IF THESE SHEETS ARE NOT 24"X 36"THEN DRAWING IS NOT TO SCALE. <br /> 2 X 12 LEDGER STRINGER <br /> 2 X P.T. BLOCKING \ SUPPORT f_ <br /> GYPSUM TOPPING AT STRUCTURAL c'. <br /> STAIR NOTES FLOOR - SEE FLOOR 5 1/2" CONNECTOR ;- �� <br /> ASSEMBLIES - f <br /> HEADROOM (IBC 1009.2): STAIRWAYS SHALL HAVE A MINIMUM HEADROOM CLEARANCE OF 80" MEASURED VERTICALLY FROM A LINE CONNECTING v,, ,,_ <br /> THE EDGE OF THE NOSINGS. SUCH HEADROOM SHALL BE CONTINUOUS ABOVE THE STAIRWAY TO THE POINT WHERE THE LINE INTERSECTS THE CARPET FINISH <br /> LANDING BELOW, ONE TREAD DEPTH BEYOND THE BOTTOM RISER. THE MINIMUM CLEARANCE SHALL BE MAINTAINED THE FULL WIDTH OF THE -SEE IFI \ <br /> STAIRWAY AND LANDING. HEADROOM: 2.03 M (6-8) MINIMUM atgieMOITI/1014,70 „ilrelaT :elf, , <br /> RISE AND RUN (IBC 1009,7.2!ICC A117.1 504.2): <br /> � •, :•, � • , 2" CONTRASTING <br /> 1. STAIR RISER HEIGHTS SHALL BE 7-INCHES MAXIMUM AND 4 INCHES MINIMUM. STAIR TREAD DEPTHS SHALL BE 11-INCHES MINIMUM. THE RISER V VINYL STAIR <br /> HEIGHT SHALL BE MEASURED VERTICALLY BETWEEN THE LEADING EDGES OF ADJACENT TREADS. THE TREAD DEPTH SHALL BE MEASURED 1" 11" NOSING <br /> HORIZONTALLY BETWEEN THE VERTICAL PLANES OF THE FOREMOST PROJECTION OF ADJACENT TREADS AND AT A RIGHT ANGLE TO THE REF SPEC & IFI <br /> TREAD'S LEADING EDGE. (SECTION 1009.7.2) FOR TYPE <br /> 2. STAIR TREADS AND RISERS SHALL BE OF UNIFORM SIZE AND SHAPE. THE TOLERANCE BETWEEN THE LARGEST AND SMALLEST RISER -- RISER WITH <br /> OD <br /> HEIGHT OR BETWEEN THE LARGEST AND SMALLEST TREAD DEPTH SHALL NOT EXCEED 3/8- INCH IN ANY FLIGHT OF STAIRS. (SECTION CARPET FINISH <br /> 1009.7.2) TIE .10) <br /> 3. OPEN RISERS ARE NOT ALLOWED. WE ARE ASSUMING CLOSED RISERS, A117.1-2009 SECTION 504,3 MA& * 4 i---- <br /> HANDRAILS (IBC 1009.12 & 1012/ICC A117.1 505): FLOOR - 5/4"TREAD PLANK <br /> 1. HANDRAIL HEIGHT, MEASURED ABOVE STAIR TREAD NOSINGS SHALL BE UNIFORM, NOT LESS THAN 34 INCHES AND NOT MORE THAN FRAMINGOO SEE OR 1" PLYWOOD <br /> 38 INCHES. •_ <br /> \ � \ STRUC, 00 STAIR TREAD <br /> 2. HANDRAILS SHALL RETURN TO A WALL, GUARD OR THE WALKING SURFACE OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN -f Y / �� Y �' <br /> ADJACENT STAIR FLIGHT. AT STAIRWAYS WHERE HANDRAILS ARE NOT CONTINUOUS BETWEEN FLIGHTS, THE HANDRAILS SHALL <br /> EXTEND HORIZONTALLY AT LEAST 12 INCHES BEYOND THE TOP RISER AND CONTINUE TO SLOPE FOR THE DEPTH OF ONE TREAD APPLY FIRE RESISTIVE JOINT <br /> BEYOND THE BOTTOM RISER. SYSTEM CONFORMING TO IBC SEE FLOOR PLAN