ENERGY CODE NOTES ACOUSTIC NOTES PARTITION NOTES 1. IF PARTITION REQUIRES STRUCTURAL SHEATHING FOR SHEAR, IT SHALL 4. CAULK ALL PIPE, CONDUIT, DUCT OR SIMILAR PENETRATIONS THROUGH 1. PARTITION TYPES ARE NOTED ON THE PLANS. THE TAG CONSIST OF 2 5. SUBSTITUTE TILE BACKER BOARD AT TILE FINISHES. h m i h <br /> 1. COMPLY WITH THE 2015 WASHINGTON STATE COMMERCIAL 3. SEE DOOR AND WINDOW NOTES ON A10.02 FOR MAXIMUM DOOR S O S <br /> ENERGY CODE FOR CLIMATE ZONE 4-C(MARINE). AND WINDOW U VALUES PER TABLES C402.1.3 AND C402.4. BE ADDED TO THE EXTERIOR OF WALL FRAMING, U.N.O. APPLY RC PARTITIONS WITH RESILIENT NON-HARDENING CAULK. ELEMENTS: THE ALPHA CHARACTER INDICATES THE PARTITION TYPE <br /> CHANNEL AND SHEAR SHEATHING TO OPPOSITE SIDES OF STUDS. KEYED TO THE SCHEDULE; THE NUMERIC CHARACTER(WHERE 6. ALL GWB IS TYPE-X U.N.O. IF NON-LISTED GWB IS USED INSTEAD OF <br /> 2. PRESCRIPTIVE VALUES FOR ENVELOPE COMPONENTS,TABLE 5. WHERE TWO OR MORE LAYERS OF GWB ARE USED,VERTICAL AND INDICATED)ACTS AS A MODIFIER TO THE TYPE. PROPRIETARY GWB, PROVIDE INFORMATION SHOWING THAT THE GWB <br /> C402.1.3: 2. ALL PARTITIONS SHALL BE SEALED AT FLOOR AND CEILING PLATES WITH HORIZONTAL JOINTS SHALL BE STAGGERED. PARTITION TYPE MEETS REQUIREMENTS OF IBC 703.4. C 0 X <br /> A RESILIENT 20 YEAR NON-HARDENING CAULK IN ACCORDANCE WITH E1 <br /> FENESTRATION U=0.30 ASTM C919. 6. ACOUSTICAL INSULATION SHALL BE UN-FACED. '- ' TYPE MODIFIER 7. INSTALL SOUND SEALANT AT TOP AND BOTTOM OF WALLS WITH i _� <br /> CEILING R-49 RESILIENT CHANNEL AND/OR ACOUSTIC BATT INSULATION i <br /> WALL R-21 arch t o C t S Q <br /> SLAB R-10, 2FT 3. ELECTRICAL BOXES OR OTHER SIMILAR OPENING IN PARTITIONS SHALL 7. STC 50 MIN. REQUIRED BETWEEN DWELLING UNITS PER IBC SECTION 1207 2. UNLESS NOTED OTHERWISE, FACE LAYERS OF ALL SYSTEMS SHOWN ON <br /> NOT BE INSTALLED BACK TO BACK. THIS SHEET SHALL HAVE JOINTS TAPED AND FASTENER HEADS 8. SEE WALL SCHEDULE ON STRUCTURAL DRAWINGS FOR SIZING OF 1928 43rd Ave E., Ste A <br /> TREATED. A STUDS, PLATES, SHEATHING, CONCRETE WALLS, REINFORCEMENT, & Seattle , WA 9 8 1 1 2 <br /> NAILING. ( 2 0 6 ) 453 . 4053 <br /> 3. FIRE RATED ASSEMBLIES ARE BASED ON IBC, UL, OR US GYPSUM <br /> ROOF-CEILING ASSEMBLIES WALL ASSEMBLIES ASSOC. (GA)TEST DATA&ARE TO BE CONSTRUCTED IN ACCORDANCE 9. USE VAPROSHIELD WRAPSHIELD WRB WHERE BUILDING PAPER IS s h o e s m i t h c o x. c o m <br /> , WITH THE REQUIREMENTS OF THE TESTING AGENCIES. REFER TO SPECIFIED. <br /> NEW 5/8" U.L. LISTED TYPE SPECIFIC TEST REPORTS INDICATED FOR REQUIRED COMPONENTS& <br /> 'X' GYPSUM WALLBOARD ASSEMBLY. EXTENTS OF ASSEMBLIES ARE SHOWN ON THE PLANS. 