Laserfiche WebLink
GENERAL POWER AND CONTROL LIGHTING FIXTURES ENERGY SUB-METERING SYSTEM <br /> FLAG NOTE,IN CONSTRUCTION NOTE. LIGHTING FIXTURES: UPPER CASE ALPHA-NUMERIC CHARACTER INDICATES FIXTURE TYPE. M SUB-METERING NODE <br /> LOWER CASE ALPHA-NUMERIC CHARACTER INDICATES CIRCUIT NUMBER AND PHASE FED FROM. XXX XXX SIGNIFIES METERING TYPE: <br /> 1111100. BOAT NOTE,IN GENERAL NOTE, UPPER CASE ALPHA-NUMERIC CHARACTER IN PARENTHESIS INDICATES RELAY NUMBER. <br /> [IllMEDIUM VOLTAGE CIRCUIT BREAKER DRAWOUT TYPE LOWER CASE LETTER INDICATES SWITCH LEG. VFD DIRECT CONNECTION TO VFD VIA COMMUNICATIONS <br /> AL DETAIL NUMBER "NL" INDICATES NIGHT LIGHT OPERATION(CIRCUIT NOT SWITCHED). PROTOCOL. <br /> v � <br /> CT CURRENT TRANSFORMER-BASED STAND ALONE METER <br /> 1. 1 1 . — DETAIL SHEET I ® FUSE WITH COMMUNICATIONS PROTOCOL. <br /> �' 1 STRUCTURE MOUNTED LED HIGH BAY FIXTURE. EACH FIXTURE SHALL INCLUDE <br /> � MTR FLUID FLOW METER. <br /> CALLOUT SHEET ® A QUICK DISCONNECT AND IN LINE FUSE. ' <br /> 101) DOOR TAG IN STRUCTURE MOUNTED LED HIGH EAT FIXTURE <br /> (EMERGENCY). <br /> EMERGENCY .'EACH FIXTURE <br /> ) SM SUB-METERING GATEWAY <br /> AF1 <br /> ( ) <br /> LOW VOLTAGE CIRCUIT BREAKER. SHALLINCLUDE A QUICK DISCONNECT FUSE. <br /> AT AMP FRAME/AMP TRIP. <br /> 0 I <br /> INDUSTRIAL FLUORESCENT/LED LI HTI LIGHTING FIXTURE. <br /> DISTRIBUTIONS 1 ST E I Y 1 �1 COLOR CODES INDUSTRIAL FLUORESCENT/LED LIGHTING FIXTURE(EMERGENCY) :, <br /> 0 SYNCHRONISM-RELAY <br /> Viiiii4 DISTRIBUTION PANELBOARD 480Y/277V I I WALL/RECESSED/SURFACE MOUNTED FLUORESCENT LIGHTING FIXTURE. <br /> PHASE 480Y/277 VAC POWER CABLES 208Y/120 VAC POWER CABLES <br /> POWER PANEL,208Y/120V co UNDER VOLTAGE RELAY '*_ WALL/RECESSED/SURFACE MOUNTED FLUORESCENT LIGHTING FIXTURE(EMERGENCY) A-PHASE(LEFT BUS IN PNL) BROWN BLACK <br /> [ I SPECIAL PANEL AS NOTED B-PHASE(CENTER BUS IN PNL) ORANGE RED <br /> C-PHASE(RIGHT BUS IN PNL) YELLOW BLUE <br /> GROUND ROD,"TW"INDICATES TEST WELL <br /> INSTANTANEOUS/TIME OVERCURRENT NEUTRAL GRAY WHITE ` <br /> RECESSED MOUNTED LED LIGHTING FIXTURE EQUIPMENT GROUND GREEN GREEN <br /> TW RELAY <br /> RECESSED MOUNTED LED LIGHTING FIXTURE(EMERGENCY) ISOLATED GROUND GRN/YEL* GRN/YEL* <br /> (4)#1,#6G,1-1/2"C 50N INSTANTANEOUS/TIME * GREEN