WALL TYPE COPYRIGHT NOTICE
<br /> THIS DOCUMENT AND THE INFORMATION
<br /> GENERAL NOTES AN HEREIN
<br /> NSTRUMENTOFOSERVICE AND PROJECT THE ARE
<br /> COPYRIGHTED PROPERTY OF BOTESCH,
<br /> NASH AND HALL ARCHITECTS, P.S. NO
<br /> PART HEREOF SHALL BE COPIED,
<br /> DUPLICATED, DISTRIBUTED, DISCLOSED OR
<br /> MADE AVAILABLE TO OTHERS OR USED TO
<br /> ANY EXTENT WHATSOEVER, EXCEPT AS
<br /> I. WALL TYPES DO NOT INCLUDE WALL EXPRESSLY AUTHORIZED IN WRITING BY
<br /> FINISHES. SEE FINISH SCHEDULE FOR BOTESCH, NASH AND HALL ARCHITECTS,
<br /> P.S.
<br /> WALL FINISH INFORMATION.
<br /> co
<br /> 2. ALL RATED WALLS SHALL EXTEND FROM u i
<br /> Q
<br /> FLOOR TO UNDERSIDE OF ROOF OR °O
<br /> � CV FLOOR ABOVE. I
<br /> I
<br /> 3. ALL AIR INFILTRATION BARRIERS, VAPOR
<br /> BARRIERS AND INSULATION ARE TO
<br /> EXTEND TO THE UNDERSIDE OF ROOF N Q
<br /> DECK. Z o
<br /> p m
<br /> 4. PROVIDE SEALANT BELOW ALL EXTERIOR N a- N
<br /> •io'se sw ,, ..a ..� ..� ,,...... � WALL BOTTOM SILLS. w
<br /> cc
<br /> ..rNat f w �-
<br /> (2) LAYERS 5/8" TYPE \ 5. ALL INTERIOR WALL PARTITIONS (STUDS, W
<br /> I 'X' GWB SHEATHING, AND SOUND BATTS) TO
<br /> a
<br /> 5-1/2" WOOD STUDS AT 16"
<br /> ,:'Op
<br /> EXTEND 8" ABOVE SUSPENDED CEILINGS.
<br /> r O.C. - SPECIES PER FINISHES (CERAMIC TILE, PAINT, ETC.)
<br /> STRUCTURAL ENGINEER TO EXTEND TO CEILINGS ONLY.t r iI:1R-2I INSULATION BATTS6. REFERENCE FLOOR PLANS FOR
<br /> • SHEATHING PER LOCATIONS AND TYPES OF ALL RATED
<br /> %�` STRUCTURAL WALLS.
<br /> •
<br /> � A WATERPROOFING MEMBRANE
<br /> 7. STAGGER ALL GYP. BOARD JOINTS WERE CO
<br /> : %'� �� (2) LAYERS 5/8" TYPE
<br /> :: ,_� MULTIPLE LAYERS ARE PRESENT, = o M,
<br /> ;:; ;_sue 'X' GYP. SHEATHINGN�,
<br /> —i:i��� _�,�I 3/4" MASONRY MAT �
<br /> , B. ATTACH MULTIPLE LAYERS OF GYP,
<br /> Q
<br /> �//,�€II�I����I� BRICK VENEER BOARD WITH SCREWS; DO NOT USE
<br /> \ ADHESIVE. (I)
<br /> NOTE: 2HR FIRE RESISTANCE I
<br /> q, NO BACK TO BACK OUTLETS AND Z >
<br /> RATING PER GA FILE NO. 8410. MINIMUM 24" APART. CAULK ALL - `-`' X
<br /> D6 2HR BRICK VENEER OPENINGS IN ELECTRICAL BOXES. FIRE V U •
<br /> r ■ 1'-O' ,..° STOP AROUND OUTLETS AND OPENINGS N
<br /> �\ LARGER THAN 16" SQUARE. o
<br /> �
<br /> 10. WHERE A DOUBLE ROW OF STUDS IS ,
<br /> USED MAKE NO CONNECTIONS BETWEEN m < cn in
<br /> (2) LAYERS 5/8" TYPE ROWS U.N.O. �`'
<br /> 'X' GWB, STAGGER >, )
<br /> ` 4Q (-NI JOINTS. 11. WHERE A SOUND RETARDANT PARTITION ol
<br /> IIIIII, I ABUTS PERPENDICULARLY TO A
<br /> 5-1/2" WOOD STUDS AT 16" o
<br /> CO
<br /> A O.C. - SPECIES PER CONTINUOUS GYP. BOARD PARTITION, o
<br /> INTERRUPT THE GYP. BOARD AT THE N a
<br /> STRUCTURAL ENGINEER
<br /> POINT OF INTERSECTION AND CAULK N
<br /> R-21 INSULATION BATTS THE JOINT LIBERALLY. DO NOT
<br /> ���1 SHEATHING PER ICNTERSECTING ERSECT NG STUD.
<br /> NTINUE THE GYP. BOARD BEHIND THE
<br /> Ell STRUCTURAL
<br /> 110
<br /> WATERPROOFING MEMBRANE 12. ALL OPENINGS AROUND PIPE
<br /> �"! PENETRATIONS SHALL BE SEALED WITH
<br /> N� FIBER CEMENTITIOUS SIDING A NON-HARDENING SILICONE MASTIC PER
<br /> UBC REQUIREMENTS.
<br /> GA FILE NO: 4135 13, PROVIDE SOLID 2x WOOD BACKING
<br /> D5 5-1/2" WOOD STUDS (2HR) (DF#2) AT ALL WALL ELEMENTS
<br /> (CASEWORK, TOILET ROOM ACCESSORIES,
<br /> 1. - -0 WHITE BOARDS, HANDRAILS, DOOR
<br /> STOPS, ETC.).