10. SEE SPECIFICATIONS FOR VAPOR BARRIER INFORMATION. <br /> NEW RESILIENT CHANNEL FIRE RATED PARTITIONS FORM A SEPARATION THAT SHALL BE <br /> G 1 NEW 2x4 STUDS AT 16"ON CONTINUOUS FROM FLOOR TO STRUCTURE ABOVE WITH NO BREAKS AT 11. BLOCKING IS REQUIRED AT THE FOLLOWING LOCATIONS: CASEWORK, <br /> E�rl` f <br /> j /� �® d 0//le/ZO2-D CENTER COLUMNS,WALL TRANSITIONS, OR OTHER OBSTRUCTIONS. ALL SHELVING, &PANELING; ACCESSORIES&EQUIPMENT; DOOR <br /> .1-- <br /> d iK' ��/V L 4 o► 1 L�TV EXISTING WALL ASSEMBLY A PENETRATIONS IN FIRE RATED PARTITIONS REQUIRED TO HAVE HARDWARE;TOILET PARTITIONS&ACCESSORIES; GRAB BARS; <br /> PROTECTED OPENINGS SHALL BE FIRESTOPPED PER CS1.01 OR ACOUSTICAL PANELS; &OTHER LOCATIONS WHERE REQUIRED PER <br /> A PROVIDED WITH APPROVED SMOKE &/OR FIRE DAMPERS. MANUFACTURER'S RECOMMENDATIONS OR INDUSTRY STANDARDS. <br /> FIRE RATED PARTITIONS MAY HAVE OPENINGS FOR STEEL ELECTRICAL <br /> GA FILE NO. RC 2609 I I PROPRIETARY* I 1 HOUR EXISTING 5/8"GWB BOXES NOT TO EXCEED 16 SQ INCHES PROVIDED THE AGGREGATE 12. DIFFERING PARTITION TYPES SHALL ALIGN SO THAT WALL PLANES <br /> FIRE EXISTING 2x4 STUDS AT 16" AREA OF ALL BOXES DOESN'T EXCEED 100 SQ INCHES FOR ANY 100 SQ CONTINUE UNBROKEN IN ROOMS, UNO. <br /> WOOD ROOF TRUSSES, RESILIENT CHANNELS, GLASS FIBER r+� FT. OF PARTITION. THE ANNULAR SPACE BETWEEN THE WALL <br /> INSULATION, CEILING DAMPER, GYPSUM WALLBOARD me ON CENTER MEMBRANE AND BOX SHALL NOT EXCEED 1/8". 13. WHERE 2 DIFFERENT CEILING HEIGHTS ABUT A NON-RATED PARTITION, <br /> One layer 5/8" proprietary type X gypsum wallboard or gypsum veneer base applied at right =' ::� NEW RESILIENT CHANNEL THE GWB SHALL EXTEND A MIN OF 6"ABOVE THE CEILING ON EACH SIDE. <br /> angles to resilient furring channels 16" o.c. (12" o.c. when insulation is draped over 'r4- - ACOUSTIC CONNECTION 4. USE 5/8" GLASS FIBER MAT MOISTURE RESISTANT TYPE'X'GWB AT WET AT EXPOSED TO STRUCTURE CEILING SPACES: EXTEND GWB TO <br /> channels or sprayed directlyover gypsum board)with 1"Type S drywall screws 12"o.c. `:-c=== •``= :� i <br /> AREAS, INCLUDING: STRUCTURE. <br /> Yp rY� SYSTEM9 /a" o.c. when insulation is dra ed over �^ PUBLIC, STAFF, & RESIDENT BATHROOMS: WALLS WITHIN 24"OF FRONT <br /> ( p channels). Gypsum board end joints attached ---- .ti.... �•,-_; &SIDES OF WATER CLOSETS& URINALS 14. OUTLET BOXES ON OPPOSITE SIDES OF PARTITIONS TO BE SPACED <br /> with screws 8"o.c.to additional pieces of channel 60"long located 3"back on either side -v:{,_• ►-�� NEW 5/8" U.L. LISTED TYPE <br /> of end joint. Resilient channels applied at right angles to bottom chord of pitched wood •�'' ''' =:,,,- �•� 'X' GYPSUM WALLBOARD TUB/SHOWERS: CEMENTITIOUS BOARD TO 70"ABOVE DRAIN, BEHIND& APART MIN. 24 . <br /> _ _ TO 24" IN FRONT OF TUB/SHOWERS. <br /> trusses 24"s o.c. with 11/4" Type S or W screws. Optional glass fiber insulation secured - --� JANITOR AND UTILITY AND"WET USE"AREAS. 