GENERAL NOTES <br /> FOR WINDOWS WTH OPERABLE OPENINGS MORE THAN 72' = m L. <br /> ABOVE THE FINISHED GRADE OR SURFACE BELOW, THE <br /> LOWEST PART OF THE CLEAR OPENING SHALL BE 24' U d s n o <br /> MINIMUM ABOVE THE FLOOR. EXCEPTIONS: FULLY OPEN 0 `'�"' <br /> In <br /> WINDOWS WHERE A 4" SPHERE MAY NOT PASS THROUGH <br /> EXIST. FLOOR JOISTS OR WHERE FALL PREVENTION DEVICES ARE PROVIDED PER CD z ff Lo to <br /> r , ASIMF2090ORR312.2.2. re <br /> ai d <br /> —� PROVIDE SAFETY GLASS PER IRC R308. _. a <br /> = --NEW 5Cx13X ( ULAM c° "'r8 <br /> BEAM (SEE PLAN FOR SKYLIGHTS TO BE DOUBLE PANEL, SHATTER RESISTANT �3 0 <br /> OTHER BEAM SIZES) If r -I NOTE: VERIFY THE U-VALUE FOR APPROVED RIGID PLASTIC, LAMINATED SAFETY GLASS, w ry o <br /> EX G DECK MI/ ALL FENESTRATION NOTE VERIFY SMOKE ALARMS PER SECTION FULLY TEMPERED GLASS, HEAT-STRENGTHENED GLASS, ® �, v CV <br /> R314, AND CARBON MONOXIDE ALARMS PER OR WIRED GLASS. PROVIDE 4" MINIMUM CURB (OR SELF = �' <br /> FLASHING ASSEMBLY WITH 3:12 MINIMUM PITCH OR PER w W 6m a <br /> ® , - - - SECTION R315, ARE PRESENT THROUGHOUT THE r ' o <br /> VERIFY HORS OVER En DOOR MANUFACTURER INSTRUCTIONS). <br /> F- ENTIRE STRUCTURE `o_ <br /> et WINDOWS TO BE EQUAL TO HOSE BIBBS TO BE BACKFLOW PREVENTION AND FREEZE "'� <br /> w OR GREAItR THAN HDR ,� <br /> CALLED OUT RESISTANT TYPE. <br /> ce <br /> ca = <br /> 1- ALL HOLDOWNS. FRAMING ANCHORS & SHEARWALL <br /> ® 11'-6" 2'-4' 1O'-4" 2'-4" 13'.6" NAILING MUST BE INSPECTED BEFORE COVERING. <br /> i- w m I / / / DO <br /> 20 ji <br /> ¢= En - <br /> W EX'G CANT. ABV Ex'G DOOR VERIFY EGRESS WINDOWS PER R310 0 <br /> 1 EX'G EX'G EX'G EX'G —1 7Y MAX STEP TO EX'G Lj,J EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE A <br /> -0, -co I WINDOW WINDOW WINDOW WINDOW 3x3 MIN LANDING WNDOW HEIGHT OF NOT MORE THAN 44 INCHES MEASURED FROM o V <br /> (2)2x6 j2HF 4x10 2DF 6x10 - (2)2x6 CIF 4x8 f2DF 4x8 j2DF THE FINISHED FLOOR TO THE BOTTOM OF THE CLEAR <br /> �mi E� ter• — OPENING. EMERGENCY ESCAPE AND RESCUE OPENINGS t <br /> r .._ SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5.7 vl.