NFUTRALTRACER WITH YELLOW **TI BUILDOUT ONLY-PROVIDE <br /> 51 NEXTERIOR WALL PACK(EMERGENCY) NUETRAL WITH COLOR TRACER TO • <br /> gy\ �. HOME RUN-PANEL-CIRCUIT(EXAMPLE 2V57) CROSS,MARKS OVERCURRENT RELAY MATCH PHASE <br /> 2V57-4BMA10/2,4,6 PNL-CKT <br /> POWER FACTOR CORRECTION CAPACITORS ®i WALL OR CEILING EXIT SIGN. FIXTURE SHALL BE WIRED AHEAD OF LOCAL SWITCHES.ARROW <br /> INDICATE QUANTITY OF CONDUCTORS(SIZE NOTED)LONGER SLASH AS SHOWN DENOTES DIRECTION OF EGRESS,SOLID QUADRANT INDICATES FACE. .9 <br /> INDICATES NEUTRAL WIRE(IF REQUIRED). IF UNMARKED INSTALL 3#12 AWG ^ (FUSED) <br /> ' PANEL NOMENCLATURE <br /> IN 3/4"CONDUIT.REVERSED SLASH INDICATES GROUND WIRE. � CONTROL POWER TRANSFORMER LIGHTING CONTROLS <br /> r�l <br /> CONDUIT EXPOSED(RIGID METAL) LIGHTING CONTROL SWITCHES AND OCCUPANCY SENSORS:ADDITIONAL LOWER CASE XE 4 V58-3A M A2-1 -D <br /> POTENTIAL TRANSFORMER LETTER INDICATES SWITCH LEG. <br /> CONDUIT EMBEDDED IN CONCRETE OR BELOW GRADE rr <br /> SINGLE POLE TOGGLE WALL SWITCH i/-- ±: SUFFIX D INDICATES DISTRIBUTION PANEL <br /> FLEXIBLE METAL OR LIQUIDTIGHT FLEX METAL CONDUIT AS NOTED <br /> MR CURRENT TRANSFORMER. MR INDICATES r1/4$3 THREE-WAY TOGGLE WALL SWITCH SUFFIX"-1,-2,ETC."USED TO INDICATE MULTIPLE PANELS AT SAME LOCATION WITH SAME VOLTAGE AND FED FROM SAME VAULT <br /> 0 CONDUIT TURNING UP MULTI RATIO <br /> PM ALLEN-BRADLEY POWER MONITOR 5000 $OS LINE-VOLTAGE OCCUPANCY SENSOR WALL SWITCH NEAREST COLUMN INTERSECTION <br /> 0 CONDUIT TURNING DOWN <br /> $WP SINGLE POLE TOGGLE WALL SWITCH,WEATHERPROOF <br /> LOCATION OF PANEL WHEN NOT ON FIRST FLOOR: <br /> G GROUND WIRE(SIZE AS NOTED) CI ANALOG AMMETER <br /> XX$LV LOW-VOLTAGE,2-BUTTON ON/OFF WALL SWITCH.SWITCH TO TIE , TN1 =TUNNEL LEVEL 1 <br /> G GROUND WIRE WITH EXOTHERMIC WELD CONNECTION AS AMMETER SWITCH INTO GE LIGHTSWEEP LIGHTING CONTROL PANEL(S)SERVING TN2=TUNNEL LEVEL 2 <br /> RESPECTIVE AREA. REFER TO GE LIGHTING LIGHTSWEEP CONTROL P=AUTOCLAVE PIT <br /> DRAWINGS FOR MORE INFORMATION <br /> E EMERGENCY CIRCUIT M=MEZZANINE <br /> VS VOLTMETER SWITCH U=LEVEL 2 <br /> L EXPOSED LIGHTNING PROTECTION CONDUCTOR (WHERE SHOWN)FIRST DIGIT REPRESENTS FLOOR(U-2ND FLOOR,V-3RD FLOOR) V=LEVEL 3 <br /> SECOND DIGIT SPECIFIES LIGHTING CONTROL ZONE,SEE CONTROL