SISTERED WHERE <br /> 707.5, ASTM E119 OR UL 293 AT FOR WALL TYPES SHOWN ON STRUCTURAL <br /> 3. HANDRAILS SHALL RETURN TO A WALL, GUARD OR THE WALKING SURFACE OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN '-'\ \" ALL GAPS AND PENETRATIONS z <br /> ADJACENT STAIR FLIGHT. , �� : -WALL ASSEMBLY PER FLOOR S T A I R T O P AT RATED SUPPORT WALL <br /> ;�� PLANS a <br /> NOSINGS (IBC 1009.4.5/ICC A117.1 504.5): THE RADIUS OF CURVATURE AT THE LEADING EDGE OF THE TREAD SHALL BE 1/2 INCH MAXIMUM. NOSINGS 4 <br /> THAT PROJECT BEYOND RISERS SHALL HAVE THE UNDERSIDE OF THE LEADING EDGE CURVED OR BEVELED. RISERS SHALL BE PERMITTED TO FIN. FLOOR ON GYPSUM TOPPING 1 1 / 2 " = 1 '-O" w <br /> SLOPE UNDER THE TREAD AT AN ANGLE OF 30 DEGREES MAXIMUM FROM VERTICAL. THE PERMITTED PROJECTION OF THE NOSING SHALL BE 1-1/2" <br /> MAXIMUM OVER THE TREAD OR FLOOR BELOW. THE LEADING 2" OF THE TREAD SHALL HAVE A VISUAL CONTRAST OF DARK-ON-LIGHT OR LIGHT-ON- <br /> DARK FROM THE REMAINDER OF THE TREAD. NOSINGS: IDENTIFY TREAD EDGE FOR FULL WIDTH OF STAIR TREAD. CONTRAST: CHANGE FLOOR I 3/8" PLYWOOD RISER (SLANTED) <br /> COLOR OR MATERIALS TO IDENTIFY STAIR LOCATION. PLYWD SUBFLOOR 11"TYP. 1" PLYWOOD TREAD LI <br /> ENCLOSURES UNDER STAIRWAYS (IBC 1009.6.3): THE WALLS AND SOFFITS WITHIN ENCLOSED USABLE SPACES UNDER ENCLOSED AND71' 2" CONTRASTING o <br /> UNENCLOSED STAIRWAYS SHALL BE PROTECTED BY 1-HOUR FIRE RESISTANCE CONSTRUCTION, OR FIRE RESISTANCE RATING OF STAIRWAY I JOIST HANGER-SEE STRUCTURAL VINYL STAIR NOSING- <br /> ENCLOSURE, WHICHEVER IS GREATER.ACCESS TO THE ENTRANCE USABLE SPACE SHALL NOT BE DIRECTLY FROM WITHIN THE STAIR ENCLOSURE. RIM JOIST-SEE STRUC. r SEE IFI <br /> LANDINGS (IBC 1009.5): THERE SHALL BE A LANDING AT THE TOP AND BOTTOM OF EACH STAIRWAY, THE WIDTH OF LANDINGS SHALL NOT BE LESS + <br /> 1"NOSING TYP. BLOCKING/NAILER <br /> THEN THE WIDTH OF STAIRWAYS THEY SERVE. EVERY LANDING SHALL HAVE A MINIMUM DIMENSION MEASURED IN THE DIRECTION OF TRAVEL 1' <br /> IIIltftlifl' STRUCTURAL <br /> EQUAL TO THE WIDTH OF THE STAIRWAY. SUCH DIMENSION NEED NOT EXCEED 48 INCHES WHERE THE STAIRWAY HAS A STRAIGHT RUN. DOORS ( CONNECTION <br /> OPENING ON TO THE LANDING SHALL NOT REDUCE THE LANDING TO LESS THAN ONE-HALF REQUIRED WIDTH. WHEN FULLY OPEN, DOORS SHALL BEAM -SEE STRUCTURAL <br /> NOT PROJECT MORE THAN 7" INTO LANDING. SIDES OF STAIRS. DESIGN AND FASTEN TO RESIST A MINIMUM FORCE OF 0.73 KN/Mt , <br /> \ DRAWN BY: KL <br /> (50 LBS./LF )AND A SINGLE CONCENTRATED