IF THESE SHEETS ARE NOT 24"X 36"THEN DRAWING IS NOT TO SCALE.
<br /> MATERIAL LEGEND GENERAL NOT
<br /> SYMBOL L LEGEND D _
<br /> EN
<br /> DIMENSION CONVENTIONS: (��
<br /> / WOOD BLOCKING SHIM I
<br /> �'�� WOOD FRAMING
<br /> (CONTINUOUS) 1. DO NOT SCALE FROM DRAWINGS. ��
<br /> NORTH ARROW NORTH 2. CONTROL DIMENSIONS FOR BUILDING LOCATION RELATIVE TO PROPERTY LINE AND BENCHMARK DATUM ARE SET BY THE ik-r,----
<br /> -
<br /> CIVIL DOCUMENTS.
<br /> FINISHED WOOD / 3. THE BUILDING DATUM IS AN ARTIFICIAL DATUM SET FROM THE SURVEY, CIVIL, TOPOGRAPHICAL CONTOURS, AND OTHER j\I
<br /> /. PLYWOOD DATUMS AS SHOWN ON THE CIVIL DOCUMENTS.
<br /> 4. CONTROLLING DIMENSIONS FOR THE BUILDING ARE NORMALLY SET BY THE"A" SERIES DRAWINGS. PRIMARY STRUCTURAL
<br /> RM
<br /> n ELEMENTS ARE NORMALLY SET BY THE"S" SERIES DRAWINGS. CONTRACTOR SHALL HAVE RESPONSIBILITY TO t
<br /> MEIY V
<br /> BAIT INSULATION �F RIGID INSULATION COORDINATE INFORMATION OF ALL DISCIPLINES TO DETERMINE EXACT DIMENSIONS, LOCATIONS,AND OTHER
<br /> sxr INFORMATION.
<br /> 5. THE STRUCTURAL DRAWINGS ARE TO BE USED IN CONJUNCTION WITH THE ARCHITECTURAL DRAWINGS. PRIMARY
<br /> STRUCTURAL ELEMENTS ARE DIMENSIONED ON THE STRUCTURAL DRAWINGS, PLANS AND DETAILS. NOT ALL SECONDARY
<br /> FOAMED IN PLACE GRID LINES DIMENSIONS ARE SHOWN ON THE STRUCTURAL DRAWINGS SUCH AS EXACT DOOR AND WINDOW LOCATIONS, WALL
<br /> SEMI RIGID INSULATION INSULATION ® CONFIGURATIONS, SLAB SLOPES AND DEPRESSIONS, CURBS, ETC. COORDINATION OF THE STRUCTURE WITH THE
<br /> . REFERENCE DIMENSIONS AS SHOWN ON THE DRAWINGS AND ARCHITECTURAL ITEMS TO BE EMBEDDED INTO, OR ATTACHED TO, THE
<br /> STRUCTURE IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR.
<br /> 6. DIMENSIONAL DISCREPANCIES BETWEEN THE ARCHITECTURAL AND STRUCTURAL DRAWINGS OR BETWEEN DIFFERENT
<br /> GRAVEL -I I I EARTH DRAWINGS WITHIN THE ARCHITECTURAL SERIES, OR DIMENSIONS WHICH ARE UNABLE TO BE DETERMINED, SHALL BE
<br /> REPORTED TO THE ARCHITECT BEFORE PROCEEDING WITH THE WORK.
<br /> 7. INTERIOR DIMENSIONS ARE AS NOTED FOR SPECIFIC OTHER DIMENSIONAL CONDITIONS. SET LAYOUT TO CONTROL POINTS
<br /> STEEL ALUMINUM ROOM REFERENCE OOM NAME
<br /> 8. OPEN DIMENSIONS: WHERE DIMENSIONS NOT GIVEN, LAY OUT TO KNOWN CONTROL POINTS AND LAY OUT OPEN
<br /> jj/ ROOM NAME//R AS GIVEN.
<br /> /j/f/
<br /> DIMENSIONS ACCORDINGLY.
<br /> C101 ROOM NUMBER 9. DIMENSIONS ARE TO GRID LINE OR TO FACE OF STRUCTURE UNLESS NOTED OTHERWISE IN PLANS.