15. PENETRATIONS IN FIRE PARTITIONS TO COMPLY WITH SECTION 714. <br /> to wood structural panels or draped over channels, or cellulose insulation sprayed - , I i �_ , NEW MINERAL FIBER INSULATION <br /> directly over gypsum board.Trusses supporting 15/32"wood structural panels applied at I yam, <br /> right angles to trusses with either construction adhesive and 6d ring shank nails 12"o.c. - - ,`,..-..r__; P� NEW ELECTRICAL AND UTILITY BOXES <br /> Optional ceiling damper(refer to manufacturer for information on the type of damper). I FIRE RATED AND SUITABLE FOR bethany <br /> ACOUSTIC AND FIRE SEALING. <br /> Approx. Ceiling LOCATIONS TO AVOID SAME S UD BAY STAGGER <br /> PROPRIETARY GYPSUM BOARDEXTERIOR WALL ASSEMBLIES <br /> FpCertainTeed Gypsum Inc. - 5/s" ProRoc®Type C Gypsum Panels Weight: 3 psf _ AND SEE PARTITION NOTE#3 ABOVE skilled nursing <br /> Fire Test: UL 60, 07NK25175, MODIFIED EXISTING NOT USED EXT INT <br /> c <br /> 6 24-08 additions <br /> UL Design P538 G 1-HR. INTERIOR WALL H 3 <br /> 2-HOUR FIRE WALL / ,. <br /> ,, <br /> EXTEND WALL FROM SLAB TO UL DES: U336 A 2-HOUR FIRE WALL '2.-",-5/8" U.L. LISTED FIRE RATED TYPE'X'OR'C'GYPSUM 2235 Lake Heights Drive <br /> UNDERSIDE OF ROOF SHEATHING UL DES: U301 '` WALLBOARD <br /> Y ROOF-CEILING AT SLOPED TRUSS ROOF, v �__ , S OOF�R TABLE 1505.1 PER IBC 706.E EXCEPTION 4 SEE 13 OF WALL AT ROOF SHR EATHING NICATION FIRESTOP PENETRATIONS PER CS1.05 , ADD (1) LAYER 5/8" U.L. LISTED FIRE RATED Everett, WA 98208 <br /> 3/4 3/4 TYPE 'X'GYPSUM WALLBOARD TO INTERIOR <br /> FULLY ADHERED 60 MIN T.P.O. ROOFING SYSTEM 2"�� / � -------' EXTERIOR SHEATHING, 1/2" PLYWD SHEER SHEATHING, <br /> PROTECTION BOARD FIRESTOP PER CS1.05 / ' : CC FACE AND SUBSTITUTE FIRE RATED(2-SIDE) <br /> R-38 RIGID INSULATION(3" MIN)TAPERED TO A FIRE RATED, FASTEN PER STRUCTURAL ENGINEER, OSB PANELS FOR EXTERIOR SHEATHING TO <br /> �} NEW 2x6 STUDS AT 16"ON CENTER. '' TAPE AND SEALED AT EXTERIOR FACE. <br /> DRAIN / r, PROVIDE 2 HOUR EXTERIOR BEARING FIRE <br /> 5/8" DENSDECK ROOF BOARD _ STUDS CROSS BRACED MID-HEIGHT ' <br /> f 1"AIR SPACE <br /> WHERE REQ'D FOR CLIP WALL(PROTECTION FROM INSIDE) PER UL <br /> 3/4"WOOD ROOF DECK DESIGN U349 <br /> .e♦ee♦e♦eye♦e♦e♦e♦e♦e♦e♦e♦e♦eee♦♦e♦♦. 2x8 WOOD ROOF JOISTS @ 16" O.C. I ATTACHMENT. 11 4X8X16 SPLIT FACE CMU VENEER-TIE TO FRAMINGA. <br /> ►e0ieeeeeeeeeeee♦eeee♦ i 30 MIL DRY THICKNESS FIREGUARD E-84 EXISTING 2x6 STUDS AT 16"ON - EXIST. 