Laserfiche WebLink
• 1 <br /> 0 .' ., <br /> architects (-) <br /> 1928 43rd Ave E., Ste A <br /> Seattle , WA 98112 <br /> GENERAL LANDSCAPE NOTES PLANTING SPECIFICATION ( 2 0 6 ) 453 . 4053 <br /> shoesmithcox . com <br /> 1. SEE L1.02 FOR PLANT SCHEDULE. BMP T5.13: POST-CONSTRUCTION SOIL QUALITY AND DEPTH <br /> 1. A TOPSOIL LAYER WITH A MINIMUM ORGANIC MATTER CONTENT OF <br /> 2. PLANTING SHALL CONFORM TO ALL EVERETT CODE REQUIREMENTS, INCLUDING 10% DRY WEIGHT IN PLANTING BEDS AND 5% ORGANIC CONTENT IN <br /> PRESERVATION OF ADEQUATE INTERSECTION SIGHT DISTANCE LINES/TRIANGULAR AREAS. TURF AREAS, WITH A pH FROM 6.0 - 8.0 OR MATCHING THE pH OF <br /> THE UNDISTURBED NATIVE SOIL. <br /> 3. CONTRACTOR SHALL VERIFY ON-SITE CONDITIONS PRIOR TO BIDDING AND CONSTRUCTION. <br /> 2. THE TOPSOIL LAYER SHALL HAVE A MINIMUM DEPTH OF EIGHT , <br /> 4. INSTALL AUTOMATIC UNDERGROUND IRRIGATION SYSTEM IN ALL NEW AND RENOVATED INCHES EXCEPT WHERE TREE ROOTS LIMIT THE DEPTH OF <br /> LANDSCAPE AREAS. MAINTAIN WATER SUPPLY TO EXISTING SYSTEM DURING GROWING INCORPORATION OF AMENDMENTS NEEDED TO MEET THE <br /> SEASON. CRITERIA. <br /> 5. THE CONTRACTOR AND OWNER ARE RESPONSIBLE FOR READING THE PLANS, 3. SUBSOILS BELOW THE TOPSOIL LAYER SHALL BE SCARIFIED AT <br /> SPECIFICATIONS AND NOTES. LEAST FOUR INCHES WITH SOME INCORPORATION OF THE UPPER <br /> MATERIAL TO AVOID STRATIFIED LAYERS, WHERE FEASIBLE. <br /> 6. THE CONTRACTOR SHALL VERIFY ALL PLANT MATERIAL QUANTITIES PRIOR TO INSTALLATION. <br /> ANY PLANT MATERIAL QUANTITIES LISTED ARE FOR THE CONVENIENCE OF THE CONTRACTOR. 4. PLANTING BEDS SHALL BE MULCHED WITH 2 INCHES OF ORGANIC <br /> ACTUAL NUMBER OF SYMBOLS SHALL HAVE PRIORITY OVER QUANTITY DESIGNATED. THE MATERIAL. <br /> CONTRACTOR SHALL BE RESPONSIBLE FOR COUNTING THE TOTAL NUMBER OF PLANTS <br /> INDICATED ON THE PLANS AND ESTIMATING GROUNDCOVER QUANTITIES. 5. MULCH TO BE FREE OF DELETERIOUS MATERIALS AND SUITABLE <br /> AS A TOP DRESSING OF TREES AND SHRUBS, CONSISTING OF <br /> 7. THE CONTRACTOR SHALL FURNISH AND PAY FOR ALL CONTAINER OR FIELD GROWN TREES, COMPOSTED AGED (MIN. 1 YEAR) FIR OR HEMLOCK BARK CHIPS <br /> SHRUBS AND GROUNDCOVERS, INCLUDING SEEDED AND SODDED TURF, HYDROMULCHES AND TO BE DARK(BLACK) IN COLOR. COMPOST MULCH TO BE <br /> AND FLATTED GROUNDCOVERS. THE CONTRACTOR SHALL ALSO BE RESPONSIBLE AND PAY WELL-COMPOSTED, STABLE AND WEED-FREE ORGANIC MATTER :a a <br /> FOR: PLANTING OF ALL PLANT MATERIALS; THE SPECIFIED GUARANTEE OF ALL PLANT WITH ORGANIC MATTER COMPRISING 50 TO 60 PERCENT OF DRY <br /> MATERIALS; THE STAKING AND GUYING OF TREES AND THE CONTINUOUS PROTECTION OF ALL WEIGHT. <br /> PLANT MATERIALS UPON THEIR ARRIVAL AT THE SITE. skilled nursing <br /> 6. TOP OF MULCH SHALL BE FLUSH