<br /> 10. CONCRETE DIMENSIONS ARE TO FACE OR CONCRETE OR CENTER OF WALL.
<br /> CMU / BRICK 110 SF 11. STUD FRAMING DIMENSIONS ARE TO FACE OF STUD.
<br /> // AREA 12. DIMENSIONS WITH A"CLR" NOTATION DENOTE CLEAR DIMENSIONS TO FACE OF FINISH AT SPECIFIC LOCATIONS FOR CODE
<br /> COMPLIANCE. z
<br /> 0
<br /> GRAPHIC CONVENTIONS:
<br /> STONE ° - e CONCRETE aa.
<br /> d BUILDING SECTION 1. WALL ASSEMBLY TYPE SYMBOLS APPLY TO THE FULL LENGTH OF CONTINUOUS WALLS INCLUDING OFFSETS AND AROUND U H
<br /> A101 CORNERS UNLESS INDICATED OTHERWISE. w
<br /> cc
<br /> I 1 ' 2. CHANGES IN PARTITION TYPES ARE INDICATED BY DIFFERENT SYMBOLS OCCURRING AT EACH SIDE OF A TRANSITION OR o w
<br /> I I STONE INTERRUPTION, OR BY A CHANGE IN THE GRAPHICS ON THE PLAN.
<br /> 3. DRAWING REFERENCE SYMBOLS DRAWINGS CROSS-REFERENCES NORMALLY ARE REFERENCED ON SMALLER SCALE
<br /> WALL SECTION DRAWINGS TO THE NEXT LARGER SCALE VIEW. FOR EXAMPLE A BUILDING ELEVATION WILL SHOW A WALL SECTION, AND I w r
<br /> A101 THE WALL SECTION WILL REFER TO THE LARGER-SCALE DETAILS WHICH APPLY, U.O.N. I Q M
<br /> 4. REFER TO LARGEST AVAILABLE DETAIL OR VIEW TO DETERMINE COMPLETE ASSEMBLY, CONDITION AND/OR DIMENSION,
<br /> Ref AND FOR SIMILAR INFORMATION. WHERE DRAFTING DISCREPANCIES OCCUR BETWEEN VIEWS OF SAME CONDITION AT c-;')
<br /> DIFFERENT SCALES, THE LARGER-SCALE VIEW GOVERNS UNLESS NOTED OTHERWISE.
<br /> 5. DETAIL VIEWS MAY BE DRAFTED TO CONVEY ONLY PORTIONS OF THE OVERALL CONDITION AT A SPECIFIC LOCATION.
<br /> BUILDINGix
<br /> REFER TO OTHER SIMILAR AND SUPPORTING VIEWS TO DETERMINE OVERALL CONDITION OR ASSEMBLY IN PLACE.
<br /> ELEVATION 034 A101 DRAWING NOTATIONS 2
<br /> v1. TYP (TYPICAL): INDICATES THAT THE INDIVIDUAL ELEMENT NOTED OR REFERENCED IS REPRESENTATIVE OF LIKE ITEMS
<br /> Ref AND/OR CONDITIONS WHICH ARE SHOWN IN THE SAME DRAWING BUT FOR REASONS OF DRAFTING CLARITY ARE NOT DRAWN BY: KL
<br /> INDIVIDUALLY NOTED OR REFERENCED. 1
<br /> 1 Ref 2. SIM (SIMILAR): INDICATES THAT THE REQUIRED BUILT CONDITION DEPICTED IS SIMILAR TO BUT NOT IDENTICAL TO THE
<br /> REFERENCED VIEW. CHECK: LJ
<br /> INTERIOR 3. CONT (CONTINUOUS): INDICATES THAT THE ELEMENT OR CONDITION SO NOTED IS CONTINUOUS ALONG FULL EXTENT OF
<br /> ELEVATION 1 A101 1 OVERALL ASSEMBLY SHOWN. EXAMPLE: "SEALANT CONT." INDICATES THAT SEALANT SHALL BE APPLIED ALONG FULL
<br /> EXTENT OF SEAM TO FORM WEATHER-TIGHT SEAL.
