Laserfiche WebLink
• <br /> GREAT GL I PS m <br /> WOOD BLOCKING INSTRUCTIONS m <br /> NO�T'L>, TIE TYVO ADJACENT WALL TO CEILING 1/2' TEMPERED CLASS r. o c o�.c <br /> MAIN AND CR055 RUNNERS (RELAX DESI&N) c 1 1- E <br /> NO PLYWOOD Of NNOmm <br /> *3 REBAR EMBEDMENT OF 8 GUT AND PATCH c o 0 V i 1 E m <br /> MINIMUM WITH EPDXY 24" O.G. EXISTING CONCRETE BOTTOM RAIL so.) M a <br /> 0 0 o SLAB. BACK-FILL THE FOLLOWING ARE GUIDELINES FOR INSTALLING WOOD ,.,M : M q <br /> Q 6 MIL VISQUEEN WITH 3000 PSI U ATNERSTRIP NG o.�.%E C • <br /> ao°qo° VAPOR BARRIER 01-)12 I CONCRETEBLOCKING WITHIN THE RETAIL UNIT'S WALLS. THE • X m"� 13 <br /> —0p FIN. FLOOR BLOCKING 15 NEEDED TO ASSIST WITH THE FIXTURE SADDLE ALUM. m o a <br /> so <br /> t :•�.: '`•; ;:.:• , •— •' ` • : •� :• •;::, SLAB INSTALLATION. ALL WOOD BLOCK SHALL BE FIRE SET MASTIC o N .= o=i m <br /> O 1—II I—I I I-11-I I I-111—III=111_III III ICI i111 O III III_IIII III_I II III III=III= III III I I I <br /> RETARDANT TREATED AND INSTALLED PER LOCAL GODES. I a..r a a. w 3 <br /> SUSPENDED GEILINS NOTES I I I-1 I-1 11=III Iil I I I=1Ii—I I I-1� III a I ,_I a III=1�I 11 I-I I E-111-111E- I I I=1�1=111 111_ " • 1 N <br /> 1=1 I I_I T 1-1L1=1I1i 11 1—111=I 11=1I1—I I i—I�1111 1 11 Ill 11-1�1=111_1�1_Ti 111_11i-111_I�11 n 111E-11 <br /> iy 11=1-Ill—I I I-1�=11 H 11-III—I I I_I 11 III- I I III-III III„III—I I I_I I I ,III,111_I 11—III ,III,III-111, COMPACTED, TERMITE �� J <br /> (ALL HANGERS TO BE *8 GALV.WIRE® 2-0 O.G. _ — — — — TREATAD PLEASE REVIEW WITH GREAT CLIPS' EQUIPMENT �. <br /> IF CEILING SYSTEMS ARE NOTE CONNECTED TO PARTITIONS) REPLACE SOIL SUB-BASE INSTALLER TO ENSURE ACCURATE INSTALLATION. Z <br /> ----0 0 6 MIL VISQUEEN <br /> VAPOR BARRIER SLAB NOTES: cLa <br /> n <br /> -&I A. PROVIDE LATERAL SUPPORT WITH NO.12 GA.WIRES - I.SAWGUT ALL GONRETE. c18Sb COMPACTION - <br /> O O 0 V SPLAYED IN 4 DIRECTIONS,RO DEGREES APART. <br /> i-- ca <br /> _ I AFTER UNDERSLAB WORK 15 PREFORMED. o <br /> CONNECT AT MAIN RUNNER WITH 2-0"OF GROSSRUNNER I) STYLIST STATION ''`� Z <br /> AND TO STRUCTURE ABOVE AT ANGLE NOT TO EXCEED 2. COMPACT AND BACK FILL ALL TRENCHES - a <br /> 81 <br /> �3/8" 45 DEGREES FROM PLANE OF GEILING•THESE LATERAL SLAB REPLACE OTt I L TO 98 A) MOUNT THE BOTTOM OF ONE (I) 2 X 10 AT 24" ABOVE <br /> 4'-0' 12'-0' O.G. 3/8' MIN. CLEAR SUPPORTS TO BE 12'-0' OG.WITH FIRST POINT 3. INSTALL MINIMUM 4" GRAVEL SUBBASE