2x4 STUDS AT 16"ON CENTER , ..,.�� <br /> •♦♦♦♦♦♦������♦���•♦�•e♦�♦���• ``� = / / C 2 USE 2X8 STUDS I N LIEU O F 2X6 STUDS <br /> �eeee♦eeeeeeeeeeeeeee4 INTUMESCENT COATING CENTER. CROSS BRACE MID-HEIGHT <br /> ♦e♦e♦ee♦a♦eeeeeeeeeeeeeee♦� WHERE REQ'D FOR CLIP ATTACHMENT. / /� [ <br /> 2X6 STUDS AT BEARING PER STRUCTURAL ENGINEER <br /> EXIST. MINERAL FIBER INSULATION <br /> - <br /> , > 2"WIDE 0.063"THICK ALUMINUM / SE 2X4 STUDS IN LIEU OF 2X6 STUDS <br /> ATTACHMENT CLIPS W/2"&2-1/4"LEGS EXIST. (2) LAYERS 5/8" TYPE'X' / Cl1 FILL CAVITY COMPLETELY WITH MIN R-21 <br /> APPLY 30 MIL DRY THICKNESS FIREGUARD E-84 �� , <br /> GYPSUM WALLBOARD. JOINTS AIR IMPERMEABLE CLOSED-CELL SPRAY B of Ii n INTUMESCENT COATING TO ALL EXPOSED WOOD • METAL"H" STUD, FLANGED, SPACED � - STAGGERED EACH LAYER AND EXT. WALL AT CMU VENEER BLOCK INSULATION IN LIEU OF BATT INSULATION <br /> SURFACES AT BOTTOM OF ASSEMBLY ( 24" ON CENTER, W/1-3/8" FLANGE SIDE. <br /> WIDTH C of the Norathwest <br /> 1-HOUR ROOF ASSEMBLY - (2}LAYERS 1"GYPSUM BOARD111 ,.,,. ,�, , <br /> GUARDIAN FIRE TESTING LABORATORIES INC. r LINER PANELS IN NOM. 24"WIDTHS. `l NO. DATE REVISION <br /> REPORTS EER69113&GL 115411 VERTICAL EDGES OF PANELS ' EXT INT <br /> A <br /> s;- FRICTION FITTED INTO"H"STUDS. 2 HOUR EXTERIOR BEARING FIRE WALL <br /> FIRESTOP PENETRATIONS PER CS1.05 A ill 3' _-.- • PTD FIBER CEMENT BOARD PANEL SIDING,JOINTS <br /> i NEW 5/8" U.L. LISTED TYPE'X' I 1.101 <br /> "� (PROTECTION FROM INSIDE) A°' 2820'9 <br /> DOH CRS RESPONSE#1 <br /> ROOF-C A EMB N OOF - I GYPSUM WALLBOARD.VERTICAL SEALED& PROTECTED PER MANUFACTURER. EXTENT <br /> X CLA ROOF 1 .1 JOINTS LOCATED OVER STUDS. PER ELEVATIONS <br /> UL DES: U349 A°32920"9 <br /> CITY RESPONSE#1 <br /> 2xJ01STS t} (2) LAYERS 5/8" U.L. LISTED FIRE RATED TYPE'X'OR'C' <br /> t �"-� GYPSUM WALLBOARD SEE 5/A8.03 FOR TERMINATION AT ROOF <br /> T.P.O. ROOFING SYSTEM OVER PLYWOOD DECK F INTERIOR 2-HOUR WALL F1 EXISTING INTERIOR 2-HOUR WALL A°5302019 <br /> CITY RESPONSE#2 <br /> 3/4" MODIFIED RAIN SCREEN STRAPPING OVER 1 LAYER <br /> WOOD I JOISTS PER STRUCTURAL ENGINEER <br /> �_ WRB <br /> SECTION CUT SHOWN FOR CLARITY A ni FIRE RATED (2-SIDE)OSB PANELS <br /> I -MIN R-38 BATTS AND BLANKETS OR LOOSE FILL INSUL �� USE 2X8 STUDS IN LIEU OF 2X6 STUDS <br /> . -aillald <br /> 0 Me MIN R-21 HIGH DENSITY FIRE RATED BATT OR BLOWN IN BD PER UL DESIGN U349 <br /> - - - • = INSULATION <br /> c____ <br /> li/ - / ', .._ TYPICAL INTERIOR PARTITION � � 2X6 STUDS AT BEARING PER STRUCTURAL ENGINEER. USE 2X4 STUDS IN LIEU OF 2X6 STUDS <br /> �/ 7---- <br /> - - `0 BC PER UL DESIGN U349 <br /> , FIRE TEST ITS J20 06170.1,4 00 FOR 2x4 `` PTD FIBER CEMENT BOARD LAPPED SIDING, JOINTS <br /> 0 FIRE TEST ITS J99-22441.1, 10-99 FOR 2x6 jill*Ii <br /> PROJECT MANAGER <br /> • *.