<br /> 4. OPP (OPPOSITE): INDICATES THAT THE DRAWING REFERENCED IS DRAWN OPPOSITE-HAND TO THE CONDITION. WHEN NOTES:
<br /> 1 Ref USED IN CONJUNCTION WITH A NOTE, THE TERM REFERS TO CONDITION AT OPPOSITE SIDE OF DRAFTED CONDITION,AREA, OR ELEMENT. WHEN USED FOR A BUILT ITEM IT REFERS TO A CONDITION WHERE THE ITEM IS INSTALLED OR PLOT DATE: 7/20/2017 1:05:46 PM
<br /> 1A - - ' OPPERATED IN THE OPPOSITE DIRECTIONS, I.E. WINDOW OPERATION.
<br /> A101 5. CLR(CLEAR), INDIATES THAT THE DIMENSION PROVIDED IS TO FACE OF FINAL FINISH AS REQUIRED BY CODE OR JOB NO:
<br /> GOVERNING BODY.
<br /> ENLARGED PLAN OR I ADA 5215
<br /> DETAIL REFERENCE
<br /> 1. ALL CONTROLS FOR USE BY GUESTS (I.E. DOOR LATCHES AND THERMOSTATS) MUST BE MOUNTED AT B/T 15"A.F.F. &48"
<br /> -
<br /> - - A.F.F. & PROVIDE A 30"X 48"CLEAR FLOOR AREA IN COMPLIANCE W/ACCESSIBLE STANDARDS. OPERABLE CONTROLS '°" '`'' "�'"'''""`""''`A '�r ''
<br /> LOCATED OVER AN OBSTRUCTION DEEPER THAN 10" MUST BE MOUNTED NO HIGHER THAN 46"A.F.F. ACCESSIBLE ; R
<br /> Lk LEVEL NAME
<br /> CONTROLS MUST NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST&SHALL COMPLY W/THE ADAAG.
<br /> .''.!..1.....:.."..‘'.. I
<br /> LEVEL/ FLOOR REFERENCE 2. COMMON EMPLOYEE AREAS SUCH AS BREAKROOMS, LOCKER/TOILET/SHOWER ROOMS MUST BE ACCESSIBLE AND HAVE *.
<br /> ELEVATION ACCESSIBLE FEATURES AND FIXTURES. EMPLOYEE WORK AREAS LESS THAN 1000 SQ FT AS DEFINED BY PERMANENTLY ',
<br /> INSTALLED PARTITIONS, COUNTERS, CASEWORK OR FURNISHINGS ARE NOT REQ'D TO HAVE AN ACCESSIBLE PATH OF
<br /> SEE WALL CIRCULATION THROUGHOUT THE SPACE BUT ARE REQ'D TO BE CONSTRUCTED SO AN INDIVIDUAL CAN APPROACH, ENTER 1 1
<br /> WALL ASSEMBLY A01 �' SCHEDULE AND EXIT THE SPACE.
<br /> FOR ADD 3. IN COMMON SPACES WITHIN EMPLOYEE AREAS AT LEAST ONE OF EACH TYPE OF STORAGE OR WORK COUNTER, 5% OFit*Mindiliaftell
<br /> REFERENCE INFO LOCKERS&CONTROLS (EG. PHONES, CARD READERS, ETC.) MUST BE ON AN ACCESSIBLE ROUTE , WITHIN REACH RANGE
<br /> & MUST COMPLY W/STANDARDS FOR CONTROLS AS DEFINED IN THE GOVERNING ACCESSIBILITY STANDARDS OR LOCAL Jensen FeyCODE WHICHEVER IS STRICTER.
<br /> DOOR SYMBOL AND DOOR 101 4. OPERABLE PORTION OF CARD READER TO BE MOUNTED @ 48"OR BELOW W/CLEAR FLOOR SPACE FOR FRONT OR I Architecture and Planning
<br /> REFERENCE PARALLEL APPROACH. I 7730 LEARY WAY NE
<br /> 5. ALL SIGNS IDENTIFYING PERMANENT ROOMS OR SPACES ARE REQ'D TO HAVE VISUAL& RAISED CHARACTERS & BRAILLE. ! 1
<br /> TO BE MOUNTED ON LATCH SIDE OF DOOR W/THE LOWEST TACTILE CHARACTERS NO LOWER THAN 48" &THE BOTTOMOF REDMOND, WA 98052
<br /> W01 THE HIGHEST TACTILE CHARACTERS NO HIGHER THAN 60"AFF. TEL:425.216.0320 FAX 425.216.0329
<br /> WINDOW SYMBOL AND �✓ 6. ANY PORTION OF A WALL SCONCE OR OTHER OBJECT PROTRUDES INTO A CIRCULATION PATH ABOVE 27" & BELOW 80" IS
<br /> WINDOW SCHEDULE [T 5 En LIMITED TO A 4" MAX PROJECTION.