AND L z <br /> FINISHED FLOOR. THE WIDTH OF THE BLOCKING <br /> MINIMUM 4" CONCRETE SLAB. E <br /> 4-0 FROM EACH WALL. SHOULD COVER AT LEAST 5 FT WIDE WHERE THE DOOR THRESHOLD I� T I L La <br /> MAX. CROSS RUNNER OR 4. DOWEL NEW CONCRETE SLABS INTO La <br /> MAIN RUNNER B. ALLOWANCE TO BE PROVIDED FOR LATERAL MOVEMENT OF EXISTING CONCRETE SLABS USING 1/2" X 16" FIXTURE WILL BE LOCATED PER THE FLOOR PLAN. z <br /> SYSTEM.MAIN AND GROSS RUNNERS MAY BE ATTACHED TO <br /> DOWELS AT 24" O.G. EMBEDDED 8" INTO z <br /> PLAN ADJACENT WALLS WITH CLEARANCE BETWEEN HALL AND EXISTING SLAB ALONG EACH SIDE OFLai <br /> RUNNER AT REMAINING 2 WALLS. TRENCH. 2) FLEX STATION <br /> MIN.NO.12 GAUGE LIGHT FIXTURES RECESSED NOT OVER 56 LBS.AND ce <br /> PENDANT NOT OVER 20 LBS.MAY BE POSITIVELY FIBER MESH MAY BE USED N LIEU A) MOUNT THE BOTTOM OF ONE (I) 2 X 10 AT 24" ABOVE Le, <br /> - ATTACHED TO CEILING SYSTEM RUNNERS WITH SCREWS P DOLE.WHEW ALLOIED ISY FINISHED FLOOR. THE WIDTH OF THE BLOCKING <br /> OR BOLTS. SHOULD COVER AT LEAST 5-1/2 FT WIDE WHERE THE <br /> 45° AIR DIFFUSERS NOT OVER 20 CBS.MAY BE POSITIVELY <br /> LOCAL COPE <br /> ATTACHED TO CEILING SYSTEM RUNNERS WITH STREWS FIXTURE WILL BE LOCATED PER THE FLOOR PLAN. <br /> OR BOLTS. P1 Le1 <br /> 5/8' TYPE 'X'GYP.BD. a <br /> G. AIR DIFFUSERS NOT OVER 30 LBS.RECEIVING NO 3) VIDEO WALL MERCHANDISER AND LOBBY 11�ATNERSTRIP M <br /> CEILING EXTRA LOAD FROM DUCTWORK MAY BE POSITIVELY <br /> ATTACHED TO CEILING WITH SCREWS OR BOLTS. MERCHANDISER SADDLE .. <br /> 3/8" MIN.CLEAR LIGHTING FIXTURES: FURNISH AND INSTALL COMPLETE A) BLOCKING SHOULD COVER THE 8 FT X 7 FT AREA �� ALUMINUM 'THRESHOLD SET C °O <br /> WITH LAMPS,BALLASTS AND REQUIRED MOUNTING HARDWARE. I "� <br /> PRIOR TO ORDERING FIXTURES,VERIFY MOUNTING METHODS <br /> IODS WHERE MERCHANDISERS WILL BE LOCATED PER THE :� IN MASTIC. 1 <br /> tuo AND FINISHES. ALL FLOURESCENT FIXTURES MOUNTED IN FLOOR PLAN. <br /> "T"BAR CEILINGS TO BE INDEPENDENTLY SUSPENDED _ p O <br /> WITH 2 CO STFFI WIRES DIAGONALLY. INSTALLATIONS <br /> IN FIRE-RATED AREAS TO BE DONE ACCORDING TO CODE <br /> LEVITRON T5832-YV a ° : . H`- REQUIREMENTS. u5B OUTLET 4) TOWEL CABINET AND BROOM CABINET "a. �" <br /> D. CONTRACTOR TO PROVIDE COMPRESSION STRUT® I2'-0"O.G. \ ® / A) BLOCKING SHOULD COVER AN AREA 2 FT ABOVE - g0,0 <br /> ELEVATION <br /> FINISHED FLOOR TO 6 FT ABOVE THE FINISHED �^ �o <br /> OUTLET ■ q ° FLOOR. THE WIDTH OF THE BLOCKING SHOULD COVER `-i‘o AT LEAST 4 FT WIDE WHERE THE FIXTURE WILL BE -'11 `'� <br /> LOCATED PER THE FLOOR PLAN. 00 <br /> THRESHOLD i7ETA I L ` �'' N <br /> SUSPENI,Ei,7 CE I L I NO I�ETAILS ° <br /> o u5B 5) RESTROOM FIXTURES 1-4 IQ <br /> CHARGING A) BLOCKING SHOULD BE PROVIDED, A5 NEEDED, TO 0 <br /> ENSURE RESTROOM FIXTURES (INCLUDING TOILET O o <br /> PAPER HOLDER,HAND BLOW DRYER,SINK,ETC) HAVE " P'., <br /> ADEQUATE SUPPORT WHERE STUDS MAY NOT BE ABLE <br /> OFFICE AREA USB/OUTLET r,ETA I L TO BE LEVERAGED. UL-U419 <br /> NON BEARING WALL <br /> e, <br /> REFERENCE SHEET A-2 FOR WOOD BLOCKING LOCATIONS. l FIRE RATED A55BNBt Y DM 9/ <br /> I•rrorcr Na m Igan <br /> 0 0 ° 0 =IGO STAIT <br /> MN 3TAIT <br /> OIXITD 5TA1l <br /> Iiiii' v Mill""""""------"""""""—""—'llri:::-----1.V:.igl—""n"."-" IIMIA"--"-- <br /> u 0 <br /> NOTES: <br /> • I.MAXIMUM DOOR OPENING EFFORTS <br /> / / OF 5 LBS.AT EXTERIOR AND <br /> L FLOOR AND CEILING,RUNNERS-(NOT SFIOWI-CHANNEL SHAPED RUNI,EZS, 3-5/8 IN.WIDE MIN),I-V4 <br /> / INTERIOR DOORS FASTENERSIN. GS,FORMED F OM24 MIIN NO. <br /> MAXI GALV.STEEL, ATTACHED TO FLOOR AND CEILING WITH <br /> • 2.ALL DOORS SHALL BE EQUIPPED 2. <br /> // WITH SINGLE-EFFORT,NON-GRASP FROM MI STUDS- L EE 6 IN D2 IN MAXN LEGS,3/8 IN FOLDED BACK RETURNS,FORMED <br /> ..]I � 1 � HARDWARE CENTERED BETWEEN 3p" FROM MIN NO.25 MEGMSG GALV STEEL SPACED 24 IN OG M <br /> TO 44' ABOVE FINISH FLOOR. <br /> 3. BATTS AND BLANKETS'-(OPTIONAU-MINERAL WOOL OR GLASS FIBER BATTS <br /> PARTIALLY OR COMPLETELY FILING STUD CAVITY. <br /> �ry 3 5/8"x IS GA.w/ FINISH AS PER <br /> // 10' KICK (I)3/16" IGBO 1663 AT EACH PLANS AND SECTIONS STB4TT5M17p.IMCET507, ICA7BS RYFOR/WESaFCL SSF7®GOPM i <br /> �_PLATE • - ECO END.ATTACH TO METAL TRACK <br /> N10 w/#8 SCREWS AT 24"O.G. METAL STUD FRAMING 4. GYPSUM BOARD°-5/B IN THICK,4 FT WIDE,ATTACHED TO STEELSTUDS AND FLOOR AND CEILING TRACK WITH <br /> �J1 IN LONG.TYPE S STEEL SCREWS SPACED 8 IN OC ALONG EDGES OF BOARD AND 12 IN OC IN THE FIELD OF <br /> Ilk (2) #8 AT EACH 3 5/5" REFERTALPLANS FOR c. GAUGE, THE BOARD. JOINTS ORIENTED VERTICALLY AND STAGGERED ON OPPOSITE SIDES OF THE ASSEMBLY. WHEN <br /> FRONT O O R L T I O NAND SPACING ATTACHEDFURRING <br /> TO ITEM 6 KITH(RESILIENT ON&TCHANNELS) O G (FURRING CHANNELS),N WNJJ30ARD IS SCREW ATTACHED <br /> Millillia— <br /> TO FURWNG CHANNELS WITH I IN