1 1 I 1 <br /> PARTS NOTES h m ith <br /> s oes <br /> A. HYDRANTS AND ALL MATERIALS SHALL CONFORM TO 18" 18" 1. CONCRETE SHALL BE CLASS 3000. <br /> AWWA STANDARDS AND SHALL BE OF STANDARD <br /> MANUFACTURE(MUELLER SUPER CENTURION#250, ail © 2. INSTALL 1/2"x4" EXPANSION STRIP AROUND HYDRANT. <br /> WATEROUS PACER#WB67,OR CITY APPROVED <br /> C OX <br /> EQUAL). �_ 3. GUARD POSTS SHALL BE 6' LONG,9"IN DIAMETER <br /> x PRECAST CONCRETE OR 6' LONG,6" DIAM SCH 40, r h i t ^ c t `� <br /> B. 5-1/4"VALVE MINIMUM. ;I ° g w TWO COATSIOF KELLY-MOORE OREELUXLITE Q.D. ALKYD <br /> WITHD a <br /> G JIll� <br /> C. 1 1/4"OPERATING NUT AND CAP NUT FOR 2-1/2" �' `�' 1 1 /• GLOSS ENAMEL#6100 516 CAT YELLOW OR CITY 1928 43rd Ave E., Ste A <br /> PORTS. ' " • APPROVED EQUAL. <br /> MAX RAKE, 1 4 PER FT fll�l `J Seattle , WA 9 8 1 1 2 <br /> 0 j / � 206 ) 453 - 4053 <br /> / FROM GROUND LEVEL WOK �M �� 4. TOP OF GUARD POST SHALL BE LEVEL WITH TOP OF <br /> j D. NATIONAL STANDARD THREAD ON 2 1/2 PORTS. ._..�.� ..��� oo PUMPER PORT. s h o e s m i t h c o x . c o m <br /> 1 E. 5"STORZ FITTING WITH NATIONAL STANDARD THREAD N11 <br /> 2"CRUSHED 5. VALVE MARKER POST SHALL BE 42" PORTABLE TRAFFIC <br /> I 1 ON THE 4-1/2" PORT. SURFACING DELINEATOR POST W/TWO REFLECTOR STRIPS. THEY <br /> I F. IF HYDRANT RISES THROUGH CONCRETE, USE © TOP COURSE SHALL BE FURNISHED NEW AND UNUSED AND BURIED <br /> E EXPANSION STRIP AROUND HYDRANT BARREL, PER STD 24 DEEP,TO LEAVE 18" EXPOSED AS A MARKER POST <br /> II ,I - PLAN 509. IN ADDITION, INSTALLATION OF THE ELEVATION PLAN THE LETTER V AND THE DISTANCE TO THE VALVE <br /> HYDRANT ON PRIVATE PROPERTY SHALL EQUAL OR <br /> SHALL BE STENCILED ON THE POST WITH 2" HIGH <br /> At EXCEED THE STANDARDS FOR INSTALLATION OF NUMERALS,WITH BLACK ENAMEL PAINT. <br /> TRAFFIC SAFETY PUBLIC FIRE HYDRANTS IN THE CITY OF EVERETT. 6. VALVE MARKER POSTS SHALL BE INSTALLED FOR ALL <br /> n FEATURE BREAK OFF VALVE BOX AND EXTENSION PER FIRE HYDRANT CONCRETE PAD VALVES LOCATED IN UNIMPROVED OR UNPAVED <br /> STANDARD DRAWING 505 G. PROVIDE FOR VEHICULAR TRAFFIC PROTECTION WHEN <br /> FLANGE, BREAK OFF (SEE NOTES 1 AND 2) AREAS.VALVE MARKER POSTS SHALL BE SET AS <br /> � �v Y Y v NUTS AND BOLTS NECESSARY PER STANDARD DRAWING 508. DIRECTED BY THE PUBLIC WORKS INSPECTOR IN A SAFE <br /> \ ��/` �\\\j\ H. STEAMER PORT TO BE FACING STREET OR ROADWAY AND REASONABLY CONSPICUOUS LOCATION. <br /> FOR FIRE ENGINE ACCESS. <br /> 7. VALVE MARKER POSTS ARE NOT REQUIRED FOR <br /> 1/2 CU YD WASHED ROCK F 1 I. BREAK OFF FLANGE TO BE 2" 4"ABOVE GROUND GUARD POST r CONC HYDRANT PAD AUXILIARY HYDRANT VALVES. <br /> 1 1/2" DRAIN ROCK 1 DUCTILE IRON TEE LEVEL. 