� <br /> ;WIFE; — -i �%' r , SQUARE FEET(5.0 S.F. AT GRADE FLOOR) THE MINIMUM <br /> REINFORCED CONCRETE — < Ct. <br /> o NET CLEAR ING HEIGHT SHALL BE 24 INCHES, THE <br /> 0 ; <br /> 0MINIMUM NET CLEAR OPENING WIDTH SHALL BE 20 INCHES <br /> SLAB , -� I 3 o 4 AND EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE <br /> NEW GRAVEL BASE D OPERATIONAL FROM THE INSIDE OF THE ROOM WITHOUT THE <br /> COMPACTED TO 95% "') 2� e USE KEYS, TOOLS OR SPECIAL KNOWLEDGE <br /> ao \ LT <br /> u :sue' a CI i ' N i„i,,,,.ii,,ii w= t/j v% ^f�� �, N CO <br /> a <br /> 7�� r BEDRM KITCHEN TCH E _ <br /> ��\���\EXIST. DIRT GRADE ;\\\��\ BATHROOM NOTES <br /> �' DL REMOVE EX'G BEAM "�o r�' 0FIREBLOCK TUBS AND SHOWERS PER R302.11. " ul <br /> I OVE EX'G B • a. REMOVE EX'G BEAM s ce & COLUMNS 'x30" MINIMUM CLEAR SPACE IN SHOWER. 22' MINIMUM r N <br /> co I DTH SHOVER DOOR TO OPEN OUTWARD IF HINGED. 30 <br /> AI �UILD�NG SECTION SCALE: h•_ ,�-o' 4x6 & COLUMNS a 4xs & COLUMNS <br /> �, tr) 1 a " " o 6x6 WOE X 24' DEEP CLEAR SPACE REQUIRED OUTSIDE SHOWER CO <br /> 111, COL _ C�- J 5K x 13J5 24F-V4 ( 8__ �N %% OL DOOR. ENCLOSURES TO BE SAFETY GLASS. NONABSORBENT Q vwi <br /> w o- -5Ya'x 0}�° 24F-V4 GLB I' 5}�'xx 9�24F-V4 CLB 4x6 7'-3" MIN. HEAD CIR. I \_ SURFACE UP 6' WITH SHOWER. USE CEMENT BOARD OR Lu <br /> > <br /> o w a. a COL I I UNDER BM CEMENT FIBER BOARD FOR TILE BACKING. VAPOR BARRIER \� tx J <br /> B E�R M. 1% '� 003 N SD ( I N SHOWER FLOW NOT PERMITTED BEHIND <br /> TUB OR SHOWER CONTROL�M 1 <br /> R - ,°,; VALVES TO BE PRESSURE BALANCE OR THERMOSTATIC <br /> I I LECTRIC FIREPLACE W1 �.. <br /> O 2s z o MIXING TYPE. 1.6 GAL PER FLUSH MAXIMUM TOILETS. 15 <br /> I % SD T.V. ALCOVE ABV ``' <br /> o ® CLEAR SPACE REQUIRED. EACH SIDE FROM t OF TOILET & <br /> %,,,,;, �k' N 4 21' CLEAR SPACE REQUIRED IN FRONT. INSTALL 2x10 C <br /> 26 LIVING R M. n' --w °O 0 BELOW SILL HEIGHT IF TNG FOR TOWEL OWN OW INSTALL OVE FLOOR OR <br /> FOR <br /> FINISHED CEILING HT " <br /> 5' 10" 5'-0" o SD T.P. HOLDERS. INSULATE EXTERIOR WALLS ADJACENT TO <br /> y OF BASEMENT TO SHOWERS AND TUBS AND INSTALL AIR BARRIER SEPARATING <br /> 1 <br /> 1 -o- BE 8'-4Y2° THEM FROM THE SHOWERS AND TUBS. <br /> i ILT-INS LINEN %/•, ,,/?,/? ,/?;,/,,,• :>/s.. „,%, ; ,) ,/s,/;,./7:�s n,,,,,s,/;, ,/s,%;,, vfi o <br /> 4°BF $ CRAWL ACCESS R408.4 < <br /> %I ( 2 ' d I I `e/' 18'x24" MINIMUM THRU FLOOR ACCESS w/"TIGHT FIT CZ <br /> O BATH VERIFY WALL LOC. TO ALIGN >- WEATHERSTRIPPED INSULATED DOOR OR 16 HEIGHT x w <br /> a I II c ( WITH EX G COLUMNS ® 24' MINIMUM THROUGH WALL CRAWL ACCESS