Laserfiche WebLink
WALL TYPE COPYRIGHT NOTICE <br /> THIS DOCUMENT AND THE INFORMATION <br /> GENERAL NOTES AN HEREIN <br /> NSTRUMENTOFOSERVICE AND PROJECT THE ARE <br /> COPYRIGHTED PROPERTY OF BOTESCH, <br /> NASH AND HALL ARCHITECTS, P.S. NO <br /> PART HEREOF SHALL BE COPIED, <br /> DUPLICATED, DISTRIBUTED, DISCLOSED OR <br /> MADE AVAILABLE TO OTHERS OR USED TO <br /> ANY EXTENT WHATSOEVER, EXCEPT AS <br /> I. WALL TYPES DO NOT INCLUDE WALL EXPRESSLY AUTHORIZED IN WRITING BY <br /> FINISHES. SEE FINISH SCHEDULE FOR BOTESCH, NASH AND HALL ARCHITECTS, <br /> P.S. <br /> WALL FINISH INFORMATION. <br /> co <br /> 2. ALL RATED WALLS SHALL EXTEND FROM u i <br /> Q <br /> FLOOR TO UNDERSIDE OF ROOF OR °O <br /> � CV FLOOR ABOVE. I <br /> I <br /> 3. ALL AIR INFILTRATION BARRIERS, VAPOR <br /> BARRIERS AND INSULATION ARE TO <br /> EXTEND TO THE UNDERSIDE OF ROOF N Q <br /> DECK. Z o <br /> p m <br /> 4. PROVIDE SEALANT BELOW ALL EXTERIOR N a- N <br /> •io'se sw ,, ..a ..� ..� ,,...... � WALL BOTTOM SILLS. w <br /> cc <br /> ..rNat f w �- <br /> (2) LAYERS 5/8" TYPE \ 5. ALL INTERIOR WALL PARTITIONS (STUDS, W <br /> I 'X' GWB SHEATHING, AND SOUND BATTS) TO <br /> a <br /> 5-1/2" WOOD STUDS AT 16" <br /> ,:'Op <br /> EXTEND 8" ABOVE SUSPENDED CEILINGS. <br /> r O.C. - SPECIES PER FINISHES (CERAMIC TILE, PAINT, ETC.) <br /> STRUCTURAL ENGINEER TO EXTEND TO CEILINGS ONLY.t r iI:1R-2I INSULATION BATTS6. REFERENCE FLOOR PLANS FOR <br /> • SHEATHING PER LOCATIONS AND TYPES OF ALL RATED <br /> %�` STRUCTURAL WALLS. <br /> • <br /> � A WATERPROOFING MEMBRANE <br /> 7. STAGGER ALL GYP. BOARD JOINTS WERE CO <br /> : %'� �� (2) LAYERS 5/8" TYPE <br /> :: ,_� MULTIPLE LAYERS ARE PRESENT, = o M, <br /> ;:; ;_sue 'X' GYP. SHEATHINGN�, <br /> —i:i��� _�,�I 3/4" MASONRY MAT � <br /> , B. ATTACH MULTIPLE LAYERS OF GYP, <br /> Q <br /> �//,�€II�I����I� BRICK VENEER BOARD WITH SCREWS; DO NOT USE <br /> \ ADHESIVE. (I) <br /> NOTE: 2HR FIRE RESISTANCE I <br /> q, NO BACK TO BACK OUTLETS AND Z > <br /> RATING PER GA FILE NO. 8410. MINIMUM 24" APART. CAULK ALL - `-`' X <br /> D6 2HR BRICK VENEER OPENINGS IN ELECTRICAL BOXES. FIRE V U • <br /> r ■ 1'-O' ,..° STOP AROUND OUTLETS AND OPENINGS N <br /> �\ LARGER THAN 16" SQUARE. o <br /> � <br /> 10. WHERE A DOUBLE ROW OF STUDS IS , <br /> USED MAKE NO CONNECTIONS BETWEEN m < cn in <br /> (2) LAYERS 5/8" TYPE ROWS U.N.O. �`' <br /> 'X' GWB, STAGGER >, ) <br /> ` 4Q (-NI JOINTS. 11. WHERE A SOUND RETARDANT PARTITION ol <br /> IIIIII, I ABUTS PERPENDICULARLY TO A <br /> 5-1/2" WOOD STUDS AT 16" o <br /> CO <br /> A O.C. - SPECIES PER CONTINUOUS GYP. BOARD PARTITION, o <br /> INTERRUPT THE GYP. BOARD AT THE N a <br /> STRUCTURAL ENGINEER <br /> POINT OF INTERSECTION AND CAULK N <br /> R-21 INSULATION BATTS THE JOINT LIBERALLY. DO NOT <br /> ���1 SHEATHING PER ICNTERSECTING ERSECT NG STUD. <br /> NTINUE THE GYP. BOARD BEHIND THE <br /> Ell STRUCTURAL <br /> 110 <br /> WATERPROOFING MEMBRANE 12. ALL OPENINGS AROUND PIPE <br /> �"! PENETRATIONS SHALL BE SEALED WITH <br /> N� FIBER CEMENTITIOUS SIDING A NON-HARDENING SILICONE MASTIC PER <br /> UBC REQUIREMENTS. <br /> GA FILE NO: 4135 13, PROVIDE SOLID 2x WOOD BACKING <br /> D5 5-1/2" WOOD STUDS (2HR) (DF#2) AT ALL