Laserfiche WebLink
IF THESE SHEETS ARE NOT 24"X 36"THEN DRAWING IS NOT TO SCALE. <br /> O <br /> LIGHTING FIXTURE SCHEDULE = w A. (_ <br /> o <br /> SYMBOL LEGEND GENERAL NOTES i , � v� , �� o • <br /> LIGHTING FIXTURE SCHEDULE 1. NOT ALL CONDUIT AND CONDUCTORS FOR BRANCH CIRCUITS HAVE BEEN SHOWN. IT THE RESPONSIBILITY' • N :1:157k <br /> / :��LIGHTING FIXTURES OF THE Ct�NTR4CT[}RSHALtIISTALtALLREQUIREDCflt3tllTdi�FDWIREFflRAC(}tdPll TEINSTAL3AATI4}IV. ,Or TYPE DESCRIPTION LAMPS MOUNTING MANUFACTURER UA —CU ci) 0 "� 'J <br /> 2. PROVIDE UhtSWTTCHED CIRCUIT F4R ALtEIIIT SI(xNS �i{d EORESS LIGHTIt�, UNLESS N4TEI}OTHERWIS�E. � � ,� . �T'$g�i� � <br /> 0 SURFACE OR PENDANT MOUNTED LIGHTING FIXTURE = '�t+`78TE�'' <br /> INDOOR 3. PROVIDE DEDICATED NEUTRAL FOR ALL BRANCH CIRCUITS. y . <br /> RECESSED MOUNTED LIGHTING FIXTURE _ ,z O' ` 'L <br /> '2' INDICATES CIRCUITING 4. MMIt1UM WIRE SIZES SHALL BE AS FOLOWS, UNLESS NOTED OTHERWISE: <br /> LITHO NIA AVL4-4OLSERIES OR c� -71 <br /> Fi LED STAIRWAY FT WITH INTEGRAL OCCUPANCY SENSOR LED WALL 40 2a „a„ INDICATES SWITCHLEG BRANCH CIRCUITS-#12Cu 1�, <br /> PHILIPS LAMB -CORRIDOR LIGHTING AND RECEPTACLE CIRCUITS-#111Cu <br /> -EXTERIOR BUILDING LIGHTING CIRCUIT'S -#1OCu '� <br /> I o I LINEAR STRIP LIGHTING FIXTURE i) r '0 » i 1 <br /> EXTERIOR SITE LIGHTING CIRCUITS-�ISCu ■i m O ! I <br /> F2 LED STRIPLIGHT 4 FT LED CHAIN HUNG PHILIPS FLUXSTREAM 25 I 2 1 WALL MOUNTED LINEAR LIGHTING FIXTURE 5. THE LIGHTING FIXTURES SPE CIFIE0 DO NOTSHOW ALL OF THE OPIT►ONS REQUIRED FOR Ir4STALLLATION. THE v in <br /> CONTRACTOR SHALL PROVIDE ALL REQUIRED MOUNTING EQUIPMENT, FLANGE KITS,SUPPORTS,PENDANTS, 0 I E <br /> Irtil LIGHTING FIXTURE, WITH INTEGRAL EMERGENCY ETC.REQUIRED FOR THE SPECEIC CELLINGTYPE ATNO.ADDITIONALCOST CONTRACTOR SHALL COORDINATE m Ch .,,� <br /> F2W LED ENCLOSED GASKETED WEATHERPROOF 4 FT STRIPLIGHT LED WALL PHILIPS OR APPROVED 25 BATTERY BACKUP, (MINIMUM 1150 LUMEN OUTPUT) AND VERIFY CEILNfi�TYPES AND MOUNTING CONDITIONS WITH ARCHTECTURAL PLANS. W '"� a a <br /> R. EXTERIOR LIGHTING SHALL BE CONTROLLED THROUGH BUILD NG UGHTING CONTROL SYSTEM. PROVIDE a -.1 ! • <br /> 0 RECESSED DOWNLIGHT FIXTURE <br /> SEPARATE ZONING FOR: BUILDING,SITE,AND SIGNAE, UNLESS NOTED OTHERW IE. PROVIDE LIGHTING <br /> — _ CONTACTORS AS REQUIRED. f !, . . <br /> Q DOWNLIGHT, WITH INTEGRAL EMERGENCY BATTERY BACKUP, Ni <br /> CAPRI CAMI#AIW 1172T L21,SW-BAL- <br /> F3 LED RESTROOM VANITY