0 <br /> " GLANRETADS R TAPPING FTEEE(FL) J. INSTALL CONCRETE PAD AROUND HYDRANT IN 36" / <br /> \ . ' _ f �` _ O �O UNPAVED,SOD AND ASPHALT AREAS PER STANDARD _ j / <br /> \/ r .. E. a e _ s / �\ DRAWING 508. 0 I <br /> .• : .• .• <br /> • <br /> �L��T�� ��tW%IW - O f K. HYDRANT CONNECTION PIPE TO BE DUCTILE IRON i i N 1 bethany <br /> •••••••••••�•••!••a = ° ° �' �' CLASS 52,ANY INTERMEDIATE JOINTS TO BE MJ WITH IIII" p :: <br /> 3 / ji�Li ��'- C--} ii ,y <br /> o 11 <br /> RETAINER GLANDS,OR FIELD LOCK GASKETS. I . . , skilled nursing <br /> o \\ --\ L. FIRE HYDRANTS SHALL BE PAINTED WITH TWO COATS P `J <br /> K OF HIGH GLOSS CATERPILLAR YELLOW, LUXLITE i _ `_ NO <br /> - additions <br /> = <br /> #6100-516 OR"RUST-OLEUM"#7448 OR APPROVED 3 = a <br /> Z12"x 12"x 4" GATE VALVE EQUAL.THE PORT CAPS WILL BE PAINTED BLACK. '� <br /> z CONC BLOCK W <br /> o \\ (MJ x FL) M. PROVIDE FORA MINIMUM OF 3' CLEAR ZONE AROUND 9 36" <br /> ,, 6 MIL PLASTIC SHEETING WRAP HYDRANT. > 2235 Lake Heights Drive <br /> 0 <br /> o UNDISTURBED EARTH ELEVATION PLAN Everett, WA 98208 <br /> N GUARD POST <br /> CITY OF EVERETT o CITY OF EVERETT <br /> 0V <br /> z PUBLIC WORKS DEPARTMENT z PUBLIC WORKS DEPARTMENT <br /> Z Z FIRE HYDRANT GUARD POSTS VALVE MARKER POST <br /> W W <br /> o 2 ''RYAN SASS RHEFTI•a• `APAUL WILHELM Dr""%RB `°5/I�9 2018 o a (SEE NOTES 3 AND 4) a"'IZZ s�r-o.M.�•.•, CEO,k11per D.awoev c�rrem R�D•re <br /> V m STANDARD DRAWING WING Na. N (SEE NOTES 5, 6 AND 7) RVAN SASS RHEFTI PAUL WILHElM WRB 12/30/2016 <br /> V a TITLE FIRE HYDRANT <br /> FIRE HYDRANT w STANDARD DRAWING NT.4o <br /> w,, 5f CONC. PAD, GUARD POSTS & 508 <br /> Ea INSTALLATION 507 Egr <br /> b, VALVE MARKER <br /> I r -- -I I KEYMAP <br /> FIRE H DRANT ASSEMBL0 <br /> Bethany <br /> NOT TO SCALE <br /> of the Northwest <br /> NO. DATE REVISION <br /> CIT 1 OF E ERETT WATER NOTES WATER NOTES DOH CRS <br /> 1 01-28-2019 RESPONSE 01 <br /> A. NO CONNECTION TO THE EXISTING MAINS WILL BE ALLOWED 1. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE FORM CONCRETE TO CITY OF EVERETT <br /> EXCEPT BY MEANS OF AN APPROVED BACKFLOW PREVENTION CITY OF EVERETT, THE LATEST REVISIONS OF AWWA, THE ALLOW FOR REMOVAL 3 03.29-2019 RESPONSE 0 1 (BLDG) <br /> DEVICE PRIOR TO SATISFACTORY FLUSHING, TESTING, STANDARD SPECIFICATIONS FOR ROAD, BRIDGE, AND MUNICIPAL OF BOLTS CITY OF EVERETT <br /> DISINFECTION, AND RECEIPT OF SATISFACTORY CONSTRUCTION BY WASHINGTON STATE D.O.T. AND 4 04.29-2019 RESPONSE 01 (PW) <br /> BACTERIOLOGICAL TEST RESULTS. WASHINGTON STATE CHAPTER A.P.W.A. .4 w <br /> <. 