FORCE OF 0.89 KN (200 LBS.)APPLIED <br /> IN ANY DIRECTION. :( GYPCRETE AT FLR LEVEL <br /> „�, :,, .,,, LANDING ONLY-SEE CHECK: LJ <br /> ROOF ACCESS (IBC 1009.13): IN BUILDINGS FOUR OR MORE STORIES ABOVE GRADE PLANE, ONE STAIRWAY SHALL EXTEND TO THE ROOF, UNLESS = I . ° - . _- FLOOR ASSEMBLIES <br /> THE ROOF HAS A SLOPE STEEPER THAN 4:12. <br /> � / --�,. / <br /> DISCHARGE IDENTIFICATION (IBC 1022.7): A STAIRWAY IN AN EXIT ENCLOSURE SHALL NOT CONTINUE BELOW THE LEVEL OF EXIT DISCHARGE - NOTES: <br /> UNLESS AN APPROVED BARRIER IS PROVIDED AT THE LEVEL OF EXIT DISCHARGE TO PREVENT PERSONS FROM UNINTENTIONALLY CONTINUING - IINTO LEVELS BELOW. DIRECTIONAL EXIT SIGNS SHALL BE PROVIDED AS SPECIFIED IN SECTION 1011. FLOOR FRQAMING AT G STOR I ENCLOSURE41110i/a2X6 <br /> I PLOT DATE: 7r20/20171:15:31 PM <br /> TACTILE EXIT SIGNS (IBC 1011.3/ICC A117.1 504.9): THE EXIT DOOR DISCHARGING TO THE OUTSIDE OR TO THE LEVEL OF EXIT DISCHARGE SHALL 7 %Mr <br /> JOB NO:HAVE A TACTILE SIGN STATING"EXIT." <br /> 1 1 / 2 = 1 0 �. 5/8"TYPE X' B 5215 <br /> FLOOR IDENTIFICATION SIGNS (IBC 1022.8): A SIGN SHALL BE PROVIDED AT EACH FLOOR LANDING IN EXIT ENCLOSURES CONNECTING MORE THAN .- �� ��/- <br /> THREE STORIES DESIGNATING THE FLOOR LEVEL, THE TERMINUS OF THE TOP AND BOTTOM OF THE EXIT ENCLOSURE AND THE IDENTIFICATION OF <br /> THE STAIR. THE SIGNAGE SHALL ALSO STATE THE STORY OF AND THE DIRECTION TO, THE EXIT DISCHARGE WHETHER THERE IS ROOF ACCESS <br /> FROM THE ENCLOSURE FOR THE FIRE DEPARTMENT AND WHETHER THE ROOF ACCESS IS ACCESSED BY ROOF HATCH,THE SIGN SHALL BE <br /> ..• <br /> LOCATED 5 FEET ABOVE THE FLOOR LANDING IN A POSITION THAT IS READILY VISIBLE WHEN DOORS ARE IN OPEN AND CLOSED POSITION. FLOOR y \ *I": ` <br /> LEVEL IDENTIFICATION SIGNS IN TACTILE CHARACTERS COMPLYING WITH ICC A117.1 SHALL BE LOCATED AT EACH FLOOR LEVEL LANDING ADJACENT WALL ASSEMBLY PER FLOOR PLANS �; <br /> TO THE DOOR LEADING FROM THE ENCLOSURE INTO THE CORRIDOR TO IDENTIFY THE FLOOR LEVEL. SEE DETAIL 4 THIS SHEET FOR SIGNAGE �= STAIR BOTTOM AT LANDING <br /> REQUIREMENTS PER IBC 1022.8.1. 1x12 KICKBOARD (OR 3/4"MDF) 0 s <br /> GUARD &RAIL ASSEMBLY: } a <br /> 1% GYPSUM TOPPING AT 4; ,h •, :. <br /> FINISH FLOORING ON •-•- .., i ,P.,,>;,,,.. <br /> PROVIDE GUARD AND RAIL ASSEMBLY PROTECTION AT THE ` r FLOOR LEVEL LANDING "- '-''k'in ••�'�- " '"" ^'�' <br /> FOLLOWING AREAS: ,>� !f WOOD TREAD.77,,z_sz9-1,)7.1E ,S SEE FIN. ONLY-SEE FLOOR Jensen/Fey 1 <br /> . . <br /> OPEN FLOORS&WALKWAYS: AT OPEN