Laserfiche WebLink
PROVIDE"L"CASING BEAD AT <br /> , Ph : - OUTSIDE LAYER OF v <br /> • G.WB., TYP. . PROVIDE"L"CASING BEAD AT <br /> OUTSIDE LAYER OF <br /> • • CAULK JOINT BETWEEN CASING G.W.B., TYP. �11 <br /> ` ` <br /> BEAD AND COLUMN, TYP. S' CAULK JOINT BETWEEN CASING BEAD CONCRETE COLUMN • �� ``� <br /> � ��% AND COLUMN, TYP. °a <br /> SPRAY URETHANE ° I� <br /> INSULATION .o - ° TYPICAL WALL /-�" I, <br /> a °, °�: CONCRETE COLUMN PER <br /> ° p° °°• - INTERIOR GYPSUM BOARD �_�� �I I PROVIDE"L"CASING BEAD AT <br /> CONCRETE COLUMN PER °'" °°. -WALL FRAMING PER STRUCTURAL W/ ,�__� r +• CONCRETE COLUMN OUTSIDE LAYER OF <br /> PLAN-CHAMFER EDGES `_�� G.W.B., TYP. • <br /> a �° ,• < =4- a •:a_ PLAN-CHAMFER EDGES EXPOSED CORNERS WITH a e GATT INSULATION :did <br /> • • EXPOSED CORNERS WITH °° 3/4"CHAMFER STRIPS, TYP. a a° EXTERIOR SHEATHING PER WALL SCEDULE °, - <br /> ° ° <br /> 3/4"CHAMFER STRIPS, TYP. ° a •° "111.11111.11111111.1.1111 DUPONT TYVEK WRAP <br /> ° - = MAINTAIN CONCRETE WALL PER ° a- ° <br /> = ° :$ a• , e L:::: :::: <br /> ULATION AT METAL FRAMING <br /> PROVIDE"L"CASING BEAD AT ., o- ° ° + . jp RECOMMENDED <br /> °'b ° : ° R CLADDING PER ELEVATIONADJACENT TO LI FASTENER SPACING FRAMED WALL WITH 3/4" a-• ;IW <br /> • <br /> 'I BACK SUFFICIENTLY TO ALLOW BEAD i q • ^" -• a• • <br /> TO REMAIN RECESSED/FLUSH WITH 4-, 010._ .., ��—�� ° NDED • a <br /> • FACE OF CONCRETE COLUMN � FASTENER SPACING <br /> S PROVIDE"L"CASING BEAD AT <br /> OUTSIDE LAYER OF NOTE: •-" <br /> 11101P.-• WALL TYPE PER PLAN G.W.B. TYP. SET WALL FRAMING NOTE: • o MECHANICALLY FASTEN DUPONT TYVEK TO <br /> . TO41111WP � MECHANICALLY FASTEN DUPONT TYVEK TO_ BACK SUFFICIENTLY TO ALLOW BEAD CONCRETE COLUMN IF NECESSARY TO °<9 <br /> REMAIN RECESSED/FLUSH WITH CONCRETE COLUMN IF NECESSARY TO ° <br /> SO" <br /> MAINTAIN RECOMMENDED FASTENER • <br /> :+. MAINTAIN RECOMMENDED FASTENER <br /> � FACE OF CONCRETE COLUMN SPACING ; SPACING <br /> WALL TYPE PER PLAN <br /> NOTE ; PROVIDE ACOUSTICAL SEALANT • <br /> AT PERIMETER EDGES OF ALL FRAMED WALLS <br /> AND AT PANEL EDGES PRIOR TO TAPE <br /> OConcrete Column @ Party Wall 2 Concrete Column Transition O 1 1ncrete1To0�Drywall @ Elevator <br /> 1 1/2 1 -0 1 0 <br /> HALLWAY FASTENERS 24"0/C <br /> USG J-RUNNER OPR E-STUD l_�� INIIIMEMIIIIIIIIIIIIIIIIIIMIN1111111 Wall <br /> SOLID BLOCKING AT - <br /> WALL/SHAFTWALL INTERSECTION SHAFT WALL STAGGER GWB ry� <br /> / SEAMS AS REQUIRED WrapR/0 (All Sides) �,Wil 1 7,1,1„ <br /> Per Plan <br /> ,l 11 Lap WRB Over Drip Flashing <br /> * , /{ „ / w/(1) Layer Type X GWB Permit Set <br /> " Tape and Mud Seams --- - <br /> ;� It \ p 1 hr Rated Ceiling �' ® 1 i - Drip Flashing at Head <br /> a Blocking as Req. Metal or Wood �.�NLIPISIP i Match Color of Vent B 1804-011 <br /> / / c cn _\ rI•- fe Soffit Framing _� I1*- 1oil. . _ Fy-y <br /> ������ �1_ . . . ��._ �� I� Vent Flush with Face of Siding <br /> • • -, - - - m d WpTr" <br /> >®I■m f . I <br /> Duct. . Insect Screen <br /> 6"CHSTUDS a 4� L �� 11.-as - , /I ' • .11+� ' � I',� ���.� • Sealant at All Sides REGISTERED <br /> INTERIOR UNIT SHAFT <br /> - Continue GWB up . - - ARCHITECT <br /> -� <br /> Wall and Fire AM.