Laserfiche WebLink
t <br /> r 1 <br /> • <br /> 2'-11 1/8" CON �O <br /> •' <br /> Hoistway Venting 2'-s 1/8" <br /> The elevator hoistway shall be provided with a means for venting smoke 4'-4" <br /> ir <br /> and hot gases to the outer air in case of fire. Venting shall be sized per ' _1 • • _, Z., <br /> fil <br /> WA state amendment 3009 under a seperate mechanical permit. The 'DUCT COMM <br /> • <br /> °9 oaooaoaooaolula000aoou 0000Ioaa0000u000000u0000ua000000o aR °f oa000aeu000000uoai00000 IMooaoaoou00000uoEMoouoaoa 1 <br /> total required vent area shall be equipped with dampers that remain - <br /> powered closed until activated open by the fire alarm system panel. The 7' <br /> dampers shall open upon loss of power. L J <br /> V 0 ° <br /> General Note: pop E� °o°°°° 6 <br /> L_i - Q z v S <br /> 0 COVER ap -I ` SYNERGY CONTROLLER ASSY SYNERGY CONTROLLER SYNERGYLERASSY <br /> 1. Central Control Point Communication Location Shall be < S o "°°L�' `°°°`�g' <br /> Approved by the Fire Department. Equipment is 0 `O ° .,- <br /> of ° <br /> M <br /> Assumed to be Located at the Recall Level Level 2 B - (FRONT) _ 1 I- b• o <br /> I I J I I l I I I I I 1 I ! Residential Entry Lobby. 7 v E aeoue00000000a00000000o u000�0000au000000000aou000au0000ao 3 ooaoAuu000u000uoouooaoo 00000u0000000000u00000000000uORN ] <br /> 1 2. Basement Level is Accessible to Grade-2-Way �, ° ° <br /> Communication is Not Required. w . "' •- ` - :' r <br /> 3. Provide Elevator Pit as Required by Elevator Company 0 DISCONNECT SWITCH,ABOVE CAR io -,_ ` 6 <br /> - - <br /> Pit Shall Have 4 Walls Refer to Structural Design for r LIGHT AND ALARM CIRCUIT WITH HEAT <br /> SEPARATE CISCONNECT SWITCH - DEFLECTOR - cn <br /> Additional Information. Pit ladder required with rungs to 48" above to (STACKED) <br /> ° BY OTHERS <br /> AND DISCONNECTS bottom of door sill. EA) COn 1 " Emergency switch is located a min. of 36"- N c_ N <br /> 48" max. above bottom landing. r BOLT PATTERN FOR <br /> d I Provide light/switch adjacent to pit and GFCI L__ L ZO WALL MOUNTED CONTROLLER <br /> - _ I T.O. Parapet 4 convenience recptacle. a " • • " • • <br /> 176' - 6" J <br /> p ,,/ - 1- 4'-0"CLR.OPNG. <br /> M I ° 'I 1 4'-4" MAX DIMENSIONS FOR DISCONNECTS <br /> I Lj ROOF Primary Recall Level- LEVEL 1 ._ 10 3/4" 7 g/16" <br /> '- 2 " 1 73' - 6" WALL MOUNTED CONTROLLER <br /> -I • <br /> i • <br /> o m <br /> , \ <br /> co 0 I <br /> G.C. General Note: Q° o <br /> Solid Blocking at 1 <br /> o5 - Floor Levels Typ. - II <br /> cal 1. Coordinate installation requirements with 1 - <br /> elevator contractor. Provisions forguardingLOCATION IS <br /> (1)RACEWAYS REQUIRED 6"WIDE X 6"HIGH ELECTRICAL <br /> Verify l t © . 100 amp DISCONNECT 60 amp DISCONNECT <br /> Clearance c� and protecting the hoistway during ELEVATOR GENERAL NOTES: DETERMINED BY RELATIONSHIP BETWEEN <br /> CONTROLLER CLOSET AND HOISTWAY. SQUARE D DISCONNECTS OR EQUIVILENT <br /> W/ Elevator � � construction shall be erected, maintained, FINAL LOCATION TO BE VERIFIED WITH • <br /> Manuf. ' and removed by other than the elevator ELEVATOR INSTALLATION AND SIGNAGE SHALL CONFORM TO ALL FINAL LOCATION <br /> FIELDO SUPERINTENDENT. DISCONNECT SWITCH(BY OTHERS) <br /> a) contractor. All safety barricades shall be <1- 1 <br /> B APPLICABLE CODES. TEMPERATURE RANGE(32°F MIN.,104°F MAX.) <br /> outside of the elevator hoistway as required. 