LED WALL 22 (MINIMUM 700 LUMEN OUTPUT) 7. COORDINATE EXACT DEVICE HEIGHTS AND LOCATIONS WITH FURNITURE LAYOUT AND ARCHITECTURAL <br /> UNV-35OCK-MA01 ELEVATIONS PRIOR TO ROUGH-IN. <br /> --' 0 SURFACE MOUNTED FIXTURE 1 i <br /> 8. COORDINATE EQUIPMENT REQUIREMENTS(LOCATION,CONNECTION TYPE,.CONTROLS,LOAD,VOLTAGE,ETC.) <br /> WITH SUPPLER PRIOR TO E QUIP MENT ORDERING AND ROUGH-IN. z ! I <br /> F4 LED RESTROOM DOWNLIGHT LED CEILING LITEPROFILE#P4R-15OOL-3500K 13 0 PENDANT MOUNTED FIXTURE O <br /> 9. PROVIDE ALL CONDUIT AND 124V CONTROL WIRING FOR EQUIPMENT,INCLUDING,BUT NOT LMITED TO. HVAC aa.. <br /> OUTDOOR 10 WALL MOUNTED LIGHTING FIXTURE SYSTEMS,GARAGE CO SENSORS.THERMOSTATS,ETC. E2cn <br /> 10. VERIFY EQUIPM€NTCONNE CTION'tYPE (RECEPTACLE OR HARD-WIRED CONTE CTION)WITH EQUIPMENT W <br /> (EXIT) EXIT SIGN, -- INDICATES DIRECTION OF ARROW SUPPLER,PRIOR TO ROUGH4N,AND PROVIDE RE QUIRED RECEPTACLE OR CONNECTION. 0 { l E I ! I <br /> P1 LED POLE LIGHT-ONE HEAD LED POLE GARDCO#ECF SERIES 105 <br /> � <br /> 8270 LUMENS MC I. COMBINATION EXIT SIGN/EMERGENCY LIGHTING UNIT 12. PROVIDE CONNECTIONS FROM FRE SPRINKLER P.I.V.,FLOW SWITCHES AND TAMPER SWITCHES TO FIRE { <br /> ALARM SYSTEM, COORDINATE EXACT LOCATIONS AND QUANNTITY REQUIRED WITH GENERALCONTRAC.TOR. w I ( <br /> EMERGENCY LIGHTING UNIT Q <br /> 13. UTILITY CO.COORDINATION: CONTRACTOR IS RESPONSIBLE FOR INCOMING SERVICESTO BUILDING(POWER, o I i i <br /> P2 LED POLE LIGHT-TWO HEADS LED POLE GARDCO#ECF SERIES 210 TELEPHONE,FSER OPTIC CABLE,AND CABLE TV). THIS INCLUDES, BUT IS NOT LIMITED TO,COORDINATION <br /> 10828 LUMENS Ifl EXTERIOR WALL MOUNTED LIGHTING FIXTURE AND SCHEDULING WITH UTILITY COMPANES,VAULTS,TRENCHING,CONDUIT, HANOHOLE S, PU LLB O)E S, ETC. I <br /> EMERGENCY _ AS REQUIRED BY SERVING UTILITIES. ! <br /> [}-a POLE MOUNTED AREA LIGHTING FIXTURE 14. PROVIDE LIGHTING CONTROLS TO MEET OR EXCEED WSEC. CONTROLS SHALL INCLUDE, BUT ARE NOT LIMITED TO: cfC <br /> < ( 1 <br /> COMBINATION LED EXIT SIGN/EMERGENCY LIGHTING UNIT, CONTROL PANEL-SHALL PROVIDE TIMED CONTROLS TO TURN OFF ALL LIGHTING,WHICH IS NOT CONTROLLED ( I I <br /> X WHITE THERMOPLASTIC HOUSING WITH GREEN LETTERING, LED WALL/CEILING LITHONIA QUANTUM LHQM SERIES 3 BOLLARD BY OCCUPANCY SENSOR, DURING UNOCCUPED HOURS. PROVIDE WITH ALL NECESSARY RELAYS, <br /> Tim ECLOCK. 