Laserfiche WebLink
f <br /> LEGEND: <br /> 1. SEE LEGEND SHEET EO&El FOR ABBREVIATIONS&NOTES. <br /> ,,,::, 02.4o <br /> I F GENERAL NOTES <br /> SEE 1 E9-05 S 1 E• 05 SEE 1rE9 I. I <br /> 1 i LI , I � 1 <br /> 1 REFER TO SHEETS E509 1, E509 2& E509 3 FOR GROUNDING <br /> I � __ _ _ - I I DETAILS.COORDINATE WITH DIVISION 27 DRAWINGS AND <br /> - - - - 1 * _, SPECIFICATIONS FOR GROUNDING REQUIREMENTS. <br /> I I I <br /> AIR E2 -. — .- <br /> 2. GROUND ROD LOCATIONS SHOWN ARE APPROXIMATE. <br /> ~r CONTRACTOR TO ESTABLISH FINAL LOCATIONS.COUNTERPOISE <br /> I ` <br /> SHALL BE CONNECTED TO STEEL COLUMNS AROUND THE <br /> � PERIMETER OF THE STRUCTURE AT INTERVALS AVERAGING NOT <br /> I ,_, I121 <br /> I 1 I MORE THAN 60 FEET. •9 <br /> GROUNDING SHOWN DIAGRAMMATICAL.CONTRACTOR TO <br /> I I """""""_ 1 — { I I I ESO TABLISTIFINSL ROUTING TO AVOID DOORS AND OTHER <br /> II 1 <br /> n -, _ - <br /> \ - 6- _.... _ E.25 4 ALL GROUNDING SHALL BE IN COMPLIANCE WITH 2O14 NEC,STATE <br /> OF WASHINGTON CODES AND REGULATIONS,AND BOEING <br /> SG -G , �I h <br /> _~41 STANDARDS AND SPECS. <br /> G G G L . SEE 1 E9-09 E. #4/0 AWG BARE STRANDED COPPER INSTALLED ABOVE CEILING. <br /> Its, <br /> 6 EXOTHERMIC WELD OR BURNDY HYGROUND(TYP). <br /> I i , _ I i 8 I 1 8 CONNECT TO EQUIPMENT FOUNDATION REBAR. <br /> i I i- I 1E9 08 E5091 I ( II 11E9 08 E509 2 8. INSTALL ARMORED EDGE GROUNDING PER DETAIL 4 ON SHEET <br /> I I I E509-3. <br /> (TYPICAL) I EI _ <br /> ' _ UP AND BALL WITHIN 12" FROM PIT EDGE FOR STATIC <br /> - _ L 1 C <br /> _ €€$Iii -G - r I li 1 , <br /> 6lifi. 9 PROVIDE GROUND. <br /> I <br /> - G - I 1 ; I i 0E0 I I 1 i 1 G -- 10 > BOND TO TOOLING EQUIPMENT AS REQUIRED BY MANUFACTURER. <br /> f <br /> Q� I i I P I 1 SEE 1 E9 09 #4/0 AWG BARE STRANDED COPPER WIRE INSTALLED IN TOOL <br /> 'sue 4 1 -,/ G G I i G 9 -- I FOUNDATION. <br /> ' I I I I a IL ABOVE GROUND FOR FUTURE GROUNDING <br /> E. PROVIDE PIG TA 0 <br /> \ '. _ f CONNECTION. <br /> I <br /> �"� lit }I I I - 111WPROVIDE PIG TAIL TOOL CONTROL PANEL GROUNDING <br /> 5 CIO Vim '' __ _ _. .. E.7 6 a <br /> ,, ,......_rni , _ . <br /> it S !161 <br /> - Ilk i -,ilot, , ...w�- ... - . <br /> \ I 14 PROVIDE 1" PVC CONDUIT SLEEVE IN SLAB. PROVIDE AND BOND#4/0 <br /> g \ I I 0 NEAREST <br /> 14� - _ ; : I_ - ..wow " COPPER GROUNDING CONDUCTOR N <br /> 6 AWGDBAR BARE G I U <br /> .