• <br /> Ew, .. . <br /> BB O Plumbing Fixtures <br /> P-1 Maxwell 21-918- 1.28 ErgoHight Elongated Toilet <br /> ~—I' ----- P-2 Comfort Designs XSS 4878 SH NS 4.0 (Type B Unit <br /> Shower) <br /> I 001 P-2a Fiber Care Baths Inc. HES38-38BF T Size A(Type A <br /> O Unit Shower) <br /> . Removable Removable 6'-5 1/2" 2'- 11" 4'-2" P-3 Casework w/Integrated Top <br /> to O cabinet cabinet / / / _ Olympia L-6050 i2 Single Handle Lavatory Faucet(CP <br /> ® Finish) <br /> - —\ 111111M111111 o _ P-4 Kitchen Sink- Elkay ECTRU17179 SS Undermount <br /> Sink <br /> r ( r • o : REF Olympia K-5025 i2 Single Handle Kitchen Pull Down <br /> REF : I �� I I �- 0 6' 7 3/8 2'-6 1/8" 3'-9 1/2' 7 1/2" Faucet <br /> I „ I I 0 ao i' I 1 `� / — P-5 Fiber Care Baths Inc.ADA Shower Stall HES38-38BF T • <br /> 1'-6" I <br /> N ,/ —I - - - 1 —1- 1 I _ \ <br /> 6 /I I i I ,.,, I _ ` Casework <br /> A9.03 0 002 , i ` w T - 002 - o o =-) . c i- a �� I ,, - CW-1 Owner Provided/Installed Wardrobe <br /> O - • <br /> 1 r r -'-, - - - \ _ ,- --1�00 0 ,- I -- Studio CW-2 Owner Provided/Installed Bed Tower <br /> J r-F 1 Co 1 L - 1 - J _^__ 331 531 CW-3 Owner Provided/Installed Bed <br /> _{ I- _E GG v— J7 — T Removable 294 SF E,, / Misc Finish Items/Accessories <br /> _' _ 002 i i 1 I z 36"x22" Frameless Mirrror w/Spring Loaded Brackets <br /> _ cabinet o Symmons 353TP Dia Wall Mounted TP Holder <br /> \ L I L I _ 1 6 N 2'- 1" 5'-21/2" 2'-7" 3'-6" 2'-7" 3'-67/8" Y <br /> I (o - <br /> c) / / / I Symmons 353TB Dia 24"Towl Bar <br /> Electrical g 7/g I� - Electrical ;n 1 O i CO Symmons 352SH Dia Showerhead <br /> 2 - 1 4 -6 3/8 2 -8 5/8 3'-9 5/8 8 7/8" 3'-9 5/8 -8 5/8" 4' 7 7/8" 2'- it Electrical REF , - <br /> - 0 Electrical O <br /> power anel / Xa / / power <br /> power It. - power o <br /> Removable Moen SS Shower Rod <br /> p C panel panel \ panel - o cabinet <br /> Misc. Items <br /> o N 2'- 1" 4'-7" 6'- 101/2" \ <br /> \ - WH-1 King PAW 2022 Wall Heater <br /> Studio "' / /O , 0 - r Electric Thermostat ESP230-R Programmable <br /> - Studio N r - <br /> 3 , 301 501 O Studio 5 A9.03 4 :CA] 8 I A9.02 6 Co HWM Meter Technology Werks MTW MJ420S Hot water <br /> O317 SF 310 510 O N- 317 517 O N - _ _ 1 I Meter(Each Unit) <br /> 280 SF r 360 SF I - o <br /> O oo REF : o Io '► •V. 1 I 7i Appliances <br /> _.� CIA I I,•. - - - <br /> — — J REF Whirlpool 25" Refrigerator 11 cuft WRT111 SFDM r <br /> ;� — �1 — �� (Owner Provided/Installed) , <br /> O 5 /I MW Whirlpool 1.6cuft Microwave 1,200W WMC30516AW <br /> O • <br /> — - — - — - (Owner Provided/Installed) <br /> RH Summit 24" H1724W Range Hood • <br /> GD 1/2" In-Sink Disposer Whirlpool GC2000PE <br /> InSinkErator Garbage Disposal Air Switch STC-CHRM <br /> 3 5 EC Summit CR2220 2-Burner Electric Cooktop. Permit Set <br /> A9.03 A9.02 <br /> Unit Fixture Flow Rates B 1804-011 <br /> Shower 1.75gpm <br /> - Kitchen 1.5gpm <br /> T pical Studio - 317 SF 2 Typical Studio - 280 SF 3 Typical Studio - 360 SF ® Typical Studio - 294 SF Bath Lay. 0.5gpm <br /> 0 3/16" = 1'-0„ 0 3/16" = 1'-0" 0 3/16" = 1'-0„ <br /> 3/16" = 1'-0" Kitchen Casework <br /> Upper White Melamine <br /> Lower Grey Melamine REGISTERED <br /> Handles 3" Satin Nickel Bar Pull (all doors and drawers) ARCHITECT <br /> Countertop 2cm Quartz(Snow White) No.8013 <br /> Backsplash 4" Quartz against all adjacent GWB surfaces <br /> Casework shall be enclosed to the ceiling with white melamine <br /> (refer to elevations) Joshua S.Scott . <br /> GENERAL NOTES: CODE NOTES: <br /> STATE OF WASHIN T N <br /> Bathroom Vanity Casework <br /> 1. All outlets shall comply with ADA reach range for outlets and switches above countertop, ensure Applicable Codes Noted on The Permit Cover Sheet White Melamine <br /> highest operable portion (centerline of upper socket, top of uppermost portion of rocker/toggle 2015 IBC w/WA State Amendments Solid Surface top w/4" backsplash <br /> switch) is within reach range. Americans with Disabilities Act(ADA) & Fair Hoousing Act(FHA) <br /> 2. Ensure environmental controls are within reach