Laserfiche WebLink
L <br /> 0 <br /> of <br /> P CO <br /> 5 _Aft <br /> ! ❑ A ❑ <br /> s COVERED DECK 15' <br /> • <br /> 4x6 POSTS W/A34 EA `• <br /> co m <br /> 6 SIDE TOP AND BOTTOM <br /> C0 HUCQ-STYLE HOLDOWN WITH 0 <br /> 1/4"x2-1/2 SDS SCREWS 0 <br /> / ` EN co 47' > < 50' > <br /> co co <br /> \ co <br /> 22' >< 14.-2" 10'-10" < 19' >-< 9' >-< 12' >< 10' > <br /> i. - u 1'-6" Y = „ <br /> 'K r <br /> 2'3 1/2" <br /> 3'6" 6' 6' 3" 4' —2' 3" 4' 3" 6' 3' 11" 6' 4 5' 2 6 _ ; 4' —2' �—3' 3' 5" 5' 3'_7" �_ _ 5' � -2-8 1/2 , <br /> 1111 <br /> M SW1 SW1 SW1 � SW1 f SW1 Sw1 SW1 SW1 SW1 J <br /> �© <br /> S�C,� 60610 4036LS 6040LS � ,t � rG��� '�� 60610 5040LS 2030SH 5040LS 5040LS p <br /> t <br /> nI n v \wv ❑ ,.y r �� -__ � y v v yv� v � � oy� <br /> R311.3.2 MIN LANDING 36 X 36 J Ol ® EGRESS WINDOW (::::5 <br /> T ° - Ll 3 1/8 X 10 1/2 GLB 24F V4 7-. o <br /> T • EGRESS WINDOW / 0 <br /> WITH 7 3/4" MAX RISE PER R 310.10 PER R-310.1 ' <br /> cv0 TO TOP OFTHRESHOLD <br /> R311.3.2 MIN LANDING 36 X 36 �� , / , <br /> a 5 . SAFETY ® WITH 7 3/4" MAX RISE / r I <br /> "' w I o `' TO TOP OFTHRESHOLD 50 CFM VTO j <br /> p< �? GLASS M FAN <br /> 50 CFM VTO b j' <br /> MS DINING N FANI ,-/ ALL EXT WINDOW AND DOOR -- -- - <br /> T I HDRS TO BE4X10DF#2U.N.O. I,. W <br /> Cg 100 CFM [. ;3'-2 1/2"-- 5'-9 1/I" <br /> 2 <br /> V <br /> - FAN VTO • LqW u N SMOKE ALARM -i N o cv <br /> f '. �. PER R314 so <br /> 'I.! ,.1 w � �� / - GAS WATER HEATER <br /> 50 CFM VTO WITH MIN EF OF 0.'9 / <br /> ALL EXT WINDOW AND DOOR - h � � \ o � � / <br /> HDRS TO BE 4X10 DF#2 U.N.O. �- J FAMILY FAN <br /> L "> c? / �I GAS FURNACE WITH �' <br /> coo < 2'-6' > ( --_--_-- --- ---- .—_-- -_ �' LAUNDRY co FURN MIN AFUE OF 94% / <br /> co <br /> MASTS BEDROOM �� <br /> SMOKE ALARM <br /> M prop PER R314 SD / <br /> \� , SMOKE ALARM <br /> \T V PANTRY r R807.1 -22X30 ATTIC PER 1 �° ' GARAGE <br /> co IACCESS. INSULATE < 5'5" 6'-9" I , R R3 4 ❑ LI- 9868 — / Z <br /> > AND WEATHERSTRIP. 3 6 R302.7- ENCLOSED ACCESSIBLE SPACE CARBON MONOXIDE J BOLLARD / <br /> 14.-41/2'° 3'-4" 4'-31/2" SW2 <br /> UNDER STAIRS SHALL BE PROTECTED ALARM PER R315.1 ,` �� 0 <br /> .- -_-- _ -- 5068 \\\\\ <\������� » ����-��L��_��L�\\�a����� WITH 1/2" GWB ON ALL ENCLOSED SURFACES. co <br /> 6068 V <br /> 5 <br /> T <br /> 1'4" RIDGE LINT OF VAULTED CEILING SW2 " SMOKE ALARM r o cZ. �a� j <br /> ED 1 PER R314 $__ 2868 Q / <br /> — — — — — \ 4X10 DF#2 5 1/8 X 9 GLB 24F V4 / <br /> 5 4X10 DF#2 �� �C cw / <br /> Co 2668 — — — — // \� — — — — co <br /> "' c�Q /� CARBON MONOXIDE FAN [Iji FAN I �, 0 <br /> N % 4X10 DF#2 `5 1/2`, 4' 0 1/2" s SW2 WATER HEATER SHALL BE �` bo <br /> 2468 6068 \ _ 50 CFM VTO CO N fl <br /> ALARM PER R315.1 c� cv / BRACED PER P2801.7 co <br /> 6068 �� ` 1 3/8" SOLID CORE WOOD DOOR WITH RELIEF VALVE PER P2803 a a <br /> gl <br /> 1 FAN - \ �- _ /" C // e' OR 20 MINUTE FIRE RATED DOOR "' <br /> N rJ❑ = 1 2668 _ 2668 _ - _:T _ __ _ <br /> - — VTOER 50 CFM VTO E, / y_ 2G8$ WITH SELF CLOSER PER R302.5.1 <br /> ®N - — ✓ _� 1� _- - UP e R302.6- PROVIDE 1/2" DRYWALL ON WARM WALLS, ;� <br /> ZERO CLEARANCE GAS — —\ ` 60687'-6" 4'-2 1/2" T 3'-10 1/2"— 3'-5" SUPPORTING VVALL S AND GARAGE TO ATTIC. <br /> F PROVIDE 5/8" TYPE X GWB ON CEILINGS 3.. ' .y G ?.