Laserfiche WebLink
ABBREVIATIONS GENERAL NOTES: SHEET DRAWING INDEX: FF E PLAN GENERAL NOTES --, \ <br /> A. FURNITURE LAYOUTS, SUBJECT TO FINAL APPROVAL BY OWNER <br /> A: Area,Ampere;Acre;Alcove;Compressed Air Line L: Angle,Left,Length,Lighting Panel,Long,Line O THE FOLLOWING DRAWINGS ARE NOT FOR CONSTRUCTION,ALL DRAWINGS ARE SUBJECT TO OWNER'S FINAL APPROVAL. ID-0.0 COVER SHEET ---- <br /> ABV: Above LAM: Laminate,Laminated ID-1.0 NORTH SOUTH ADDITIONS-FF E LAYOUT B. DRAWING NOT FOR CONSTRUCTION BPI TA j DESIGN <br /> AC: Air Conditioning,Alternating Current,Acoustical LAT: Lateral O CONTRACTORS SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS PRIOR TO STARTING WORK AND SHALL NOTIFY ID-2.0 NORTH ADDITION-ACCENT PAINT LOCATIONS ®t"S 1 l. <br /> ACC: Access Lavatory OWNER/ARCHITECT AND/OR DESIGNER OF ANY DISCREPANCIES. ID-2.1 SOUTH ADDITION-ACCENT PAINT LOCATIONS <br /> ACFL: Access Floor LBL: Label ID-3.0 NORTH ADDITION-FLOOR FINISH DIAGRAM FF E PLAN — KEYNOTES 14030 NE 24th ST Suite 201 <br /> ACR: Acrylic LCL: Linen Closet O ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF ALL APPLICABLE BUILDING CODES AND AGENCIES HAVING ID-3.1 SOUTH ADDITION-FLOOR FINISH DIAGRAM Bellevue.WA 98007 <br /> 425-643-8363 <br /> ACST: Acoustic <br /> LIB: Library JURISDICTION OVER THE VARIOUS PHASES OF THE WORK. ID-4.0 NORTH SOUTH ADDITIONS-ELECTRICAUDATA LAYOUT CD TBD vvw v.bristaislesi n.com <br /> ACT: Actual 9 <br /> LIN: Linear ID-5.0 FINISH LEGEND/SCHEDULES <br /> ADDL: Additional LN: Length O REFER TO CIVIL ENGINEER'S DRAWINGS FOR FINISH PAD ELEVATION,FINISH GRADES,SIDEWALKS,UTILITIES,AND DRAINAGE. <br /> ADH: Adhesive <br /> ADJ: Ad ust,Ad ustable,Ad acent LNLOCS:DG: Locations <br /> z TBD <br /> ions O REFER TO STRUCTURAL ENGINEER'S DRAWINGS FOR ALL STRUCTURAL RELATED INFORMATION INCLUDING,BUT NOT LIMITED <br /> AFF: Above Finished Floor LR: Living Room TO SLAB,FOUNDATION,FRAMING,SHEAR WALL,MASONRY,ETC... CD TBD <br /> ALT: Alternate,Alteration;Altitude LT: Light,Low Tension Duct,Laundry Tray <br /> AMB: Ambient LTG: Lighting 6e. REFER TO MECHANICAL ENGINEER'S DRAWINGS FOR ALL MECHANICAL RELATED INFORMATION INCLUDING BUT NOT LIMITED <br /> AP: Access Panel LVR: Louver TO HEATING,AIR CONDITIONING,DUCTING,VENTILATION,REGISTER SIZES,ENERGY CALCULATIONS, ETC... FF E PLAN — SYMBOL LEGEND <br /> APPROX: Approximate LW: Light Weight <br /> APRVD: Approved LWDP: Louvered Wood Door, Painted O REFER TO PLUMBING ENGINEER'S DRAWINGS FOR ALL PLUMBING RELATED INFORMATION INCLUDING BUT NOT LIMITED TO <br /> APT: Apartment ROOF DRAINS AND OVERFLOWS,PLUMBING FIXTURES,DRAINS,CONDENSATES,WATER HEATER,AND HOSE BIBS. FLOOR OUTLET BOX WITH DUPLEX RECEPTACLE <br /> ARCH: Architect,Architectural MARB: Marble <br /> ASC: Above Suspended Ceiling MAS: Masonry 0 REFER TO