Laserfiche WebLink
Q <br /> LL <br /> R -QH S "CAL \ S3 -CTO \ S A\ D TEST 9 -R BC 2315 w <br /> Q <br /> INDICATED ITEMS REQUIRING SPECIAL INSPECTION ARE IDENTIFIED UNDER COLUMNS "FREQUENCY OF INSPECTION" L,J <br /> AS PERIODIC OR CONTINUOUS OR UNDER COLUMNS INSPECTION ACTION AS PERFORM OR "OBSERVE". IF oc <br /> NO BOX IS CHECKED, EITHER THE TASK DOES NOT EXIST OR DOES NOT REQUIRE ANY SPECIAL INSPECTION. z <br /> w <br /> Q <br /> (z <br /> C0\CETE CO\STUCTIO\ (I3C 1705.3 & 1705. 12. 1 ) : r <br /> I <br /> ITEM FREQUENCY OF INSPECTION INSTRUCTIONS <br /> IsJ <br /> REINFORCING STEEL CONTINUOUS PERIODIC X VERIFY PRIOR TO PLACING CONCRETE THAT <br /> REINFORCING IS OF SPECIFIED TYPE, GRADE AND <br /> SIZE; THAT IT IS FREE OF OIL, DIRT AND RUST; THAT IT pc <br /> IS LOCATED AND SPACED PROPERLY; THAT HOOKS, <br /> BEND, TIES, STIRRUPS AND SUPPLEMENTAL W <br /> REINFORCEMENT ARE PLACED CORRECTLY; THAT <br /> to <br /> LAP LENGTHS, STAGGER AND OFFSETS ARE <br /> PROVIDED; AND THAT ALL MECHANICAL <br /> CONNECTIONS ARE INSTALLED PER THE <br /> MANUFACTURER'S INSTRUCTIONS AND/OR <br /> EVALUATION REPORT. <br /> CAST-IN BOLTS & EMBEDS CONTINUOUS X PERIODIC INSPECTION OF ANCHORS OR EMBEDS CAST IN <br /> CONCRETE IS REQUIRED WHEN ALLOWABLE <br /> LOADS HAVE BEEN INCREASED OR WHERE <br /> STRENGTH DESIGN IS USED. <br /> POST-INSTALLED ANCHORS OR CONTINUOUS N PERIODIC ALL POST-INSTALLED ANCHORS/DOWELS SHALL <br /> DOWELS BE SPECIALLY INSPECTED AS REQUIRED BY THE <br /> APPROVED ICC-ES REPORT. <br /> USE OF REQUIRED MIX DESIGN CONTINUOUS X PERIODIC VERIFY THAT ALL MIXES USED COMPLY WITH THE <br /> APPROVED CONSTRUCTION DOCUMENTS; ACI <br /> 318;CH 4, 5.2-5.4; AND IBC 19004.3, 19.13.2, 1913.3. <br /> CONCRETE SAMPLING FOR STRENGTH CONTINUOUS X PERIODIC <br /> TESTS, SLUMP, AIR CONTENT, AND <br /> TEMPERATURE <br /> CONCRETE PLACEMENT CONTINUOUS PERIODIC Vv <br /> CURING TEMPERATURE AND CONTINUOUS [X PERIODIC VERIFY THAT THE AMBIENT TEMPERATURE FOR <br /> TECHNIQUES CONCRETE IS KEPT AT > 50°F FOR AT LEAST 7 <br /> DAYS AFTER PLACEMENT. HIGH-EARLY- <br /> STRENGTH CONCRETE SHALL BE KEPT AT >50'F <br /> FOR AT LEAST 3 DAYS. ACCELERATED CURING <br /> METHODS MAY BE USED (SEE ACI 318:5.11.3). THE <br /> AMBIENT TEMPERATURE FOR SHOTCRETE SHALL BE <br /> >40T FOR THE SAME PERIOD OF TIME AS NOTED FOR <br /> CONCRETE. SHOTCRETE SHALL BE <br /> KEPT CONTINUOUSLY MOIST FOR AT LEAST 24 <br /> HOURS AFTER SHOTCRETING. ALL CONCRETE <br /> MATERIALS, REINFORCEMENT, FORMS, FILLERS, <br /> AND GROUND SHALL BE FREE FROM FROST. IN <br /> HOT WEATHER CONDITIONS ENSURE THAT <br /> APPROPRIATE MEASURES ARE TAKEN TO AVOID <br /> PLASTIC SHRINKAGE CRACKING AND THAT THE <br /> SPECIFIED WATER/CEMENT RATIO IS NOT <br /> EXCEEDED. <br /> ERECTION OF PRECAST CONCRETE CONTINUOUS PERIODIC M VERIFY THAT ALL PRECAST ELEMENTS ARE LIFTED, <br /> ASSEMBLED AND BRACED IN ACCORDANCE WITH <br /> THE APPROVED CONSTRUCTION DOCUMENTS. <br /> FORMWORK CONTINUOUS PERIODIC X VERIFY THAT THE FORMS ARE PLACED PLUMB <br /> AND CONFORM TO THE SHAPES, LINES, AND <br /> DIMENSIONS OF THE MEMBERS AS REQUIRED BY <br /> THE APPROVED CONSTRUCTION DOCUMENTS. <br /> i <br /> r s <br /> { <br /> a '' <br /> its <br /> � <br /> 3 fi <br /> Architects <br /> p� ygq ®pc Inc. opyright o 2019 <br /> Thisitemhasbeenelectronically signed and sealed by AI c ii ects Engineers,J, i <br /> (Andrew H.Miller,PE)usinga digital signature and date. <br /> State of Washington <br /> printed copies/e this document are not considered <br /> signed and sealed and thesignaturzmustbeverifiedon L9nnnwood,Washington,98036 Certificate of Authorization <br /> any electronic copies. y g Architecture No.603235512 <br /> 425 921-3500 Engineering No.3137��RY DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE cz_c 0� WASH�j ACCEPTABILITY BHECKED 09/17/19 STATEMENT OF SPECIAL INSPECTIONS A 09/17/19 <br /> A ISSUE FOR PERMIT - 767 RATE INCREASE FA BEL AHM 09/17/19 a ... f; iry 6r c ( THIS DESIGN AND/OR LAL 09/17/19 SHEET <br /> ir 4, ;+ SPECIFICATION IS APPROVED ENGINEER TITLE 767 RATE INCREASE — FA <br /> 2p <br /> ' �'�� ® (Z44... APPROVED BY DEPT. DATE CHECKED 09/17/19 <br /> 7" r°71 <br /> BUILDING 40 022 <br /> 12, „ 51998 �� APPROVED JOB NoEVE-18-30055-602 COMP NO. <br /> F ISTE <br /> v,�s�ONA L �� � APPROVED STRUCTURAL MASTER EVERETT, WA DWG No. 40-022—S2p-602 <br /> anm• Ex®u rch 3 <br />