ZONE PLANS 2E8 C=CATWALK <br /> JB JUNCTION BOX,SPECIAL(SIZE NOTED,"WP"WEATHERPROOF) O ANALOG VOLTMETER AND 3E8 FOR ADDITIONAL INFORMATION. <br /> 0RF=ROOF <br /> CEILING MOUNTED, LOW VOLTAGE, DUAL TECHNOLOGY OCCUPANCY SENSOR WITH POWER PACK VAULT <br /> ® PULL BOX(SIZE NOTED,"WP"-WEATHERPROOF) <br /> LCP POWER PACK: HUBBELL#UVPP OR APPROVED EQUAL(FOR EACH OCCUPANCY SENSOR) <br /> ROOMS: HUBBELL#OMNI-DT-500/100 OR APPROVED EQUAL(500/1000 SQ.FEET) <br /> ____L SYSTEM GROUND CORRIDORS/TUNNELS: HUBBELL#OMNI-DT-2000 OR APPROVED EQUAL(2,000 SQ. FEET) VOLTAGE: <br /> FTB FIELD TERMINAL BOX — <br /> 4=480V,3PH,3W :, <br /> SUBSCRIPT INDICATES LOW VOLTAGE OCCUPANCY SENSOR WIRED BACK TO GE LIGHTING CONTROL PANEL 1 3=480Y/277V,3PH,4W <br /> I/O REMOTE I/O RACK <br /> a MOTOR STARTER(COMBINATION) INDICATED. 2=208Y/120V, 3PH,4W OR 120/240V, 1 PH,3W <br /> PM POWER MONITOR DEVICE <br /> ® MOTOR STARTER(MANUAL) O BUILDING MOUNTED PHOTOCELL. I PREFIX: <br /> ® SOLENOID VALVE ZONE X $HB LOW-VOLTAGE,2-BUTTON HIGH BAY LIGHTING WALL SWITCH WITH (BLANK)=NORMAL POWER PANEL :r < <br /> DESIGNATED ZONE.SWITCH TO TIE INTO GE LIGHTSWEEP LIGHTING <br /> "I" ISOLATED GND PANEL , <br /> EQUIPMENT/DEVICES CONTROL PANEL(S)SERVING RESPECTIVE ZONES.BUTTONS SHALL Z°'=400 HZ PANEL <br /> REMOTE CONTROL STATION(TYPE AS NOTED) "XE"= EMERGENCY PANEL • <br /> INCLUDE:'OVERRIDE'AND'UNASSIGNED'. REFER TO GE LIGHTING "XL"=LEGALLY REQUIRED STANDBY PANEL <br /> LIGHTSWEEP CONTROL DRAWINGS FOR MORE INFORMATION. XS„=OPTIONAL STANDBY PANEL <br /> T TRANSFORMER(CAPACITY, PHASE&VOLTAGE AS NOTED) i EMERGENCY POWER SHUTDOWN <br /> '°XU"=UPS SYSTEM <br /> -�_ NON-FUSED DISCONNECT SWITCH(ENCLOSED BREAKER OR MOLDED $T 120 MINUTE TIMER WALL SWITCH <br /> XX/Y NN EXP CASE SWITCH WHERE FAULT CURRENT EXCEEDS 1 OKA) irio 3-COMPARTMENT POWER POLE WIRE MOLD 30TP-4 $D SINGLE-POLE DIMMER WALL SWITCH •I <br /> FF XX-SWITCH RATING <br /> Y-NUMBER OF POLES <br /> FF-FUSE RATING ito 2-COMPARTMENT POWER POLE WIRE MOLD 30TP-3 <br /> NN-ENCLOSURE TYPE SYSTEMS j <br /> EXP-EXPLOSION PROOF(CLASS I/DIV I UNLESS NOTED OTHERWISE) SB SWITCH BYPASS DEVICE <br /> ALUMINUM LADDER TYPE CABLE TRAY.SIZE&HEIGHT AS NOTED ON DRAWINGS. <br /> N-1 ENCLOSED CIRCUIT BREAKER' <br /> CB MANUAL CONTROLLER Il/////I 12"CABLE