�S$ d <br /> FIREPLACE, INSTALL PER �\\�/ \/- <br /> \ / ;� .�y ,�r��c <br /> °B MFG SPECS r MIN 18X24 CRAWL SPACE j WITH HABITABLE ROOMS ABOVE 6X6 POST WITH AB AND AC <br /> 6068 WHOLE HOUSE FAN PER 0 ACCESS. INSULATE AND CONNECTORS <br /> / <br /> = WEATHERSTRIP. R408.4 <br /> M1507.3 W/24 HR MT <br /> a <br /> SST LIVING `� ;?5SONERATNG. V OAND 5 1/8 X 16 1/2 GLB 24F V4 <br /> \© < - — _ T_8" 1'2:'- 3' 6"�E, 4' _< l d0 8, 8„ BEDROOM 4 — — — — <br /> M1307.3 APPLIANCES HAVING AN IGNITION u) <br /> 1 OPEN TO BELOW SMOKE ALARM s� ��®R��M �, SMOKE AL_.ARM j — — SOURCE SHALL BE ELEVATED SUCH THAT <br /> PER R314 ❑ N so u) THE SOURCE O <br /> PER R314 / F IGNITION !S NOT LESS THAN <br /> `" sT // 18 INCHES ABOVE THE FLOOR IN GARAGES. <br /> q SMOKE ALARM ti0 0 I , <br /> M,9T05,0 <br /> SAFETY PER R314 SD ,VI,`; ( M1307.4.1.1 - (2) SCREENED COMBUSTION <br /> V GLASS — / J - EGRESS WINDOW - AIR DUCTS ARE REQUIRED IN FURNACE <br /> 1 1 BEDROOM ` PER R-310.1 AY AND WH ROOM. ONE WITHIN 12" OF TOP <br /> �� �� p� r — ©q p< / f PLATE AND ONE WITHIN 12" OF FLOOR. <br /> I <br /> ��`, J o �p� 3068 2050FX EGRESS WINDOW ba • _ o �p j <br /> PER R-310.1 - I GARAGE I 5 1/8 X 10 1/2 GLB 24F V4 u) <br /> 5050LS CO EGRESS WINDOW 5040LS - / I <br /> 4.) E' A PER R-310.1 7_\\�\\\ �n o ® — 1, / I - - - - - L.., <br /> V ,®\\A G ,X)0._ �\ V I 5040LS 1_ �w 1 ,ems \c��I N <br /> 8080 0 <br /> 4040LS /7 �-Y — 4X12 DF#2 ' N Z <br /> ❑ V 1 I SW1 SW1 SW1 SW1 V V �V� Q— — — — — — _ ❑ \r V <br /> ! <br /> 5 1/4" 5 1/4" 1 2 1/ " IC 2' 11 1/2" — = ® 16080 re <br /> 5' - ---->-< 3' >.6,0—2, > 9"` _ 4' 3'-10" < 3'-9" >j< 5' >, 3'-11" 55 <br /> 1'-4" 1' 2 - 1 1'-6 1/2" 51/4" 51/4" <br /> �� ' :< 5'-10 1/2" ��2' ;8"— —7'=5 1/2" ;< 10'-9 1/2" >,< = 12'-8" >< 3' > —< 5' 2'-6„�< 16' 2'-6" Y1 8' —1� " <br /> 48'-4" « 2' 5'-10 1/2" >-< 2'- -10" 7'-3 1/2" ;< 21' 0 <br /> ee <br /> 50' > ` . <br /> UP UPPER FLOOR PLAN <br /> SCALE 1/4"=1 FT LOWER FLOOR PLAN 0 <br /> SCALE 1/4"=1 FT <br /> D re <br /> 03 E <br /> CITY OF EVE:f, ETI <br /> ❑E`V E Q ED FOR PERq 0,?T DATE: <br /> N <br /> 1 UPSTATE ENGINEERING 3/11/2020 <br /> PO BOX 952 <br /> LYNNWOOD, WA 98046 <br /> 206-280-4715 1 EHD JOB: <br /> STRUCTURAL REVIEW <br /> THIS DRAWING HAS BEEN 2388 <br /> REVIEWED FOR STRUCTURAL <br /> 4 REQUIREMENTS ONLY PER THE - - <br /> I ATTACHED LETTER/CALCULATIONS <br /> __ PROVIDED BY THIS OFFICE. SHEET: <br /> REVIEWED BY: am9 <br /> I DATE:- /11/20 JOB#1166 2 <br />