Laserfiche WebLink
LEGEND <br /> SEE SHEETS 40-58-M1a-a,40-58-M1b-a,&40-58-M2a-a FOR <br /> KEY,LEGEND,AND GENERAL NOTES. <br /> TOP TO BOTTOM, SOUTH TO NORTH TOP TO BOTTOM. SOUTH TO NORTH TOP TO BOTTOM,SOUTH TO NORTH , TOP TO BOTTOM, SOUTH TO NORTH TOP TO BOTTOM, SOUTH TO NORTH COORDINATES: <br /> BOP 46'-1 7/8"(ABOVE PIT FLOOR): BOP 46-1 7/8"(ABOVE PIT FLOOR): BOP 46'-1 7/8"(ABOVE PIT FLOOR): ' BOP 46'-1 7/8"(ABOVE PIT FLOOR): 1 BOP 46'-17/8"(ABOVE PIT FLOOR): X=NORTH-SOUTH <br /> 3"CONDENSATE WI 2 1/2" INSULATION, 3"CONDENSATE W/2 1f2" INSULATION, 3"CONDENSATE W/2-1/2" INSULATION, 3" CONDENSATE W12-1/2 INSULATION, 3'CONDENSATE WI 2-1/2" INSULATION, Y=EAST-WEST <br /> 2"HP CONDENSATE W/2-1/2" INSULATION, % 2"HP CONDENSATE W/2-1/2" INSULATION, 2" HP CONDENSATE W/2-112" INSULATION. i 2"HP CONDENSATE W/2-1/2" INSULATION, Z=VERTICAL <br /> 6" PROCESS MTER, 6"PROCESS WATER, 6" PROCESS WATER, I 6"PROCESS WATER, !", 6" PROCESS WATER, <br /> 6"CTWS TO SSF, 6"CTWS TO SSF, 6"CTWS TO SSF, ! BOP 41'-41/4"(ABOVE PIT FLOOR): BOP 41"-1 1/2"(ABOVE PIT FLOOR): <br /> • I 6"CTWS FROM SSF, 6"CTWS FROM SSF. 6"CT`g'S FROM SSF. 8" HP STEAM W/5" INSULATION. I 8" HP STEAM W/5" INSULATION. GENERAL NOTES <br /> BOP 41' 11 1I2"(ABOVE PIT FLOOR): BOP 41' 1 O 1/2"(ABOVE PIT FLOOR): BOP 41 8 3/4"(ABOVE PIT FLOOR); ( BOP 40'-11 3/4"(ABOVE PIT FLOOR): BOP 40'-113/4"(ABOVE PIT FLOOR): <br /> , 8'" HP STEAM W/5" INSULATION. 8" HP STEAM WI 5"INSULATION. 8'"HP STEAM W/5" INSULATION. 14"GN2, 14"GN2, <br /> 8" HP STEAM WITH 5"THICK INSULATION:BOP BOP 40'-11 3/4"(ABOVE PIT FLOOR): BOP 40'-11 3/4 (ABOVE PIT FLOOR); BO 40' 11 3r4 (ABOVE PIT FLOOR); _ 20°GTV�fS FROi11 COOLING TtOVUERS 6"GAS, 6"GAS, 6"MCCWR DOWN INTO 36"COLLECTION PIPE. <br /> 6"GAS. 6"GAS, 14"GN2, _ 8" MCCWS. 8"MCCWS, 20"CTWR UP TO <br /> ROUTED AT APPROXIMATELY 42' 2"APF.SLOPE 6"GAS, O LING TOWERS 2. BRANCH CONNECTIONS TO 36"COLLECTION PIPE SHALL BE WELD 0 LET <br /> STEA,�v1 PIPING 1/2"PER 10'IN DIRECTION CF 8"MCCWS CONNECTIONS, <br /> TRAVEL. 1 1/2" CA UP TO BUMPOUT ROOF <br /> , . , \ . <br /> © PROVIDE 3/8"REINFORCING PAD AT CONNECTION TO 36"CO <br /> LLECTION <br /> _ _a _ _.' �, � _ _ , .. m ._ . . . PIPE. <br /> _ , .. ,. .., . �, :. _r ,�� ,�.. ..,... ,rt.,� .�x ,,. .�,..�.2�<� �.�..� ,�, .. ,..�. N, ,. ,.....r .� _ ,.,_ ru, = T. ,_,.x...:.�_ . xv.,.,.�.�ru.._. ...r.... .,. . _M_ ._,r �.. ,.., �_� _, . . .... .. .......K. ... �,_, .__.,_�. , fi � ,.., � �.�x_�t .,...� TM .�. <br /> - t_ I i <br /> ---- -°a� ---' -_--° --,-� _ ,. , .:.