ELECTRICAL ENGINEER'S DRAWINGS FOR ALL ELECTRICAL RELATED INFORMATION INCLUDING BUT NOT LIMITED TO raw <br /> ASSEM: Assemble MAIL: Material POWER/SERVICE PANEL REQUIREMENTS,WIRING,CONDUITS,OUTLETS,LIGHTING,SWITCHES, ETC... Nt• FLOOR OUTLET BOX WITH QUAD RECEPTACLE <br /> ATC: Acoustical Tile Ceiling MAX: Maximum <br /> AUTH: Authori ed MB: Mail Box,Machine Bolt,Mop Basin e BLOCKING MAY BE REQUIRED AT CERTAIN LOCATIONS.CONTRACTOR TO CONFIRM WITH DESIGNER OWNER. i' QUAD RECEPTACLE <br /> MECH: Mechanical <br /> B: Boiler,Bathroom,Bidet MED: Medium 10. ALL FLOOR FINISH TRANSITIONS TO BE PROVIDED WITH METAL TRANSITION STRIPS. Q.B TO B: Bac to Bac MED CAB: Medicine CabinetID CO <br /> DUPLEX RECEPTACLE <br /> B/: Bottom(of) MET: Metal 11. WALK OFF MAT(WOM)TO BE INSTALLED AT ALL ENTRY DOOR LOCATIONS(TO BE VERIFIED BY OWNER). <br /> BBD: Bulletin Board MEZZ: Me anine Q TELEPHONE DATA RECEPTACLE 0 <br /> Stelletaiti BDL: Bundle MFR: Manufacture,Manufacturer eINSTALL ALL WALL FLOOR COVERINGS PER MANUFACTURERS INSTRUCTIONS. a <br /> BDY: Boundary MIN: Minimum IF- INTERIOR FURNISHING. IF#CORRESPONDS TO FF E <br /> BDRM: Bedroom MIR: Mirror e PROVIDE MANUFACTURERS APPROVED FLOOR FINISH UNDERLAYMENT AS REQUIRED. BUDGET PROVIDED BY BRISTAL DESIGN INISSEIVIIII C) <br /> BEL: Below MISC: Miscellaneous <br /> BET: Between MLD: Molding (f41 ALL ACCENT WALL PAINT FINISHES TO BE 3 SHEEN LEVELS LOWER THAN TRIM,NOTED SHEENS ARE BASED ON SHERWIN <br /> BEV: Bevel MO: Masonry Opening v WILLIAMS FINISHES,THEY ARE NOT REPRESENTATIVE OF OTHER MANUFACTURERS FINISHES. <br /> BF: Board Foot,Bac Face,Bottom Face MOD: Module <br /> II <br /> BG: Bag(e.g.,of cement) MONO: Monolithic ( ALL PAINT COLOR SELECTIONS TO BE CONFIRMED PENDING APPROVAL OF ALL OTHER INTERIOR FINISHES. DECORATIVE LIGHTING — SYMBOL LEGEND <br /> BLDG: Building MTD: Mounted <br /> BLKG: Bloc ing MTL: Material,Metal 0 ALL NON-ENTRY DOORS TO BE PAINTED TO MATCH ADJACENT WALL COLORS <br /> BLT-IN: Built-In MWK: Millwor <br /> BN: Bullnose eACTUAL DIMENSIONS MUST BE FIELD VERIFIED AND ADJUSTED AS NEEDED.ALL ADJUSTMENTS MUST BE APPROVED BY O 18"LED DRUM PENDANT/3500K/DIMMABLE <br /> BR: Bedroom, Bric ,Brass,Boiler Room Branch N: North,Nitrogen OWNER. c1J <br /> BRK: Bric NAT: Natural O 6" LED MINI PENDANT/3000K/DIMMABLE <br /> BSMT: Basement NIC: Not In Contract 0THE BUILDERS WRITTEN CONTRACT SPECIFICATIONS HAVE PRECEDENCE OVER ALL INFORMATION SHOWN IN THIS DRAWING '' i�i <br /> BT: Bathtub, Bolt NO: Number,Normally Open SET. CD FOOD WARMER PENDANT 6�l�J <br /> NTS: Not To Scale <br /> C/C: Center to Center 19. WRITTEN DIMENSIONS IN THE DRAWING SET HAVE PRECEDENCE OVER SCALED DIMENSIONS.DO NOT SCALE DRAWINGS. ®CO LED WALL WASHER <br /> LI <br /> CAB: Cabinet OC: On Center <br /> CO <br /> CAP: Capacity OFF: Office 20 