(TYPICAL OF 6) EF-43,44,45,46,47,48 <br /> T 0 <br /> ,> <br /> GAS i > SA EACI > <br /> OA HEATER <br /> / <br /> FOR VFD EMCS SP EMCS <br /> CONNECTION VFD <br /> 4 VFD <br /> El I NO SEE ELECTRICAL FOR TYPICAL VFD <br /> SHEETS w CONNECTION SEE <br /> o zo ELECTRICAL SHEETS <br /> Q a Q <br /> a w co w 0 O w <br /> w ° ¢ I-. n w O w 0 <br /> a. Q w > H cn cn <br /> to Q Q Q Z Q Z <br /> Q O > a w a w <br /> Q � N cn cn cn cn <br /> EMCS EMCS EMCS EMCS EMCS EMCS EMCS EMCS EMCS <br /> (TYPICAL OF 3) <br /> MAKEUP AIR UNIT <br /> MAU-01, 02, 03 <br /> AUTOCLAVE PIT VENTILATION SYSTEM <br /> MAKEUP AIR UNIT NORMAL OPERATION: <br /> SYSTEM DESCRIPTION: THREE MAKE-UP AIR UNITS, EACH COMPRISED OF AN OUTSIDE AIR PATH WITH OUTSIDE AIR DAMPER, FILTERS (MERV <br /> 13), DIRECT FIRED GAS HEATER, VARIABLE SPEED SUPPLY FAN, AND ALL ASSOCIATED APPURTENANCES AND DEVICES DEPICTED ON THE <br /> CONTROL SYSTEM DIAGRAM. THE EXHAUST FAN SYSTEM IS COMPRISED OF(6)VARIABLE VOLUME EXHAUST FANS WITH VFDS, ONE OF WHICH <br /> IS FUTURE, AND ALL ASSOCIATED APPURTENANCES AND DEVICES DEPICTED ON THE CONTROL SYSTEM DIAGRAM. <br /> GENERAL: THE SYSTEM SHALL BE AVAILABLE FOR OPERATION AT ALL TIMES DEFINED BELOW TO MAINTAIN SPECIFIC SPACE PARAMETERS. <br /> OTHERWISE, THE SYSTEM SHALL BE IN UNOCCUPIED MODE. ALL CONTROLS SHALL BE AUTOMATIC. <br /> DEFINED OCCUPIED PERIOD: MON-FRI: 4:OOAM-11:OOPM AND SAT-SUN: 5:OOAM-5:OOPM <br /> MAINTENANCE: WHEN THE MAU SUPPLY FAN IS OFF FOR MAINTENANCE, RESPECTIVE CONTROL DEVICES SHALL BE POSITIONED AS <br /> FOLLOWS: <br /> 1. CONTROL VALVES POSITIONED CLOSED. <br /> 2. OUTDOOR AIR DAMPER POSITIONED CLOSED. <br /> SYSTEM START/STOP: THE UNITS SHALL BE STARTED/STOPPED BY THE EMCS ACCORDING TO THE SPACE TEMPERATURE SETPOINT AND THE <br /> CURRENT MODE. <br /> UNOCCUPIED MODE: THE SYSTEM SHALL REMAIN IN UNOCCUPIED MODE UNLESS THE SPACE PUSH BUTTON STYLE OCCUPANCY SWITCH IS <br /> PLACED IN THE OCCUPIED POSITION, WHICH SHALL PLACE THE SYSTEM IN OCCUPIED MODE FOR A PERIOD OF 90 MINUTES. AFTER 90 <br /> MINUTES, THE SYSTEM SHALL AUTOMATICALLY RETURN TO UNOCCUPIED MODE. THE SYSTEM SHALL BE DISABLED NORMALLY. ALL DEVICES <br /> SHALL BE THEIR RESPECTIVE OFF POSITION. THE UNITS SHALL OPERATE IN UNOCCUPIED HEATING AND COOLING MODES AS DESCRIBED <br /> BELOW. <br /> UNOCCUPIED HEATING: IF THE AVERAGE SPACE TEMPERATURE FALLS BELOW SETPOINT OF 62°F (ADJ.), THE LEAD MAU SHALL BE <br /> COMMANDED ON AFTER THE OUTSIDE AIR DAMPER IS CONFIRMED