� SEALED& PROTECTED PER MANUFACTURER. EXTENT JS <br /> ii° 2x4 STUDS AT 16"ON CENTER PER ELEVATIONS PROJECT ARCHITECT <br /> c„--)) <br /> �►�' EXT. WALL AT HORIZ. CEMENT BOARD SIDING-2 HOUR Js <br /> �: 3 1/2" MINERAL FIBER INSULATION BB y- w PROJECT TEAM MEMBERS <br /> ►�.� <br /> IBC TABLE 721.1(3),30-1.1 1A <br /> SEE EXTERIOR ELEVATIONS FOR SIDING TYPE TS <br /> �� 2 AND FINISH. CHECK <br /> 0 j FIRESTOP PENETRATIONS PER CS1.05 ►'j 5/8" U.L. LISTED TYPE'X' GYPSUM WALLBOARD EXT INT <br /> .�� UL DES: U356 <br /> RESILIENT FURRING CHANNEL A <br /> in Si. • PTD FIBER CEMENT BOARD PANEL SIDING, JOINTS <br /> (2) LAYERS 5/8"TYPE'X'GYPSUM WALLBOARD ► SEALED & PROTECTED PER MANUFACTURER. EXTENT INTERTEK LABS BTC/WA 60-01 (LPB/WA-60-01) <br /> ► PER ELEVATIONS FOR B4- 1 HOUR RATING FROM BOTH SIDES ARCHITECT SEAL <br /> W ROOF-CEILING AT MEMBRANE ROOF, 1-HR CLASS B ROOF PER TABLE 1505.1 ELECTRSUITABLICAL E FORND UTILITY ACOUSTICANDES FIRE FIRE SEALING TED AND E2 OMIT INSULATION <br /> ENGINEERED WOOD JOIST 5/8" U.L. LISTED FIRE RATED TYPE'X'OR'C'GYPSUM <br /> -- ��-./ USE 1/2" LP FLAMEBLOCK FIRE RATED <br /> STAGGER LOCATIONS TO AVOID SAME STUD BAY j �_ �� WALLBOARD 7534 <br /> SHEATHING WITH TREATMENT FACING REGISTERED <br /> �'"1 AND SEE PARTITION NOTE#3 ABOVE E 1 �� <br /> ,,,��.��� USE 2X6 STUDS IN LIEU OF 2X4 STUDS ' 3/4" MODIFIED RAIN SCREEN STRAPPING OVER 1 LAYER EXTERIOR IN LIEU OF 1/2" PLYWOOD SHEER _ _ ARCHITECT <br /> a�� I WRB B4 SHEATHING&5 1/2"2.5 pcf MINERAL WOOL <br /> INSULATION IN LIEU OF R-21 INSULATION FOR 1 <br /> FLOOR ASSEMBLIES i EXTERIOR SHEATHING, 1/2" PLYWD SHEER SHEATHING, <br /> HR RATING BOTH SIDES <br /> �► , FIRE RATED, FASTEN PER STRUCTURAL ENGINEER, JOHN A. SHOESMITH <br /> INTERIOR PARTITION WALL STC 34 - 39 ►- TAPE AND SEALED AT EXTERIOR FACE. ELIMINATE INSULATION AND USE FIBER CEMEN- STATE OF WASHINGTON <br /> SIDING OVER 3/4" MODIFIED RAIN SCREEN <br /> PROVIDE R-10 THERMAL BREAK AT EDGES, PT WOOD BLOCKING E 01 tiks B3 STRAPPING <br /> FLAMEBLOCK FIRE R1 RATED SHEATHING WRB OVER 11//22" LP \�� <br /> WHERE FLOOR FINISH IS NOT RIGID-WOOD OR TILE. TYPICAL 1-HR WALL CONST.SEPARATING <br /> 0 TREATMENT FACING EXTERIOR IN LIEU OF 1/2" <br /> FINISH FLOOR OVER REQUIRED UNDERLAYMENT `' ' UNITS AND CORRIDORS AT BEARING ! MIN R-21 HIGH DENSITY FIRE RATED BATT OR BLOWN IN U.L. LISTED FIRE RATED TYPE'X'OR'C'GYPSU <br /> PER SPECS AND FLOOR SCHEDULE if ; INSULATIONCITY