VIF=BUILDER TO"VERIFY IN THE FIELD"AND ADJUST DIMENSIONS,MATERIALS OR CONSTRUCTION TECHNIQUES TO INSURE o+ <br /> CAR: Carpet OHD: Overhead Door THE INTEGRITY OF THE DESIGNERS INTENT. CD LED WALL SCONCE/3000K <br /> CCT: Circuit OPNG: Opening <br /> CEM: Cement �' 4-0 <br /> OPP: Opposite 21 CLWO="CONFIRM LOCATION WITH OWNER"PRIOR TO ROUGH-IN OR INSTALLATION CD RECESSED CAN LIGHTING THROUGHOUT <br /> CER: Ceramic OUT: Outlet <br /> CF: Cubic Feet 22 BUILDER MUST UNDERSTAND"VIF" ASK THE DESIGNER FOR ANY AND ALL CLARIFICATION NEEDED PRIOR TO PERFORMAING CD AMBIENT LIGHTING THROUGHOUT <br /> CG: Corner Guard P: Pitch,Power Panel, Paint ANY WORK. 'U CH: Coat Hoo PAR: Parallel <br /> CHB: Chal Board O DIRECT/INDIRECT WALL WASHERS <br /> PARTN: Partition <br /> CIR: Circle,Circular,Circuit PBD: Particle Board <br /> CIRC: Circumference PDP: Paneled Door,Painted ecp SEMI-FLUSH MOUNT 18"DRUM PENDANT/3500K DIMMABLE 5 <br /> CK: Caul ing PERIM: Perimeter <br /> CKT: Circuit PERP: Perpendicular <br /> CL: . Centerline,Clearance,Closing,Closure,Class,Closet PFN: Prefinished CO <br /> CLG: Ceiling PKWY: Par way ACCENT PAINT LEGEND <br /> CLO: Closet PL: Plate,Plan, Property Line,Plastic Laminate,Plastic <br /> LO <br /> CLR: Clear PLAS: Plaster,Plastic <br /> CLS: Closure PLAM: Plastic Laminate MFGR:TO MATCH; SHERWIN WILLIAMS <br /> CMT: Ceramic Mosaic Tile PLMBG: Plumbing `® '� IOW* P"2 /COLOR: HONED SOAPSTONE,#SW 9126 <br /> CMU: Concrete Masonry Unit PLYWD: Plywood FINISH: SATIN/EGGSHELL <br /> CND: Condition,Conduit PLUMB: Plumbing <br /> CNTR: Center,Counter PNL: Panel _ MFGR:TO MATCH; SHERWIN WILLIAMS <br /> C.O.: Cased Opening PNT: Paint SHELL <br /> COL: Column P3 PATTERN:THUNDEROUS,#SW 6201 FINISH: SATIN/EGGSHELL Polish,Polished <br /> CONC: Concrete PORC: Porcelain <br /> P 4/CONN: Connection PP: Plaster,Painted,Power Panel, Precast Panel MFGR: TO MATCH; BENJAMIN MOORE <br /> PATTERN: NOCTURNAL GRAY,#2135-30 <br /> COR: Corner,Corridor PREFAB: Prefabricated FINISH: SATIN/EGGSHELL <br /> CPT: Carpet PRTN: Partition O A <br /> CR: Curtain Rod PT: Paint,Point,Part,Potential Transformer MFGR:TO MATCH; DESIGNTEX <br /> CSMT: Casement PTD: Painted, Paper Towel Dispenser WC-3/ PATTERN:TWINKLE#6685-402 <br /> CTR: Center,Counter PTD/R: Combination Paper Towel Dispenser/Receptacle COLOR: SLATE <br /> PTR: Paper Towel Receptacle <br /> PWR: Power <br /> D: Deep,Depth, Drop,Drain <br /> DF: Drin ing Fountain QUAL: Quality ACCENT PAINT DIAGRAM — GENERAL NOTES <br /> DIFF: Diffuser QUANT: Quantity <br /> DIM: Dimension QT: Quarry Tile,Quart <br /> DISL: Disposal QTR: Quarter A. REFER TO ID-5.0 FOR INTERIOR FINISH LEGEND FINISH SCHEDULES FOR <br /> DISP: Dispenser QTY: Quantity <br /> DN: Down ADDITIONAL SPECIFICATION INFORMATION <br /> DR: Door, Drain, Dining Room R: Riser,Radius, Resistance,Relay Panel <br /> DTL: Detail RAD: Radius,Radiator <br /> DWG: Drawing RB: Rubber,Rubber Base,Resilient Base B. SUBMIT ALL FINISHES TO INTERIOR DESIGNER FOR REVIEW APPROVAL, REVISIONS. <br /> DWP: Drywall,Painted RBC: Rubber Base(Coved), PRIOR TO FABRICATION INSTALLATION. <br /> DWR: Drawer RBS: Rubber Base(Straight) <br /> DX: Direct Expansion,Duplex RCP: Reflected Ceiling Plan,Reinforced Concrete Pipe 3.13.2019 -FF E/FINSIH SCHEDULE <br /> RECP: Receptacle <br /> E TO E: End to End REF: Refer,Reference,Refrigerator C. WALL PAINT TO BE 3 SHEEN LEVELS LOWER THAN TRIM. NOTED SHEENS ARE <br /> EA: Each REFL: Reflected,Reflector BASED ON SPECIFIED MANUFACTURERS FINISHES.THEY ARE NOT REPRESENTATIVE <br /> EJ: Expansion Joint REM: Remove,Removable OF OTHER MANUFACTURERS FINISHES. <br /> ELEC: Electrical REQ: Re uire,Re uired <br /> ELEV: Elevator,Elevation RESIL: Resilient <br /> EMER: Emergency RET: Return,Retaining D. TRIM DOOR PAINT TO BE 3 SHEEN LEVELS HIGHER THAN TRIM. NOTED SHEENS <br /> ENAM: Enamel REV: Reverse,Revise,Revision ARE BASES ON SPECIFIED MANUFACTURERS FINISHES.THEY ARE NOT REPRESENTATIVE <br /> ENCL: Enclosure RGH OPNG: Rough Opening <br /> ENGR: Engineer RM: Room OF OTHER MANUFACTURERS FINISHES. <br /> ENTR: Entrance RMV: Remove <br /> EQ: E ual RPT: Repeat(li e"Ditto") <br /> EQUIP: E uipment RR: Railroad E. ACCENT PAINT COLORS TO END AT INSIDE WALL CORNERS. <br /> EST: Estimate RT: Rubber Tile,Right <br /> EXCAV: Excavate <br /> EXH: Exhaust S: South,Sealant,Supply,Sin <br /> EXH AIR: Exhaust Air S S: Stained Sealed F. CONTRACTOR TO VERIFY WALL CONDITIONS <br /> EXIST: Existing S V: Stain Varnish <br /> EXP: Expansion,Exposed SALT: Suspended Acoustical Tile FLOOR FINISH DIAGRAM <br /> EXT: Exterior,Extinguish SCHED: Schedule <br /> EXTR: Extrude SCWD: Solid Core Wood <br /> F: Degrees Fahrenheit,Fuse SD: Soap Dispenser • CPT-1 <br /> F TO F: Face to Face MFGR SHAW CONTRACT <br /> SECT: Section ', <br /> FA: Fire Alarm,Fresh Air SEL: Select • ,^ COLOR r'LAND APEiT7 LE 5T114 <br /> FABR: Fabricate SF: S uare Foot <br /> FBF•: Fabric Panel SH: Shelf,Sheet,Shower �M CPT-2 <br /> FC: File Cabinet,Foot Candle,Fault Current MFGR SHAW CONTRACT <br /> SHR: Shower an PA ERN STrgATILE 5T116 <br /> FDN: Foundation SIM: Similar COLOR aNOscAPE <br /> FE: Fire Extinguisher SK: Sin <br /> FF E: Fixtures,Furnishings E uipment =CELL= MFGR n1WKEr, GENERAL <br /> g p SKL: S ylight _LLLLL <br /> g SND: Sanitary Nap in Dispenser _LLLLL PATTERN NATURAL WOOD GRAINS,LEVEL SET COLLECTION <br /> FGL: Fiberglass _LLLLL COLOR HERITAGE WOOD,HERM COURAGE <br /> FHY: Fire Hydrant SPEC: Specification,Specifications , LVT-2 <br /> FIN: Finish,finished SPECS: Specifications At '® MFGR PARTERRE <br /> FIXT: Fixture SPLR: Sprin ler A, • PATTERN