og
<br /> L_ 3E \ 3
<br /> 0 F 20A, 208VAC, 2-POLE, 3-WIRE GROUND cu
<br /> RECEPTACLE, HUBBELL #HBL2320SW WITH #F1-20214-!)
<br /> FEED THRU METALLIC BACK BOX.
<br /> rI i SEE DWG 40-22-1E60
<br /> 1AW 1 110 POWER/DATA POLE, SEE DETAIL 7, SHEET E511 0
<br /> CC
<br /> g 1It4,4 \1, I \ 4'Nr, 1 11 I ' O JUNCTION BOX (AS NOTED)
<br /> 15A, 120V, 1 -PHASE, FOUR-PLEX RECEPTACLE,
<br /> I p q9 I HUBBELL #5262-I (2) F-
<br /> ►_'`
<br /> it / / 1:4 I 1 DED
<br /> / / CL
<br /> 1 1 ID
<br /> 20A, 120V, 1 -PHASE, FOUR-PLEX RECEPTACLE, Iz
<br /> / / *A 1 ! DEDICATED NEUTRAL, HUBBELL #5362 (2)
<br /> \\\
<br /> I // jj 0 I k 15A, 120V, 1 -PHASE, DUPLEX RECEPTACLE, 0
<br /> \\\ P
<br /> ':. I II e►": j HUBBELL #5262-I w
<br /> ti.4" \ i \
<br /> 15A, 120V, 1 -PHASE, DUPLEX RECEPTACLE, cn
<br /> �� ' i 1 �� f HAWORTH SYSTEM FURNITURE SUPPLIED.
<br /> I 1
<br /> j
<br /> I
<br /> ', / N...y
<br /> ;j/ G =\ =PAL \ OYES
<br /> ?' it '\ j j j P P 1 . RACEWAYS: 1/2" EMT MINIMUM, UNLESS OTHERWISE
<br /> NOTED. USE COMPRESSION CONNECTORS AND
<br /> ® ' \\ / / I COUPLINGS.
<br /> i
<br /> j /' I
<br /> .... i / /
<br /> 4. E1.0F_ AA' I/
<br /> 2. CONDUCTORS SHOWN: #12 AWG, STRANDED COPPER,
<br /> I INSULATION TYPE THHN/THWN, UNLESS OTHERWISE to lil
<br /> iiiibe
<br /> ' NOTED.
<br /> '�"I �`� 99 3. WHERE SPECIFIED, PROVIDE A SEPARATE DEDICATE
<br /> D
<br /> 1 \ NEUTRAL FOR EACH DEDICATED CIRCUIT. NEUTRALS
<br /> I�I ��� � I I SHALL BE WHITE WITH A TRACER COLORED SAME AS
<br /> i i 1
<br /> �_ TamI I 9 I ASSOCIATED PHASE CONDUCTOR.
<br /> = I 4,#;'� I cn
<br /> .,_-. I I w
<br /> LIE :�� i ,,.:'� I i N ' 4. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS
<br /> �% r
<br /> - �`�� ,�, _ .• � - -— — j QP q9 w N WHICH DO NOT HAVE APPROPRIATELY COLORED
<br /> t�ili�tl ititlti tmi ■Its ins iii= iiit i 1! — t�tntt/t iO.ut�tnttpM�tntltnt�tiut.nt�t
<br /> • .- do sJ o INSULATION WITH COLOR TAPE WHEREVER CONDUCTORS
<br /> ,� ...ilk � i �� � � �iiil�ll�u�,, :;,
<br /> aai` i �,: - 'ii::; I ,�L� ..._. - - - _..._.._.._..�., . :. _ I I GROUND
<br /> i \ \ ��� i, ��`' II��,,,I�� �I��,,�� il�l � I I ARE ACCESSIBLE. IDENTIFY INSULATED
<br /> I • I •_' - I 1-- CONDUCTORS IN ACCORDANCE WITH THE LATEST NEC
<br /> / j III i
<br /> ram\j
<br /> I I I w (USING TAPE). COLOR CODE AS FOLLOWS:
<br /> •t ,,, I I 208Y 120V 480Y/277V
<br /> I / / \ � ,,- A� LEFT BUS IN PNL) BLACK BROWN 77V
<br /> I i j / �� tij►'
<br /> /
