Laserfiche WebLink
-- <br /> IF THESE SHEETS ARE NOT 24"X 36"THEN DRAWING IS NOT TO SCALE. <br /> r- <br /> r y <br /> (----- i <br /> GYPCRETE © <br /> FB PLYWOOD SHEATHING <br /> WOOD FRAMING PER STRUCT. <br /> I-JOIST PER STRUCT , <br /> GYPCRETE <br /> \ / <br /> _ Kw; <br /> / \ <br /> FC10 .A ' -/// ' ///./ /// !" /// /A./ //./ /./// /'/ <br /> . / PLYWOOD SHEATHING <br /> = <br /> CNI <br /> 1,-- <br /> .., , , ,, _, . , <br /> „ . ,.„ , .. , , _ • _ _ z.-------. <br /> , . -- . •• • • .. ,- • , , •, <br /> c,-, ,--- <br /> rz:r <br /> / \ i <br /> 1 — <br /> cs, <br /> co' <br /> rs- . <br /> co' <br /> to <br /> 7-- EU) <br /> 3"GLASS \ <br /> FIBER INSULATION TYPE"X"GYPSUM BOARD <br /> RESILIENT CHANNEL -- <br /> 2 LAYERS GWB <br /> SOUND <br /> 'NSW_ <br /> < <br /> '7. 0 <br /> 06 <br /> co <br /> 1--- <br /> (GWB LAYERS MAY BE APPLIED AT C (GWB LAYERS MAY BE APPLIED AT 0 <br /> I- <br /> a. z <br /> w <br /> 2 <br /> E /- 0 <br /> TIME OF FUTURE TENANT <br /> (_ TIME OF FUTURE TENANT (-) ....- (..)(I) c? <br /> IMPROVEMENT) IMPROVEMENT) LU ... <br /> FLOOR TYPE: C SECOND FLOOR --- a - <br /> c) <br /> \ FLOOR TYPE: B 16" JOISTS © SECOND FLOOR <br /> FLR TYPE FIRE RATING RATING# STC RATING COMMENTS f--- <br /> _. 1..... <br /> FLR TYPE FIRE RATING RATING# STC RATING COMMENTS <br /> FC12 1 HOUR GA FC 5116 STC 50-54 2X12 SEE STRUCT <br /> <FC10 1 HOUR GA FC 5116 STC 50-54 2X10 SEE STRUCT <br /> F-B 1 HOUR GA FC 5408 STC 35-39 SEE STRUCT a - --- <br /> (.0 <br /> - -c-r---) <br /> FC06 1 HOUR GA FC 5116 STC 50-54 2X6 SEE STRUCT <br /> r GA FILE NO.FC 5116 I PROPRIETARY' 1 HOUR 50 to 54 SIC <br /> I (2 ,-- <br /> FIRE SOUND GA FILE NO.FC 5408 GENERIC 1 HOUR 35 to 39 STC <br /> I < <br /> WOOD JOISTS,GYPSUM WALLBOARD,RESILIENT CHANNELS, <br /> GLASS FIBER INSULATION FIRE SOUND 1 2 <br /> .--,„' '2,,.:..!...„ , 1-J WO-00 TRUSSES,GYPSUM WALLBOARD 1 1 <br /> one ii-lyer me proprietary typo X gypsum emetic/4rd or gypsum veneer base applied at nght FS---i----7 : . . :- ----c----1 <br /> Base layer sie"type X gypsum wallboard limbed at right angles to parallel chord wood 5,i,--,-,,,,,,_ <br /> angles to resikent furring channels 24"rec.with 1"'Type S drgwall St.leWs,12 q.0 t- • . ti . - - - - 1.1 - -, <br /> Gypsum hoard end joests located maletay between continuous channels and attached to d' <br /> r1, I. trusses 24"Q.C.with 104"Type W or S drywall screws 24*o.c.Face layer 5/a"type X /----1' I-------------4 ri <br /> ,ir I, <br /> gypEILIF31 VJatboand or gypsum veneer bass applied at right angles lo ausSes with Pre i-/-----m--.., <br /> atrition&pieces of channel 54*long wen screws at 12'o.c.Resillent haring channels I <br /> Type W or S drforall ,C.10.`",i 12"oe.fit joints and intennethate trusses and Ith"Type G -..,_ ,, / --" -.4 DRAWN BY: Author <br /> applied at right angies kJ 2 x 10 wood icrirs,ts 16"me.with I Ire Typo W dryvrad screws. , .,, ,. .. ____, ,,.,,„, ..1 ,. is ,.,_.,,-` <br /> dry.vfill StfetV6 12'me,placed 2'back on either side of midi-rine-5,Juinic-offset 24"from i:- e <br /> Wood joists supporting 511"intro/on 1.k.F.NLIod WIth edema'glue striatum'and if perrne- E--'"-""=-'il '''''''""'"— —"L' ."