INGRAINED RESILIENT PLATIK <br /> p k `O COLOR HEART PINE 411828 <br /> FLG: Flooring SQ: S uare <br /> FLUOR: Fluorescent SST: Stainless Steel <br /> FPL: Fireplace STD: Standard KVAI I sv-, <br /> FRM: Frame ' Al MFGR NJ ANNE <br /> STOR: Storage OA COLORrIPRO3 ACCZENT <br /> FLOURISH <br /> FT: Foot,Feet,Fully Tempered STRUC: Structural <br /> FUR: Furred STWY: Stairway 1 . T-1 <br /> FURN: Furnish, Furniture SV: SafetyRelief Valve I MFGR THOMPSON TILE <br /> PATTERN CHAMBRAY OV CH OLV 1224 <br /> SY: S uare Yard COLOR TBD <br /> G: Gas,Girder,Gutter,Gram <br /> GENL: General <br /> vvv< 7-5 <br /> GL: Glass T/: Top v v v• PATTERN TBD <br /> O v O V MFGR THOMPSON TILE <br /> GLZ: Gla e TB: Towel Bar o v_o v COLOR TBD <br /> GRND: Ground TEMP: Temporary,Tempered,Temperature <br /> GT: Grout TEN: Tenant ��� WOA FGR MWKEN <br /> GV: Galvani ed THRMST: Thermostat // PATTERN OBE<ENTRY SYSTEMS,OUADRUS GRAVITY <br /> GVL: Gravel THRU: Through // COLOR GRA27-23,CONVERGE <br /> GYP: Gypsum TKBD: Tac board <br /> GYP BD: Gypsum Board TLT: Toilet <br /> TPD: Toilet paper Dispenser FLOOR FINISH PLAN — GENERAL NOTES <br /> H: High TPH: Toilet Paper Holder <br /> HD: Head,Heavy Duty TPTN: Toilet Partition A. REFER TO ID-5.0 INTERIOR FINISH LEGEND FINISH SCHEDULES FOR ADDITIONAL <br /> HDCP: Handicapped(better called"Accessible") TSTAT: Thermostat <br /> HDR: Header TT: Terra o Tile,Traffic Topping SPECIFICATION INFORMATION <br /> HDW: Hardware TV: Television <br /> HDWD: Hardwood TW: Top of Wall,Thin Wall(conduit),Tempered Water <br /> HGT: Height TYP: Typical B. SUBMIT ALL FINISHES TO INTERIOR DESIGNER FOR REVIEW APPROVAL, PRIOR TO <br /> HK: Hoo or Hoo s FABRICATION INSTALLATION DATE: <br /> HORIZ: Hod ontal TZ: Terra o March 13, 2019 <br /> HOSP: Hospital UH: Unit Heater <br /> HR: Hour UNF: Unfinished DRAWN BY: MAC <br /> HT: Height,Heat,High Tension Duct UON: Unless Otherwise Noted C. INSTALL ALL FLOOR COVERINGS PER MANUFACTURERS INSTRUCTIONS <br /> HTR: Heater UR: Urinal CHECKED BY: CH <br /> HWD: Hardwood UT: Utility <br /> D. PROVIDE MANUFACTURERS APPROVED FLOOR FINISH AND ACOUSTICAL <br /> IN: Inch VBC: Vinyl Base(Coved) UNDERLAYMENT AS REQUIRED <br /> INCAND: Incandescent VBS: Vinyl Base(Straight) <br /> IINSP: Inspect VCT: Vinyl Composition Tile <br /> INS L: Install VEST: Vestibule <br /> INSUL: Insulation VIN: Vinyl E. PROVIDE TRANSITION STRIPS WHERE REQUIRED. <br /> VNR: Veneer <br /> J-BOX: Junction Box VT: Vinyl Tile M <br /> JC: Janitor's Closet VWC: Vinyl Wall Covering F. WALK-OFF MAT TO BE INSTALLED AT ALL EXISTING ENTRY DOORS. LOCATIONS TO <br /> JCT: Junction <br /> BE VERIFIED BY OWNER. <br /> JF: Joint Filler <br /> W: West,Width,Wide,Watt,Waste,Water,Water Main <br /> JST: Joist WB: Wood Base <br /> JT: Joint <br /> ID COVER SHEET <br />