LONG TYPE 5 STEEL SGRt3N5 SPACED 12 IN OC. <br /> 3 5/8" OR 6"(ACC #8 SCREWS EA.SIDE <br /> MEN WOMEN UNISEX PLANS) DEMO 20 GA. OF STUD TO TRACK(TYP. AMER/CAN GYPSUM CO-TYPES AO-C,AGX-G BORN_GYPSUM INC-TYPE BG-C CANADIAN GYPSUM <br /> . /VA 1111 <br /> TRACK(TYPJ UNLESS COMPANY-TYPES AR,G,IP-X2,SOX,SHx,OR WIRX <br /> TOILET ROOM 60" A.F.F. NOTED <br /> D OTHERWISE <br /> TH R ISE CONTINENTAL GYPSUM COMPANY-TYPES CG-C,CG5-5,C66-6,CG CGTC-C <br /> EXISTING STEEL <br /> I _ ROOM <br /> }� G STRUCTURE CONCRETE SLAB G-P GYPSUM CORP.-TYPES 5,4,C,GPPS6 <br /> DOOR SIGN TO l L E I ROO I_I DOOR R SIG j LAFARGE NORTH AMERICAN INC-TYPES LGFG2,L GFG2A LGFGb,LGFGSA,LGFG�,LGFG�/A <br /> (— ///��, FLOOR FINISH <br /> G: ; 7..,, _ NATIONAL GYPSUM BOARD co-TYPES PSK,P51G�.,13K-C, F5W G,F5W6,FS1N <br /> IN NOTE4. PICTOGRAMS AND/OR LETTERING a •,4 <br /> 4 177 DIA.HILTI POWDER PACIFIC COAST BUILDING PRODUCTS INC TYPE PG-C OR PG-4 <br /> ARE NOT REQURED ON DOOR-MOUNTED SIGNAGE 3 5/8"METAL STUDS 4 :e, d. ,, a ACTUATED FASTENER W/ <br /> Pr TOILET ROOM AT MAX.4'-0"O.G. .•a •'•• 24 a , 3/4'EMBEDMENT AT 24° SIAM GYPSUM INDUSTRY(SARABIIRI)CO LTD-TYPE -I <br /> WALL SIGN FOR BRACING ONLY <br /> a •. ,' O.G. I GBO IIESR 1663 STANDARD GYPSUM LLG-TYPE 5G-G <br /> OTES: TEMPLE-INLAND FOREST <br /> I.SIGNS SHALL BE 1/4"THICK PAINTED AGR"LIG, 'MEN" "WOMEN" <br /> FLOO I� TR �i1< �ETl�I L UNITED STATES GYPSUM CO TYPE AR,C,FRX-6, X2,IPC-AR,SCA,SHX,&RC OR Wwc <br /> OR <br /> CENTERED ON THE DOOR AT MATTE FINISH,I/4' TEXT RAISED -�. SCALE:NOT TO SCALE USG 11EXIG0 5 A DE c v-TYPE AR,C,IP-AR,IP-X2,IPG-AR SOX,SHx,MC OR WRx ILLJ <br /> A HEIGHT OF 60°A.F.F.AND THEIR RADIU'�;E3?6ES. $ 3/4" HIGH.WIDTH- / /� <br /> IIIIIILCOLOR AND CONTRAST SHALL BEN TO-HEIGHT RATIO OF / <br /> DIFFERENT FROM COLOR AND 3:5 TO I:1 AND 4A.GYPSUM BOARD*-(AS ALTERED TO ITEM 4)-NOM 5/8 IN THICK GYPSUM PANELS WITH BEVELED,SCARE OR <br /> CONTRAST OF THE DOOR STROKE WIDTH-TO- EXIST.STRUCTURE ABOVE TAPERED EDGES,APPLIED VERTICALLY OR HORIZONTALLY. VERTICAL JOINS CENTERED OVER STUDS AND 0 <br /> WOMEN STAGGERED STUD CAVITY ON OPPOSITE SIDES OF STUD''. HORIZONTAL EDGE JOINTS HORIZONTAL BUTT JOINTS w <br /> O O OELEVATION HEIGHT RATIO OF I:5 ON OPPOSITE SIDES OD 5MY NEED NOT BE STAGGEREDOR BACKED. PANELS ATTACHED TO STEEL STUDS AND nil <br /> TO I:10 FLOOR RUNNER WITH I IN LONG TYPE 5 STEEL SCREWS SPACED 8 IN OC WHEN APPLIED HORIZONTALLY,OR 8 IN OC C L <br /> ` .