My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2019 BLDG 40-58 Plans 2022-11-09 (6)
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-58
>
Plans
>
3003 W CASINO RD 2019 BLDG 40-58 Plans 2022-11-09 (6)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/9/2022 10:26:00 AM
Creation date
8/4/2021 11:25:38 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-58
Permit
M1905-081
Year
2019
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
P2P MAKE-UP AIR UNIT SCHEDULE- PAINT/PREP BOOTH#2 <br /> CALLOUT SUPPLY FAN FILTER CHILLED WATER COIL HEATING HOT WATER COIL ELECTRICAL BASIS OF DESIGN <br /> TOTAL MOTOR[9] - MAX <br /> MIN SUPPLY DRIVE MAX CFM E.S.P. MAX COOLING FLUID CHW MAX CONTROL BRANCH FLUID MAX CONTROL BRANCH <br /> AIRFLOW AIR FAN TYPE PER FAN (IN WC) RPM MAX VEL CAPACITY EAT DB EAT WB LAT DB LAT WB TYPE EWT LW GPM WPD VALVE PD PIPE SIZE EAT LAT EWT HHW TYPE WPD VALVE PD PIPE SIZE <br /> TYPE MARK - LOCATION SERVICE (CFM)[2] (CFM) TYPE [8] [1] [3] QTY [1] RPM HP BHP [5] TYPE [4] (FPM) (TONS) (DEG F) (DEG F) (DEG F) (DEG F) [7] (DEG F) (DEG F) [1] (FT) (FT) (IN) (DEG F) (DEG F) (DEG F) GPM [1] [7] (FT) (PSI) (IN) VOLTAGE PHASE FREQUENCY MANUFACTURER MODEL NOTES <br /> MAU 06 P2P-CONTROL ROOM P2P-DOGHOUSE 3 &4 1330 2660 FC DIRECT 1330 0.60 2 3227 3600 2.0 1.3 MERV 8/MERV 13 500 12 92 68 50 49.8 0 42 52 35.9 13.6 34.6 2.5 24 77 135 35.9 0 1.1 12 1 1/2" 460 3 60 CARRIER MPQN [6] [10] <br /> SCHEDULE NOTES: <br /> [1]WITH UNIT AT MAXIMUM CONDITIONS <br /> [2] MINIMUM UNIT AIRFLOW, FOR GENERAL EXHAUST MAKEUP AIR. SEE SEQUENCE OF OPERATION. <br /> [3] STATIC PRESSURE EXTERNAL TO UNIT, DOES NOT INCLUDE DIRTY FILTER ALLOWANCE <br /> [4] 2" MERV 8 FILTER& 12" MERV 13 FILTER <br /> [5] MAXIMUM ALLOWABLE MOTOR BRAKEHORSEPOWER AT MAX FLOW AND TSP <br /> [6] MAXIMUM RADIATED SOUND POWER LEVELS OF THE UNIT SHALL NOT EXCEED 85 dBA <br /> [7]WATER ENTERING WITH ETHYLENE GLYCOL AT THE PERCENTAGE NOTED <br /> [8] PROVIDE WITH INITIAL SET OF SHEAVES FOR FAN(S) TO MEET CONDITIONS AS SCHEDULED. FOLLOWING INSTALLATION AND BALANCING, PROVIDE REPLACEMENT SET OF SHEAVES FOR ACTUAL CONDITIONS, REGARDLESS OF WHETHER CONSTANT OF VARIABLE SPEED FAN(S)" <br /> [9] PROVIDE VFD RATED MOTOR, SEE ELECTRICAL DESIGN FOR VFD SPECIFICATIONS. ELETRICAL TO PROVIDE VFD, VFD TO BE FIELD INSTALLED <br /> [10] PROVIDE MANUFACTURER INSTALLED TERMINAL JUNCTION BOX ON EXTERIOR OF UNIT CASING INCLUDING ALL WIRING NECESSARY FOR VFD OPERATION AND CONTROL. PROVIDE ONE JUNCTION BOX PER VFD. <br /> P2P MAKE-UP AIR UNIT WITH DX COOLING AND GAS HEATING SCHEDULE- PAINT/PREP BOOTH#2 <br /> CALLOUT SUPPLY FAN DX COOLING GAS BURNER FILTER ELECTRICAL[10] BASIS OF DESIGN <br /> MOTOR MIN EAT LAT COMPRESSOR HEATING BRANCH MAX <br /> MINIMUM ESP CAPACITY EFFICIENCY DB/WB DBMS CAPACITY CONNECTION MAX SOUND <br /> OSA CFM FAN DRIVE CFM (IN WC) (TON) (EER) (DEG F) (DEG F) NO OF (MBH) EAT DB LAT DB SIZE(IN) VELOCITY LEVELS <br /> TYPE MARK LOCATION SERVICE [2] TYPE TYPE [1] [3] QTY RPM [1] RPM HP BHP [4] [5] [8] [9] [9] TYPE STAGES QUANTITY REFR [8] (DEG F) (DEG F) TYPE [7] TYPE (FPM) [6] V HZ 0 MOCP MCA MANUFACTURER MODEL NOTES <br /> MAU 07 BUILDING WEST EXTERIOR P2P- PAINT MIXING 6,000 BC DIRECT 5600 1.75 1 1302 1760 7.5 3.82 16 11.8 95/68 66/58 SCROLL 2 R-410A 540 24 90 NG 1-1/2 MERV 13 500 460 60 3 50 44 AAON RN016C [11] <br /> SCHEDULE NOTES: <br /> [1]WITH UNIT AT MAXIMUM CONDITIONS. <br /> [2]OUTSIDE AIR QUANTITY WITH DAMPER AT MINIMUM POSITION AND UNIT AT MAXIMUM CONDITIONS. <br /> [3] STATIC PRESSURE EXTERNAL TO UNIT. <br /> [4] MAXIMUM ALLOWABLE MOTOR BRAKEHORSEPOWER AT MAX FLOW AND ESP. <br /> [5] NOMINAL TONNAGE INCLUDED FOR REFERENCE ONLY DO NOT USE FOR FINAL SIZING OF EQUIPMENT. <br /> [6] UNIT SOUND POWER SHALL NOT EXCEED THE LEVEL INDICATED. <br /> [7] GAS CONNECTION SIZE BASED UPON 5 PSI SUPPLY PRESSURE. <br /> [8] MINIMUM EFFICIENCY AS SCHEDULED AND AS REQUIRED BY THE WASHINGTON STATE NON-RESIDENTIAL ENERGY CODE. <br /> [9] COOLING COIL ENTERING AND LEAVING AIR TEMPERATURES,WHICH DO NOT ACCOUNT FOR MOTOR HEAT GAIN. <br /> [10] UNIT CONFIGURATION SHALL HAVE TWO ELECTRICAL CONNECTIONS- ONE CONNECTION FOR SUPPLY FAN VIA EXTERNAL VFD, ONE CONNECTION FOR REMAINING. ELECTRICAL INFORMATION SHOWN REPRESENTATIVE OF COMBINED ELECTRICAL LOAD FROM BOTH CIRCUITS. <br /> [11] HORIZONTAL CONFIGURATION UNIT. <br /> P2P AIR TERMINAL SCHEDULE- PAINT/PREP BOOTH#2 <br /> AIRFLOW CAPACITY LIMITS (CFM) NOMINAL SIZE (IN) NECK DIMENSIONS (IN) BASIS OF DESIGN <br /> FOR RECTANGULAR MAX TSP DROP <br /> VIP , <br /> CALLOUT AIR TERMINAL DESCRIPTION MAXIMUM MINIMUM LENGTH WIDTH DIAMETER LENGTH WIDTH MAX NC (IN.W.G.) MATERIAL OBD FINISH MANUFACTURER MODEL NOTES <br /> EG-4 SURFACE MOUNTED EXHAUST GRILLE 375 180 10" 14" 8" 12" 20 0.02 ALUMINUM No #26 WHITE TITUS 350FL <br /> RG-1 SIDEWALL MOUNTED RETURN GRILLE 215 215 10" 14" 8" 12" 20 0.02 ALUMINUM Yes #26 WHITE TITUS 350FL <br /> SD-3 MODULAR CORE SQUARE CEILING D FUSER 350 2 • 24" 24" 10" 10" 17 0.03 STEEL No #26 WHITE _ TI,� CD <br /> - f A •N • . : •, • : ' D► - ''" CTIO , ' ` GRILL' 66' 330 1 12 •: I i' AD U o HI ' TITUS 30 FL <br /> SG-3 SIDEWALL MOUNTED ADJUSTABLE DUAL DEFLECTION SUPPLY GRILLE 6000 3000 50" 22" 48" 20" 40 0.25 ALUMINUM No #26 WHITE TITUS 301RL <br /> P2P VAV BOX SCHEDULE- SPRAY/PREP BOOTH#2 <br /> AIRFLOW <br /> CALLOUT SETPOINT ELECTRIC REHEAT COIL DUCT CONNECTIONS ELECTRICAL BASIS OF DESIGN 5 <br /> ENTERING CAPACITY <br /> MIN INLET HEATING AIR DRY CONTROL PRIMARY OUTLET DIMENSIONS <br /> EQUIPMENT DESIGN MIN STATIC CAPACITY BULB(DEG CONTROL AIR INLET <br /> TYPE MARK LOCATION SERVED FLOW FLOW PRESSURE KW F) TYPE DIAMETER HEIGHT WIDTH VOLTAGE PHASE FREQUENCY MANUFACTURER MODEL NOTES <br /> VAV 6 CONTROL ROOM LEVEL ACU-28 800 800 0.35 5 55 SCR 8" 10" 8" 277 1 60 ENVIROTEC SDR-8-EH <br /> P2P EXHAUST FAN SCHEDULE- SPRAY/PREP BOOTH#2 <br /> CALLOUT