� - 1 G . *� ��,� � BUILDING STEEL OR GROUND LOOP LOCATION.SEAL PENETRATION <br /> �� 2 / I G _ PER SPECIFICATIONS. <br /> I I <br /> - G .. I I I I ' <br /> _ � - <br /> . : CONSTRUCTION NOTES <br /> G <br /> EXPOSED METALLIC FEATURES OF TOOL SUPPORTS ARE <br /> „,- wail AWE, 4 1 1 , <br /> 1E9-O8 E509-3 r 1. ENSURE THAT EXP I <br /> � I _ --- WELDED TO FOUNDATION STEEL TO PROVIDE A CONTINOUS BOND WITH <br /> MEM : -1:11LY-1 1 ' ,--4- -11 1 El I Iy .... .._. � � � � � THE FOUNDATION GROUNDING SYSTEM. PROVIDE ADDITIONAL BONDING <br /> ' ,.. Alla - - \�..� .< ' _ JUMPERS AS NECESSARY.SUCH METALLIC FEATURES SHALL BE BONDED ' <br /> 9 <br /> . . _ 1E.. _ L __ _ _ 6 -_:,-;, - SUCH THAT THEY MEET OR EXCEED THE PERFORMANCE REQUIREMENTS <br /> G 1E9 08 E509 2 I G I \ G �' Vim ' FOR ELECTRODE SYSTEM RESISTANCE MEASUREMENTS PER <br /> I G : iiiMiiiiii 6 SPECIFICATIONS. <br /> 4IaTO <br /> NEAREST BUILDING-'_,' �11 = �� t I I r T SHALL GROUND._.- .... , . ; © CONTRACTOR GR UND GANTRY COLUMN <br /> �... 09 2 vial ;Ag i GROUND GRID LOCATION USING#4/0 AWG BARE STRANDED COPPER <br /> �� "< I 1- THROUGH CONCRETE 2' 6"AS REQUIRED. REFER TO <br /> CONDUCTOR. BORE <br /> � - MIIII I DETAILS 5/E509 3, 2IE509 2,AND 9IE509 2 FOR GROUNDING DETAILS. 4 <br /> . _ 6 > <br /> I <br /> -. -r•- ....A _I re ..,.... ©► CONTRACTOR SHALL PROVIDE AND BOND#2 AWG BARE STRANDED ' <br /> • <br /> 4 g COPPER CONDUCTOR TO EXISTING#4/0 BUILDING GROUND GRID IN MAIN <br /> , ........ r , 4 , <br /> \ _ E TRENCH. <br /> DART linlirM 14 { . S I 1 \ G _ (a) 6 4 CONTRACTOR SHALL PROVIDE#2 AWG BARE STRANDED COPPEROS <br /> I 0 CONDUCTOR IN 3l4"PVC CONDUIT IN NORTH SOUTH AND EAST WEST <br /> : � ` <br /> I G ! i I I - I TRENCHES AS SHOWN. REFER TO DETAILS A/M523-02 AND B/M523-02 FOR <br /> ,,AKT 1 I I ' I LOCATIONS WITHIN UTILITY TRENCHES. <br /> ~... G - '- .7 <br /> I I G <br /> 4=111 "' 4 I © CONTRACTOR SHALL PROVIDE AND BOND#2 AWG BARE STRANDED ' <br /> 11101111811111 =1 G 4 L 4 ..__ " _ _._, I I COPPER CONDUCTOR TO SCAFFOLDING. ROUTE IN 3/4"PVC CONDUIT <br /> WM ____________4k ' ' A I <br /> �' FOLLOWING PATH OF OTHER UTILITIES. NOTCH TRENCH LIDS AS <br /> 000. q I REQUIRED. <br /> - - -IOWi ' -ill'_ 1E9-08 M523-02 4 I I <br /> `^ W - it 1 _ �- - > CONTRACTOR SHALL PROVIDE AND TIE-IN#2 AWG BARE STRANDED <br /> rCOPPER CONDUCTOR WITH GROUNDING PUCKS(BY OTHERS)BY <br /> mommis ,6 I \ I BOLTED CONNECTION FOR TOOLING LANE STATIC GROUND. ROUTE IN <br /> r : .I i #^y <br /> 3/4" PVC CONDUIT IN RIBBON TRENCH. NOTCH TRENCH LIDS AS <br /> i <br /> I I I I I I G, I I REQUIRED.COORDINATE WITH BOEING FOR FINAL PUCK LAYOUT. <br /> C.ART -.