<br /> / j/ \- ;.ti :' ::.:a :::I* tiff :: ti.�: R" r ..�-.-...�,.;. ' - 'A .11r - . -.- IIP' M. -.- .-..-. B� (CENTER BUS IN PNL) RED ORANGE
<br /> 2
<br /> ° I j /j j ♦ •�i►.����i�� �'i►►.� ►�i.�.�.� ►k .0..� �.4►. .���411. i► Alb, • ►R.►ti��o.'Ri•�it � i&d►%► •►. . 11 I
<br /> /j j 2V22-7BE2/22b 1 I CO (RIGHT BUS IN PNL) BLUE YELLOW
<br /> ��j ��j jj 3/4 C, 2#10 & 1#1OGND I I NEUTRAL WHITE GRAY
<br /> EQUIPMENT GROUND GREEN GREEN
<br /> �"NW.,f� jj• ! I I ISOLATED GROUND GRN/YEL* GRN/YEL*
<br /> j/ ///o ! I *GREEN WITH YELLOW TRACER
<br /> j jj j
<br /> j j j j j I p I 5. DYMO LABEL EACH RECEPTACE, JUNCTION/OUTLET BOX
<br /> °\ I AND SWITCH WITH CIRCUIT IDENTIFICATION. LABEL
<br /> . ,IjOitk / I 1
<br /> I SYSTEM FURNITURE RECEPTACLES FOR PURPOSE, I.E.
<br /> •
<br /> `
<br /> I 1
<br /> ua COMPUTER (DEDICATED CIRCUIT) OR GENERAL POWER
<br /> I I I I USE.
<br /> 1 I 1 1 ICI
<br /> I I ' q I 6 > (1) 2 CONDUIT FROM CHATSWORTH TO CABLE
<br /> I _ _. _ _ _ • ! _ _ _ I I I _ _ _ _ _ I L TRAY IN TRANSPORTATION AISLE CEILING AND
<br /> o o v v U - -Il - - -0 0- - - - - -�- - - - 0--0 - 0 0-0- - -0-0 - - - ANOTHER (1) 2" CONDUIT TO EXISTING CABLE TRAY
<br /> if I LOCATED IN FLOOR TRENCH.
<br /> L
<br /> II
<br /> I r Te CO \ STR CIO \ \ OT-S
<br /> I
<br /> P 9 EPS-R3 (AKA EPS #3) REPLACED WITH NEW EPS
<br /> I PANEL. RE-CONNECT TO EXISTING CIRCUIT.
<br /> I I I
<br /> 1 I RINDPROVIDE HANNAY REEL CAT# NSCR715-15-16-17C
<br /> 3/4" RGS CONDUIT ONLY W/PULL CORD I
<br /> 1 WITH 35 FEET 3/C #12 SO CORD, BALL STOP AND
<br /> i II 20A 120V CONNECTOR.
<br /> 1 P
<br /> V2P1 P T . TEDT . ® @ji,
<br /> 113E.1 .5/37,39 2V22-7BE2/7a,9b,11c 2V22-7BE2/19a,21b,13c -� 4 10, 1 10G d _ faT2
<br /> 3/4'C, 6#10, 1#1 oG 3/4'C, 6#10, 1#10G / 'I # # I
<br /> 3V22-7BE2 1 a,3b,5c / I
<br /> „ / # 2V22-7BE2 13a,15b,17c 2 DU ' 'EX RECEPTACLES • I I 17 mall A '' -----7-------1------7--------E----- 0
<br /> 3/4 C, 6#10, 1#10G J �+ ._ N' - 1 E60 1 E61 1 E62 1 E63 1 E64
<br /> ■� , lq.q'11� 1��
<br /> 120V, DEDICATED Eye ;a #b 8a lob '
<br /> i IOA#
<br /> PANEL 2V22-13E1 .5 14a '= — m;, _ � I 1
<br /> (2) DEDICATED • '+ � • -- 1 E65 1 E66 i 1 E67 1 1 E68 i 1 E69
<br /> (TYP 10) t.It III I 1 14a .-=' -li0 .-a b),' - 1 N 1. ,
<br /> 6 I I RECEPTACLES _ � Z �_� — — �— — . — — 1 —
<br /> ❑ CHATSWORTH BOX
<br /> 1 E65 E536 20A 120VOLT 14a �- ! _ I I_ ml _ _��J 1 E70 1 E71 1 E72 1 E73 1 E74 eta
<br /> la 3b 5c 7a 9b 11 c 13a 15b 17c 19a s ii _ _� QT,�___ _ 14:1
<br /> - . „ ! i 2V22-13VE 1 6 —0 AFF. 14a i ".�,_ _ _q q4. H ,_.
