LEGEND .‹
<br /> 15A, 120V, 1 PH, 'HAWORTH' SYSTEM FURNITURE cn
<br /> �\ DUPLEX RECEPTACLE. cu
<br /> L_
<br /> 2V22-7BD2/1a,3b,5c 2V22-7BD2/130,15b,17c VESDA PANEL © GENERAL NOTES a,
<br /> 3/4"C, 6#10, 1#10G 3/4"C, 6#10, 1#10G 2V22-7BD2/25a,27b,29c -'-'
<br /> (TYP 10) 2V22-7BD2 3/4"C, 6#10, 1#10G EPS R1 CC
<br /> LMR-�:: COAX © 7a 19a --0o l', ,� T 3 4" MINIMUM FOR ALL
<br /> in■ _ ® ■ C ■ _ :y - - ` - - - -- D 1 . CONDUIT. 1/2 MINIMUM, /
<br /> 21bjil : 4 21b 21 b . � 4 23c 23c 9b CO 45 KVA 23c PANEL 2V22 12AD3 25a HOMERUNS UNLESS NOTED OTHERWISE. 3/4" FLEX WITH
<br /> 25a
<br /> - _ GROUND WIRE.
<br /> �«ira — — — �A) - `!� 10 XE2V22-6UD7 1 1 I
<br /> � •� - * 11b 2v22-12AD3/9b u MECH. 23 2. CONDUCTORS SHOWN: 12 AWG STRANDED COPPER,
<br /> VI/LAN ELECTRONICS 11 b A,g (2) I 3 4 C 2; 10 1 ; 1 OG T KEEPO , 3 4 C 2 10, 110G �,�/ r
<br /> ENCLOSURE' (2) 2V22-7BD2/7a,9b,11c 2V22-7BD2/19a,21b,13c BATTERY CHARGER
<br /> WLAN DIRECTIONAL Nrirgiririrmv75 KVA i i 70NE •
<br /> �! N INSULATION TYPE THHN/THWN, UNLESS OTHERWISE _
<br /> 3/4"C, 6#10, 1#10G 3/4"C, 6#10, 1#10G 30-118929 ANTENNA',C� 30'-0" AFF
<br /> WLAN ELECTRONICS 1/2" LMR-600 COAX NOTED.
<br /> i /
<br /> �! /
<br /> ENCLOSURE � 3. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS
<br /> WLAN OM''NI-DIRECTIONAL (2)4-PAIR CAT5E UTP Iz
<br /> LAN OMNI-DIRECTIONAL ANTENNA'© 10'-O" AFF WHICH DO NOT HAVE APPROPRIATELY COLORED o
<br /> NTENNA 10'-0" AFF 2V22-12BUD3/11 b INSULATION WITH COLOR TAPE WHEREVER CONDUCTORS Li
<br /> ,,, 2V22-12BUD3-1 CKT. 21,23
<br /> ARE ACCESSIBLE. IDENTIFY INSULATED GROUND w
<br /> .•• CHATSWORTH BOX CONDUCTORS PER NEC USING TAPE.
<br /> 6'-0" AFF. COLOR CODE AS FOLLOWS: cn
<br /> 208Y/120V 480Y/277V
<br /> ° d A 0 (LEFT BUS IN PNL) BLACK BROWN
<br /> ° 1
<br /> B 0 CENTER BUS IN PNL) RED ORANGE
<br /> C 0 (RIGHT BUS IN PNL) BLUE YELLOW
<br /> NEUTRAL WHITE GRAY
<br /> EQUIPMENT GROUND GREEN GREEN
<br /> ISOLATED GROUND GRN/YEL* GRN/YEL*
<br /> I *GREEN WITH YELLOW TRACER
<br /> I
<br /> 0 4 4. DYMO LABEL EACH RECEPTACLE, JUNCTION/OUTLET
<br /> BOX AND SWITCH WITH CIRCUIT IDENTIFICATION.
<br /> I
<br /> 5. POST NEW OR REVISED PANEL SCHEDULES UPON
<br /> o COMPLETION OF JOB.
<br /> U
<br /> CD
<br /> CD
<br /> 6. UPON COMPLETION OF JOB RETURN REDLINES TO
<br /> ENGINEERING.
<br /> II d
<br /> J
<br /> INCONSTRUCTION NOTES
<br /> L__, ______
<br /> 1 ,_
<br /> __,_,
<br /> -0 ---o o -o-a - o-o -----o 0 _-_ c�0 e-®----- -0-Cr o� o o-cr o rr a �0 -- 00•••• i t
<br /> EPS-R1 RELOCATED FROM GRID LINE E/5.
