General Note: Provide skirt boards on all interior stairs- Paint to match <br /> Stair Shaft Side wall. <br /> 2hr Shaft Wall <br /> Mu■■ RETURN HANDRAIL TO WALL PER SEE DETAIL <br /> gi 2hr Wall <br /> �---- Gyperete Topping at <br /> Face of wall 1 ' 'e Floor Levels �.1 1/2". <br /> between flights �� Hallway Interior Stair Shaft Side �� <br /> a Stair Landing <br /> _ _ _ Intermediate Stair Landing ` I 1-1/2" DIA. METAL TUBE HANDRAIL, <br /> I ■■■■■■■■■■■I" lk. =V. . <br /> ss�<"� �s�sssssjsss�ss� sssss�sscss�ss s s ssssssssssssss4ssss s ssstssssssssssKsssssisss ssssss�sss�ss _ _ PAINTED. <br /> : : <br /> Ah LedgerTO CENTEROFSkirtboard - I ; t! c <br /> Exterior/ -- HANDRAIL- 36 COVER PLATE <br /> EAD"b �Screw into each , i kr ' , <br /> and bottom to match CC WI , i co , <br /> height of baseTOMMENNEEMMEE Stud illii Hallway Joist Per Plan x I - o:= :=:I; <br /> _dig <br /> 400e <br /> i �� 1/2" DIA, HANDRAIL SUPPORT, PAINTED i �� <br /> Stair Stringer(typ.) • Solid Blocking at Stair Shaft Side, „ . iiiimmismimodnimminimm liti <br /> �� 5/16" 1-1/2" DIA. METAL TUBE <br /> I. Stair/Shaft floors. Typ. (2) Layers GWB behind Ledger - \ 2" DIAMETER METAL MOUNTING HANDRAIL, PAINTED. • <br /> Conc. Floor Slab per Q • 4 ° �' If prerock is installed prior to - PLATE, SECURE MOUNTING HEIGHT PER PLAN <br /> °' framingDensglass maybe - Igr4 \ WITH #12 SCREWS <br /> Structural Drawings ;° 9 - (1) Layer 5/8"GWB on Stair Shaft Side g (4) <br /> ` " Underside of Stringer used ; Overlap seams - \N— <br /> • ° GWB <br /> - : ` d"°° • °;-a r CONT. BACKING: 600S162-54 AT LOWER LEVELS <br /> Hallway Interior 009 - 2hr Wall (a. Stair Landing Ledger _T WOOD BLOCKING AT ALL OTHER LEVELS. <br /> _________-- (1) Layer 5/8" GWB on 2hr Wall <br /> on furring strips <br /> - - STAIR RISER HEIGHTS SHALL BE 7 INCHES MAX. AND 4 INCHES MIN. THE RISER HEIGHT <br /> SHALL BE MEASURED VERTICALLY BETWEEN THE NOSINGS OF ADJACENT TREADS. <br /> RECTANGULAR TREAD DEPTHS SHALL BE 11 INCHES MIN. MEASURED HORIZONTALLY <br /> BETWEEN THE VERTICAL PLANES OF THE FOREMOST PROJECTION OF ADJACENT <br /> GWB Soffit- Confirm Final TREADS AND AT A RIGHT ANGLE TO THE TREAD'S NOSING. <br /> Height AFF with RCP 007 - Bottom of Wood Stair 00. Concrete Floor 008 - 2hr Interior Wall n. Corridor Floor Level <br /> 12" MIN. / THE RADIUS OF CURVATURE AT THE LEADING EDGE OF THE TREAD SHALL BE NOT <br /> / <br /> GREATER THAN 9/16 INCH. BEVELING OF NOSINGS SHALL NOT EXCEED 9/16 INCH. <br /> Sprinkler line to be located RISERS SHALL BE SOLID AND VERTICAL OR SLOPED UNDER THE TREAD ABOVE FROM <br /> above Finish GWB - THE UNDERSIDE OF THE NOSING ABOVE AT AN ANGLE NOT MORE THAN 30 DEGREES <br /> ROM THE VERTICAL. <br /> (1) Layer GWB behind Ledger THE LEADING EDGE (NOSINGS) OF TREADS SHALL PROJECT NOT MORE THAN 1-1/4 <br /> Ifprerock is installed prior to HANDRAIL