- ; , 4 6 VENT UP OUT OF 36 COLLECTION PIPE. <br /> �! ) 6"G ' 5, EQUIPMENT, PIPING, ETC.THAT IS GREYED OUT IS EITHER EXISTING OR TO <br /> _ 7. BE INSTALLED WITH SUBSEQUENT AUTOCLAVES AT A LATER DATE. REFER <br /> i ___ \ \ v I � TO AUTOCLAVE SUBSYSTEM SCHEDULES FOR INDICATION 0 <br /> IL 4 _ \ r INSTALLATION PH SE. <br /> j 2 , �I <br /> l r i s �111 i SII,. i�° <br /> C ,..._____ _-_- � �, __-._.�_...__ -.«._..- -..ram.- __._._...y=_. <br /> 6., ! - - - - _�--_. __ ... ____ __ _ .; COMPRESSED AIR FILTER AND TEST PORT ASSEMBLY,REFER TO P&ID <br /> �� 3" MCCWS � I I �'� !, r i SHEET M334a a. <br /> 6 9 l 8" MCCWS r— <br /> '441 <br /> �® �� 3 MCCWS ✓� _. ! , 20"CTWR y <br /> .i 1CCWS <br /> L <br /> 3�� PW TYP. � ��_ .;:; <br /> CONDENSATE 4 10"VENT , is <br /> f, I 7 8 \ STEAM AND CONDE�d 1 1/2 CA <br /> • 14"GN2 \ 3/4"CA "CHEMICAL <br /> RE I URN EXPANSION LOOPS, �_ 8"APV VENT , <br /> 1-1 11 I REFER TO PLANS FOR � 1 (I.; :' REATMENT ill �_ <br /> is 1, -- HPS DRIP LEG, I I Ea, -1 1/2 CA <br /> TYPITSL III <br /> ,' DIMENSIONAL REQ I REM . '1 <br /> AREA TO HAVE NO PIPING OR AREA TO HAVE NO PIPING OR ;� 8"MCCWS ] 1•1,,, <br /> ' 1"CHEMICAL ! i ' `0 ACWS <br /> I <br /> TREATMENT i� �� ( � <br /> OBSTRUCTIONS FOR AUTOCLAVE 3 OBSTRUCTIONS FOR AUTOCLAVE 2 20 CTWS I t 3 BLOWDOWN <br /> All ti 8"APV EXHAUST <br /> L I# INSTALLATION. INSTALLATION. I Imo,., , <br /> f <br /> 16 Ii �, - <br /> 1 <br /> 3"CONDENSATE <br /> 2' CA 1 I;:I 6" SSF -� <br /> 1 H.' 4 �- � 8" STEAM <br /> p\ 4' 14"GN2(BEHIND) <br /> tt T _ : •-: j I OPall .-_- <br /> : ' \OSSF �_. . . _ - _-_ $ - - \ ©I �710E1 \ �\ <br /> I \700W� AUTOCLAVE PIT 91-0 to'''k,p, n \_ "" - -- <br /> I p , , , <br /> VAULT HAT H �_ <br /> t; _,III ♦i ,rs!/ b .,.,,..a—_ .....-a ,., ...«.:.._, ,,,. ...,» ,..:, .... .-. - ..... .... .. /'� - -c„�'^� - ,, _ , '„ <br /> „ Ii . <br /> ,, , -- - I <br /> : _L _ , , _ __ <br /> '', <br /> b <br /> t <br /> STEAM TRAP, I YP. --- ,,, :.: .=_ <br /> �._..�.,.a... �.,,.<Y,».«�.-.,�-.�,_>.�.,,K.,......�.,»_�. � IM1!t�A1, .�71ML�,di"A,,. .,.�. «�e - -..,.�:�«m,...d ,m...P... <br /> \' 10 ,.- ;__ _ _ .-. _. .a__ _, ._. __, _s - _ _ ra _am.. _._ _.__ -. ._ . �._. - w -- — — ---- --_ __.-- r _ NORTH 6 '.- . RT 6 <br /> VAULT ` ' _ - 12"OVERFLOW -� <br /> 1:.