<br /> tir - 1 t © VESDA PANEL RELOCATED FROM GRID LINE E/5.
<br /> — -0—Q— _0,9 _O.0 -0 t, — `0-.0 0 f_0— ——I——--—_0_0_ 0_ 0_____ 9 l EC". C19 9 O
<br /> \ PANL2V22/1AD2
<br /> PROVIDE HANNAY REEL CAT# NSCR715-15-16-17C WITH
<br /> 1 35 FEET 3/C #12 SO CORD, BALL STOP AND 20A 120V
<br /> IN THE; TRENCH d CONNECTOR.
<br /> .
<br /> I
<br /> i
<br /> I
<br /> r 1
<br /> i1
<br /> 1I
<br /> 11
<br /> 1
<br /> I
<br /> P Q .
<br /> 1
<br /> I
<br /> 11
<br /> i I E tilt Mt-th
<br /> I 1
<br /> IE tI1 lE III ii
<br /> lir iil ___ _lE n l
<br /> _ _ _ 1 1 1 I 1
<br /> 1 1--- 1
<br /> I ��
<br /> 1 1
<br /> 0 0
<br /> I 1 C
<br /> I II w
<br /> I II
<br /> 1
<br /> I , N
<br /> I
<br /> i N
<br /> D d CD
<br /> I ( _ O O
<br /> C,
<br /> c,
<br /> ....._....
<br /> Z
<br /> 1 J
<br /> , , ��\ o d REFERENCE NOTES
<br /> WLAN DIRECTIONAL Q
<br /> ANTENNA it 1 3 5 7 9 11
<br /> 14.5dbi ® 6'-0". ' ' O
<br /> r^* li> i7ni nIE!ii1 T ? TTTT
<br /> 0 1 O
<br /> I , I
<br /> c in l
<br /> ,
<br /> 4 11 1 f(4 1E61 i 1E62 l% 1E63 1E64
<br /> ,
<br /> a
<br /> /
<br /> `1 11 , I 1 1 1
<br /> I I I b g 1E65 ! 1E66 ! 1E67 ! 1E68 ! 1E69
<br /> I 1� / I I I I
<br /> \ �_ ` / 1E70 1E71 ; 1E72 ; 1E73 ; 1E74 400111
<br /> Pi e4 \ \WI \ //./ .
<br /> •
<br /> . \ 1 \ // // KEY PLAN BLDG. 40.22
<br /> �� 11 I SCALE: NONE N
<br /> 4'4 \ \ \ I �i b d
<br /> 4 - 8' 4' 0 4' 8' 1 6'
<br /> \te4 \ 42 \So i * \ \ : \ &Nmy 1
<br /> •
<br /> =- ' y SCALE: 1 8„ 1 ,-0„
<br /> I \ ;$ \\----i-r,---.4 \
<br /> � 1
<br /> 1 r___, O; 0 f1
<br /> ,., ' o a
<br /> 1 H
<br /> 4_
<br /> 1� ! 1/ i 1. .III tllEeti www.brph.com 0 PY ght©20 o ri 19
<br /> MATCH LINE (DWG 40-22-1E65)
<br /> PART AL 2 0 8 Y / 12 0 V O W L R A\ p� Architects Engineers, Inc.
<br /> State of Washington
<br /> \ 19020 33rd Ave W,Suite 530
<br /> SCALE: 1/8"=1 '—0" 425 Lynnwood, Certificate of Authorization
<br /> Washington,98036 Architecture No.603235512
<br /> 92135 O
<br /> \\\ , \ Engineering No.3137
<br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE
<br /> - p,RIE Sc THIS ESIGNBND R HBECKED o9/17/19 PARTIAL 208Y/120V POWER PLAN A 09/17/19
<br /> A Issue For Permit - 767 Rate Increase FA VTB SMS 09/17/19 s s. law°F wnsyl" ' 'C� SPECIFICATION IS APPROVED
<br /> BLB 09/17/19 SHEET
<br /> q� ENGINEER TITLE 767 RATE INCREASE - FA
<br /> "I"E�,�," ® r ', V` � APPROVED BY DEPT. DATE SMS 09/17/19 1 E60 -602
<br /> ' 4 ,� — CHECKED
<br /> �� , �1 1 APPROVED BUILDING 40-022 JOB NO. — COMP NO.
<br /> o.,� 4crsTE.W tip' EVE-18-30055-602
<br /> �sSIGNAL APPROVED ELECTRICAL MASTER COL. D-D.5/.9-3 EVERETT, WA DWG NO. 40-022-1E60-602
<br />
|