O EVERETT <br /> CORRIDOR GRID LINE @FINISHED FACE OF WALL UL DES. U344 i ����� WALL OARD <br /> V � __ 2X6 STUDS AT BEARING PER STRUCTURAL ENGINEER. REVIEWED FOR PERMIT <br /> FINISH AND SEAL FLOOR PER SPECS AND FINISH SCHEDULE �� B2 USE 2X8 STUDS IN LIEU OF 2X6 STUDS <br /> WHEN USED AS SMOKE BARRIER, EXTEND -� <br /> CONCRETE SLAB ON GRADE PER STRUCTURAL ENGINEER _ ` limih__F-- PTDFIBERCEMENTBOARD LAPPEDSIDING, JOINTS <br /> 1 LAYER 5/8" U.L. LISTED FIRE RATED TYPE'X'OR'C' WALL TO BOTTOM OF ROOF SHEATHING AS OSEALED & PROTECTED PER MANUFACTURER. EXTENT USE 2X4 STUDS IN LIEU OF 2X6 STUDS <br /> GYPSUM WALLBOARD EA SIDE, STAGGER JOINTS& REQUIRED TO COMPLY WITH IBC 709 1 ►_'- PER ELEVATIONS FILL CAVITY COMPLETELY WITH MIN R-21 TITLE <br /> 10 MIL POLY VB BELOW SLAB OVERLAP 6"AT SEAMS AND RUN UP PROVIDE ACOUSTIC SEALANT AT TOP AND BASE B 1 AIR IMPERMEABLE CLOSED-CELL SPRAY ASSEMBLIES • <br /> WALL PAST TOP OF SLAB-SEAL AT PERIMETER FELT ► .� V <br /> 2x6 STUDS IN BEARING WALL PER STRUCTURAL FIRESTOP PER CS1.05 EXT. WALL AT HORIZ. CEMENT BOARD SIDING-1 HOUR INSULATION IN LIEU OF BATT INSULATION <br /> R-10 MINIMUM RIGID INSULATION - EXTEND 24"MINIMUM UNDER SLAB ENGINEER DETAILS AND PLANS B WALL TYPES <br /> AT ALL CONDITIONED SPACES PER WSEC C402.2.6 AND TABLE C402.1.3 J <br /> "�A"" -� I RESILIENT CHANNEL ACOUSTIC CONNECTION SYSTEM A EXT INT FLOOR-CEILING <br /> p� p ONE SIDE OF WALL <br /> PROJECT NO. <br /> ° p p° p 3" MINERAL WOOL FIRE RATED ACOUSTIC BATTS D3 USE 2X10 STUDS IN LIEU OF 2X6 STUDS n a , CONCRETE STEM WALL PER STRUCTURAL ENGINEER 18.03-01 <br /> ° p A°A ° 4 A ° p �. � <br /> i I i ° � • -.leC FINISH PER SCHEDULE APPROVED LIQUID APPLIED WATERPROOFING AT WALL DATE <br /> USE 2X8 STUDS IN LIEU OF 2X6 STUDS ° FACE WITH ATTACHED DRAINAGE MAT WITH HEM 12/21/2018 <br /> ,° 1/2" PLYWOOD FOR SHEER PER STRUCTURAL UNDER D2 p° ° ATTACHMENT AT TOP PROJECT NETWORK PATH <br /> �v ° ° GWB <br /> ° ° , <br /> ° ° °�� n1` � �' ELECTRICAL AND UTILITY BOXES FIRE RATED AND SUITABLE FOR ACOUSTIC AND FIRE SEALING. p 1 USE 2X4 STUDS IN LIEU OF 2X6 STUDS AA <br /> ° PROVIDE (APPROVED CLASS I VAPOR RETARDER PER IRC <br /> STAGGER LOCATIONS TO AVOID SAME STUD BAY p R408.2) 10 MIL POLY VB/CAPILLARY BREAK ABOVE REQUIRED <br /> RIGID INSULATION CONTINUOUS UP AND UNDER SILL TO <br /> MIN 4" FREE DRAINING GRANULAR FILL AND SEE PARTITION NOTE#3 ABOVE _'_.: SHEET NUMBER <br /> EXTERIOR FACE OF WALL <br /> SEE PLANS FOR AREAS REQUIRING BLOCK OUTS FOR RECESSES; IE: ROLL-IN SHOWER <br /> SLAB ON GRADE D INTERIOR 1-HOUR WALL - STC 50 - 54 A EXTERIOR STEM WALL - BELOW GRADE <br /> LCOPYRIGHT©2019 shoesmith cox architects <br />