<br /> _ I - iII -�1 KEY PLAN BLDG. 40.22
<br /> S. I /2>4 _�` I! rn..• _ _ SCALE: NONE N
<br /> — I — �p
<br /> 13U F2 4m1 Jim , - 16b „ ,_�... b��i "� ' lJ � �c-
<br /> 76) DUPLEX REC. ON (2) DED. CKTS. #10 3 4 C / " , # 0 1#10G
<br /> meiD 2V22-13E3 9b,11 c 2V22-7BE2/16b I o q- I ; ! � � 8' 4' 0 4' 8' 16'
<br /> x- -1_ 2V22-8BE3.25 25,27,29
<br /> XE2V22 7AUF2/1 a _ / 3/4 C 3#10, 1#10G -tin ._ �1_ —2v22 1 V
<br /> E1/7a 3/4„c, 2#10 & 1#10GND 2 , 4• /0 SEE DETAIL 1 , SHY. 40-22-E536 I t 1sb - - , n; �..,i , „ ;1 h�4• ' ; = „
<br /> 3bt� T ., SCALE. 1/8 =1 -0
<br /> / 9• .11 c 2V22-13E1.5/1 1 c _ v - m
<br /> in 2V22-7BE2 1
<br /> ttlI+48' 2V22-13VE1/68 21b 21b '� 23c 3/4C ' #23c& 1#IOGND �.� `iYet _;i 'a� �'� �.q� l �,K
<br /> �. l. 21 b 1 .3U�F2 3b _ ,., - - 1 .3UF2�3b • - t
<br /> i
<br /> i . .. 45 KVA CO L/ x x x -of x
<br /> ■� � PH
<br /> EPS-R3 A L t �.�� —
<br /> SEE DWG 40-22-1E70 1 .3UF2/3b 1 . ,a -
<br /> 3/4"C-TO COMM. CABL 'A' A . 2 1. FLR. CEIL'G www.brph.com Copyright©2019
<br /> A RT A 2 0 8Y/ 12 0� O W E R LA\ 1 .3UF2/3b 2V22-7BE2/18c 2V22-7BE2/2a,4b,6c 2V22-7BE2/8a,10b,12c 2V22-7BE2/14a \ 2V22-13E3 Architects Engineers,
<br /> 3/4"c, 2#10, 1#10G 3/4"C, 6#10, 1#10G 3/4"c, 6#10, 1#1oG 3/4"c, 2#10, 1 ° 10 Inc.
<br /> \ State of Washington
<br /> 19020 33rd Ave W,Suite 530
<br /> SCALE: 1 8 =1 '-0" F\\`\\ Lynnwood,Washington,98036 honzation
<br /> ArchecturCeficatee No.Aut603235512
<br /> 425-921-3500 Engineering No.3137
<br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE
<br /> oRW C ACCEPTABILITY VTB 09/17/19 PARTIAL 208Y/120V POWER PLAN A 09/17/19
<br /> A Issue For Permit — 767 Rate Increase FA VTB SMS 09/17/19 THIS DESIGN AND/OR CHECKED
<br /> s s w c� �� SPECIFICATION IS APPROVED BLB 09/17/19 SHEET
<br /> AOE,H� ® ENGINEER TITLE 767 RATE INCREASE - FA
<br /> APPROVED BY DEPT. DATE SMS 09/17/19
<br /> CHE 1 E 6 5
<br /> CKED
<br /> d'S �g 5/014 �p , APPROVED BUILDING 40-022 JOB NO. COMP NO.
<br /> GISTER EVE-18-30055-602
<br /> �sSIONAL APPROVED ELECTRICAL MASTER COL D.5-E/.9-3 EVERETT, WA DWG NO. 40-022-1E65-602
<br />
|