RUNWAY. <br /> X-1 STARTER CE COMMUNICATIONS ENCLOSURE. <br /> O <br /> TBTEST BLOCK <br /> MOTOR(SIZE AS NOTED) Q# (1)R -5 CONNECTOR FOR DATA OUTLET. ROVI ET MODULAR STAINLESS STEEL FACEPLATE IBTH LANK COVER OR UNU(1)CAT 5e CABLE OSE PORT.SUBSCRIPT M"CE"OR"CR"INDICATED AND <br /> O GENERATOR,ALTERNATING CURRENT(VOLTAGE, KVA, ) LOW VOLTAGE CIRCUIT BREAKER. INDICATES NUMBER OF ACTIVE JACKS IF GREATER THAN 1. <br /> PHASES,FREQUENCY AS NOTED) DRAWOUT TYPE101 STAINLESS STEEL FACEPLATE WITH MOUNTING STUD SCREWS,(1)CAT 5e UTP CABLE FROM 110 PUNCH <br /> E DOWN BLOCKS INDICATED AND(1)RJ-45 CONNECTOR FOR ANALOG EMERGENCY PHONE OUTLET. MOUNT <br /> I RECEPTACLE 20 AMP DUPLEX,2 POLE,3 WIRE OUTLET AT 48"AFF,UON.COORDINATE EXACT LOCATION WITH OWNERS FIRE SAFETY REPRESENTATIVE <br /> O ELECTRICALLY OPERATED <br /> 20 CLASS I,DIVISION I EXPLOSION PROOF GFCI 125V,20A,2P,3W PRIOR TO ROUGH IN. <br /> EXP INTERLOCKING RECEPTACLE.GROUSE HINDS CPS152(RECEPTACLE) UNIT SUBSTATION TRANSFORMER CCTV OUTLET FOR INTERIOR CAMERA: SURFACE MOUNTED BOX INSTALLED ABOVE CEILING ON TILE BRIDGE <br /> AND GFS-1 (GFI MODULE)OR APPROVED ALTERNATE. 21/ `n @ WITH 1-PORT MODULAR FACEPLATE WITH 1OCAT 5e UTP CABLE AND(1)RJ-45 CONNECTOR. ROUT CAT5e <br /> I= ABOVE COUNTER RECEPTACLE 20 AMP DUPLEX,2 POLE,3 WIRE - (I) CABLE BACK TO"CE"OR"CR"INDICATED.CAMERA PROVIDED BY OTHERS. <br /> `� <br /> J OVERLOAD RELAY I® 2-PORT MODULAR STAINLESS STEEL FACEPLATE WITH(1)CAT 5e UTP CABLE FROM"CE"OR"CR"INDICATED <br /> IiG ISOLATED GROUND RECEPTACLE,20AMP, DUPLEX,2 POLE,3 WIRE 4:11 LOCKOUT RELAY <br /> AND(1)CAT 5e CABLE FROM 110 PUNCHDOWN BLOCKS INDICATED AND(2)RJ-45 CONNECTORS. <br /> PB PULLBOX. SIZE AND TYPE AS NOTED ON DRAWINGS. <br /> ro_GFI GROUND FAULT INTERRUPT RECEPTACLE,20AMP, DUPLEX,2 POLE,3WIRE etei KIRK KEY INTERLOCKS.SEE BOEING <br /> WP WP INDICATES WEATHER PROOF STANDARDS NON-PAINTED FIRE RETARDANT PLYWOOD BACKBOARD. <br /> RECEPTACLE 20AMP 4-PLEX,2 POLE,3 WIRE 0 UNDERVOLTAGE RELAY 110 110 STYLE PUNCHDOWN BLOCKS. <br /> 41) REVERSE PHASE CURRENT RELAY CCVT CCTV ENCLOSURE FOR EXTERIOR CAMERA. <br /> I* RECEPTACLE, NEMA CONFIGURATION AS INDICATED. <br /> L6-20R <br /> PHASE SEQUENCE VOLTAGE RELAY AMS AMS PANEL. <br /> � RECEPTACLE,480V/3PH,20A SINGLE,3P,4W LOCKING TYPE NEMA L6-20 1 