�. Wili <br /> ` No.8013,y- <br /> Fire Extinguisher Cabinet Caulk Around Duct �%f j�cam/Spray Foam Insulation <br /> iki- <br /> . 26GA Interior Unit Ducting • p Y Joshua S.Scott <br /> Opening Per Manuf- kinip 0%10 Around Penetration STATE of wasHiNGTON <br /> Fire Extinguisher Cabinet in 1 hr Rated <br /> ® Shaft Framing Detail @ Wall Intersection ® Assembly 0 Exterior Vent @ Brick O Brick vent <br /> 1 1/2" = 1'-0 1 1/2" = 1'-0" 1" = 1'-0" 1 1/2" = 1'-0" <br /> illn <br /> ommosi minim i imum uurn ' <br /> ■■■■■■■■■■■■■■■■■■■■■■i TECHNICAL <br /> • err�' <br /> ■■■■■■■■■■■■■■■■■■■■■■1 <br /> - l�■■■■■■■■■■■■■■NI <br /> :.:.:... : ::::::::<:::25 MODEL # DHEB-64L- <br /> E <br /> N Designed for finished exterior systems such as <br /> 2x6 Corridor Ceiling Q VENTILATION SYSTEMS Metal 'ltn■l Compression Fit. <br /> lhr Rated Ceiling IY1111 <br /> !i� lI� <br /> FRONT�t� y g TOP VIEW REAR Vt1 E'W <br /> 1114;) <br /> 14� 12 8 5" <br /> �� 411. <br /> i C\I SHAFT , <br /> '' _ tPERPLAN/ �'�s�s <br /> ': !,� ` MEP I .�® .'' r n g <br /> Loh <br /> 11111 Ito, <br /> 1 <br /> 1��4. �� HALLWAY ‘,:,Fit ...., :‘,:_,, <br /> ,,_; + _� h 6 la <br /> IIIIV !t <br /> 1 minami mum <br /> I�� FIRE CAULK AT SEAM Illrq ? : L. 1.4iii <br /> =." LIVING UNITIIIIIIIIIIIEll IIMIIMI <br /> �+. �aDDID NIP . ' 110 <br /> l- �Ls. ' t i <br /> . SOLID BLOCKING ATup <br /> ' <br /> c �� I <br /> USG J RUNNER 20GA , L <br /> * # DATE DESCRIPTION <br /> c <br /> . SHAFT PERIMETER + <br /> l <br /> �' CONT. 1 3/4"LSL RIM PER _ „; ;` aA `,.� -:. v 1 ; . « <br /> u. j�, STRUCTURAL DETAILS HANGER AS REQUIRED - <br /> u_ i �� NNN,krik <br /> -, UNIT UNIT r 'w" �.1 .,5"' 4.� `� ,, _. __..0 0 Unit 1► Hallway Unit ° o :. - ' J :; <br /> 12.125" 1r Cliii) <br /> SECI ,Ai_�ViIMS <br /> � � I E .,.... . ...,.,��....................... »>v2l,)n �S�}SSSSSSSSSS SSS�SSSSSSSSSSSSSSfSSSS555S5SSSSSSSSSSSSSSSSSSSSSS • <br /> g �� >SSSSSSSSSSSS4SSSSS�S SSSS SSSSSSSSSS SS�SSSSSSSSSSSSSSSSSSSSS; <br /> � -, o �� � -; y • , DEVELOPMENT <br /> d °D co j Q ; Draftstopping <br /> F Imo: : o \ Blocking at 1hr 1830 SIU T OROD AVE, <br /> - i�' ` ►- Wall Partitions tin- <br /> j�� o `c ; „ = L.L. = l ' i SNOHOMISH, WA 98290 <br /> ��'"^ �„ r,l 206.755.1290 <br /> id <br /> I�� �: Plenum0•0000000000 , <br /> (Sy !. <br /> SOLID BLOCKING %', <br /> AT SHAFT LOCATIONS �'11 ' � Li 311.-Lailr <br /> ' '�`" r North Broadway <br /> > - <br /> oNA <br /> MIPwilla <br /> 1020 Everett WA 98403 <br /> I�� WA r <br /> CONT. WALL AZIN% Oil g! A.i TOP PLATES ��• — TJI FLOOR JOIST J s,. <br /> :. _____.__________________________________._____ •: ' . PER STRUCTURALiiiiiiii <br /> rillOpir <br /> ' USG J RUNNER 20GA1111111°I11111 <br /> 111111 lk Via%II <br /> FIRE CAULK AT SEAM -'41111111II II LIVING UNIT �• '* t' SHAFT AND FRAMING DETAILS <br /> • 'I , UNIT UNIT <br /> II <br /> ti �i <br /> ;t tr+ <br /> HALLWAY 4 <br /> MODEL D EB"6 L- ill, DATE: Issue Date <br /> ® Typical Hallway Wood Framing ® Shaft Framing @ Floor/Ceiling 10 DRAFT STOPPING @ 1 HR PARTITIONS _ <br /> 1/2" = 1'-0" 1 1/2" = 1'-0" 1 1/2" = 1'-0" <br /> SHEET: <br /> A6 . 03 <br />