TO BE OPEN. THE SUPPLY FAN SHALL BE RUN AT 100% (ADJ.) SPEED <br /> (DETERMINED BY TAB CONTRACTOR). THE GAS VALVE SHALL BE OPENED AT 100%AFTER A 2 MIN (ADJ.)TIME DELAY. UNIT SHALL RUN UNTIL <br /> THE SPACE TEMPERATURE RISES ABOVE 65°F (ADJ.). <br /> THE EXHAUST FANS ASSOCIATED WITH THE MAU SHALL BE RUN AT FULL SPEED (DETERMINED BY TAB CONTRACTOR). THE LAG MAU'S SHALL <br /> BE ADDED IF SPACE TEMPERATURE REMAINS BELOW THE SETPOINT FOR ADDITIONAL 15 MIN (ADJ.). EACH MAU SHALL RUN A MINIMUM OF 15 <br /> MINUTES OR UNTIL THE TEMPERATURE SETPOINT IS SATISFIED, WHICHEVER IS GREATER. <br /> UNOCCUPIED VENTILATION: IF THE AVERAGE SPACE AIR TEMPERATURE RISES ABOVE SETPOINT OF 78°F (ADJ.)AND OUTSIDE AIR TEMP IS <br /> BELOW 70°F (ADJ.)AND ABOVE 50°F (ADJ.), ONE MAU &TWO EXHAUST FANS ASSOCIATED WITH THE MAU SHALL RUN AT PRESET CONSTANT <br /> SPEED CORRESPONDING TO 24,000 CFM (DETERMINED BY TAB CONTRACTOR). EACH UNIT SHALL RUN A MINIMUM OF 15 MINUTES OR UNTIL <br /> THE TEMPERATURE SETPOINT IS SATISFIED, WHICHEVER IS GREATER. <br /> AUTOCLAVE CYCLE MODE: IF THE EMCS RECEIVES A SIGNAL FROM THE AUTOCLAVE SUPPORT SYSTEM PLC, ONE MAKEUP AIR UNIT AND ONE <br /> EXHAUST FAN SHALL BE STARTED PER AUTOCLAVE CYCLE. THE MAU FAN SHALL BE COMMANDED TO ITS MINIMUM SPEED OF <br /> CORRESPONDING TO 24,000 CFM. THE EXHAUST FAN SHALL MODULATE TO MAINTAIN A POSITIVE PRESSURE OF 0.025 IN W.G. (ADJ.) IN THE <br /> AUTOCLAVE AREA WITH RESPECT TO THE EXTERIOR. WHEN THE EXHAUST FAN REACHES ITS MINIMUM SPEED, THE MAU FAN SPEED SHALL <br /> MODULATE UPWARD TO MAINTAIN A POSITIVE PRESSURE OF 0.025 IN W.G. (ADJ.)THE GAS VALVE SHALL ENERGIZE AS NECESSARY BASED ON <br /> THE HEATING MODE DESCRIPTION. <br /> HEATING MODE: IF THE SPACE TEMPERATURE, AS MEASURED BY THE SPACE TEMPERATURE SENSORS (AVERAGE OF ALL THREE), IS BELOW <br /> HEATING SETPOINT OF 65°F FOR MORE THAN 5 MINUTES, THE UNIT SHALL BE STARTED AND PLACED IN HEATING MODE. IF THE SPACE <br /> TEMPERATURE IS 2°F ABOVE THE HEATING SETPOINT FOR MORE THAN 5 MINUTES, THE UNIT SHALL BE STOPPED. IF THE SPACE <br /> TEMPERATURE IS BELOW THE HEATING SETPOINT FOR A PERIOD OF 10 MINUTES (ADJ.), THE FIRST LAG MAU SHALL BE ENABLED. IF THE <br /> SPACE TEMPERATURE IS BELOW THE HEATING SETPOINT FOR AN ADDITIONAL 20 MINUTES (ADJ.), THE NEXT LAG MAU SHALL BE ENABLED. <br /> IF THE SPACE TEMPERATURE IS 2°F (ADJ.)ABOVE THE HEATING SETPOINT, THE FIRST LAG MAU SHALL BE DISABLED. IF THE SPACE <br /> TEMPERATURE IS STILL 2°F (ADJ.)ABOVE THE HEATING SETPOINT FOR AN ADDITIONAL 10 MINUTES (ADJ.), THE NEXT LAG MAU SHALL BE <br /> DISABLED. IF THE SPACE TEMPERATURE IS 2°F (ADJ.)ABOVE THE HEATING SETPOINT FOR AN ADDITIONAL 10 MINUTES (ADJ.), THE LEAD MAU <br /> SHALL BE DISABLED. <br /> COOLING MODE: IF THE SPACE TEMPERATURE, AS MEASURED BY THE SPACE TEMPERATURE SENSORS (AVERAGE OF ALL THREE) IS ABOVE <br /> COOLING SETPOINT OF 80°F FOR MORE THAN 5 MINUTES, ONE EXHAUST FAN SHALL BE STARTED AND MODULATED TO MAINTAIN ROOM <br /> TEMPERATURE SETPOINT, INITIALLY SET AT 80°F. EXHAUST FANS SHALL CONTINUE TO BE ADDED AND RAMPED UP/DOWN SIMULTANEOUSLY IF <br /> THE SPACE TEMPERATURE REMAINS ABOVE COOLING SETPOINT OF 80°F FOR AN ADDITIONAL 15 MINUTES. IF THE SPACE TEMPERATURE IS <br /> BELOW COOLING SETPOINT OF 80°F FOR MORE THAN 5 MINUTES, ONE EXHAUST FAN SHALL BE SUBTRACTED FROM THE OPERATION. <br /> EXHAUST FANS SHALL CONTINUE TO BE SUBTRACTED IF THE AVERAGE SPACE TEMPERATURE REMAINS 5°F BELOW COOLING SETPOINT OF <br /> 75°F FOR 15 MINUTES. TWO EXHAUST FANS SHALL OPERATE FOR EVERY MAKEUP AIR UNIT AND SET ONE MAU TO A PRESET CONSTANT <br /> SPEED CORRESPONDING TO 24,000 CFM (ADJ.) (DETERMINED BY THE TAB CONTRACTOR), AND TWO EFS TO A PRESET CONSTANT SPEED <br /> CORRESPONDING TO 12,000 CFM (ADJ.) (DETERMINED BY THE TAB CONTRACTOR). <br /> SUPPLY FAN CONTROL: THE EMCS SHALL START/STOP EXHAUST AND MAU FANS BASED ON SYSTEM START/STOP. SUPPLY FAN SHALL NOT BE <br /> STARTED UNTIL THE OUTSIDE AIR DAMPER HAS BEEN FULLY OPENED. IF THE SUPPLY FAN FAILS TO START/STOP BASED ON SYSTEM <br /> OPERATION, AS INDICATED BY CURRENT SENSOR, AN ALARM SHALL BE SENT AND DISPLAYED AT THE EMCS. <br /> HEATING: THE EMCS CONTROLLER SHALL MODULATE THE DIRECT FIRED GAS HEATER BY MODULATING THE GAS HEATING CONTROL VALVE TO <br /> MAINTAIN THE SPACE TEMPERATURE SETPOINT, INITIALLY SET AT 65°F, AS MEASURED BY THE SPACE TEMPERATURE SENSOR. THE EMCS <br /> CONTROLLER SHALL MODULATE THE GAS HEATING CONTROL VALVE VIA A 2-10 VDC SIGNAL. <br /> OUTSIDE AIR DAMPER CONTROL: THE OUTSIDE AIR DAMPER SHALL BE FULLY OPENED WHEN THE SYSTEM IS STARTED AND FULLY CLOSED <br /> WHEN THE SYSTEM IS STOPPED. DAMPER POSITION SHALL BE PROVED BY END SWITCH INTERNAL TO DAMPER ACTUATOR. <br /> EXHAUST FAN OPERATION: EXHAUST FANS SHALL BE STARTED/STOPPED ACCORDING TO THE CURRENT MODE IN CONJUNCTION WITH THE <br /> MAKEUP AIR UNITS. EXHAUST FANS SHALL BE STARTED AFTER A 15 SECOND TIME DELAY. IF ANY EXHAUST FAN FAILS TO