<br /> 14. ALL EXTERIOR METAL STUDS, INTERIOR CO
<br /> CC
<br /> 5/8 TYPE X GWB METAL STUDS AT DOOR AND WINDOW
<br /> OPENINGS TO BE 18 GA. U.N.O.
<br /> IBA 5-1/2" WOOD STUDS AT 16"
<br /> O.C. - SPECIES PER 15. ALL INTERIOR METAL STUDS TO BE, 20 Q-
<br /> STRUCTURAL ENGINEER
<br /> =- GA. U.N.O. Z
<br /> %�� RN21 INSULATION BATTS 16 HEIGHTS ABUTRE DIFFERENT CEILING (�
<br /> S EATHING PERPARTITIONTHE
<br /> �'�i STRUCTURAL PARTITION SHOULD EXTEND 8" ABOVE J CO
<br /> At W N
<br /> ��� WATERPROOFING MEMBRANE THE HIGHEST CEILING,
<br /> �,��� FIBER CEMENTITIOUS SIDING 17. PROVIDE HORIZONTAL STUD BRACING a ...,,,
<br /> ►_—� BETWEEN TOP OF PARTITION AND
<br /> '� EXCEEDSRE-WHEN THIS DISTANCE
<br /> 3 0 . 2
<br /> 18. PROVIDE WATER RESISTANT GYPSUM >mP.
<br /> BOARD (GREEN BOARD) AT ALL WATER CC = F—
<br /> D4 5-1/2" WOOD STUDS PRONE AREAS. (I.E. RESTROOMS, SINKS, < F— W 1 1 0
<br /> •
<br /> AND DRINKING FOUNTAINS.) No-
<br /> N.
<br /> CC
<br /> F.:2.
<br /> 5/8" TYPE 'X' GWB CD CO W
<br /> A
<br /> 5-V2" WOOD STUDS AT I6" �►� 5/8" TYPE 'X' GYP, BOARD
<br /> Wei O.C. - SPECIES PER ...mg SIDE
<br /> r " STRUCTURAL ENGINEER
<br /> %� 4 �� 7—SOUND ATENUATION 3776
<br /> R-21 INSULATION BATTS BATTS TO FILL WALL REGISTERED
<br /> A ; s SHEATHING PER �� CAVITY ARCHITECT
<br /> // %��� STRUCTURAL =� /-3-1/2" WOOD STUDS AT 16"
<br /> ` s-� WATERPROOFING MEMBRANE �� O.C. - SPECIES PER
<br /> .., ,_— -- ANDREW M
<br /> / , ; STRUCTURAL ENGINEER III
<br /> STATE OF WASHINGTON
<br /> ...i,,1�,1 3/4 MASONRY MAT
<br /> MI, i;iii0��I BRICK VENEER
<br /> g 1w USE WATER RESISTANT
<br /> A=:��'M! GYP. BD. IN MOISTURE
<br /> JOB NUMBER
<br /> PRONE AREAS 14-1o56A
<br /> DATE
<br /> O*5-1/2" WOOD STUDS 3-1/2" WOOD STUDS 5,20/gaito
<br /> 1• • 1'-0• .r a 1'-Q. DRAWN BY
<br /> ( y\ CHECKED BY
<br /> 5-1/2 WOOD STUDS AT 16
<br /> H
<br /> 4 ! 1
<br /> ��� �%� O.C. - SPECIES PER '� � �_�y �, K�� �'���-`'
<br /> � m�'s STRUCTURAL ENGINEER 1 �4 1►� 5/6" TYPE 'X' GYP. BOARD y `�"� `"'
<br /> . 5/8 TYPE 'X' GYP, BOARD SHEET TITLE
<br /> '° ���1��� TYP. EACH SIDE
<br /> o R-21 INSULATION BATTS '
<br /> TYP. EACH SIDE ►A
<br /> �►� \ —� MAY 2 9 2019
<br /> F �► WOOD SHEATHING PER ? ' . �3
<br /> ��� �`', STRUCTURAL �� SOUND ATENUATION �� SOUND ATENUATION
<br /> MSV-ONE
<br /> BATTS TO FILL WALL � BATTS TO FILL WALL CH `r OF EVERETT WALL
<br /> 5/8" TYPE 'X' GYP. BOARD CAVITYPermit ervices T'11'`PES
<br /> SIDE 5-1/2" WOOD STUDS AT 16" W4 3-1/2" WOOD STUDS AT 16"
<br /> .ln� A O.C. - SPECIES PER ► • O.G. - SPECIES PER
<br /> c
<br /> � ������, EXISTING 8x4x16 STRUCTURAL � STRUCTURAL ENGINEER �� STRUCTURAL ENGINEER
<br /> �NIF••-�`�0 BRICK, FIRESTOP ALL ) __/r
<br /> 4 PENETRATIONS, �g1 •• USE WATER RESISTANT
<br /> iii
<br /> e.
<br /> '� 1A USE WATER RESISTANT SHEET NUMBER
<br /> �� GYP. BD. IN MOISTURE W .
<br /> k PRONE AREAS GYP. BD. IN MOISTURE
<br /> NOTE: 4HR FIRE RESISTANCE ��°�\
<br /> W
<br /> PRONE AREAS
<br /> RATING PER IBC TABLE 721.1
<br /> A (E) 8" MASONRY WALL 5-1/2" WOOD STUDS 3-1/2" WOOD STUDS A8 • O '_
<br /> ®T , 1.-0• I D1 r ■ 1'-o• (Dr ■ 1 -0die
<br /> v\, " iil
<br />
|