FAN [7] ELECTRICAL BASIS OF DESIGN <br /> ESP MOTOR[5] <br /> FLOW (IN W.G.) HP BHP <br /> TYPE MARK LOCATION SE CE CFM) TYPE DRI RPM QTY RPM [3] [2] V 0 HZ MANUFA RER MODEL NOTES <br /> 5 HA HOU 4, IXE C01 'r T 1.25 ,62 .00 r"P 4 3 a 'Et. ECK "A •EI- 6-1- 0 <br /> EF 60 EXTERIOR OF P2P-GUN CLEANING P2P-PAINT MIXING 3,000 CENTRIFUGAL BELT 2.00 1,207 1 1,800 1.50 1.32 460 3 60 TWIN CITY FAN BCV-200 <br /> EF 61 EXTERIOR OF P2P-GUN CLEANING P2P-PAINT MIXING 3,000 CENTRIFGUAL BELT 2.00 1,207 1 1,800 1.50 1.32 460 3 60 TWIN CITY FAN BCV-200 <br /> - -i.. 0 <br /> [1]STATIC PRESSURE EXTERNAL TO FAN, DOES NOT INCLUDE CLEA •R DIRTY FIL - ALLOWANCE. <br /> [2] MAXIMUM ALLOWABLE MOTOR BRAKEHORSEPOWER AT MAX FLOW AND TSP. <br /> [3] HORSEPOWER INDICATED REPRESENTS HORSEPOWER PER MOTOR. <br /> [4] PROVIDE MANUFACTURER INSTALLED TERMINAL JUNCTION BOX ON EXTERIOR OF UNIT CASING INCLUDING ALL WIRING NECESSARY FOR VFD OPERATION AND CONTROL. PROVIDE ONE JUNCTION BOX PER VFD. <br /> [5] PROVIDE VFD RATED MOTOR, SEE ELECTRICAL DESIGN FOR VFD SPECIFICATIONS. ELECTRICAL TO PROVIDE VFD, VFD TO BE FIELD INSTALLED. CO <br /> [6] PROVIDE WITH SPARK B RATED FAN. <br /> [7] PROVIDE WITH INITIAL SET OF SHEAVES FOR FAN TO MEET CONDITIONS AS SCHEDULED. FOLLOWING INSTALLATION AND BALANCING, PROVIDE REPLACEMENT SET OF SHEAVES FOR FAN ACTUAL CONDITIONS. <br /> [8] MAXIMUM RATED SOUND POWER LEVELS OF THE UNIT SHALL NOT EXCEED 85 dBA. <br /> [9] PROVIDE SHIELD AND DUSTPROOFING FOR MOTOR. <br /> [10] PROVIDE GROUNDING FOR FAN. <br /> [11] PROVIDE EMERGENCY/STANDBY POWER FOR OPERATING FAN AT MINIMUM CONDITIONS. <br /> [12] PROVIDE WITH FIXED DRIVE SHEAVES. <br /> L1RPH <br /> www.brph.corn Copyright©2017 <br /> Architects, Engineers, Constructors <br /> ,902033rdAveW,suite530 State of Washington FSi consulting engineers • <br /> Lynnwood,Washington,98036 Certificate of Authorization <br /> y5wood Architecture No.603235512 Solutions & Service <br /> Engineering No.3137 <br /> a <br /> ACCEPTABILITY DRAWN DATE SUBTITLE HVAC CURRENT REVISION SYMBOL DATE (V <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ZJS 04/02/19 EQUIPMENT SCHEDULESc. <br /> W2548317 5 04/02/19 N <br /> 0 Issue For Construction FSi BSC 03/08/16 5 Revision-Release 111 (PHP2-IFC Mixing Hoods) FSi AWL 04/02/19 0h VC C THIS DESIGN AND/OR CHECKED 0 <br /> F. N AWL 04/02/19 SHEET <br /> Q- 'oaf ,i SPECIFICATION IS APPROVED w <br /> 1 Revision-Release 44 FSi BSC 06/02/16 = y o <br /> �� o ENGINEER TITLE Boein 777X CWC BUILDING M2vafit ''''� i Ast-: zAPPROVED BY DEPT. DATE ZJ$ 04/02/19g cat <br /> 2 Revision-Release 59 FSi BSC 01/10/17 Lfy "' CHECKED d Q °' <br /> Q�O"Fy {� +�� APPROVED BUILDING 40-58 0 <br /> 3 Revision-Release 86 FSi AWL 04/10/18 <br /> s/oxet.EpG RED 04/02/19 JOB N0. COMP NO. <br /> 40-58-M2va i <br /> 4 Revision-Release 93 FSi AWL 06/19/18 APPROVED 04/02/19 <br /> No. <br /> 04/02/19 MECHANICAL MASTER EVERETT,WA 40-58-M2va <br />