0� <br /> ELEVATOR EQUIPMENT AND CONTROLLER ROOMS (AS REQUIRED) SHALL BE 10%-95%NON-CONDENSING RELATIVE HUMIDITY <br /> OF SUFFICIENT SIZE TO ACCOMMODATE ALL RELATED EQUIPMENT AND 7'-6"MIN.CEILING HEIGHT <br /> MAINTAIN WORKING CLEARANCES. THE MINIMUM SIZES SHOWN FOR THESE CONTROL SPACES ARE PREDICATED ON AVERAGE <br /> SIZED COMPONENTS AND ANY OVERSIZED BOX OR DISCONNECT <br /> \ \ ELEVATOR-LEVEL 1 COULD AFFECT THE SIZE OF THE CONTROL ROOM. <br /> Level 5 O "STAR OF LIFE" SYMBOL TO BE LOCATED ON HOISTWAY FRAME. SYMBOL <br /> 2 1/4" = , „ *DISCONNECTS LARGER THAN THESE DIMENSIONS SUCH AS AN ELEVATOR SHUNT <br /> VI <br /> A II <br /> 163' - 6" 1 -0 SHALL BE MIN. 3" MIN. IN HEIGHT. - SHUNT TRIP CENTER COULD INCREASE MINIMUM CONTROL ROOM DIMS. <br /> AN APPROVED PICTORIAL SIGN OF A STANDARDIZED DESIGN SHALL BE <br /> POSTED ADJACENT TO EACH ELEVATOR CALL STATION ON ALL FLOORS <br /> O INSTRUCTING OCCUPANTS TO USE THE EXIT STAIRWAYS AND NOT TO USE <br /> O THE ELEVATORS IN CASE OF FIRE. THE SIGN SHALL READ: IN CASE OF FIRE, } <br /> ELEVATORS ARE OUT OF SERVICE. USE EXIT STAIRS. * PREFERABLY THE CONTROL CLOSET SHOULD BE LOCATED AT THE TOP LANDING Permit Set <br /> AND THE MAX DIST.OF CONDUIT RUN FROM CONTROLLER TO MACHINE IS 150'. <br /> o PROVIDE A DEDICATED OUTSIDE TELEPHONE LINE TO THE ELEVATOR B 1804-011 <br /> `-' z / CONTROLLER FOR MONITORING; <br /> `t / B NOTE:AT ELEVATOR LANDINGS A TWO-WAY COMMUNICATION SYSTEM SHALL THIS STANDARD ARRANGEMENT IS TO BE USED WITH NO ADDITIONAL OPTIONS <br /> F0- �� BE PROVIDED AT THE ELEVATOR LANDING ON EACH ACCESSIBLE FLOOR AND A FEEDER VOLTAGE OF 208/240 OR 460/480 V <br /> THAT IS ONE OR MORE STORIES ABOVE OR BELOW THE STORY OF EXIT <br /> Ew+ DISCHARGE COMPLYING WITH SECTIONS 1009.8.1 AND 1009.8.2. <br /> Level 4 - 1009.8.1 SYSTEM REQUIREMENTS REGISTERED <br /> A153' - 6" TWO-WAY COMMUNICATION SYSTEMS SHALL PROVIDE COMMUNICATION ARCHITECT <br /> I , - I h BETWEEN EACH REQUIRED LOCATION AND THE FIRE COMMAND CENTER OR Nasols�- <br /> J � A CENTRAL CONTROL POINT LOCATION APPROVED BY THE FIRE CIo 80 3 <br /> •7 . .) _., <> DEPARTMENT. WHERE THE CENTRAL CONTROL POINT IS NOT CONSTANTLY <br /> / �� ATTENDED,A TWO-WAY COMMUNICATION SYSTEM SHALL HAVE A TIMED Joshua S.Scott <br /> ! <br /> AUTOMATIC TELEPHONE DIAL-OUT CAPABILITY TO A MONITORING LOCATION. STATE OF WASHINGTON <br /> ,. <br /> OO 7�1 7 I PER WA STATE AMENDMENT SECTION 1009.8.1 THE TWO-WAY <br /> i i i Elevator shall accomodate COMMUNICATION SYSTEM SHALL HAVE A BATTERY BACKUP OR AN <br /> , = © I- ( 7/ - the loading and transport of APPROVED ALTERNATE SOURCE OF POWER THAT IS CAPABLE OF 90 <br /> o Z \ an ambulance gurney or MINUTES USE UPON FAILURE OF THE NORMAL POWER SOURCE. <br /> U- stretcher(Max size 24"x84" <br /> O w/5" radius corners in the THE TWO-WAY COMMUNICATION SYSTEM SHALL INCLUDE BOTH AUDIBLE AND a <br /> - AA horizontal position) VISIBLE SIGNALS. Attachments for elevator rail support ° <br /> ---- 1009.8.2 DIRECTIONS. brackets shall be installed by the G.C. ' ° <br /> DIRECTIONS FOR THE USE OF THE TWO-WAY COMMUNICATION SYSTEM, Bracket location, spacing, and <br /> INSTRUCTIONS FOR SUMMONING