WITH FINISH GRADES. DO NOT <br /> 8. MINIMIZE DISTURBANCE OF EXISTING PLANTING TO REMAIN. WHEN INFILL PLANTING AROUND PLACE MULCH WITHIN 2 INCHES OF TRUNKS OR STEMS. additions <br /> EXISTING PLANTING, DIG ONLY AS NEEDED PER INDIVIDUAL PLANT. TYPICAL SOIL <br /> PREPARATION DOES NOT APPLY TO THESE AREAS. APPLY 2" LAYER OF MULCH. PREPARATION: <br /> 1. CLEAN SOIL OF CONCRETE SLURRY, CONCRETE LAYERS OR <br /> CHUNKS, CEMENT, PLASTER, BUILDING DEBRIS, OILS, GASOLINE, 2235 Lake Heights Drive <br /> DIESEL FUEL, PAINT THINNER, TURPENTINE, TAR, ROOFING <br /> COMPOUND, ACID AND OTHER EXTRANEOUS MATERIALS THAT ARE <br /> HARMFUL TO PLANT GROWTH. Everett, <br /> WA 98208 <br /> PLACING MANUFACTURED PLANTING TOPSOIL OVER EXPOSED <br /> SUBGRADE: <br /> 2. APPLY AND MIX APPROXIMATELY HALF THE THICKNESS OF <br /> TOPSOIL OVER PREPARED, LOOSENED SUBGRADE. SPREAD <br /> REMAINDER OF TOPSOIL. <br /> 3. SPREAD UNAMENDED SOIL TO TOTAL DEPTH REQUIRED TO MEET <br /> FINISH GRADES AFTER NATURAL SETTLEMENT. DO NOT SPREAD IF <br /> SOIL OR SUBGRADE IS FROZEN, MUDDY, OR EXCESSIVELY WET. <br /> 4. APPLY AND MIX TOPSOIL IN LIFTS NOT EXCEEDING 8 INCHES IN , <br /> LOOSE DEPTH FOR MATERIAL COMPACTED BY COMPACTION __ — <br /> EQUIPMENT, AND NOT MORE THAN 6 INCHES IN LOOSE DEPTH FOR <br /> p or <br /> MATERIAL COMPACTED BY HAND-OPERATED TAMPERS. <br /> of t t <br /> NO. DATE REVISION <br /> 10 1/28/2019 DOH CRS Response#1 <br /> CITY OF EVERETT <br /> A\ 4/29/2019 RESPONSE#1 (PW) <br /> • CITY OF EVERETT <br /> O 5/31/2019 RESPONSE#2 (PW) <br /> PROJECT MANAGER <br /> CT <br /> PROJECT ARCHITECT <br /> PROJECT TEAM MEMBERS <br /> MS, BV <br /> CHECK <br /> CS <br /> ARCHITECT SEAL <br /> ®F W A S,1 <br /> ,y, P\o R. Sk//J of <br /> is 4 <br /> T 0fc J V� � ;�- . <br /> 4 <br /> f2 za <br /> sC p E ARG� <br /> 05.31 .2019 <br /> TITLE <br /> LANDSCAPE , <br /> Civil Engineers ,E_ � SPECIFICATION <br /> p 1 <br /> Structural Engineers ,,_ �"�� `-�°utg',��, <br /> �,.<.. :�.`.ter, <br /> Landscape Architects ,kp '.''t4" ,.�_tv,_ <br /> Community Planners • ,,,, t ,,4 & NOTES <br /> Natural Resource Ecologists . • ` A': `` " , {. <br /> I ��;;� PROJECT NO. <br /> Land Surveyors x pli���� m�s�41,1�•' p���3 <br /> Neighbors 4 k � v s 18. 3-01 <br /> '' a; DATE <br /> 1w . , 5/06/2019 <br /> rrri'i PROJECT NETWORK PATH <br /> TACOMA • SEATTLE <br /> `'a -.-.. -,® S P ® K A !V TRI - CITIES SHEET NUMBER <br /> 2215 North 30th Street, Suite 300 Tacoma, WA 98403 <br /> � , 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEBI II <br /> Know what's below. ' : ' ` PERMIT SET <br /> II before you dig. 0 T • <br /> COPYRIGHT© 2018 shoesmith cox architects <br /> DATE: May 8, 2019 FILENAME: Q:\2018\2180406\40_LAN\CAD12180406-SH-PLANTING PLAN.dwg <br />