START/STOP BASED <br /> ON SYSTEM OPERATION, AS INDICATED BY CURRENT SENSOR, AN ALARM SHALL BE SENT AND DISPLAYED AT THE EMCS. THE NEXT EXHAUST <br /> FAN, BASED ON RUN HOURS SHALL BE STARTED. <br /> LEAD/LAG ROTATION: LAG EQUIPMENT SHALL BE ROTATED DAILY. ``!! ee <br /> PROVIDE CONTINUOUS MONITORING OF THE FOLLOWING POINTS AND DISPLAY AT THE EMCS: CITY OF EVERETggT yy ' , <br /> y�t`�t�WE.O Ff����R�t <br /> 1. OUTSIDE AIR DAMPER POSITION REV <br /> 2. SPACE TEMPERATURE (°F) <br /> 3. HEATING CONTROL VALVE POSITION <br /> 4. SUPPLY FAN STATUS <br /> 5. DISCHARGE TEMPERATURE <br /> LOW OXYGEN EXHAUST PURGE MODE: ON A SIGNAL FROM THE AUTOCLAVE SUPPORT SYSTEM PLC THAT A LOW OXYGEN CONDITION EXISTS, ;.Y..-. ....,,:i <br /> THREE MAU'S AND FIVE EXHAUST FANS SHALL BE COMMANDED ON AFTER ALL OA DAMPERS ARE CONFIRMED TO BE IN THE OPEN POSITION. �`�5 '. \NG C- $� <br /> THE MAU FANS SHALL BE COMMANDED TO A PRESET CONSTANT SPEED (DETERMINED BY TAB CONTRACTOR) CORRESPONDING TO 16,200 <br /> .::::, wOF WAskt, v� `' <br /> CFM EACH WHILE ALL THREE EXHAUST FANS SHALL BE COMMANDED TO A FULL AND CONSTANT PRESET SPEED CORRESPONDING TO 18,000 :'` C <br /> BRPH <br /> CFM EACH. IF THE OA TEMPERATURE IS BELOW 35°F (ADJ.), THE GAS VALVE SHALL BE FULLY OPENED TO PROVIDE HEATING. THE LOW1111111 ''Wye '� : <br /> OXYGEN EXHAUST PURGE MODE SHALL REMAIN ACTIVE UNTIL THE LOW OXYGEN SIGNAL IS RELEASED FROM THE AUTOCLAVE SUPPORT ; , ' f�r-�r �; <br /> SYSTEM PLC INDICATING THAT THE OXYGEN LEVEL IS MET. www.btph.com Copyright 0 2018 , <br /> Architects Engineers, Inc. '°gyp 51476 0 ~/'' <br /> Side at'� sk �GISTV, N' ..: <br /> t9QZ0331tl__ 530 Ax101plydlWNla fon SSIONAL ' Ct::>::``: : <br /> 4 ;fit too,603235512 is:.:; ss; 2 <br /> Pk.3137 ✓' Q <br /> N <br /> DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE _0 <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE of WA Sy ACCEPTABILITY JXK 06/12/18 AUTOCLAVE PIT VENTILATION CONTROLS W2548317 0 06/12/18 <br /> PNCl THIS DESIGN AND/OR CHECKED ' <br /> 0 ISSUE FOR CONSTRUCTION JXK JLC 06/12/18 ( /' JEW 06/12/18 SHEETSPECIFICATION IS APPROVED <br /> SZ)i w. <br /> BDE���® 9ENG ENGINEERS INC <br /> ENGINEER TITLE Boeing 777X CWC BUILDING N <br /> ENGINEEHSINC. APPROVED BY DEPT. DATE JLC 06/12I18 <br /> IV!N0.3137 CHECKED <br /> 324 a <br /> BUILDING 40-58 o APPROVED JOB NO. COMP NO. <br /> 40-58-M324a <br /> F tiP� APPROVED DWG No. <br /> PyrF OF AUZN�� MECHANICAL MASTER EVERETT, WA 40-58-M324a <br />