2HOUR OVERRIDE AND WIRING FOR ACOM'PLETE OPERABLE SYSTEM. <br /> UNIVERSAL MOUNT,90-MINUTE BATTERY BACKUP LIG-TING CONTROLS OCCUPANCY SENSORS-PROVIDE CEILING OR WALL MOUNTED OCCUPANCY SENSORS,IN LOCATIONS SHOWN DRAWN BY: KLH 1 <br /> ON DRAWINGS. ALL OCCUPANCY SENSORS SHALL BE PROVIDED WITH MANUAL ON/AUTOMATIC OFF, <br /> VACANCY SENSOR CAP ABILITES. CHECK: BB <br /> NOTES: 1. THE FIXTURES SPECIFIED DO NOT SHOW ALL OF THE OPTIONS REQUIRED FOR INSTALLATION. THE CONTRACTOR SHALL PROVIDE DAYLIGHT SENSORS-PROVIDE DAYLIGHT SENSORS TO AUTOMATICALLY DIA LIGHT FIXTURE s IN DAYLIGHT ZONES. <br /> ALL REQUIRED MOUNTING EQUIPMENT, FLANGE KITS, SUPPORTS, PENDANTS, ETC. REQUIRED FOR THE SPECIFIC CEILING TYPE a SINGLE POLE SWITCH - o INDICATES SWITCHLEG DAYLIGHT SENSORS SHALL BE CAPABLE OF DIMMING 0-10IVDC BALLAST/DRIVERS AND SHALL BE <br /> AND/OR SURFACE AT NO ADDITIONAL COST. CONTRACTOR SHALL COORDINATE AND VERIFY CEILING TYPES AND MOUNTING $3 THREE WAY SWITCH COMPATIBLE WM-I LOCAL DIMMING CONTROLS.. PROVI?E WITH ALL ADJUSTMENT CONTROLS . <br /> CONDITIONS WITH ARCHITECTURAL CEILING PLANS. COMMISSIONING-THE LIGHTING CONTROL SYSTEM SHALL BE COMMISSIONED BY A THIRD PARTY <br /> COMMISSIONING AGENCY TO CONFIRM ALL COMPONENTS ARE AS DESIGNED. NOTES: <br /> 2. CONTRACTOR SHALL PROVIDE DIMMABLE BALLAST FOR ALL LIGHT FIXTURES IN THE DAYLIGHTING ZONE(S), NO ADDITIONAL COST. FOUR WAY SWITCH <br /> 3. ALL LED LAMPS SHALL BE 3500°K UNLESS NOTED OTHERWISE. PLOT DATE: 3/20/2017 2 47 58 PM <br /> 4. FINISHES ARE TO BE SELECTED BY ARCHITECT. <br /> D DIMMING LIGHTING CONTROL SYSTEM SWITCH (0-10V DC) <br /> JOB NO: <br /> 7 WALL MOUNTED OCCUPANCY SENSOR, SEE 17016 <br /> LIGHTING/PLUG-LOAD CONTROL DIAGRAM, SHEET - <br /> ELECTRICAL ABBREVIATIONS - <br /> oc CEILING MOUNTED OCCUPANCY SENSOR, SEE <br /> LIGHTING/PLUG-LOAD CONTROL DIAGRAM, SHEET A or AMP AMPERE LTG LIGHTING <br /> Ps CEILING MOUNTED PHOTO SENSOR, SEE A/E ARCHITECT AND ENGINEER <br /> AFF ABOVE FINISHED FLOOR MCB MAIN CIRCUIT BREAKERJ f , <br /> LIGHTING/PLUG-LOAD CONTROL DIAGRAM, SHEET AFG ABOVE FINISHED GRADE MCC MOTOR CONTROL CENTER <br /> LOW VOLTAGE COMMUNICATIONS AIC AVAILABLE INTERUPTING MDP MAIN DISTRIBUTION PANEL <br /> CURRENT MLO MAIN LUGS ONLY <br /> AHU AIR HANDLING UNIT MTD MOUNTED <br /> AL <br /> ♦ WALL MOUNTED TELEPHONE OUTLET - PROVIDE BACKBOX AND AC ABOVENUM COUNTER NC NORMALLY CLOSED Jensen Fey <br /> STUB 3/4"C. UP TO ACCESSIBLE CEILING SPACE <br /> NEC NATIONAL ELECTRICAL CODE Architecture and Planning <br /> C CONDUIT NEMA NATIONAL ELECTRICAL 7730 LEARY WAY NE <br /> V WALL