range and have a clear floor space and ICC/ANSI 117.1 -2009 Window Openings <br /> accessible route. Note that the contols are NOT required to comply with operability requirements Jambs and Header Painted GWB <br /> related to operating force, one-handed operation, or lack of twisting, pinching, and tight grasping. The following Code Provisions are Used as "Safe Harbors": Sill Painted MDF with 1x3 Apron <br /> 3. ANSI A117.1 Section 1003.11 "Reinforcement shall be provided for the future installation of grab Units: -Overhang sill +/-1" past the window <br /> bars complying with section 604.5 at water closets:grab bars complying with section 607.4 at 2015 IBC and WA State Amendments, and the 1998 FHA Design Manual (FHADM)for Scoping. opening and over apron. <br /> bathtubs and for grab bars and shower seats complying with sections 608.3, 608.2.1.3, 608.2.2.3 1998 FHA Design Manual (FHADM)for Technical Requirements. -Align apron with window opening. <br /> and 608.2.3.2 at shower compartments. The code also allows a non-compliant vanity as long as Common Use Areas: -Ensure sill fits tightly to window and is <br /> provisions are made for future conversion without the removal of the vanity. FHADM for Scoping. above the back-damn. <br /> 4. Door harware shall comply with accessibility requirements for operability, notably height, and 2009 ANSI A117.1 for Technical Requirements, as the technical standard for compliance <br /> ability to open with one hand, not requiring tight grasping, pinching, or twisting of the wrist. with the FHA requirements 1 &2, as allowed by the FHADM on pages 13,15,16,1.2,1.4, and 2.5. Window Coverings <br /> Public Use Areas: <br /> SWFcontract Manual Roller Shade <br /> 1988 FHADM for Scoping. Color: Charcoal/Platinum <br /> 2009 ANSI A117.1 for Technical Requirements. Openness factor 1% <br /> Stainless Steel Bead Chain Operation <br /> - Overhead Mount to window header <br /> Removable Sprinkler Heads : <br /> cabinet All sprinkler heads throughout shall be WHITE U.N.O. <br /> W OA 1 Ceilings less than 7'-0" shall have concealed heads. <br /> 6'- 11' "6� 6'-6 1/2" <br /> A9.02 <br /> 14'-51/2" <br /> <> / 7'-5 1/8" 2'-6 7/8" 4'-5 1/2" / <br /> , ., <br /> N p I 0 i 001 <br /> c.1 I I - - - -REF 11.611 i_ i 0 - !. <br /> 002- — sw, cokt <br /> — <br /> o um <br /> C I O ___�� o \ - <br /> 3 A9.02 i L - - I <br /> EN,`- I : REF ,1 i' •, - - io i - <br /> _ - ` / 003 2 09/01/19 Set II Rev 1 <br /> I I / <br /> o is I Studio O N _4 , _1 I <br /> I - \ — - - � # DATE DESCRIPTION <br /> , ` - , - - J I 325-525 + ® IF <br /> I L - - <br /> -\ 260 <br /> SF - 1 1 - ® i , -1F+ ..E k . <br /> _I <br /> _ o oio- <br /> 0'-7" 31_6"-2'-85/8" -5'-87/8" I m 0c \� N .ems <br /> K • I L 2'- 1" 4'-73/8" 2'-85/8" 3' -95/8" 1 J I i i I i • g I II l J <br /> l T y <br /> / / A9.03 - I I Li J- - 0 -91/8 J I Electrical <br /> I J c 3'-41/4'2'- 107/8 - 4'-51/4 2 - 1 ' <br /> Electrical �© - - I `� I I N - - X / power DEVELOPMENT <br /> power 9 3/:" I I I I I I <br /> - - J I _ panel REF = I I - - �� 01 - I 13'-6 1/2" panelBICKFORD <br /> 1'- 0 7/8" - i _ I �' _ 1830 SUITE 201 AVE, <br /> SNOHOMISH, WA 98290 <br /> o Electrical - <br /> I ' -- - _ _ _ _ Studio <br /> 206.755.1290 <br /> o co _ <br /> ' power o I - 2,- 1,, 2 A9.03 O 328-528 <br /> - I <br /> — °- panel �• I <br /> i / <br /> `I Ttl, ``' 13' 6 1/2" 280 SF <br /> IW5,.:. J ,02 CV r R�movable <br /> Studio N I I I 1 c-binet <br /> ■ 335-535 I -III <br /> -1'-6" O o O \ 1020 North Broadway <br /> O 327 SF - I I 1 / — - - - - - - — Everett,WA 98403 <br /> 1111111 <br /> w 1 <br /> REF : `-Q e c o <br /> I <br /> t — I CV Ew, <br /> i. <br /> MEM <br /> �A�� / 4'-2" 2'- 10 1/2" 6'-6" / / 9'- 3" / 4'-9 / ENLARGED UNIT PLANS <br /> C. <br /> (UNIT 213, 313,413 AND 513) (UNIT 228, 328 AND 428) <br /> DATE: Issue Date <br /> OTypical Studio - 327 SF © Typical Studio - 260 SF O Typical Type 'A' Studio -- Typical Type 'A' Studio - 280 SF SHEET: <br /> 3/16" = 1'-0" 3/16" = 1'-0" 7 3/16" = 1'-0" 8 3/16" = 1'-0" <br /> A9 . 01 <br />