My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2322 CEDAR ST 2018 Plans 2022-10-28
>
Address Records
>
CEDAR ST
>
2322
>
Plans
>
2322 CEDAR ST 2018 Plans 2022-10-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/28/2022 1:47:38 PM
Creation date
7/22/2021 11:39:34 AM
Metadata
Fields
Template:
Address Document
Street Name
CEDAR ST
Street Number
2322
Permit
CW1809-002
Year
2018
Notes
Add Laundry / Bath / Kitchenette
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 I <br /> 2 I 3 I 4 I 5 <br /> IIFH <br /> I -AS <br /> Prescriptive Energy Cods Compliance for All Climate Zones In Washington Table R402.1,1 FootnotesProi <br /> irrrcNmetla, Contact information For SI: 1 foot,=304.8 mm,ci =continuous Insulation, int intermediate framing. .25.224.6=" ' , eve ad wa E <br /> I mB.deslgn.eeMce9�gmall.com <br /> D 2322 Cedar Ave ' R-values are minimums. U-factors and SHGC are maximums.When insulation is installed in a cavity which is design 1 dredeng I °maddi g <br /> Everett, Wa 98201 less than the label or design thickness of the Insulation,the compressed R-value of the Insulation from <br /> Appendix Table A101,4 shall not be less than the R-value specified In the table. CONSULTANT: <br /> This project will use the requirements of the Prescriptive Path below and incorporate the r,The fenestration U-factor column excludes skylights.The SHGC column applies to all glazed fenestration. <br /> the minimum values listed.In addition,based on the size of the structure,the appropriate <br /> number of additional credits are checked as chosen by the permit applicant. Exception:Skylights may be excluded from glazed fenestration SHGC requirements in Climate Zones 1 <br /> through 3 where the SHGC for such skylights does not exceed 0.30, <br /> Authorized Representative Date it"10/15/21.+TB"" means R-10 continuous Insulation on the exterior of the wall,or R-15 on the continuous <br /> insulation on the interior of the wall,or R-21 cavity Insulation plus a thermal break between the slab and the--All Climate Zones <br /> R-Va lute U-Factor' basement wall at the interior of the basement wall."10/15/21,+TB shall be permitted to be met with R-13 <br /> Fenestration U-Factor° nla 0.30 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or <br /> Skylight U-Factor nla 0.80 exterior of the wall. "10/13" means R-10 continuous insulation on the interior or exterior of the home or R- <br /> Glazed Fenestration SHGCb1 rile n/a 13 cavity insulation at the interior of the basement wall. "TB" means thermal break between floor slab and <br /> Ceiling 49' 0.025 abasement wail, <br /> Wood Frame Walls'R'' 21 int 0,056 R-10 continuous insulation is required under heated slab on grade floors.See R402,2,9.1. <br /> Mass Wall R-Value' 21/21" 0.056 'There are no SHGC requirements in the Marine Zone. <br /> Floor 309 0.029 r Basement wall insulation is not required in warm-humid locations as defined by Figure R301.1 and Table D <br /> Below Grade Wall°R 10/15/21 Int+TS 0.042 R301.1. <br /> flab°-F2 ue&Depth 10,2 it n/a *Reserved. <br /> 'Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2. h „ �f <br /> Each dwelling unit In one and two-famllyv dwalllnrrs and townhouses,as defined in Seddon 101.2 of theFirst value Is cavity insulation,second is continuous insulation or insulated siding,so 13.