W/ DOOR. F. <br /> sI N I I I ®• ��•,,J 45Vii , IF ANY PART IS BELOW GRADE, PROVIDE A 16'x24' co>, <br /> X /"`\ 6-0 VANITY ' MINIMUM AREAWAY TO EXTEND BELOW THE OPENING <br /> I Lu <br /> II "" I J -: THRESHOLD. THROUGH WALL ACCESS OPENINGS SHALI <br /> fig/ 0 NOT 8E LOCATED UNDER A DOOR TO THE RESIDENCE. <br /> a ss,;;;;;;,: ) ,, <br /> ,;;% % X <br /> NON-BR'G WALL TO SEPARATE NEW 3 <br /> ,,, LIVING FROM En CRAWL SPACE TO C z�,a ELECTRICAL LEGEND <br /> 0; REMAIN STACKED WASH SMOKE DETECTOR PER R313 & LISTED PER UL 217. INSTALL <br /> w & DRY V.T.O.S. w <br /> /� �r ®�/ SD PER HOUSEHOLD WARNING PROVISIONS OF NFPA 72 & PER _) <br /> o z O'' E X'G GARAGE ABV V BACKUP. INTERCONNECS. 110V CT EACH BEDROOM AND LEVECURRENT WITH TTERY o tt <br /> IS <br /> ET.. ET _. <br /> En BEAM & <br /> COLUMNS 45 kilt COMBINATION SPOT & WHOLE-HOUSE EXHAUST. SEE z <br /> WH VENTILATION NOTES ON SEPARATE SHEET. <br /> n <br /> o TANK ` 50 0 50 CFM (MIN.) EXHAUST FAN - VENT TO EXTERIOR. Lu a <br /> CD CRAWL SPACE w z W <br /> Et U3 <br /> a MECHANICAL AREA a <br /> ENERGY CREDITS PER R406.2 0 CC Q E <br /> re <br /> 5a EFFICIENT WATER HEATING 5a: CREDITS: 0.5 `� _;> <br /> ALL SH0? RHEAD AND KITCHEN SINK FAUCETS <br /> INSTALLED IN THE HOUSE SHALL BE RATED AT 1.75 LLJ ..I.: <br /> g w <br /> X GPM CR LESS. ALL OTHER LAVATORY FAUCETS SHALL <br /> w <br /> BE RATED AT 1.0 GPM OR LESS.' oo z <br /> LAZTO Y THIS T, THE BUILDING PERMIT DRAWINGS I N vi <br /> SHALL SPECIFY THE OPTION BONG SELECTED AND CL U w <br /> SHALL SPECIFY THE MAXIMUM FLOW RATES FOR ALL Or) 1E I- <br /> al <br /> SHOYERHEADS, KITCHEN SINK FAUCETS, AND OTHER O =z <br /> LAVATORY FAUCETS. cD <br /> -.....1 Ei us <br /> rw <br /> 5b EFFICIENT WATER HEATING 5b: CREDITS: 1.0 ®- <br /> WATER HEATING SYSTEM SHALL INCLUDE ONE OF THE v <br /> FOLLOWNG <br /> GAS WATER HEATER WTH A MINIMUM �' <br /> FLOOR PLAN SCALE Y," = 1'-U° O QUAOL.IFY TO CLAM THIS CREDIT, THE BUILDING C) <br /> '../2 /5 :1 <br /> PERMIT DRAWINGS SHALL SPECIFY THE OPTION BEING <br /> 800 SQ. FT. LIVING SELECTED AND SHALL SPECIFY THE WATER HEATER <br /> EQUIPMENT TYPE AND THE MINIMUM EQUIPMENT <br /> SQUARE FOOTAGE TAKEN AT THE EFFICIENCY. <br /> OUTSIDE PERIMETER OF NEW FULL <br /> HEIGHT FURRING WALLS, (INSIDE OF TOTAL CREDITS: 1.5 <br /> FULL HEIGHT CONCRETE FOUNDATION O� <br /> WALLS) , <br />