ASSISTANCE VIA THE TWO-WAY connection points shall be per y s <br /> w Level 3 W2 COMMUNICATION SYSTEM AND WRITTEN IDENTIFICATION OF THE LOCATION FINAL ELEVATOR SHOP DRAWINGS <br /> Z �� SHALL BE POSTED ADJACENT TO THE TWO-WAY COMMUNICATION SYSTEM. Submitted by the elevator manuf. ° <br /> < A I( a A 143 - 6 B Final shop drawings shall be reviewed by , ` <br /> 1 co <br /> ELEVATOR SHAFT NOTE; NO PIPES, DUCTS, OR PLUMBING OTHER THAN the structural engineer for attachment points - . <br /> w I� THROUGH OR BE LOCATED WITHIN THE SHAFT OR MACHINE ROOM. loads as defined on the final shop drawings. <br /> 00 a , . <br /> J HOISTWAY VENTS AND/OR PRESSURIZATION AIR INTAKES AS REQUIRED BY d - ° 4' <br /> _ `r 1- o w WA ENERGY CODE TO HAVE DAMPERS- REFER TO BUILDING CODE 3016.5 ' <br /> Ho rn FOR VENTS AND SECTION 8.4 FOR DAMPER OPERATION REQUIREMENTS. . 4 . , <br /> 0 ,- _z 3 ELEVATOR-LEVEL 2-5 TYPICAL Steel plate cast into concrete wall a ,•4 ; <br /> 1- w 3 1/4" = 1' 0" ALL IMBEDS, CONNECTIONS, WELD PLATES, OR OTHER STRUCTURAL confirm detail with structural engineer <br /> i- ATTACHMENTS SHALL BE COORDINATED AND DESIGNED WITH ELEVATOR - • ` <br /> DESIGN/MANUF.AND STRUCUTRAL ENGINEER. ALL ATTACHMENTS MUST BE <br /> DESIGNED AND RATED FOR SEISMIC ZONE 3.Si 10"concrete wall- refer to plans a <br /> ELEVATOR EMERGENCY POWER IS REQUIRED BY IBC SECTION 1009.4. THE A. - • <br /> ' Level 2 1 B EMERGENCY POWER SHALL COMPLY WITH ALL OF THE REQUIREMENTS <br /> I, } 133' - 6" A8.04 CONTAINED IN IBC SECTION 3003,AND SHALL POWER ALL ELEMENTS OF THE ., <br /> _ _ ELEVATOR SYSTEM IDENTIFIED IN IBC SECTION 3007.8. • <br /> ° e THE FOLLOWING FEATURES SHALL BE SUPPLIED BY BOTH NORMAL POWER When bracket spacing does not work with <br /> AND TYPE 60/CLASS 2/LEVEL 1 STANDBY POWER. <br /> 1. ELEVATOR EQUIPMENT. floor to floor rim elevations assume <br /> ri.-° minimum (2) 51/2"x7'/2" LVL 2.0E (or PSL) • <br /> • 2. ELEVATOR HOISTWAY LIGHTING. per side with base and head attachment <br /> 3. VENTILATION AND COOLING EQUIPMENT FOR ELEVATOR MACHINE clips for bracket plate support. Final support <br /> _ _ ROOMS, CONTROL ROOMS AND SPACES. details TO BE VERIFIED BY THE FOR <br /> ° ° O Hoistbeam \' 4. ELEVATOR CAR LIGHTING. 2 09/01/19 Set II Rev 1 <br /> 0 , ° p"° ° -a # DATE DESCRIPTION <br /> e d <br /> ? __/______________ THE FOLLOWING SPECIFIC CODE PROVISIONS SHALL APPLY: Structural rim per plan I I 111111111& All I <br /> z - - ° WA State Amendment 909.21.13 Machine rooms. }� -I ll I� <br /> -IAE"�' 1.ASME Rule 2.2.2. Waterproof as necessary to prevent entry of ground water. Sump 1/4"x 2"x 2"Washer plate <br /> zo 2 <, ( Elevator machine rooms shall be pressurized in accordance �a !Ilk it <br /> c,- .z I ..`° , ,, " with this section unless separated from the hoistway shaft by O Elevator Overrun pumps may be installed for flood control but not approved to maintain a dry pit. I <br /> O tr construction in accordance with Section 707. 2.ASME Rule 2.7.5.2. Provide machine room and hoistway ventilation. Welded stud on plate j � <br /> ~ ° Note: Machine room is seperated by 2hr construction. 