fin_ r-•: '. a-- ,11 .0 0
<br /> 1 > 3 i LEGEND
<br /> SEE SHEETS 40-58-M1a-a,40-58-M1b-a,&40-58-M2a-a FOR KEY,
<br /> A A LEGEND,AND GENERAL NOTES,
<br /> •
<br /> GENERAL NOTES
<br /> 11
<br /> 3 � )� � 24"EXHAUST PIPE WITH 4" INSULATION TERMINATED 10'-0"ABOVE FACTORY
<br /> if;,, ROOF PARAPET.REFER TO SHEET M536a FOR INDUSTRIAL CAP DETAIL.
<br /> to
<br /> } I i © 4"EMISSIONS TESTING PORT WITH BLIND FLANGE,TYPICAL TWO PER STACK. •
<br /> I THE PORTS ON EACH INDIVIDUAL STACK SHALL BE SEPARATED BY 90°.
<br /> PROVIDE AT LEAST 2 0 OF SPACE DIRECTLY IN FRONT OF EACH PORT,
<br /> PROVIDE THE PORTS APPROXIMATELY 4'-0"ABOVE THE ROOF. INSTALL EYE
<br /> BOLTS ABOVE EACH PORT ON THE EXHAUST PIPE APPROXIMATELY 4'-0"
<br /> I------1 ABOVE EACH PORT.EYE BOLTS SHALL EXTEND BEYOND INSULATION.
<br /> I
<br /> El . 36" EXHAUST PIPE WITH 2" INSULATION TERMINATED 10'-0"ABOVE FACTORY
<br /> 205' 5 1/16"-FACTORY ROOF PARAPET \,k
<br /> 1 j ROOF PARAPET. REFER TO SHEET M536a FOR INDUSTRIAL CAP DETAIL.
<br /> I I Ir
<br /> 11
<br /> 4 20"COOLING TOWER WATER RETURN HEADER.
<br /> •
<br /> — = _ — MANUAL ISOLATION VAL
<br /> VE,TYP .
<br /> I i
<br /> 1 I I I 6 PNEUMATIC-OPERATED ISOLATION VALVE,TYP.
<br /> ;I 111
<br /> l
<br /> ' PS-CE-11 i 1 20"COOLING TOWER WATER SUPPLY HEADER.
<br /> 1I
<br /> PS-CE-21 IIW 11 8 TERMINATE DISCHARGE WITH GOOSENECK AND INSECT SCREEN OVER
<br /> 1--- -3° OPENING AT 10'-0"ABOVE BUMP OUT ROOF,TYP,OF(4) 1/2"GN2 BLEED
<br /> I PS GN 7 ' VENTS,
<br /> 1 9 6"VENT.TERMINATE DISCHARGE WITH GOOSENECK AND INSECT SCREEN
<br /> r - --_ --___--- . _!_ . OVER OPENING AT 10'0"ABOVE BUMP OUT ROOF.
<br /> i 10 EQUIPMENT,PIPING,ET THAT IS GREYED OUT EITHER EXISTING OR TO BE
<br /> QC. IS
<br /> i INSTALLED WITH SUBSEQUENT AUTOCLAVES AT A LATER DATE. REFER TO
<br /> I� (; ;-I I 1 ;
<br /> I I AUTOCLAVE SUBSYSTEM SCHEDULES FOR INDICATION OF INSTALLATION
<br /> 1 I 1 I PHASE.
<br /> ; l IOW PROVIDE GUIDEDSUPPORT PS-CE-10 iii
<br /> P VIDE FOR PIPING AT LOCATION INDICATED.
<br /> I PS CE 20 MINIMUM ® 4"VENT ISOLATION VALVE
<br /> 1 I I1! �. a1
<br /> i PS GN-6 I 10' —0 1/2" PROVIDE HAND LEVER ON OUTLET ISOLATION VALVE FOR BALANCING
<br /> ' ., (17) ® PURPOSES.
<br /> (C)
<br /> 1' ' I
<br /> _ -- - , ! I - 14 4"x6"GN2 SAFETY RELIEF VALVE, PROVIDED BY AUTOCLAVE VENDOR.
<br /> t
<br /> 1 6
<br /> 1" 7 1 6"GN2 SAFETY RELIEF PIPING WITH 8"THICK INSULATION FROM BUMPOUT
<br /> _I I - - ROOF UP TO 8'-0"ABOVE : MPIUT ROOF.
<br /> j ' € , - - 16 TERMINATE DISCHARGE WITH GOOSENECK AND INSECT SCREEN OVER
<br /> I ♦ Marley
<br /> I . i ...c..�. - _ 1 OPENING,TYP. OF(2)6"GN2 SAFETY RELIEF PIPES. .