+5 means R-13 <br /> International Residential Code shall comply with strfflcllent options from Table R406.2 so as to achieve the cavity insulation plus R-5 continuous insulation or insulated siding. If structural sheathing covers 40 percent <br /> following minimum number of credits: or less of the exterior,continuous insulation R-value shall be permitted to be reduced by no more than R-3 in REGISTRATION STAMPS: <br /> the locations where structural sheathing is used to maintain a consistent total sheathing thickness. <br /> al,Smell Dwelling Unit: 0.8 points <br /> Dwelling units less than 1500 square feet In conditioned floor area with less than 300 square feet of fenestration r The second R-value applies when more than half the Insulation is on the interior of the mass wall, <br /> area, Additions to existing building that are less than 750 square feet of heated floor area. 1 For single rafter-or Joist-vaulted ceilings,the insulation may be reduced to R-38. <br /> 02,Medium Dwelling Unit: 1.6 points k int, (intermediate framing)denotes standard framing 16 inches on center with headers insulated with a <br /> All dwelling units that are not included in#1 or#3,Including additions over 750 square feet. <br /> minimum of R-10 Insulation. <br /> c fl3. Large Dwelling Unit: 2.6 points 5000 square feet of conditioned floor area. r <br /> Dwelling unite fs0 Log and solid timber walls with a minimum average thickness of 3,5 inches are exempt from this insulation <br /> exceeding <br /> requirement. PROJECT IDENTIFICATION: <br /> 124. Dwelling unit other than one and two-family dwellings and townhouses: Exempt <br /> As defined In Section 101.2 of the International Residential Code <br /> Table R402.1.3 Footnote 2322 CEDAR STREET <br /> Table R408.2 Summary EVERETT, WASHINGTON <br /> Option Description Credit(s) <br /> Nonfenestration U-factors shall be obtained from measurement,calculation or an approved source or as <br /> 1a Efficient Building Envelope 1s 0.8 ❑ specified in Section R402.1,3. c <br /> lb Efficient Building Envelope lb 1.0 ❑ <br /> 1c Efficient Building Envelope 1c 2.0 [] <br /> 2a Air Leakage Control and Efficient Ventilation 2a 0.5 ❑ <br /> 2b Air Leakage Control and Efficient Ventilation 2b 1.0 ❑ <br /> 2c Air Leakage Control and Efficient Ventilation 2c 1.5 ❑ <br /> 3a High Efficiency HVAC 3a 0.5 ❑ <br /> 3b High Efficiency HVAC 3b 1.0 ID <br /> 3c High Efficiency HVAC 3c 2,0 0 <br /> 3d High Efloi ncy HVAC 3d 1.0 ❑ - <br /> 4 High Efficiency HVAC Distribution System 1.0 0 <br /> 5.9 Efficient Water Heating 0.5 Cl 0.5 <br /> fib Efficient Water Heating 1.5 0 t This drawing is: <br /> f1I� 1.Copyright 2018 MAS Design Studio. <br /> 8 Renewable Electric Energy 0.5 1*1200 kwh 0.0 2.The Designers Instrument of Professional Service. <br /> ■� <br /> 3.For use on this project only.Obtain Designers written <br /> Total Credits tl.ffl? permission for any other use or reproduction. <br /> B *Please refer to Table R406.2 for complete option descriptions ISSUED: <br /> htto:/lwww.enerev.wsu.edu/Documents/Table 406 2 Enersv Credits 2012 WSEC.odf MARK DATE I DESCRIPTION <br /> - I OWNER APPROVAL <br /> - I PERMIT APPLICATION B <br /> - I BIDDING <br /> - I CONSTRUCTION <br /> - I - <br /> - I - <br /> - I - <br /> Ta ble 406 . 2 i <br /> _ I _ <br /> - I - <br /> Credits <br /> Energy oe r PROJECT NUMBER: I 1B.02 <br /> APPROVED BY: r <br /> PROJECT DIRECTOR: 1 <br /> PROJECT <br /> OPTION DESCRIPTION CREDIT(S) Estimated Cost CHECKED BY.ARCHITECT: I <br /> CHECKED BY. <br /> JOB CAPTAIN: r <br /> 5a <br /> DRAWN BY: r MAS <br /> EFLICIENT rATER HEA 'I TG 5a, DRAWING TITLE <br /> All showerhead and kitchen sink faucets installed in the house shall be rated at 1.75 2015 <br /> A GPM or less. All other lavatory faucets shall be rated at 1 .0 GPM or less.` WSEC A <br /> To qualify to claim this credit, the building permit drawings shall specify the option Compliance <br /> being selected and shall specify the maximum flow rates for all showerheads, kitchen DRAWING NUMBER: <br /> sink faucets. and other lavato faucets. <br /> _ CITY OF EVERETT A6.2 <br /> R -V1EWED FOR PERMIT <br /> 1 I 2 I 3 I 4 I 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.