*" "' '1 K <br /> sand huarache reinforced wan No, 19 SWG galvanized hexagonal?ma mesh.3"glass base layerjoints.Trusses suppoong Ile wo,Qd tltruatIrat parlaS applied al right angIes ,-----------4 )-------------c <br /> Lber insulation 0,90 pot in joist space,stapled to subtler-Jr, Apprna Ceiling to busses out,8,1 rials.Ceiling provides one hour fire resistance protettion tot b----------,---________-,i <br /> CHECK: <br /> trusses. Checker <br /> Weight; 2 psf <br /> PROPRIETARY GYPSUM BOARD Approx.Ceiling II <br /> Fire rest: UL T13453-7,5-140. <br /> American Gypsum Company LLC Ns"FirriBlociD Type C Weight 5 psf <br /> Based on UL R3660-7,-8. <br /> CurtainTood Gypsum Inc, - kre"CenainTeedr8 Type C Gypsum Board 11-12-87;R2717-61,8-16-07: Fine Test FM FC 172,2-25-72, <br /> ConainTeed Gypsum Canada Inc. - 4-re"CertainTeadii5 Type C Gypsum Board ITS 8-698 <br /> Based on UL R7094. . <br /> Georgra Parairt Gypsum LIC 513"roughRockil Fireguard Cie Sound Test Estimated <br /> 942N10186,15.1Q-24-96: <br /> Gypsum Board NOTES: <br /> Based WI UL R8742, <br /> Lafarge North Amenea Mc_ Its"Ftrecherik'D Type C 88E1822591,10-6,68; <br /> National Gypsum Company - 5/0"Gold Bondia Brand FIRE-SHIELD C'-' <br /> • UL Design L616 <br /> GYPisum Board Sound Test' KAL L 224-28-65,3-30-85 PLOT DATE: 7/200017 1:05:26 PM <br /> PASCO Gypsum . 51e"FLAME CURDie Super'C''''' IIC&Test: (74 C a p) <br /> Templeilnland lis"IC-C KAL L 224.27-65,3-30-65 C.I.P. CONCRETE <br /> i JOB NO: <br /> SAND BED i <br /> 1 5215 <br /> VAPOR BARRIER I <br /> RETARDER L <br /> , .. <br /> F-A 6" PEA GRAVEL AS WININNEEMESIM1MA <br /> \___ / CAPILARY BREAK mi:toi;i;:innimmengown. <br /> LAYER tIO•; <br /> .I. <br /> •.:;;.:,;; IJ I . <br /> ........ <br /> ....... <br /> ....... <br /> \ , ilt <br /> , •••ve <br /> 4 <br /> *V:: <br /> ....... <br /> ......, <br /> t:\I ., ,,. „., .•.. ,-• .-,o i,_s,..,_s. ,.,.„ •. , •, ,,. ‘. .• ,•s..,-.._ :ma <br /> ...... <br /> ...... ...4 <br /> 3 i i i,, ,- • • - --m, i,•- r. „.,. •. -*, ,- -•' 'r; <br /> rei. -_. " ' _am 7, a - 1- 11,111,1MMIEW <br /> _...,_...........,............,........"..,.................... <br /> A I I 1 <br /> ___ (---)_ c)__ c), >wc)_--- Jensen Fey <br /> - ----oc-ic-pc-DociDoci5-0 CD 0 _ - - <br /> I <br /> 1 Architecture and Planning <br /> • V Z--:( ZDnZ- <br /> K- ----) --)____:. <br /> ,--.2. _ <br /> (- <br /> ,-- <br /> 7730 LEARY WAY NE <br /> I <br /> IN- REDMOND, WA 98052 1 <br /> , \Ii TEL:425.216.0320 FAX:425.216.0329 <br /> i---= - ---='="------------ - <br /> COMPACTED NATIVE <br /> SOILS F— <br /> ILI <br /> FLOOR TYPE: A 4" SLAB ON GRADE 0) <br /> }-- <br /> FLR TYPE FIRE RATING RATING# STC RATING COMMENTS <br /> f F-A NR <br /> - - SEE STRUCT (i) <br /> (X) <br /> C) <br /> \I <br /> Co Ct <br /> Li] <br /> C 0_ Li <br /> _I <br /> CO <br /> __ -----v_ ----- <br /> LIJ <br /> CD <br /> -- ----V- .7- r___,7----- --- r___ , -----v_z------ ___7 •__ <br /> EPDM ROOFING MEMBRANE MIMS= co <br /> ? u_ rn , <br /> RIGID INSULATION-R38 RIGID INSULATION-R38 <br /> IGID INSULATION-R38 <br /> (SLOPE TO DRAIN) <br /> / PLYWOOD SHEA-THING/ RPLYWOOD <br /> / SHEATHING <br /> . „ 0 1--LI <br /> Z <br /> ----- 0 <br /> CL <br /> '•• VW *4t4 , <br /> =MOM LLI 0 <br /> At <br /> 1 4- <br /> co <br /> AA , . AA. '''./ e•, / ,-- <br /> Lil (1) <br /> t 7' <br /> \ <br /> )1/ 0 <br /> \ <> <br /> f t <br /> < > <br /> [>F< X 4 <> <br /> — LLI <br /> Z <br /> zo <br /> -6.- < <br /> .--I LIJ <br /> - TYPE "X"GYPSUM BOARD CI- 0) 1 <br /> TYPE"X" GYPSUM BOARD I f1 " . <br /> 0 <br /> ,-,_, WOOD FRAMING PER STRUCT. ' <br /> 1,-- .' < ' > C\I <br /> _ <br /> • <br /> \ RESILIENT CHANNEL\ 1 <br /> 1 NM= (0 <br /> ? , <br /> WOOD FRAMING PER STRUCTURE '--I r F—: <br /> ROOF TYPE: C EPDM ROOF ROOF TYPE: D EPDM ROOF AT ELEVATOR <br /> ROOF TYPE FIRE RATING RATING# A71 STC RATING COMMENTS ROOF TYPE FIRE RATING RATING# STC RATING COMMENTS _- <br /> R-C NR . SEE STRUCT R-D NR - - SEE STRUCT <br /> --- --- -- .._ .„2----k._ „, ,,_/"---) <br />