<br /> I-
<br /> REFERENCE 7. REFER TO HADG FOR ADDITIONAL REQ'S FOR PUBLIC SPACES & EQUIPMENT.
<br /> 8. IN PUBLIC AREAS INTENDED FOR DINING, AT LEAST 5%OF THE TABLES MUST BE ACCESSIBLE W/COMPLIANT KNEE&TOE LL]
<br /> CLEARANCE & LOCATED ON AN ACCESSIBLE ROUTE& DISTRIBUTED THROUGHOUT THE SPACE. (f)
<br /> FLOOR ASSEMBLY F01 9. ALL EQUIPMENT, FURNITURE & MILLWORK INTENDED FOR GUET USE MUST MEET ALL CLEARANCES & REACH RANGES AS
<br /> DEFINED BY THE GOVERNING ACCESSIBILITY CODE OR LOCAL CODE; WHICHEVER IS STRICTER.
<br /> REFERENCE 10. ALL OPERABLE WINDOWS PROVIDED IN PUBLIC GUEST ACCESSIBLE SPACES & IN ACCESSIBLE GUEST ROOM TYPES MUST
<br /> MEET ALL ACCESSIBILITY REQUIREMENTS PERTAINING TO REACH RANGE, OPERATING CONTROLS & CLEAR FLOOR SPACE-
<br /> FINISH MATERIAL MTL HARDWARE&WINDOW OPERATION MUST BE NO LONGER THAN 5 LBS.
<br /> \ > 11. PROVIDE ACCESSIBLE FLOOR TRANSITIONS @ ALL LOCATIONS WHERE THERE IS A CHANGE IN FLOORING MATERIAL OR @ CD W
<br /> 00
<br /> REFERENCE DOOR THRESHOLDS. THE CHANGE OF LEVEL B/T MATERIALS MUST BE NO MORE THAN 1/4" OR UPTO 1/2" IF SLOPED @ 1:2
<br /> 12. ALL DATA& POWER RECEPTACLES INTENDED FOR GUEST ACCESS/USE MUST BE INSTALLED W/IN ACC. REACH RANGES 00
<br /> -
<br /> REFER TO GENERAL NOTE# 1.
<br /> REVISION CLOUD AND
<br /> REVISION NUMBER PROTECTION UJ
<br /> 1. PROTECT ALL CONSTRUCTION MATERIAL FROM WEATHER DEGREDATION BEFORE, DURING, AND AFTER INSTALLATION. U
<br /> 2. PROTECT ALL PARTY WALL GYPSUM BOARD FROM RAIN AND MOISTURE DURING CONSTRUCTION. LL
<br /> CENTER LINE 3. PROVIDED ALL ENVIRONMENTAL CONDITIONS REQUIRED BY MANUFACTURERS BEFORE, DURING AND AFTER LL
<br /> INSTALLATION. 0 H 0
<br /> U
<br /> REVIATIONS z 1
<br /> SM SHEET METAL SYMBOLS BOT BOTTOM DET DETAIL FD FLOOR DRAIN H L NIC NOT IN CONTRACT PTN PARTITION SOG SLAB ON GRADE V ,� `W a-
<br /> BRG BEARING DIA DIAMETER FE FIRE EXTINGUISHER HB HOSE BIBB NO NUMBER PVC POLYVINYL CHLORIDE �/
<br /> @ AT BSMT BASEMENT DIM DIMENSION FEC FIRE EXTINGUISHER CABINET HC HOLLOW CORE LAM LAMINATE, LAMINATED NOM NOMINAL SPEC SPECIFICATION VB VINYL BASE _I LLJ !�
<br /> # POUND OR NUMBER BUR BUILT UP ROOFING DL DEAD LOAD FF EL FINISH FLOOR ELEVATION HDO HIGH DENSITY OVERLAY LAV LAVATORY NR NOISE REDUCTION R SPF SPRAY POLYURETHANE FOAM
<br /> VBM VAPOR BARRIER tt�
<br /> (E) EXISISTING SQ FT SQUARE FOOT(FEET) Q V
<br /> DN DOWN FH FIRE HYDRANT HDR HEADER LBS POUNDS NTS NOT TO SCALE MEMBRANE