• • •.• ALONG VERTICAL AND BOTTOM EDGES AND 12 IN OC IN THE FIELD WHEN PANEL ARE APPLIED VERTICALLY. O r ' <br /> PARALLEL TO STRUCTURE �/ V <br /> CANADIAN GYPSUM COMPANY-TYPES AR,G,IP-AR,IP-X2,IPG-AR,SCX,SHX,NW OR WRX UNITED STATES GYPSUM H. L.L. COCO-TYPE AR G,FRX-G,IP-AR IP-X2,IPG-AR SOX,SHX,WRG OR WRX Z I� CO <br /> GRADE 2 BRAILLE w/ SEE CONNECTION DETAIL USG MEXICO 5 A DE C V-TYPE AR,C.IP-AR,IP-X2,IPC-AR,SOX,SHX,PIRG OR MX ) CI UJ <br /> • <br /> DOTS 1/10 INCH O.G. ON THIS PAGE L V <br /> 60'OFF. IN EACH CELL,2/10 SUSP. ACOUSTIC.TILE U <br /> / INCH SPACE BETWEEN <br /> jNOTES CELLS AND DOTS DESCRIBED IN ITEM 4A WITH SOREN LENGTH INCREASED TO I-I/4 IN Q <br /> CEILING GRID 4t3.6YPSUM BOARD*-(A5 AN ALTERNATE TO ITEMS 4 OR 4A)-NOM 3/4 IN THICK,4 FT WIDE INSTALLED A5 in <br /> MS <br /> J <br /> / USE MA'1FAGTURERS SHALL BE RAISED Z D .. <br /> i/ I/40INCH. L <br /> '/ STA47A.RD BLUE $ WHITE CANADIAN GYPSUM COMPANY- I TY=AR IP-AR /1 Lu <br /> GO-ORS UNITED STATES GYPSUM CO-TYPES AR IP-AR Z <br /> USG MEXICO 5 A DEC V-TYPES AR,IP-AR <br /> 1 / <br /> 5/8"GYP.BD.w/3 5/8" 20 GA.MTL.STUDS, z O <br /> ♦ • ♦• / TO I LET ROOM '4A L L SIGN 24"0.G.,5/8"GYP.BD.TAPED,SANDED,AND 5. JOINT TAPE AND COMPOUND-VINYL,DRY OR PREMIXED JOINT COMPOUND,APPLIED IN TWO COATS TO JOINTS L <br /> READY FOR PAINT. AND SCREW HEADS,PAPER TAPE,2 IN WIDE,EMBEDDED IN FIRST LAYER OF COMPOUND OVER ALL JOINTS. AS AN L Z <br /> r ALTERNATE,NOMINAL 3/32 IN THICK GYPSUM VENEER PLASTER MAY BE APPLIED TO THE ENTIRE SURFACE OF <br /> t ' CLASSIFIED VEER BASEBOARD. JOINTS REINFORCED. �� LI O <br /> -� _ <br /> / X _ ) > <br /> *,10, \ — Z Q / 1 _ O b. RIBBING CHANNEL-(OPTIONAL-Nor SHOWN)-25 MEG GALV STEELRESILII3IT GINANNH S SPAGD �_ L Q <br /> ` \ 1 Z i . , 0O O V VERTICALLY A MAX <br /> 4 INPORTION ATTACHED TO EACH INTERSECTING STIR WITH V2 IN LONG TYPE V/=ill i� --I 1 \ `J i Z b O O o <br /> ���tia �`__/ cry <br /> wii► r0 IR I7EMLSING HALL __ SUSPENDED <br /> ks <br /> I O E I I CEILING DETAILS <br /> 8"MIN.—.— <br /> REVIEWEDFOR PER@ IT ACCESSIBILITY <br /> NOTES <br /> y f 6""�`" WOMEN RESTROOM RESTROOMS TRACK AT FLOOR DETAILS <br /> I7"M►N. MENfatE\ 1/ I I/ `I I ` I/ PAGEDETAIL ON THIS <br /> NO PERMANENT ATTACHMENT TO <br /> HALL SI GNAGE (TYP.) THE UNDERSIDE OF THE ROOF <br /> TYPICAL HALL SECTION <br /> WITHOUT LANDLORD'S V'RITTEN A4 <br /> SCALE:NOT TO SCALE <br /> CONSENT. <br />