FLAG NOTES THIS SHEET
<br /> >> EXCAVATE AND INTERCEPT EXISTING UNDERGROUND o
<br /> CONDUIT AND LIGHTING CIRCUITS. EXTEND NEW CS W o°
<br /> CONDUIT UNDERGROUND TO NEW PANEL C LOCATION. _ °-, �-
<br /> RE-PULL EXISTING CIRCUITS AS REQUIRED AND co
<br /> N U1 0
<br /> TERMINED CIRCUITS IN NEW PANEL C BREAKERS. _ �;co N R . M . E.
<br /> 2> DEMO EXISTING PANEL E, EXTEND OR RE-ROUTE ALL CU 40 v �- R. MARTIN
<br /> EXISTING CIRCUITS TO NEW PANEL E. 5 ,..,O ELECTRIC, INC.
<br /> (1) b C� ELECTRICAL
<br /> tincT CONTRACTORS
<br /> C PO' EXISTING LIGHTING CONDUIT ROUTED ON TOP OF ROOF b. 7 c'- 3615LYNNWOOD, WAS 980
<br /> 0 � � ,� 98037
<br /> DECKING. REMOVE EXISTING WIRE AND INSTALL NEW `� 10 (425) 742-0852
<br /> L� FAX (425) 742-0929
<br /> WIRE AS NOTED. to .. r-
<br /> _> NEW LIGHTING CONDUIT ROUTED ON TOP OF ROOF - co 0
<br /> DECKING. INSTALL NEW WIRE FOR NORMAL OR in
<br /> i CI)
<br /> CT)
<br /> 11)
<br /> lir)
<br /> CI)
<br /> 7 EMERGENCY LIGHTING CIRCUIT AS NOTED. CD o o
<br /> II>- PROVIDE AND INSTALL 6x6x4 n1 PULL/SPLICE CAN WITH W a a
<br /> ,.,
<br /> _\_
<br /> \ FLUSH COVER. INSTALL NEW HOME RUN CONDUIT &
<br /> CIRCUITS TO PANEL E TO RE-FEED EXISTING EXTERIOR
<br /> LIGHTING CIRCUITS.
<br /> I I I I I I I > RELOCATE CONFESSIONAL "OCCUPIED" SIGNAL LIGHT
<br /> � AND WIRE TO CONTROL RELAY LOCATION.
<br /> / PO- PROVIDE A NEW RIBMO12NDC OPEN RELAY MOUNTED IN zin
<br /> in
<br /> 7 A DEEP 4-11/16 BOX AS CLOSE TO THE FLOOR AS
<br /> T / POSSIBLE. PROVIDE WITH BLANK COVER TO CONTROL I�-'
<br /> — 1 — — _ 120V CONFESSIONAL OCCUPIED SIGNAL LIGHT.A Ad 1,C,11 1(.(d444444.F. d 1,1,d,,, Id dl(1dd.Ld '''U'Ld_ dd4f- .A. b.A..A..A.. /'f444444C <..1.b.6d.lJC A.ld(<. l.1LGd l.._.
<br /> ►V 8> RELOCATE EXISTING "KNEEL PAD" LOW VOLTAGE
<br /> - ��i 26 �i 26 411131261 ���26IMMM EXIST
<br /> 'NIL EX CONTROL SWITCH AND CONNECT IT TO THE z
<br /> �� ,S
<br /> 22 8 a;;`;' _ T EXIST RIBMO12NDC RELAY N/O INPUT. 0 o
<br /> PNL B
<br /> PNLE-z2,2426 �n �> DISCONNECT AND REMOVE THE EXISTING PANEL EX cc ±
<br /> (6)#12CU 122 i.''°° , I I I I I_ I SUPPLY CIRCUIT FROM PANEL MDP. INSTALL A NEW 20A ui
<br /> APNL B-26.2: L�J
<br /> ,i 24 6 0 (2)#12CU 120V 20A CIRCUIT FROM THE NORMALLY-ON OUTPUT OF o
<br /> L — THE BATTERY BACK UP LIGHTING INVERTER ILA TO °'
<br /> / RE-FEED PANEL EX. o
<br /> _ L _ ___ __. _ 4
<br /> PN E IIL 26 — _ 10 20A 120V CIRCUIT, DISCONNECT SWITCH AND
<br /> 0 _
<br /> �' 1" j a ` EXIST
<br /> I CONNECTION TO GAS FURNACE LOCATED ABOVE Q
<br /> ro
<br /> ,�,s 22 l —PNL°P STORAGE ROOM. CONFIRM EXACT LOCATION WITH
<br /> EXIST
<br /> (� — — — -i PNL MECHANICAL CONTRACTOR.