<br /> SQ IN SQUARE INCH(ES) J-
<br /> (N) NEW C DR DOOR FHC FIRE HOSE CABINET HDWD HARDWOOD LF LINEAR FOOT(FEET) R RISER VEN VENEER SST STAINLESS STEEL W OD06
<br /> DR OPNG DOOR OPENING FIN FLR FINISH FLOOR HDW HARDWARE LH LEFT HAND 0 RA RETURN AIR VERT VERTICAL
<br /> STD STANDARD
<br /> A CAB CABINET DS DOWNSPOUT FF FINISH TO FINISH HM HOLLOW METAL LL LIVE LOAD RAD RADIUS VEST VESTIBULE f w
<br /> CB CATCH BASIN DSP DRY STANDPIPE FIN FINISH HORIZ HORIZONTAL LOC LOCATION OA OVERALL RD ROOF DRAIN STL STEEL VG VERTICAL GRAIN Z
<br /> STOR STORAGE
<br /> ABV ABOVAB E CER
<br /> BOLT CER CERAMIC DW D SHCEM CEMENT DT IWASHER FLAN TILE SH FLOOR; FLOORING HR HOUR POINTFLASHING HP HIGH LP LOW LT LIIGHT POINT OC ON CENTER REF REFERENCE OD OUTSIDE DIAMETER REFR REFR GERATOR STRUPCT STRUCTURAL VT V NVIF YIFY IN LT TILE FI ELD N < 0
<br /> ACC ACCESS CIP CAST-IN-PLACE DWG DRAWING FLUOR FLUORESCENT HT HEIGHT OVERFLOW DRAIN REG REGISTER U SUSPENDED
<br /> SYM SYMMETRICAL I ACOUS ACOUSTICAL CJ CONTROL JOINT FOC FACE OF CONCRETE HTSAM HIGH TEMPERATURE M OFF OFFICE REINF REINFORCED W '`�.
<br /> ACP ASPHALT CONCRETE PAVING CLG CEILING E FOF FACE OF FINISH SELF- ADHERED OH OVERHEAD REM REMAINDER
<br /> T I
<br /> ACS ACCESS PANEL CLK CAULKING FOIC FURNISHED BY OWNER- MEMBRANE MAS MASONRY OHWM ORDINARY HIGH WATER REQ REQUIRED W WEST
<br /> ACT ACOUSTICAL TILE CLO CLOSET E EAST INSTALLED BY CONTRACTOR HVAC HEATING, VENTILATION, & MATL MATERIAL MARK RESIL RESILIENT T TREAD W/ WITH r W
<br /> AD AREA DRAIN CLR CLEAR EA EACH FOM FACE OF MASONRY AIR CONDITIONING MAX MAXIMUM OPNG OPENING REV REVISION; REVISIONS; W/O WITHOUT W 1- I
<br /> T&G TONGUE AND GROOVE
<br /> ADA AMERICANS WITH DISABILITIES CMU CONCRETE MASONRY UNIT EJ EXPANSION JOINT FOS FACE OF STUDS HW HOT WATER MB MACHINE BOLT OPP OPPOSITE REVISED WC WATER CLOSET
<br /> TEL TELEPHONE > CV
<br /> ACT CNTR COUNTER EL ELEVATION FP FIREPROOF HWT HOT WATER TANK MC MEDICINE CABINET OSB ORIENTED STRAND BOARD RM ROOM WD WOOD
<br /> ADJ ADJUSTABLE COL COLUMN ELEC ELECTRICAL FPL FIREPLACE MDF MEDIUM DENSITY RO ROUGH OPENING TER TERRAZZO WDW WINDOW c)
<br /> TG TEMPERED GLASS
<br /> AFF ABOVE FINISHED FLOOR CONC CONCRETE ELEV ELEVATOR FR FRAME I FIBERBOARD P RWL RAIN WATER LEADER THK THICK WF WIDE FLANGE (f) Q
<br /> AGGR AGGREGATE CONN CONNECTION ENCL ENCLOSURE FT FOOR OR FEET ID INSIDE DIAMETER MDO MEDIUM DENSITY OVERLAY WF BM WIDE FLANGE BEAM
<br /> TO TOP OF...