fib <br /> GROUNDING BR BADGE READER. <br /> 0 SYNCHRONIZING DEVICE <br /> Fro RECEPTACLE,208V/1 PH,30A SINGLE,2P,3W LOCKING TYPE NEMA L6-30 BR <br /> GROUNDING PREPPED DOOR AND BADGE READER <br /> P <br /> CD JUNCTION BOX, FIELD SIZED PER NEC, —o+ LIGHTNING ARRESTER IS SUBSTATION POWER MONITOR NETWORK POINT OF CONNECTION.COORDINATE WITH OWNER FOR EXACT <br /> LOCATION WITHIN SUBSTATION. <br /> O JUNCTION BOX, 120V CONNECTION FOR FIRE SMOKE DAMPER <br /> FSD PRIMARY MEDIUM VOLTAGE FUSED Q CEILING MOUNTED VOICE/DATA OUTLET WITH(1)CAT 5e CABLE AND(1)RJ-45 CONNECTOR TO"CE"OR"CR" <br /> SWITCH INDICATED. LOCATE ADJACENT TO PROJECTOR POWER RECEPTACLE. <br /> ® JUNCTION BOX, 120V CONNECTION FOR MOTOR-OPERATED DAMPER MOD <br /> V <br /> MEDIUM VOLTAGE CABLE TERMINATION 0 2-PORT MODULAR OUTLET WITH(1)CAT 5e CABLE FROM"CE"OR"CR"INDICATED AND(1)RJ-45 CONNECTOR <br /> FOR DATA OUTLET.OUTLET IS MOUNTED WITHIN MULTI-PURPOSE POKE-THRU/FLOORBOX. REFER TO <br /> ® CONNECTION TO EQUIPMENT AS INDICATED. 208/120V POWER DRAWINGS FOR POKE THRU/FLOORBOX LOCATIONS. PROVIDE BLANK COVER FOR <br /> co GROUND FAULT MONITOR UNUSED PORT.SUBSCRIPT INDICATES NUMBER OF ACTIVE JACKS IF GREATER THAN 1. <br /> MECHANICAL EQUIPMENT TAG. <br /> DMS DOOR MONITORING SYSTEM. <br /> SPD SURGE PROTECTIVE DEVICE 1 ' FOR R FERENCE 0 LY ': <br /> $M MOTOR RATED SWITCH VENTILATION SYSTEM EMERGENCY SHUTOFF SWITCH. <br /> ; <br /> O"=' POKE THRU DEVICE REFER TO DETAIL 3 ON SHEET E508 02 46 430 STATIC GROUND RECEPTACLE <br /> PT-X PT-1 -6"POWER/DATA/AV POKE THRU DEVICE FACILITY DESIGN BY HG DATE 07 09 � 9 <br /> PT-2-8"POWER/DATA/AV POKE THRU DEVICE <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATEDRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> ACCEPTABILITYIA RER <br /> CHECKED 12/05/14 ELECTRICAL LEGEND W2548317 A 01/03/17 v <br /> A 777XCWC NEW BUILDING-RECORD WBS 2548317 JMG DFC 01/03/17 RFW 12/05/14 _ sHEET • <br /> SPECIFICATION IS APPROVED c <br /> ® ENGINEER TITLE BOEING 777X CWC BUILDING c <br /> APPROVED BY DEPT. DATE DEC 12/05/14 <br /> .. <br /> ... <br /> EO c. <br /> .,, `',,x <br /> CHECKED <br /> _ .., <br /> BUILDING 40-058 C. �. <br /> APPROVED JOB N0. COMP N0. <br /> 0 <br /> APPROVED DWG NO. <br /> ELECTRICAL MASTER EVERETT,WA 40-058-EO <br /> I <br />