FRP, FROM FIN. 5/8" TYPE „X„ I FRP, <br /> FROM FIN. <br /> FLOOR TO 6" ABOVE ::: FLOOR TO 6" ABOVE <br /> GWB EA. SIDE <br /> FIN. CEILING VINYL • E SAL OTES <br /> WALLCOVERING i FIN. CEILING @ D1 • <br /> 5/8 TYPE "X" J E <br /> 5/8 TYPE X ( ) 8 18 GA. MTL STUDS I 5 » • GWB EA. SIDE <br /> . LA ERS 8 <br /> GWB EA. SIDE 1/4" : - @ 24" O.C. MAX <br /> - - � ALL WALLS AND FINISHESAREBEFROMFINISHED <br /> 2 LAYERS TYPE TYPE "X" GWB EA. FLOOR TO UNDERSIDE OF STRUCTURE EXCEPT AT AREAS <br /> "X» GWB EA. SIDE . . SIDE WITH FINISHED CEILING, GWB TO EXTEND 6" ABOVE <br /> 6" 20 GA. MTL 3/4" VERT. FIRE : I FINISHED CEILING. <br /> STUDS @ 16" O.C. RETARDANT FIBERBOARD I 6" 14 GA 6" 20 GA. MTL <br /> 6 20 GA. MTL STUDS <br /> @ 16" O.C. MAX <br /> X : • •SPACERS @ 24" O.C. MTL STUDS @ 16" O.C. 2 PROVIDE DEFLECTION TRACK AT ALL FULL HEIGHT WALLS AS <br /> STUDS @ 16 O.C. 534, EXCEPT AT <br /> INDICATED ON DETAIL 8/A576 AND 6/A <br /> ACOUSTIC BATT • <br /> FIRER RATED WALLPROVIDE <br /> INSULATION 1/2" X 9" HORIZ. FIRE r I D DETAIL 10/A576. <br /> ATP OVI <br /> • • - RETARDANT FIBERBOARD <br /> ACOUSTIC -ACOUSTIC BATT <br /> (6' LENGTHS WITH BUTT I INSULATIONSA� INSULATION 3' INSTALL CONTROL JOINTS AT GYPSUM WALL BOARD WALLS <br /> JOINT ENDS & VERTICAL I AT MAXIMUM 30 —0 O.C. HORIZONTALLY. <br /> 1 GAP BETWEEN BOARDS) <br /> • <br /> DOUBLE BEAD OF <br /> • ACOUSTIC SEALANT <br /> • �— DOUBLE BEAD OF BELOW TRACK <br /> ACOUSTIC SEALANT <br /> BELOW TRACK <br /> 2 HR RATED CONSTRUCTION <br /> PER UL DESIGN NO. U419 <br /> WALL TYPE WALL TYPE WALL TYPE © WALL TYPE WALL TYPE <br /> A B D <br /> SAME AS ABOVE W/ Al SAME AS ABOVE W/ D1 <br /> FRP, BOTH SIDES, TO FRP, ON INTERIOR <br /> 6" ABOVE FIN. CEILING SIDES, TO 6" ABOVE <br /> FIN. CEILING O <br /> FRP, FROM FIN. FLOOR <br /> TO 6" ABOVE FIN. <br /> CEILING, BOTH SIDES <br /> HORIZ @ <br /> - �, „ » 24" 0 C <br /> 5/8" . / <br /> TYPE "X" : 5/8 TYPE X <br /> 5/8" TYPE "X„ GWB 5/8" TYPE "X" GWB EA. SIDE GWB EA. SIDE <br /> GWB EA. SIDE <br /> �TO 9 —0 A.F.F. • • 600S125-30 . <br /> • • <br /> • <br /> STUDS @ 16" 0 C <br /> • —8" 20 GA. MTL 6" 20 GA. MTL <br /> 6" 20 GA. MTL STUDS @ 16" O.C. —3 5/8" 20 GA. MTL STUDS @ 16" O.C. <br /> STUDS @ 16" =I STUDS @ 16" O.C. ' ".. .. <br /> • MECHANICAL ROOM SIDE <br /> - O.C. . <br /> . 1 " AIR GAP, UNLESS <br /> WIDTH NEEDS TO <br /> . <br /> • <br /> BECOME GREATER TO <br /> - ACOUSTIC BATT : ,� ACOUSTIC BATT ACOUSTIC BATT INSULATION <br /> • INSULATION INSULATION ENCLOSE EXISING PIPE <br /> N UI AND CONDUIT <br /> . (2) LAYERS 5/8" TYPE „X" GWB <br /> BATT • EA. SIDE <br /> ACOUSTIC B <br /> • <br /> INSULATION <br /> - <br /> WALL TYPE WALL TYPE WALL TYPE WALL TYPE WALL TYPE <br /> o ® ® STC-56 0 <br /> 1 " AIR GAP <br /> RC-1 CHANNELS- <br /> HORIZ. @4" O,C. . <br /> i <br /> 5/8" TYPE "X" GWB <br /> 1 SHAFT WALL <br /> LINER <br /> PANELS <br /> RC-1 CHANNELS (2) LAYERS 5/8" TYPE <br /> (2) LAYERS 5/8" <br /> HORIZ. @ 24" O.C. "X"-- ' X GWB FLUSH WITH <br /> TYPE „X" GWB ' • FACE OF BRACE <br /> 4" C 16" 0 C <br /> 6005125-30 STUDS @ 16" O.C. INFILL EXISTING WALL- _ — <br /> _ � H STUDS @ <br /> 4005125-30 STUDS- <br /> BRACES W/ 6005125-30 1 - (400H150-30) <br /> @ 16" O.C. 7 -�..:..: STUDS @ 16" O.C. <br /> • • MECHANICAL ROOM SIDE <br /> --ACOUSTIC <br /> USTIC BAIT <br /> ACOUSTIC BATT INSULATION ACOUSTIC BATT INSULATION INSULATION <br /> (2) LAYERS 5/8" TYPE "X" GWB <br /> 14 5/8" STRUCT K—BRACE <br /> WALL TYPE 0 WALL TYPE . , ..„_, ,iii .w, # <br /> EXCEEDS STC-59le"--7 bt ! , / ill) , I <br /> www.brph.com Copyright©2018 <br /> Architects Engineers, Inc. <br /> State of Washington <br /> 19020 33rd Ave W,Suite 530 Certificate of Authorization <br /> Lynnwood,Washington,98036 Architecture No.603235512 <br /> 425-921-3500 Engineering No.3137 <br /> DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE <br /> ACCEPTABILITY KAG 06/15/18 <br /> 1 THIS DESIGN AND/OR CHECKED WALL TYPES 16322 06/15/18 <br /> 0 Temp MCS Utilities & Trenches — Issue for Construction (WBS16322) KAG KML 06/15/18 Ken" L. -" REGISTERED SPECIFICATION IS APPROVED WMD 06/15/18 SHEET <br /> 065• A. 0:47 201 (-AR TETTECT <br /> ® ®'' APPROVED BY DEPT. DATE KMLNEER 06/15/18 TITLE FACTORY TRANSFORMATION - 777x Wing Body Join <br /> J\352b 823 <br /> `�` CHECKED � <br /> KENNETH M. LOWERY APPROVED BUILDING 40-025 JOB NO. COMP NO. <br /> STATE OF WASHINGTON WO 15/2899-823 <br /> APPROVED ARCHITECTURAL MASTER EVERETT, WA DWG NO. 40-025—A352b-823 <br />