20 LB. TAR PAPER CITY OF EVERETT <br /> B. CONNECTIONS TO AND TAPS ON EXISTING MAINS WILL BE MADE 2. THE CONTRACTOR SHALL COMPLY WITH ALL THE REQUIREMENTS f 5 05.31-2019 RESPONSE 02(PVC <br /> BY THE PUBLIC WORKS DEPARTMENT AT THE DEVELOPER'S <br /> OF STATE AND LOCAL HEALTH AUTHORITIES. <br /> ,-- <br /> EXPENSE. THE PUBLIC WORKS DEPARTMENT SHALL BE GIVEN AT < W <br /> LEAST 5 BUSINESS DAYS NOTICE FOR EACH CONNECTION. THE 3. THE ROAD AND STRUCTURE LOCATIONS SHOWN ARE -I 1111 p fro (� <br /> PUBLIC WORKS DEPARTMENT SHALL THEREAFTER DETERMINE , I <br /> THE DATE AND TIME AT WHICH THE CONNECTION SHALL BE APPROXIMATE AND INTENDED TO SHOW THE RELATIVE e i M0. <br /> MADE. LOCATION OF THE PROPOSED WATER SYSTEM ONLY. <; D <br /> C. ALL WORK AND MATERIALS MUST CONFORM TO CITY OF 4. ALL LOCATIONS OF EXISTING UTILITIES ARE APPROXIMATE AND IT '�'N. ` UNDISTURBED EARTH <br /> EVERETT STANDARDS. SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY <br /> D. A PRE-CONSTRUCTION MEETING SHALL BE HELD WITH THE CITY THE EXACT LOCATION TO AVOID DAMAGE OR DISTURBANCE. <br /> 2000# � 28 DAYS PROJECT MANAGER <br /> PRIOR TO THE START OF CONSTRUCTION. THE CITY OF EVERETT 5. ALL DUCTILE IRON PIPE AND FITTINGS SHALL BE CEMENT LINED. PLAN CONCRETE, POURED IN ELEVATION PROJEDTUENGINEER <br /> PUBLIC WORKS CONSTRUCTION DIVISION MUST BE NOTIFIED AT <br /> LEAST 24 HOURS PRIOR TO COMMENCEMENT OF PLACE <br /> 6. THE MINIMUM COVER FOR WATER MAINS SHALL BE 3' AND SHALL TEIM <br /> CONSTRUCTION. <br /> BE MAINTAINED AT ALL POINTS. 1. BEARING AREA TABLE BASED ON 200 PSI PRESSURE AND 2000 PSF PROJECT TEAM MEMBERS <br /> E. THE DEVELOPER OR THE DEVELOPER'S AUTHORIZED AGENT SOIL BEARING. IF PRESSURE IS GREATER OR SOIL BEARING IS LESS, RES <br /> SHALL NOTIFY THE PUBLIC WORKS DEPARTMENT OF A PERSON 7. INSTALLATION OF WATER MAINS AND SERVICE LINES SHALL THE THRUST BLOCK SIZE SHALL BE INCREASED. CHECK <br /> WHO CAN BE CONTACTED REGARDING PROBLEMS DURING INCLUDE LOCATOR WIRE BURIED ALONG THE ENTIRE LENGTH OF DCN <br /> CONSTRUCTION ON A 24 HOUR BASIS. THE PIPE. LOCATOR WIRE TO BE 14 GAUGE. LOCATOR WIRE TO 2. THIS TABLE REPRESENTS THE "MINIMUM" CONSTRUCTION <br /> F. MAINTAIN A MINIMUM OF 10 FEET HORIZONTAL AND 18 INCHES BE RUN TO 12"ABOVE GROUND AT EACH METER, BLOW OFF, AND STANDARDS. THE ENGINEER SHALL BE RESPONSIBLE FOR <br /> VERTICAL SEPARATION BETWEEN POTABLE AND NON-POTABLE AIR/VACUUM VALVE. ALL SPLICES IN THE LOCATOR WIRE SHALL DETERMINING THE APPROPRIATE SIZE OF ALL THRUST BLOCKS BASED <br /> BE MADE USING A 3M DIRECT BURY SPLICE KIT, MODEL DBY. THE ON EXISTING AND LOCAL CONDITIONS. SEAL <br /> CONVEYANCE SYSTEMS. KIT SHALL BE INSTALLED PER MANUFACTURER'S <br /> G. ALL CITY OF EVERETT VALVES SHALL BE OPERATED BY PUBLIC SPECIFICATIONS. THE WIRES SHALL BE TIED IN A KNOT 6"TO 8" <br /> WORKS DEPARTMENT PERSONNEL ONLY. ALL VALVES, NEW AND FROM THE SPLICE. -,ISTOph, <br /> EXISTING, SHALL BE ACCESSIBLE AT ALL TIMES. MINIM_7M BEARING AREA TABLE • <br /> K��of wAs8i4,,L�'�� <br /> 8. ALL FIRE HYDRANT SHALL INCLUDE AN APPROVED 5" STORZ <br /> ADAPTER ON THE PUMPER PORT. FITTING TEE 90 45 22 1/2 111/4 n <br /> 0- �Pr -' rr " cr <br /> 4" 4 SQFT 5 SQFT 3 SQFT 2 SQFT 1 SQFT ` <br /> - / <br /> 9. GATE VALVES SHALL BE RESILIENT-SEATED GATE VALVES �o Q'r /' <br /> CONFORMING TO AWWA C-509. ALL EXISTING VALVES SHALL BE 6" 4 SQFT 6 SQFT 3 SQFT 2 SQFT 2 SQFT le, ,E�Is3,3go `�' <br /> PRESSURE TESTED BY THE CONTRACTOR PRIOR TO <br /> CONNECTION. 8" 7 SQFT 10 SQFT 6 SQFT 3 SQFT 2 SQFT SSIONALOs\ <br /> 10.ALL CUTTING, TAPPING, REMOVAL AND DISPOSAL OF ASBESTOS <br /> 10" 10 SQFT 15 SQFT 9 SQFT 5 SQFT 3 SQFT 5/31/2019 <br /> CEMENT PIPE SHALL BE IN CONFORMANCE WITH THE CURRENT 12„ 14 SQFT 22 SQFT 12 SQFT 6 SQFT 4 SQFT „ <br /> POLICIES AND PROCEDURES OF THE SNOHOMISH COUNTY <br /> HEALTH DEPARTMENT, THE PUGET SOUND AIR POLLUTION 16" 25 SQFT 38 SQFT 21 SQFT 11 SQFT 7 SQFT WATER DETAILS <br /> CONTROL AGENCY AND OTHER PUBLIC OFFICES WITH <br /> JURISDICTION IN THIS MATTER. AT THIS TIME THE POLICY IS 18" 32 SQFT 48 SQFT 27 SQFT 14 SQFT 8 SQFT <br /> THAT: Civil Engineers <br /> 20" 69 SQFT 98 SQFT 53 SQFT 27 SQFT 14 SQFT <br /> A. A PIPE SHALL BE "SNAPPED OFF" RATHER THAN BEING CUT Structural Engineers ■ <br /> WITH ABRASIVE SAW. 24" 98 SQFT 139 SQFT 75 SQFT 39 SQFT 20 SQFT Landscape Architects <br /> B. ABANDONED PIPE SHALL BE BE LEFT IN THE TRENCH OR Community Planners _, <br /> Air <br /> DISPOSED OF IN AN APPROVED METHOD. <br /> Natural Resource Ecologists� <br /> Land SurveyorsNib PROJECT NO. <br /> 11.ABANDONED WATER MAINS SHALL BE LEFT IN THE THE GROUND T H R ST BLOC I N G Neighbors 18.03-01 <br /> UNLESS THEY MUST BE REMOVED BECAUSE OF CONFLICT. THE DATE <br /> ENDS SHALL BE PLUGGED WITH CONCRETE. NOT TO SCALE 12/21/2018 <br /> �v� <br /> A F-I PROJECT NETWORK PATH <br /> 12.ABANDONED VALVES SHALL HAVE THE OPERATOR NUT CUT OFF <br /> El . AND THE VALVE BOX REMOVED. <br /> 13.CONTRACTOR SHALL COORDINATE AND PROVIDE ALL THE T A C O M A • S E A T T L E <br /> Q 1 /� NECESSARY POWER/FIRE SYSTEM MONITORING WIRING. S P O K A N E • T R I - CITIES SHEET NUMBER <br /> l'/� 2215 North 30th Street, Suite 300 Tacoma, WA 98403 <br /> 14.CONTRACTOR SHALL PROVIDE GRAVITY DRAIN OR SUMP PUMP 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB <br /> Know what's below. AND FORCEMAIN DRAIN TO ALL VAULTS. COORDINATE POWER C I <br /> C3 • 14 <br /> FOR SUMP PUMP AS REQUIRED. NOT EQR CO N S T R U C T I O N Call before you dig. PERMIT SET <br /> COPYRIGHT© 2018 shoesmith cox architects <br /> DATE: May 30, 2019 FILENAME: Q:\2018\2180406\10_CIV\CAD\2180406-SH-STRM.dwg <br />