<br /> N� q I EXST MDP1 11 20A 120V CIRCUIT AND CONNECTION FOR HVAC
<br /> 13 pPNLF
<br /> CONTROLS TRANSFORMER. LOCATED ABOVE STORAGE
<br /> �� I I I I \ _ I ® / I ROOM. CONFIRM EXACT LOCATION WITH MECHANICAL
<br /> 22
<br /> el
<br /> CONTRACTOR.
<br /> I
<br /> •I 12 20A 208V CIRCUIT, DISCONNECT SWITCH & CONNECTION
<br /> O — i — — — — E — — — — — — — — , _ — — — FOR NEW WHEEL CHAIR LIFT. CONFIRM VOLTAGE AND
<br /> PHASE REQUIREMENTS WITH INSTALLER. MAKE FINAL
<br /> CONNECTIONS TO LIFT.
<br /> I I I I I I -? I IMO. AT THE SUB BASEMENT MECHANICAL ROOM BELOW;
<br /> a 16 PROVIDE A NEW 30A 3P FUSIBLE DISCONNECT SWITCH
<br /> FOR EXISTING AIR HANDLER CIRCUIT. INSTALL MOTOR
<br /> CONTROLLER FURNISHED BY MECHANICAL FOR NEW AIR
<br /> ` 1 / 1
<br /> , HANDLER UNIT. RUN NEW CONDUIT OVERHEAD AND TO
<br /> O — .. — — — — — — — — — — — — —
<br /> AIR HANDLER POINT OF CONNECTION. COORDINATE Z
<br /> I I I I I I I I ( I EXACT REQUIREMENTS WITH MECHANICAL O
<br /> CONTRACTOR.
<br /> F-_
<br /> 0
<br /> CI
<br /> O 1 ),""
<br /> — — I — — I I - I — I — I I - — I — — I Q
<br /> E Q
<br /> Z
<br /> W
<br /> G 16
<br /> 1 ry J
<br /> I I I I I I I , I Lii Qr-N 0�0
<br /> <1/4,,k,
<br /> CD
<br /> ,, I O ( W
<br /> 0 — — ED — - — • — — Iz a > a
<br /> M Q
<br /> I I * I I I I I I I - `� I >
<br /> ,�,16 w c I- I .WIi
<br /> LI
<br /> a r . W
<br /> r. E
<br /> r
<br /> re,
<br /> 16 16 'I II V - % T W
<br /> 0 *
<br /> -I3 — r — --11- — . ),11
<br /> V
<br /> / 14 14 , PNLE-2426 p271
<br /> / II: PN 14,16 (4)#12 CU - _--.lr""
<br /> I,I
<br /> , 14 III (4)•12C PNL E6,11
<br /> r
<br /> / o`' (6)#12 CU
<br /> III '. .,, 1111,1
<br /> `'..26 I6
<br /> r
<br /> 7 I FI � ,. r � I I I I I I rrA711 I,
<br /> / 74 �_/, 3"I PNLE611 �� . „
<br /> .'„, a- 14 10 ,
<br /> L
<br /> 41
<br /> f 14 '1 14 ilk "t ', 24 24 24 24 24 M ,z+ 1 �y ,
<br /> a �y.,(
<br /> ra
<br /> .ti ..W.wa.. Mu wH.NH��..._ �.w.,.�...:. ,w.�.�,� .......W H ..�....�.�.....:,.. :am.�., ww�.a�a r:»�w.w w..
<br /> •
<br /> 0 _ rrrrzrddr drr�r�dr>d� 1Pr'r rrrrr7�rrr ry >rrs r�*s rddrsrr � ....I�I'i`�r rfirr-1,---,--.,��I�i`13ii2rlr 1ir�•ld '0 "�` _..__ .. . ..._._ 14 � �' ...
<br /> III
<br /> III a
<br /> III
<br /> JOB. NO.
<br /> 0000
<br /> I I I I I I I I I I DATE
<br /> 05/01 /2019
<br /> / r �, t
<br /> 1 I I I I 1 I 0 i 0MAY 29 2019 M
<br /> EBB1234567O to CITY OF EVERETT Div
<br /> Permit Services _CK�
<br /> SHEET NO.
<br /> MAIN FLOOR POWER PLAN
<br /> SCALE 8" = 1'-0"
<br /> E 2 • 1
<br />
|