HEIGHT'7, ) <br /> INCHES BEYOND THE TREAD BELOW. <br /> Face of wall <br /> between flights framing Densglass may be Exterior 1 hr Wall NOT LESS <br /> I I I I ) used ; Overlap seams ----__ ___ THAN THAN 34 INCHES4' MAX. <br /> AND NOT HANDRAILS SHALL RETURN TO A WALL, GUARD OR THE WALKING SURFACE OR SHALL <br /> I14-1401MORE THAN 38 BE CONTINUOUS TO THE HANDRAIL OF AN ADJACENT STAIR FLIGHT. WHERE ' <br /> LSSUI Hanger at ea Stringer Stair Shaft Side INCHES HANDRAILS ARE NOT CONTINUOUS BETWEEN FLIGHTS, THE HANDRAILS SHALL <br /> D <br /> Face of wall between Intermediate Stair Landing __,__\ r 'N HORIZONTALLYATLEAST12INCHESBEYONDTHETOPRISERANDCONTINUETO • <br /> flights I I I I I ) --- SLOPE <br /> Attach Ledger to 1 FOR THE DEPTH OF ONE TREAD BEYOND THE BOTTOM RISER. THE EXTENSIONS OF • <br /> � HANDRAILS SHALL BE IN THE SAME DIRECTION OF THE STAIR FLIGHTS. <br /> Stair Tread I �, o I w/Fasteners Length Exterior ���P Permit Set <br /> Designed to account <br /> ---- Flight of stairs going UP for Gypsum B 1 80 11 <br /> 9 g 9 ��tuzu �a�z�uz��uuzx��z� Yp ��� <br /> beyond wall 2x8 Landing Joist 3 1/4"x3.5" SDS01Note: The where possible anchors shall be cast- Y - g O 1104 <br /> STAIRWAYS PERMITTED TO BE CONSTRUCTED OF WOOD ABOVE <br /> in place with 1/2"x6" steel bent anchor bolts ,, I • Screw into each Stud <br /> THE HORIZONTAL ASSEMBLY <br /> C' ° Stair Shaft Side ARE ALSO PERMITTED TO BE CONSTRUCTED OF WOOD BELOW <br /> 1/2"x 6" expansion bolts w/ 0'-3 5/8" 1'-0 3/4" <� a a <br /> washers - (6) total at rim board typ. /1 / A Edge of P.T. slab supporting UP - 641k <br /> THE HORZIZONTAL ASSEMBLY. <br /> N flight beyond, typ. �, Ir Ail <br /> - <br /> / REGISTERED <br /> Weyerhauser SturdiStep OSB Stair : '",G a e - O STAIR DETAIL <br /> I< . �\ r' \ Tread, or equal, set in subfloor adhesive ° 3" __ 1, 0„ ARCHITECT <br /> " f 1 : \ 0'- 11° a a tr 006 - 1 hr Exterior Wall a(7 Stair Landing Ledger N 8013 <br /> 7:1 <br /> -. La o\ v ° ' ° Conc. WallBeyondI STATE <br /> C OF WASHINGTON <br /> Joshua S.Scott <br /> Conc. Floor Slab per Structural = - I I I \ _ ° d •°a , HUC Concealed-Flange Hanger <br /> Drawings $ 0'-0 1/2" •,` _ ° - (Not Shown)Attached to Concrete / Wall / <br /> ' 3/4" OSB Wall Beyond to Support Beam. <br /> GWB Soffit- Confirm Final I Assembly r _ - _ <br /> Height AFF with RCP --- __ 1 1 <br /> \l\ 1 I I I I I I I I 005 - Landing Support aC� Conc. Wall J Wood Levels __ I ( - -------- -_ - <br /> . . Weyerhauser TimberStrand A! <br /> X- <br /> 414 LSL 11 7/8" Stair Stringers, or " 008 - -� 1 /\ <br /> 1.75"Weyerhauser TimberStrand LSLPir equal, 12"o.c. I - - - <br /> L <br /> 14" Rim Board at head of stairs I �" <br /> I 5/8"Type'X' GWB where exposed I ° ' <br /> below <br /> THAI Hanger I <br /> Note: Top ends may be cut where they I I Stair Shaft Side • <br /> a '- li" Exterior <br /> extend