<br /> � ' i I PS-CE-9 NW - -
<br /> I
<br /> i
<br /> LI
<br /> P E1 SC 9
<br /> 1a
<br /> I I PS-GN-5 �
<br /> _ il
<br /> CONSTRUCTION NOTES
<br /> I
<br /> i
<br /> r.__, �__r _L__ __ __ 11 (OPCT
<br /> T
<br /> _TIN 1 I L -- --- s - #
<br /> 1 < T I 840E
<br /> 0
<br /> , , T 1 ! �_ 1 , i '
<br /> II
<br /> I It I 1 III I I I I [ II
<br /> 1. ! i II _ •
<br /> E 1 i i ! PS-CE-8 11100. I - _11I
<br /> -
<br /> I
<br /> ' ' I
<br /> } PS-CE-18
<br /> PS-GN-4 I _
<br /> _ f i f r 9 `� _
<br /> f 1
<br /> fl
<br /> li p.,..,
<br /> 2
<br /> -77
<br /> I i 11 1- I k II
<br /> •
<br /> I I I
<br /> mum I I°
<br /> 1 1
<br /> I I 17 ,,i1,5 I
<br /> =1"i Min
<br /> 3 PS-CE-7 1PS-CE-17 III,
<br /> 1,3CA \ `I. — Ia;111111*
<br /> ® REFERENCE DRAWINGS
<br /> e..... 16 • i
<br /> •
<br /> I 1 PS GN 3II
<br /> 1 4"VENT ��
<br /> eIII Iih1iF 1 $ .,. .K 3
<br /> 20"CTWS .' Oii CTWR . AI I_ I
<br /> PS GNPSR1,2 51111
<br /> 1 1 I a 4 1
<br /> r`
<br /> I
<br /> = ii
<br /> « tIII� [Ill
<br /> ` i _.. -
<br /> TM.
<br /> 1 ' t. ;� c . ,sM� .::.^ �fi' _ �.., � ; .n .x4, ._ F _. -Nwr—. -*�" `" ? I LVL3
<br /> 1 1
<br /> I
<br /> .-
<br /> ir4 HI
<br /> 8 I 1 11.101 0
<br /> _ 1 , a 12 1oi CTWS 20"CTWR r •
<br /> E� ii
<br /> I 1 1 M ""„ -
<br /> Ia 9
<br /> ik
<br /> 1,1 flfl h_ t_
<br /> 1_
<br /> ___._ . -- I
<br /> ii LT
<br /> . r-Jr-J : . ,
<br /> i III
<br /> —
<br /> CI I
<br /> III
<br /> o
<br /> _:i 4— . . _ ©_ -- -0
<br /> I it
<br /> 141
<br /> lePROCESS COOLING TOWER WEST SECTION 2 , •
<br /> 1
<br /> _. ._ ____ — __ __ — SCALE: 1/4"= 1'-0" - 4 J ...,. -_. = - -- RFM160 3 a M539a
<br /> _�.AI. 17.-- asaaw.-
<br /> r` r r��'O WAS�� ..,
<br /> 14
<br /> 2 'h e _t I' i' /ljes o 0 2' 4' 8' 12'
<br /> f� �' 1 a s
<br /> SECTION — GASES UP BUILDING 1 "Y"y" -brpn.t 1 `� ' �°'$ 1477 ' ,•}> 1/4"= 1'-0"
<br /> Architects Engineers inc. ��� �°,� ��cr TEg�� �w�`�"��
<br /> SCALE: 1/4"= 1'-0" \ M539a 00203 Avew, 530icste ,fi:;Att000totoo
<br /> , �SSIo�aL E��� :*
<br /> No..3137 `
<br /> 2 •
<br /> DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE D
<br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE of WA ACCEPTABILITY JXK 09/11/18 AUTOCLAVE PIPING SECTIONS W2548317 2 09/11/18 N
<br /> 0 ISSUE FOR CONSTRUCTION JXK JLC 06/12/18 •<t- ti�o THIS DESIGN AND/OR CHECKEDU 09/11/18 SHEET
<br /> 5 2 SPECIFICATION IS APPROVED
<br /> BRPH ARCHITECTS ENGINEER TITLE
<br /> 1 REVISION RELEASE 98 ANP JLC 08/28/18 ENGINEERS INC.
<br /> co
<br /> ��� APPROVED BY DEPT. DATE JLC 09111/18 Boeing 777X CWC BUILDING o
<br /> ‘•
<br /> 2 REVISION RELEASE 99 ANP JLC 09/11/18
<br /> APPROVED JOB NO. COMP NO.
<br /> No.3ts7 CHECKED M539a (.1BUILDING 40-58 °'
<br /> Fic9JF OF AUjH� o APPROVED DWG No. 40-58-M539a
<br /> ' 40-58-M539a
<br />
|