# 20"CTWS DOWN INTO COLD WELL --- <br /> , ill , <br /> . . <br /> CONSTRUCTION NOTES <br /> INSTALL NON-SLAM CHECK VALVES ON THE EXISTING COLDWELL <br /> NORTH WALL INTERIOR PIPING (N/S) 1 AND HOTWELL PUMP DISCHARGE.PROVIDE SPOOL PIECE FOR <br /> FLANGE-TO-FLANGE CONNECTION BETWEEN CHECK VALVE AND <br /> EXISTING PIPING. <br /> SCALE: 3/32"= 1'-0" 1M160-29a M535a <br /> �� © CONNECT 6"CTWS PIPING TO SIDE STREAM FILTER INTO EXISTING <br /> 8" MCCWS HEADER. <br /> © CONNECT NEW 1"ACWR FROM WATER CHEMICAL TREATMENT <br /> SYSTEM PANEL TO 20"CTWS. <br /> tio- CUT NEW TEE INTO EXISTING 8"MCCWS HEADER FOR NEW 3" <br /> 1 MCCWS TO TIE INTO EXISTING 3"BLOWDOWN PIPING. <br /> 'v. © CONNECT NEW 1"MCCWS TO WATER CHEMICAL TREATMENT • <br /> SYSTEM PANEL TO EXISTING 8"MCCWS HEADER. <br /> 6 CONNECT 3"MCCWS AND 3"PW TO EXISTING VALVES ON NORTH <br /> ' „ 14" PIPE RACK. <br /> - 3:;-6 VENT(BEHIND MCCWR) <br /> PNEUMATIC BYPASS <br /> -__ - VALVE CONNECT 14"GN2 TO EXISTING VALVE IN HEADER. <br /> 1 \� I 8 ACWR,TYP. 5 <br /> _ " ACWR 5"AC . APV VENT <br /> \ 6"MCCWR <br /> f 8 CONNECT 3/4"CA TO EXISTING VALVE IN HEADER. <br /> €I ! , , 3/4"CA 6"VENT 4 11111 3l4"CA <br /> I, 1 , / 1/2"CA a �.. 9 CONNECT 6"G EXISTING VALVE IN HEADER, <br /> -;,-- -'—'''I—: A, --..,f Z i',,:' , <br /> OA PROVIDE SPOOL PIECE IN PLACE OF DE PUMP.REFERTO P&ID <br /> `""" 1 �• -�`L -r��� _-� •may -j �0��i��a� - y ii4_ 4„ SHEET M336a-a.EXISTING SIDE STREAM FILTER(OSSF-700W)TO&10! ►� • <br /> u u ., CA REMAIN. <br /> I <br /> • 11: 1kiiOffAPv <br /> �,;�3AWINGS <br /> � REFERENCE DRAWINGS <br /> HOT WELL WEST CAP 20"AC <br /> WS <br /> (NOT USED) ,I SLOPE 6"MCCWR AT 1"PER 10' <br /> TOWARDS 36"COLLECTION PIPE <br /> LARGE RETURN DRAIN PIPE 2 <br /> SCALE: 1/4"= 1'-0" TN1M160-29a M535a <br /> i <br /> 0 8' 16' 24' 32' <br /> ,A.$0J :.;,N> 3/32"= 1'-0„ <br /> :VNI.,.fit G^F T. <br /> • <br /> 1 4� I ti \ ' 0 2' 4' 8' 12' <br /> iii <br /> II 1 <br /> inimmmi <br /> www.brph.corn Copyright 02018 44-'" ` ` 10_ <br /> 1/4"= 1'-0„ <br /> Architects Engineers,SW�� Inc. `.��o����cISTVc' w <br /> 002033rdAveW,Su?te Certiftete orAUCwrzMion ")- '''VONAL -V, `* <br /> <2SLynwood, <br /> Lt d,W JVd re No.633235512 �q ev_ •�2.e <br /> Engineering Na.3137 2 <br /> Q <br /> DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE 0 <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE r wgsH� ACCEPTABILITY JXK 10/09/18 AUTOCLAVE PIPING SECTIONS W2548317 1 10/09/18 M0 ISSUE FOR CONSTRUCTION JXK JLC 06/12/18 e oTHIS DESIGN AND/OR CHECKEDSHEETSPECIFICATION IS APPROVED JEW 10109/18 ao <br /> co <br /> RCHITECTS ENGINEER TITLE p® Boein 777X CWC BUILDING N1 REVISION RELEASE 101 ANP JLC 10109118 y Lz"A f --- ENGINEERS INC. APPROVED BY DEPT. DATE JLC 10/09/18 g IVI 5 3 5 a ` <br /> No3,3,- CHECKED BUILDING 40-58 <br /> _ ..._ <br /> `P�,F •c APPROVED JOB NO. COMP NO. 40-58-M535a x <br /> /c9TE OF AU1\'\- P APPROVED DWG NO, —� <br /> MECHANICAL MASTER EVERETT,WA 40-58-M535a <br />