AREA LEVEL CHANGES TO PREVENT A <br /> 2x12 STAIR HEADER BEAM- I Architecture and Planning <br /> PERSON FROM ACCIDENTALLY STEPPING OR WALKING OFF THE UPPER FLOOR. STRINGER SEE I 7730 LEARY WAY NE <br /> -- §TfiUgTU A� <br /> DESIGN CRITERIA: PROVIDE FOR THE FOLLOWING. REDMOND, WA 98052 <br /> �. FIRE RETARDANT N TOR TEL:425.216.0320 FAX:425.216.0329 <br /> • HEIGHT: 107 CM (42 INCH) FLOOR LEVEL <br /> •OPENINGS: DESIGN TO RESTRICT THE PASSAGE OF A 10 CM (4 INCH) DIAMETER �- L. TREATED 2x6 LEDGER 2x6 REINF. �' '' °°°" ., -: - <br /> BALL. �\ FOR KICKBOARD SEE STRUC. ,-, , ,/ ///,;i'j ' 2, ;r /1 - <br /> • BOTTOM RAIL: 5 CM (2 INCH) MAXIMUM ABOVE FLOOR CARPET FINISH SEE IFI j <br /> • DESIGN TO RESTRICT CLIMBING. \ - 2"CONTRASTING VINYL <br /> • DESIGN AND FASTEN TO RESIST A MINIMUM FORCE OF 0.73 KN/M (50 LBS,/LF) /1101/2" SHIM AS REQ'D STAIR NOSING <br /> AND A SINGLE CONCENTRATED FORCE OF 0.89 KN (200 LBS.)APPLIED IN ANY • „ <br /> DIRECTION. �� , ���- <br /> • DESIGN INTERMEDIATE RAILS AND PANELS TO RESIST A HORIZONTAL LOAD OF 0.22 _ 5/8"TYPE'X'GWB _ -1/4" PLYWOOD RISER WITH <br /> KN (50 LBS.) PER 0.093 M2(1 SQ. FT.) ` CARPET FINISH <br /> ACCESSIBLE MEANS OF EGRESS (IBC 1007.3 LINE WITH SSTRINGERS ANDE �.1:' 2x6 FIREBLOCKING <br /> LANDINGS STUDSN LONG AND IN VIP o /� \\ N- CO <br /> 1, INTERIOR EXIT STAIRWAYS ARE ONE COMPONENT FOR THE ACCESSIBLE MEANS OF EGRESS FROM LEVELS ABOVE AND BELOW GRADE. , •- . <br /> A. THE 48" CLEAR WIDTH BETWEEN HANDRAILS REQUIREMENT IS NOT REQUIRED IN SPRINKLERED BUILDINGS (SBC 1007.3, EXCEPTION 2). 4111‘10: <br /> / / ' CV <br /> B. THE AREA OF REFUGE REQUIREMENT IS NOT REQUIRED IN SPRINKLERED BUILDINGS. V -5/4"TREAD PLANK OR 1" CO <br /> C. ACCESSIBLE STAIRS SHALL COMPLY W/ICC A117.1 SEC. 50. \ STAIR STRINGER A T RATED WALL LANDING FRAMING SEE STRUC. ... PLYWOOD STAIR TREAD W <br /> 2. ENCLOSURES REQUIRED (IBC 1022): INTERIOR EXIT STAIRWAYS SHALL BE ENCLOSED WITH 2 HOUR FIRE BARRIERS. EXTERIOR WALLS SHALL 6 t <br /> BE RATED AS REQUIRED FOR EXTERIOR WALLS. REFER TO SHEET A0.8A FOR FIRE RATED ASSEMBLIES. 1 1 / 2 " = 1 '-0 " 2X BLOCKING/NAILER <br /> 3. PENETRATIONS (IBC 1022.4): REFER TO SHEET A0.6 FOR REQUIREMENTS. 5/8"GWB 1.1.