3.ASME Rule 2.7.4. Provide min. 7'-0' clear headroom in machine room. <br /> a 4.ASME Section 2.4 and 3.4. Provide proper top car runbys, clearances and refuge �I�' DEVELOPMENT <br /> " <br /> • > . . a, ,' space. <br /> IP <br /> Fire caulk all seams t <br /> - o°° ® Elevator Control Unit and Shut 5.ASME Rule 2.1.1.2 and 2.11.14. Grout all masonry jambs and headers to retain fire (yp) ( 1830 BICKFORD AVE, <br /> tin Off Layout and Equipment Per rating of hoistway. In other than masonry, provide labeled entrance assemblies installed <br /> a /� y Steel late for rail connection, set direct) III SUITE 201 <br /> ° E"` p y iiiiiii," SNOHOMISH, 01 98290 <br /> Elevator Shop Drawings as tested. against face of rim verify size, and <br /> 6. Ventilation and pressurization equipment, ducts, etc. cannot be located in elevator with elevator manuf. I 206.755.1290 <br /> 8 -8"� iv machine rooms, hoistways, or spaces. placementI ' <br /> • <br /> ` _ 3 i - - - `- - 3 7.ASME Rules 2.1.1.2 and 2.14.1.8 Glass used in or on elevator hoistways and cars Fire caulk all seams (typ.} <br /> �� - ELEV.CONTROL `r must be laminated and meet the requirements of ASME Z97.1 ; <br /> _ L_evel 1 a <br /> �- - - 117' - 6" RM. r` 8.ASME Section 2.6. Provide calculations to for approval of the ability of the pit floor 1 <br /> I I I ] Control Room Shall be Key 623 EM and structure to withstand the elevator buffer engagement reactions. <br /> 9. ASME 2.27.1. Provide means of two-way conversation between each elevator and a I <br /> Lockable, Reserved Exclusively for 018 64 SF 1020 North Broadway <br /> Provide Min. 18x18x18 SumpPit the Elevator Control Equipment. 10. ASME 2.27.1.1.2 This structure is considered as unattended, and an additional <br /> ' I Limy youm I <br /> r-\ \ emergency signaling devices shall beprovided (phone to answeringservice). Everett,WA 98403 <br /> in - MountedSteel Grate <br /> a readilyaccessible point(Main Elevator Lobby)outside the hoistway. 2hr wall assemblyrefer to plans <br /> w w/Flush 9 Y 9 9 ) <br /> -•• _ _ Coordinate Location w/Elev. Equipment. 11. ASME 2.27.1.1.5 Provide an emergency power supply for the devices required by <br /> • Provide a Single 12" 11=11 2.27.1 The supply shall be capable of operating the audible device for at least one hour <br /> \ L, Wide Tread 7" Deep and the means of a two-way conversation for at least four hours. ELEVATOR DETAILS <br /> Note: Provide Elevator Pit as Required Step down at Interior O 12.Install approved key retainer box, keyed to the secure city key. <br /> II III II III III II� by Elevator Company- Pit Shall Have 4 B 13.Keys required for the operation of elevator, fire emergency service, the machine <br /> Walls- Refer to Structural Design for room and the mechanical hoistway access key shall be tagged and kept in the key box. O ELEVATOR RAIL CONNECTION DETAIL <br /> Additional Information. 7 3" = 1'-0" <br /> All applicable ASME Codes, Building Codes, Electrical Codes and Elevator Codes <br /> 4O ELEVATOR CONTROL ROOM Adopted By Reference apply. Note that each Conveyance requires a separate permit DATE: Issue Date <br /> with detailed installation plans and shall be installed by a Washington State licensed <br /> 1/4" = 1'-0" <br /> elevator contractor. <br /> Elevator shall comply with accessibility requirements, notably section 407 in ICC A117.1 <br /> and ANSI A117.1 SHEET: <br /> 1 ELEVATOR A8. 04 <br /> 1/4 - 1 -0 <br />