-_.. ICI IIIIII I II IIIIIII - -4E� Ib l <br /> - ~ - G I m REFERENCE DRAWINGS <br /> S I I I \ <br /> I I G G I G 1. REFER TO SHEETS E509-1, E509-2&E509-3 FOR GROUNDING DETAILS. <br /> NW . � 14 <br /> ..._:: I 1 2. REFER TO SHEET 1 E9-04. <br /> i _ 7 <br /> �, 1 t i j i 'itit M ._ I 3. REFERET 1 o n 5 0 <br /> _ _ _ / I I <._ I I I E E <br /> II I I <br /> 1 -2G- 1 2 3 <br /> 01 <br /> I ill I <br /> I \ � B <br /> . � � <br /> � , �__ 1I fir. I \ <br /> �._... ' SG <br /> 7 p 1 o- + O <br /> 7 -4 -5 6 <br /> 10 10 I I £ - <br /> - - _ I - <br /> _ + <br /> clt- <br /> 11 13 >li ? ' I �-_� � 3 � _ -9 <br /> 11 12 > I I Er 11 I O- ki) . , <br /> G 09 <br /> SEE 1 E911 SEE 1 E911 SEE 1 E911 + I <br /> 0- - + - <br /> -10 11 -12 <br /> ISSUED FOR °- <br /> CONSTRUCTION `f- _ + _ _ - _ — _ — + - - -1-0 <br /> STRUCTURAL -13 -14 -15 <br /> Our difference O- - -0 <br /> I is engineered. <br /> PARTIAL GROUNDING PLAN <br /> 10 SCALE: 1/16"=1'0" www.harrisgroup.com 0- I -o <br /> Harris Group REVISION "C"ONLY L - - - - - - - - J <br /> PROJECT N0: 0012630.04 T <br /> ® 00 00 - _00 00 0 <br /> DRAWN: NH PROJ MGR: RLT 0 8' 16' 32' 48' <br /> ENGINEER: MWD APPROVED: RLT <br /> SCALE: 1/16"=1'-0" <br /> CHECKED: EOF DATE: 07.09.19 <br /> DRASYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DIBEJ�r' ACCEPTABILITY RERWN DATE SUBTITLE <br /> SUBTITLE CURRENT REVISION SYMBOL DATE < <br /> wAs �� CHECKED GROUNDING PLAN W6036604 C 07.09.19 <br /> A 777X CWC NEW BUILDING-RECORD WBS 2548317 JMG DFC 01/03117 '�' a iIj THIS DESIGN AND/OR <br /> tc `�a„ A THIS <br /> IS APPROVED RFW 12/05/14 SHEET e <br /> B 777X CWC NEW BUILDING-RECORD WBS 2548317 JMG DFC 07/05/17 i,._�0�,�A a ENGINEER TITLE <br /> ® w F % APPROVED BY DEPT. DATE DFC 12/05/14 BSA STRINGER GANTRY 1 E9-08 <br /> C BSA STRINGER GANTRY-IFC W6036604 HG RLT 07.09.19 kg_ : sY CHECKED <br /> BUILDING 40-058 <br /> JOB N0. COMP N0. <br /> "� 51289i APPROVED W2548317 0 <br /> �3. ��'clSTEg�' �A' m <br /> 07/09/2019 �S`SI0NAL ���� APPROVED ELECTRICAL MASTER EVERETT,WA DWG No. 40-058-1 E9-08 <br />