Laserfiche WebLink
WINDOW SCHEDULE -GENERAL NOTES <br /> 1.)TrV= Trickle Vent(Vents shall comply with reach ranges of the current ADA Accessibility Code) <br /> Vinyl Window Schedule 2.) Operable windows shall be installed with hardware limiting the opening to prevent passage of a <br /> Color: White ` 4" sphere, OR The window may be provided with fall prevention devices complying with ASTM F <br /> Type: VPI Endurance or Approved Equal; Refer to Specifications for Additional Information 2090. <br /> 3.) Safety glazing shall be installed per IBC Ch 24 tables 2406.2(1) and 2406.2(2) <br /> 4.) On all operable windows; Controls shall be located within accessibility reach range 15"to 48" <br /> 7' - 0" 7' -0" 4'-0" AFF. <br /> -/ — / A / / 5.)Trickle Vent hood or vent weather protection (If Applicable) shall be provided and installed prior <br /> 3 0" 1, 4' 0" 4' 0" I, 3'-0" to window installation. Hoods shall be set(embed) in sealant. <br /> 6.)All new fenestration shall be NFRC 100 tested, certified and labeled: per 2015 Washington State <br /> \ \ _______, ' \ \ \ \ Energy Code 303.1.3. <br /> / N7.)All glazing shall have a required max. SHGC 0.30 as required by 2015 Washington State Energy <br /> / N Code C402.4. <br /> / N <br /> o N o o 8.)All fenestration products will be installed per the manufacturers installation instructutions, and <br /> _ > will be provided to the building official at the time of weatherization inspection. <br /> 'ID co o in o i1 <br /> I ; WATER PENETRATION RESISTANCE FIELD TESTING <br /> TrV Try o w The following testing will be performed on the building at the owner's expense and separate contract <br /> > TrV with testing agency. The contractor shall make the site ready for testing per the following protocol. <br /> 4\ N\ ' �\ N\ �\ N\ N- J <br /> I-- EXTERIOR VIEW EXTERIOR VIEW h EXTERIOR VIEW e'.) INTERIOR VIEW At least 1 window of each type will be tested per the following specified field test pressures in ., . <br /> m accordance with the current version of ASTM E 1105. <br /> _:-\ ;-\ ;-.\ \ <br /> 6.0 psf for storefronts <br /> Type A (Left) Type AA (Right) Type B Type A (Left) <br /> 6.0 psf for swing doors <br /> — 6.0 psf for windows and sliding doors <br /> These pressures should be placed on the purchase order prior to ordering the windows • <br /> and doors. <br /> WINDOW SCHEDULE <br /> Procedure B (cyclic)test will be used for 4 cycles each 5 minutes in duration, with to pressure <br /> FRAME reduced to 0 psf for 1 minute between cycles. For storefront, Procedure A(uniform)test will be <br /> TYPE HEIGHT WIDTH COUNT MANUFACTURER MODEL MATERIAL FINISH COLOR U-FACTOR(MAX.) NOTES used for a single cycle not less than 20 minutes in duration. The initial test will be inclusive of both <br /> A 6'-0" 8'-0" 56 VPI Quality Windows 511 Series-Endurance Vinyl Paint White 0.26 installation interface and window product. In the case of failure(devined in ASTM 1105), the <br /> AA 6'-0" 8'-0" 68 VPI Quality Windows 511 Series Endurance Vinyl Paint White 0.26 representative sample will be expanded to five (5) specimens in order to obtain statistical <br /> conficence in remedial repairs if needed. In the case of failure, the responsible party will be held <br /> B 6'-0" 8' 0" 28 VPI Quality Windows 511 Series-Endurance Vinyl Paint White 0.26 financially liable for the cost of retesting, and any related wall assembly or cladding deconstruction <br /> Grand total: 152 needed to obtain passing results. The test specification supercedes AAMA Voluntery Specification <br /> for Field Testing. The test results will be reviewed by the Architect. <br /> Note: Per IBC 2406.4 Hazardous Locations: Safety glazing is required in operable <br /> panels and storefront windows adjacent to doors (Typ.). <br /> �--- SILL REINFORCEMENT <br /> INSTALL IN FRAMES LARGER <br /> 'llia t THAN 40SF OR SILLS 95"AND - <br /> LARGER <br /> I <br /> 3 4 11..__TYP. TYP. <br /> 3 4 ;==:Eli I <br /> - - — \- —Subfloor Wood Framed <br /> A7.03 A7.03 <br /> r..........r......L..... ...m.....=.v.....I <br /> IIIIATLIIIII <br /> • ,1 _3_,, <br /> swam <br /> Permit Set <br /> / / \ 'ir\ ( B 1804-011 <br /> k <br /> 6__.,,,iprOpq <br /> Arli11011—i <br /> 7� WINDOW CORNER DETAIL III A CIHI EE <br /> A7.03 12" = 1 -0, CT <br /> 5 <br /> P. N <br /> / No.8013 <br /> I Joshua S.Scott <br /> o I <br /> '� STATE OF WASHINGTON <br /> _/ Freik A.;419N <br /> o O c) <br /> I,- .. ,, <br /> >, o <br /> i / `�4 I I ir.,d...i...E _ <br /> i r 7i. (i.`�`1;I- <br /> ( 7.0 .. • <br /> 3 lip, _ <br /> 6 <br /> -\ \ \ \ <br /> L IIE] <br /> r• , ,z^ <br /> EXTERIOR INTERIOR '- -incia� r-1--1irh III <br /> -N- — \ Subfloor Wood Framed I )1 , <br /> ire: F - 1 <br /> ,ituL. <br /> J,, �'TLT--1 <br /> -f <br /> INTERIOR VIEW I ` EXTERIOR ILIUM Li INTERIOR EXTERIOR MIM _�� INTERIOR <br /> TYP I AI <br /> I A7.04 <br /> A7.04 # DATE DESCRIPTION <br /> k =am <br /> O TYP. WINDOW HEADER / SILL HEIGHTS WINDOW SECTION A O WINDOW SECTION B <br /> 3/4 = 1 -0 6 = 1 -0 6 = 1 -0 <br /> DEVELOPMENT <br /> 1830 BICKFORD AVE, <br /> SUITE 201 " <br /> SNOHOMISH, WA 98290 ' <br /> / 0'-3" I 0'- 3 5/8" / 0'-3 1/4" 206.755.1290 <br /> 0'-2 5/8" / 0'_3" 0' 2 7/8" <br /> c !IIIIIM,v.--.7—s, <br /> \ _ � I /���tr� <br /> Co D M � i ,c I _, 1.111 fl <br /> I r1020 North Broadway <br /> 0 t,_ i:v —_ 1/.12, --1 <br /> ' ilt Everett, WA 98403 <br /> Til <br /> 1 <br /> jr <br /> I 1 i i <br /> 40-- - ;---- <br /> i I o iv 1 ( i ( I .rm�� i i i 3o �iI / / ���� Q �► We / / WINDOW SCHEDULE& DETAILS <br /> 1 D , , , ( 'r-)IQ7 ZL��� l �—J,7 Dr,�.��ll iu i,-, <br /> I <br /> J;I� 0'-5 7/8" 0'- 1 1/8" <br /> 0'-57/8" / / <br /> / / DATE: Issue Date <br /> SHEET: <br /> O <br /> WINDOW SECTION C © W6 WINDOW SECTION D A7 ■ ®4 <br /> 6 - 1 0 <br />