<br /> AIB AIR INFILTRATION BARRIER CONST CONSTRUCTION EQ EQUAL FTG FOOTING IN INCH MECH MECHANICAL PBD PARTICLE BOARD S WG WIRED GLASS -- ----
<br /> ALT ALTERNATE CONT CONTINUOUS EQUIP EQUIPMENT FURR FURRING INCL INCLUDED MEMB MEMBRANE PCC PRECAST CONCRETE TOB TOP OF BEAM WH WATER HEATER
<br /> TOC TOP OF CONCRETE; CURB
<br /> ALUM ALUMINUM CONTR CONTRACTOR EST ESTIMATE FUT FUTURE INSUL INSULATION MEZZ MEZZANINE PCF POUNDS PER CUBIC FOOT S SOUTH WL WATER LINE
<br /> APPROX APPROXIMATE CORK CORRIDOR EW EACH WAY • FW FULL WIDTH INT INTERIOR MFR MANUFACTURER PERF PERFORATED SAF SELF-ADHERED FLASHING TOF TOP OF FLOOR; FOOTING; FEET:WLD WELDED
<br /> FRAME
<br /> ARCH ARCHITECTURAL CPT CARPET; CARPETED EXH FN EXHAUST FAN INV INVERT MIN MINIMUM PERP PERPENDICULAR SAM SELF-ADHERED MEMBRANE WP WATERPROOF
<br /> ASPH ASPHALT CRS COLD ROLLED STEEL EXIST EXISTING G TOM TOP OF MASONRY
<br /> MIR MIRROR PL PLATE SC SOLID CORE WPM WATERPROOF
<br /> AUTO AUTOMATIC CSK COUNTERSUNK EXP EXPADED; EXPANSION J MISC MISCELLANEOUS PLAM PLASTIC LAMINATE SCHED SCHEDULE TOP TOP OF PARAPET; PAVEMENTMEMBRANE
<br /> CT CERAMIC TILE EXP BT EXPANSION BOLT GA GAUGE MO MASONRY OPENING PLAS PLASTER SD SMOKE DETECTOR TOPO TOPOGRAPHY
<br /> WR WATER RESISTANT
<br /> B CTR CENTER EXPO EXPOSED GALV GALVANIZED JB JUNCTION BOX MTD MOUNTED PLWD PLYWOOD SECT SECTION TOS TOP OF SLAB; STEEL WRB WATER/AIR RESISTIVE
<br /> TOW TOP OF WALL
<br /> CU FT CUBIC FEET EXT EXTERIOR GC GENERAL CONTRACTOR JF JOINT FILLER MTL METAL PNL PANEL SG(I) SAFETY GLASS (INSULATED) BARRIER
<br /> BD BOARD GL GLASS JT JOINT MUL MULLION PNT POINT SHV SHELF; SHELVING TS TUBE STEEL WSCT WAINSCOT
<br /> TSTAT THERMOSTAT
<br /> BITUM BITUMINOUS D F GLAM GLUE-LAMINATED PR PAIR SHR SHOWER WSG WIRE SAFETY GLASS
<br /> TYP TYPICAL
<br /> BLDG BUILDING GR GRADE K N PRCST PRECAST SHT SHEET WTR WATER
<br /> BLKG BLOCKING DBL DOUBLE FA FIRE ALARM GWB GYPSUM WALL BOARD PSF POUNDS PER CUBIC FOOT SHT MTL SHEET METAL U WWF WELDED WIRE FABRIC
<br /> BM BEAM DEMO DEMOLITION FB FLAT BAR GYP GYPSUM KIT KITCHEN N NORTH PSI POUNDS PER SQUARE INCH SHTG SHEATHING WWM WELDED WIRE MESH
<br /> BO BOTTOM OF... KO KNOCKOUT N/A NOT APPLICABLE PT PRESERVATIVE TREATED SIM SIMILAR UNO or UON UNLESS OTHERWISE NOTED WT WEIGHT
<br />
|