MOUNTED DATA OUTLET - PROVIDE BACKBOX AND CFL COMPACT FLUORESCENT MANUFACTURER'S ASSOCIATION REDMOND,WA 98052 <br /> STUB 3/4"C. UP TO ACCESSIBLE CEILING SPACE CKT CIRCUIT <br /> NIC NOT IN CONTRACT TEL:425.216.0320 FAX:425.216.0329 I', <br /> 'Jr COMBINATION DATA/TELEPHONE OUTLET - PROVIDE BACKBOX CLG CEILING NO NORMALLY OPEN <br /> AND STUB 3/4"C. UP TO ACCESSIBLE CEILING SPACE CONN CONNECTION <br /> CU COPPER OH OVERHEAD <br /> POWER OS OCCUPANCY SENSOR ' <br /> DISC DISCONNECT PH PHASE <br /> CE DUPLEX RECEPTACLE EMT ELECTRIC METALLIC TUBING PNL PANEL <br /> PVC POLYVINYL CHLORIDE <br /> 0- DOUBLE DUPLEX RECEPTACLE F FUSE <br /> FA FIRE ALARM I CO <br /> Cr DUPLEX RECEPTACLE, MOUNTED ABOVE COUNTER AT FLA FULL LOAD AMPERES TEL TELEPHONE O <br /> +44" UNLESS NOTED OTHERWISE. TYP TYPICAL N <br /> CO <br /> GFCI or GFI GROUND FAULT CIRCUIT <br /> Et DUPLEX RECEPTACLE, GFCI TYPE INTERRUPTER UG UNDERGROUND W 0) <br /> GND or GRND GROUND V VOLT U < <br /> it DUPLEX RECEPTACLE, GFCI TYPE, ABOVE COUNTER GRS GALVANIZED RIGID STEEL VA VOLT AMPERES _ <br /> OO JUNCTION BOX HP HORSEPOWER W WATT I I"'- <br /> HTR HEATER WP WEATHERPROOF O <br /> 'O' MOTOR CONNECTION HZ HERTZ <br /> W/0 WITHOUT <br /> INC INCANDESCENT Z 11 <br /> Aso/ao DISCONNECT SWITCH OR COMBINATION MOTOR XFMR TRANSFORMER Q W <br /> STARTER/ DISCONNECT SWITCH. SWITCH SHALL INCLUDE JB or J-BOX JUNCTION BOX J Lu <br /> ALL REQUIRED CONNECTIONS. (60) INDICATES SWITCH 0 or PH PHASE W <br /> AMPERAGE/ (40) INDICATES FUSE AMPERAGE. KV KILOVOLT ' Q <br /> KVA KILOVOLT AMPERES (E) EXISTING F— W <br /> $M MANUAL MOTOR STARTER, WITH THERMAL OVERLOAD KW KILOWATT UJ U) <br /> KCMIL THOUSAND CIRCULAR MIL (N) NEW W <br /> Air.- CIRCUIT HOMERUN - MIN 3/4"C-2#12 PLUS #12GND N , Q > I"' <br /> UNLESS NOTED OTHERWISE. r N Q W <br /> Q W <br /> ro CONDUIT CONCEALED IN WALLS OR CEILING. ",Cs J I- 1 <br /> I O 6) <br /> IS <br /> CONDUIT UNDER FLOOR OR UNDERGROUND. <br /> 0 CONDUIT UP NI s > N <br /> D CONDUIT DOWN SHEET INDEX - o 0 <br /> I-- u) U <br /> L. <br /> u i 208/120V PANELBOARD W <br /> w <br /> E000 COVER SHEET <br /> CALL OUTS E100 ELECTRICAL SITE PLANEl <br /> oa <br /> SHEET: <br /> Z D DETAIL NOTE E200 FIRST & SECOND FLOOR - ELECTRICAL PLAN v J <br /> W <br /> ® LIGHTING FIXTURE TYPE. SEE FIXTURE SCHEDULE. E300 ELECTRICAL ONE-LINE & PANEL SCHEDULE �y <br /> alaLI_ E000 <br /> Z. <br /> T O <br /> r� <br /> 00 <br /> >o <br /> iii <br /> <o <br /> l,W <br />