- <br /> 4. LIGHTING (ICC A117.1 -504.8): LIGHTING SHALL BE CAPABLE OF PROVIDING 10 FOOT-CANDLES (108 LUX)OF LUMINANCE MEASURED AT THE 2X6 SISTERED VVHERE O (- <br /> CENTER OF THE TREAD SURFACE AND ON LANDING SURFACES WITHIN 24" OF NOSINGS. REFER TO ELECTRICAL PLANS. PROVIDE GENERAL SHOWN ON STRUCTURAL a III <br /> 18" MIN. CLR FLR SPACE ILLUMINATION TO IDENTIFY STAIRS. I <br /> CENTERED ON TACTILE 1' -0" I Q LU <br /> CHARACTERS i SEE 18/A452 FOR > <br /> 4" TRIM & CAP DETAIL -- STAIR TOP AT LANDING J W <br /> 1-1/2"-2" DIAMETER WOOD OR METAL 2 <br /> 1/2" -' 3� _ 1/2" 1. STAIRWAY IDENTIFICATION -APPROVED y y - " <br /> i �- HANDRAIL-SEE STAIR PLANS SHEETS e\/,,,,/./ 1 1 / 2 - 1 -0 I--- �J <br /> NT t / " STAIRWAY IDENTIFICATION SIGNS SHALL BE I so FOR REQUIRED EXTENSIONS BEYOND � <br /> FABRICATED AND LOCATED PER IBC 1022.9. r TOP AND BOTTOM RISERS, SEE ALSO W CO <br /> THESE SIGNS SHALL BE MAINTAINED IN AN T _ _ GENERAL STAIR FLAG NOTE#3/A450 FOR (� <br /> - - APPROVED MANNER. ADDITIONAL REQ'TS._ .,._ /1 1l2"r.' 2" CONTRASTING VINYL STAIR CARPET FINISH -SEE IFI Q > J <br /> m . --co <br /> )c 1 T 2. SIGN SIZE-MINIMUM 18"x 12" _,__ <br /> ROOF ACC 1 "CLEAR t� REF SPEC & IFI FOR TYPE 2X STRINGER <br /> - 3. LETTER SIZES: Z <br /> �� + .• . . 3/8" PLYWOOD RISER WITH J <br /> • •• s STAIRWAY IDENTIFICATION 1 1/2" MIN „�;, „ <br /> ``' •� _ LETTERING w h= CARPET FINISH a- C) 0 <br /> FLOOR LEVEL DISIGNATION -5"MIN LETTERING C ':` , r <br /> \ I ALL OTHER LETTERING 1" MIN LETTERING - �, r; <br /> d N 5!4"TREAD PLANK OR 1" b ,- Z UJ <br /> z PLYWOOD STAIR TREAD > <br /> NOTES: ;' T F N <br /> 1, 4"WIDE x 3' HIGH x 1/8"THICK SIGN MOUNTED _ <br /> AT STRIKE SIDE OF EXIT DOORS. 2 ''- w P.T. 2X4'THRUST BLOCK' CO `c� U) <br /> �- -J �"i w/GALV . ANCHOR BOLTSV . NOTCH <br /> 2. LETTER CHARACTERS TO BE RAISED 1/32"x Q _ d 11" MIN. < - --- <br /> 7/8" HIGH UPPER CASE, SAN SERIF TYPE AND �, �, <t \I STRINGER AT <br /> N „. <br /> N BLOCK <br /> ACCOMPANIED BY GRADE 2 ROUNDED OR I2x6 SOLID �t FINISH FLOOR GWB <br /> DOMED SHAPED BRILLE. r - BLOCKING 9 F EET: <br /> 3. BRAILLED CHARACTERS TO CONFORM WITH - �� � ° . - <br /> EXIT LEVEL <br /> "w, A A <br /> STANDARD DIMENSIONS FOR LITERARY (9 = ° ' <br /> BRAILLE AND AS INDICATED IN ADA i TOP OF TREAD `- - •- ° A .CON'CRE°TE'SLAB; . , . <br /> GUIDELINES A4.30,4. BRAILLE FLOOR NUMBER a OR LANDING tP " ` I) A 4 <br /> .• <br /> ° • - : . , PAR FLOOR PLAN` .. ; <br /> 4. LOCATE SIGN AT EACH REQUIRED EXTERIOR BRAILLE STAIR ACCESS LEVELS • • •' •• -.- <br /> EXIT <br /> DOOR, (EXTERIOR DOORS WITH ,� TYPICAL CONDITION SEE SECTIONS FOR CONDITION ° <br /> ILLUMINATED EXIT SIGN ABOVE.) BRAILLE STAIR EXIT LEVEL ' ' - •' ''; ' '• _ <br /> TACTILE EXIT SIGN STAIR SIGNAGE HANDRAIL DETAIL STAIR BOTTOM 1 <br /> r -9 \ c.,_3) <br /> (5) <br /> Q <br />