1� F .� RAF 0 0 EXHAUST PROVIDE TWO NEW LOCKS PER SPECIFICATIONS <br /> _ O.F.C.I. I 0.F.C.I. I I 1 0.F.C.I. _ <br /> TO SECURE ATTIC ACCESS DOOR <br /> 0 NEW FINISHED F ®1411,-- F NEW FINISHED - I - NEW FINISHED F El El <br /> ® � F NEW FINISHED • PATCH ALL DAMAGED AREAS RESULTING FROM <br /> Ocs) <br /> OPENING-SEE a OPENING-SEE I I OPENING-SEE OPENING-SEE I DEMOLITION. REFER TO DEMOLITION PLANS FOR ALL AREAS. <br /> �� INTERIOR ELEV WH INTERIOR ELEV �► I I ,� INTERIOR ELEV CD VdH INTERIOR ELEV ,,n� L �� FIELD VERIFYAND COORDINATE WITH ELECI121CAL <br /> id-- ` ' AND MECHANICAL SUB-CONTRACTORS FOR <br /> O I i `�i4� -- ___ `��� ri <br /> ADDITIONAL REPAIR WORK DUE TO NEW INSTALLATIONS. <br /> 4t. CD 40 <br /> 44 h. 2L► j) I ,'r! A A-.1 ) �am Ill PROVIDE SOLID BACKING ALONG ALL EDGES. <br /> © II2L AIM �1 C2R� _ <br /> TYP <br /> p____, <br /> T ►`�' •Ac4.1 i00s� ,,, REPAIR AND REINSTALL AS REQUIRED,ALL <br /> I 2L '1 i I-10.>✓.C.i. I EXISTING ACCESS DOORS AT BATHTUBS,TYP. <br /> ®� ,-�o j L ELM 2LM I Q 2 M CONSTRUCT NEW DRAFTSTOPAS REQUIRED BY UBC 108. <br /> • <br /> C `icy I I IN ATTIC-IN LINE WITH UNIT DEMISING WALLS. <br /> �>1t��il1�1�IG�di- 1 1 Ir��d��+�*'i1�'Ai?1 1��.1�� �,��a1 1 i�itr,��t►s. <br /> it> -- ----1( INSTALL P.T.WOOD BLOCKING @ 4'-0"O.C.TO SUPPORT GAS <br /> E 2 <br /> ., PIPING. FASTEN BLOCKING TO WALL. <br /> ��� 41C 2 . • REPLACE DAMAGED GWB WITH NEW TYPE"X'GWB TO MATCH. <br /> MIDDLE UNIT <br /> ' is GENERAL (COTES: <br /> II <br /> II 1. SEE SITE PLAN FOR BUILDING ORIENTATION <br /> � � '� • ,� 2. INSTALL ARE BLOCKING BETWEEN STUDS @4>3 AFF <br /> 0 ,� •��� - , , J to.. ,,. ❑ IN ALL NEW WALLS AND EXISTING WALLS WHERE <br /> FLOORFIRST PATCH ALL DAMAGED AREAS RESULTING FROM FRAMING HAS BEEN EXPOSED <br /> • DEMOLITION. REFER TO DEMOLITION PLANS FOR ALL AREAS. NOTE: ALL WORK I N DDICATEID IS TYPICAL <br /> EFLECTE.PCEILING PLANS FIRST- FLOOR <br /> FLAN FIELD VERIFY AND COORDINATE WITH ELECTRICAL AND IS TO t3E COMPLECOMPLETEDI N ALL <br /> SCALE: 1/8"= 1'-0" l� SALE: 1/4" =1'-a' AND MECHANICAL SUB-CONTRACTORS FOR NOTE: SEEI TE � � APARTMENT UNITS WHETHER INDICATED <br /> ADDITIONAL REPAIR WORK DUE TO NEW INSTALLATIONS. IN THAT SPECIFIC Af ARTMENT• OR NOT <br /> PROVIDE SOLID BACKING ALONG ALL EDGES. FOR DUI L DING Ot.I EN AT1 ON <br /> GRANDviEw ApARTmENTs <br /> STICKN[._; 494tREGiGTEREDSHEET 4 <br /> �. GENERAL impRo vEmENTs TYPE C <br /> AR CT <br /> RTT FRANK G. STICKNEY o RONALD F. MURPHY o MICHAEL W.ROMINE, ARCHITECTS PLLC MICHAEL . R(�MINE DATE: June 16,1998 <br /> FOR THE HOUSING AUTHORITY OF THE CITY OF EVEE <br /> 'h° 911 WESTERN AVENUE, SUITE 200, SEATTLE, WASHINGTDN 98104 0 (206)623 t 104 STATE OF WASHINGTON DRAWN 8Y: YMA PERMIT APPLICATION <br /> C,3,1 <br /> CHECKED: OF 12 SHEETS <br />