beyond the top of the ledger i <br /> Saw Curf or Seat Cut Stringer I I Face of Wall Between Flights '- A <br /> �� Refer to Finish Plans for a _ - , -Finish <br /> 7/7/ <br /> ' ' <br /> - 006/ ' <br /> ,� 0' 2 1/8" Conc. Wall Per a ` ( (- <br /> 4' / Nosing sawn from Structural Drawings <br /> SturdiStep OSB Stair Tread i I I 009 <br /> • <br /> 004 -Top of Wood Stair(c Concrete Floor L I I 3/4" OSB Sheathing <br /> IL — <br /> 2x8 joists @ 16" o.c. a ( <br /> . <br /> ( II I - hµ:-��1�� � v Simpson LU28 Face „a _ -, <br /> Mount Joist Hanger -- --- a IF - -- . '.... :• - ,� - , <br /> ALL LSL'S TO BE 1 3/4"WIDTH MIN. Skirtboard Refer to Finish `' T <br /> I <br /> 5/8"Type'X' GWB = • <br /> where exposed below -:- °-. :,,,;,. I ` <br /> ( IIIIIII I ' ." Conc. Levels — — — — — — I— — # DATE DESCRIPTION <br /> ° I I 1 (_ CRIP <br /> =d < . ' I I I I <br /> 2x8 treated ledger, bolted to — I I <br /> concrete wall with (2) 1/2" b . a I I I O , <br /> C I I I I I expansion bolts @ 32" o.c. typ. 004/ - <br /> 7 <br /> op.,. <br /> Weyerhauser TimberStrand LSL 007 I , I i DEVELOPMENT <br /> \ 3 1/2"x 14" beam, typ. at landings <br /> L— ,,- — — 1830 BICKFORD AVE, <br /> IIIII LSSUI Hanger at each stringer I I SUITE 201 . <br /> 003 -Wood Framing (@, Conc. Wall I I SNOHOMISH, WA 98290 <br /> II <br /> r - - , I I 206.755.1290 <br /> I <br /> Nosing shall have a <br /> 0' 11" I I Weyerhauser TimberStrand <br /> curvature or bevel of I)r ? , <br /> LSL 11 7/8'Stair Stringers, or <br /> Where anchors are required in P.T. not less than 1/16" - equal, 12"o.c. I I— — 003 <br /> Slabs ALL holes drilled for anchor but not more than J ( I ( (1) Layer GWB Typ. at \�i I I 1020 North Broadway <br /> bolts into floor slabs must have the 9/16"from the 0'-0 1/2" I , I /, . <br /> priorforemost projection Underside of Stair stringers " I I Everett,WA 98403 <br /> area x-rayed wll to installation to p j Single-layer ceiling assemby: 5/8"Gypsum Panels applied to I �i�` <br /> verify anchors will not hit a tendon. of the tread support members and fastened with 1-5/8"Type W screws — L <br /> \ ( IIIIIIII spaced @ 12" o.c. located a min. 1-1/2"from side/end joints. I - I— — 002/ <br /> -- 3/4" OSB c - - rr- J 005 <br /> WOOD STAIR DETAILS <br /> Skirtboard -- ti - Weyerhauser 002 -Wood Framing 0, Landing <br /> v SturdiStep OSB Stair <br /> Rubber Base- Refer to Tread, or equal, set in <br /> Finish Plans -\-__ I I I I I I I l I I subfloor adhesive r —r _ 11 - <br /> --- - Weyerhauser TimberStrand 001 - -I i <br /> DATE: <br /> LSL 11 7/8" Stair Stringers, I I Issue Date <br /> \ or equal, 12" o.c. I I <br /> Let-in treated 2x4 nailer w/ L - - - - J <br /> (3) 1/2" dia., 3" long anchor bolts - SHEET: <br /> 001 -Stair Base AEI . 01 <br /> O WOOD STAIR DETAILS O <br /> Generic Stair Section <br /> • <br /> - 1 1/2" = 1'-0" .. <br />