WALL ELEMENTS <br /> (CASEWORK, TOILET ROOM ACCESSORIES, <br /> 1. - -0 WHITE BOARDS, HANDRAILS, DOOR <br /> STOPS, ETC.). <br /> 14. ALL EXTERIOR METAL STUDS, INTERIOR CO <br /> CC <br /> 5/8 TYPE X GWB METAL STUDS AT DOOR AND WINDOW <br /> OPENINGS TO BE 18 GA. U.N.O. <br /> IBA 5-1/2" WOOD STUDS AT 16" <br /> O.C. - SPECIES PER 15. ALL INTERIOR METAL STUDS TO BE, 20 Q- <br /> STRUCTURAL ENGINEER <br /> =- GA. U.N.O. Z <br /> %�� RN21 INSULATION BATTS 16 HEIGHTS ABUTRE DIFFERENT CEILING (� <br /> S EATHING PERPARTITIONTHE <br /> �'�i STRUCTURAL PARTITION SHOULD EXTEND 8" ABOVE J CO <br /> At W N <br /> ��� WATERPROOFING MEMBRANE THE HIGHEST CEILING, <br /> �,��� FIBER CEMENTITIOUS SIDING 17. PROVIDE HORIZONTAL STUD BRACING a ...,,, <br /> ►_—� BETWEEN TOP OF PARTITION AND <br /> '� EXCEEDSRE-WHEN THIS DISTANCE <br /> 3 0 . 2 <br /> 18. PROVIDE WATER RESISTANT GYPSUM >mP. <br /> BOARD (GREEN BOARD) AT ALL WATER CC = F— <br /> D4 5-1/2" WOOD STUDS PRONE AREAS. (I.E. RESTROOMS, SINKS, < F— W 1 1 0 <br /> • <br /> AND DRINKING FOUNTAINS.) No- <br /> N. <br /> CC <br /> F.:2. <br /> 5/8" TYPE 'X' GWB CD CO W <br /> A <br /> 5-V2" WOOD STUDS AT I6" �►� 5/8" TYPE 'X' GYP, BOARD <br /> Wei O.C. - SPECIES PER ...mg SIDE <br /> r " STRUCTURAL ENGINEER <br /> %� 4 �� 7—SOUND ATENUATION 3776 <br /> R-21 INSULATION BATTS BATTS TO FILL WALL REGISTERED <br /> A ; s SHEATHING PER �� CAVITY ARCHITECT <br /> // %��� STRUCTURAL =� /-3-1/2" WOOD STUDS AT 16" <br /> ` s-� WATERPROOFING MEMBRANE �� O.C. - SPECIES PER <br /> .., ,_— -- ANDREW M <br /> / , ; STRUCTURAL ENGINEER III <br /> STATE OF WASHINGTON <br /> ...i,,1�,1 3/4 MASONRY MAT <br /> MI, i;iii0��I BRICK VENEER <br /> g 1w USE WATER RESISTANT <br /> A=:��'M! GYP. BD. IN MOISTURE <br /> JOB NUMBER <br /> PRONE AREAS 14-1o56A <br /> DATE <br /> O*5-1/2" WOOD STUDS 3-1/2" WOOD STUDS 5,20/gaito <br /> 1• • 1'-0• .r a 1'-Q. DRAWN BY <br /> ( y\ CHECKED BY <br /> 5-1/2 WOOD STUDS AT 16 <br /> H <br /> 4 ! 1 <br /> ��� �%� O.C. - SPECIES PER '� � �_�y �, K�� �'���-`' <br /> � m�'s STRUCTURAL ENGINEER 1 �4 1►� 5/6" TYPE 'X' GYP. BOARD y `�"� `"' <br /> . 5/8 TYPE 'X' GYP, BOARD SHEET TITLE <br /> '° ���1��� TYP. EACH SIDE <br /> o R-21 INSULATION BATTS ' <br /> TYP. EACH SIDE ►A <br /> �►� \ —� MAY 2 9 2019 <br /> F �► WOOD SHEATHING PER ? ' . �3 <br /> ��� �`', STRUCTURAL �� SOUND ATENUATION �� SOUND ATENUATION <br /> MSV-ONE <br /> BATTS TO FILL WALL � BATTS TO FILL WALL CH `r OF EVERETT WALL <br /> 5/8" TYPE 'X' GYP. BOARD CAVITYPermit ervices T'11'`PES <br /> SIDE 5-1/2" WOOD STUDS AT 16" W4 3-1/2" WOOD STUDS AT 16" <br /> .ln� A O.C. - SPECIES PER ► • O.G. - SPECIES PER <br /> c <br /> � ������, EXISTING 8x4x16 STRUCTURAL � STRUCTURAL ENGINEER �� STRUCTURAL ENGINEER <br /> �NIF••-�`�0 BRICK, FIRESTOP ALL ) __/r <br /> 4 PENETRATIONS, �g1 •• USE WATER RESISTANT <br /> iii <br /> e. <br /> '� 1A USE WATER RESISTANT SHEET NUMBER <br /> �� GYP. BD. IN MOISTURE W . <br /> k PRONE AREAS GYP. BD. IN MOISTURE <br /> NOTE: 4HR FIRE RESISTANCE ��°�\ <br /> W <br /> PRONE AREAS <br /> RATING PER IBC TABLE 721.1 <br /> A (E) 8" MASONRY WALL 5-1/2" WOOD STUDS 3-1/2" WOOD STUDS A8 • O '_ <br /> ®T , 1.-0• I D1 r ■ 1'-o• (Dr ■ 1 -0die <br /> v\, " iil <br />