Laserfiche WebLink
I a+-ic,y i r+ures EXIST. HEADER I <br /> 1" ATERIAL SPECIFICATIONS: MATE R1AL SPECIFICATIONS (CONT.): o <br /> VINYL SIDING o <br /> ,- J <br /> EXIST. EXTERIOR WALL SIMPSON EPC6Z I THE EXISTING VINYL SIDING IS TO BE CAREFULLY REMOVED AND STORED FOR RE-USE. IF <br /> I 1 SHEATHING AND PANEL THE VINYL SIDING IS DAMAGED DURING REMOVAL AND RE-INSTALLATION, NEW VINYL <br /> NE MATERIAL SPECIFICATIONS ARE PRESENTED IN A SHORT FORM FORMAT. THE <br /> SIMPSON A35 CLIP I CONTRACTOR AND/OR SUBCONTRACTORS(S) SHALL INSTALL THE PRODUCTS IN <br /> EXIST. FLOOR EDGE NAILING ACCORDANCE WITH THE FOLLOWING CURRENT EDITION OF INDUSTRY STANDARDS AND SIDING SHALL BE INSTALLED TO MATCH THE EXISTING. THE NEW VINYL SIDING SHALL BE <br /> JOIST COPES IN NO PARTICULAR ORDER: INSTALL FROM TOP TO BOTTOM AND CORNER TO CORNER SO THE COLOR WILL MATCH. <br /> REMOVE AND REUSE EXIST. A. REVISED CODE OF WASHINGTON (RCW) RE-INSTALLED AND NEW VINYL SIDING SHALL SE INSTALLED IN ACCORDANCE WITH THE <br /> SIMPSON MST31 (PER �� B. INTERNATIONAL BUILDING CODE (IBC) VINYL SIDING INSTITUTE'S INSTALLATION RECOMMENDATIONS. <br /> EXIST. RIM JOIStI �� ORIGINAL DRAWINGS ON C. CITY OF EVERETT MUNICIPAL CODE THE NEW VINYL SIDING SHALL MATCH THE EXISTING TEXTURE, SHAPE AND COLOR AS <br /> SHEET 52.0) IF PRESENT D. NATIONAL ROOFING CONTRACTORS ASSOCIATION (NRCA) CLOSE AS POSSIBLE. PROVIDE SAMPLES TO PACIFIC ENGINEERING TECHNOLOGIES, INC. <br /> EXIST. HEADER TO E. SHEET METAL AND AIR CONDITIONING NATIONAL ASSOCIATION (SMACNA) AND THE HOA FOR REVIEW AND APPROVAL PRIOR TO PURCHASE AND INSTALLATION. <br /> REMAIN, PROVIDE F. MANUFACTURER'S PRODUCT INSTALLATION RECOMMENDATIONS <br /> TEMPORARY SUPPORT + EXIST. STUD WALL . G. THESE REPAIR DOCUMENTS <br /> t0 REMAIN n <br /> + �, � � > EXTERIOR PAINT: <br /> BUILT-UP P.T. HEADER + THE CONTRACTOR SHALL SUBMIT PROPOSED PRODUCT DATA SHEETS TO PACIFIC A. SHALL BE A HIGH QUALITY EXTERIOR GRADE 100% ACRYLIC LATEX PAINT, UNLESS c <br /> COLUMN ' ENGINEERING TECHNOLOGIES FOR REVIEW AND APPROVAL PRIOR TO PURCHASE AND OTHERWISE RECOMMEND BY PRODUCT OR PAINT MANUFACTURER <br /> INSTALLATION. B. PROVIDE THE APPROPRIATE PAINT TYPE FOR THE SUBSTRATE THE PAINT IS TO BE <br /> SIMPSON A34 CLIP EA. V APPLIED TO.SIDE OF BUILT-UP + Io <br /> WEATHER RESISTIVE BARRIER (WRB) / AIR BARRIER: C. PROVIDE A 12" BY 12" SAMPLE OF COLOR FOR REVIEW AND APPROVAL BY PACIFIC Z <br /> COLUMN + SHALL BE ONE OF THE FOLLOWING: ENGINEERING TECHNOLOGIES, INC. AND THE CONDOMINIUM OWNERS' ASSOCIATION <br /> + I PANEL EDGE NAILING PRIOR TO PURCHASE AND APPLICATION. <br /> EXIST. P.T. BOTTOM + � • FORTIFIBER WEATHERSMARt COMMERCIAL WRAP D. PREPARE SURFACES AND APPLY PAINT AS RECOMMENDED BY MANUFACTURER 0 <br /> PLATE TO REMAIN -� 1 • VAPROSHIELD WRAPSHIELD �„ <br /> A. NE SYSTEM IS TO INCLUDE ALL, ASSOCIATED ACCESSORIES AND ATTACHMENTS. CNI <br /> THE PAINT SHALL HAVE A 15 YEAR WARRANTY. 60 <br /> BUILT-UP P.T. 2x B. • <br /> SEAL ALL LAPS AND SEAMS WITH MANUFACTURER'S PROVIDED TAPE AND/OR DOW <br /> IL i --- . <br /> COLUMN PER PLAN CORNING �58 SILICONE WEATHER BARRIER SEALANT IN ACCORDANCE WITH <br /> TO MATCH EXIST. SEALANTS: al III III-III III TOGETHER WITH 10d MANUFACTURER'S RECOMMENDATIONS, A. CLEAN ALL SURFACES PRIOR t0 APPLICATION OF SEALANT. 0 4 r o r a <br /> - COMMON NAILS AT C. THE EXTERIOR WEATHER BARRIER / AIR BARRIER SYSTEM SHALL HAVE A 10 YEAR o -i o V zs u a -- <br /> III—III III— 6" O.C., EA. SIDE MANUFACTURER WARRANTY. B. TOOL ALL SEALANT JOINTS. <br /> III—III D. INSTALL IN ACCORDANCE WIN MANUFACTURER'S RECOMMENDATIONS. C. SEALANT SHALL BE APPLIED IN ACCORDANCE WITH THE SEALANT MANUFACTURER'S <br /> PROVIDE TEMPORARY E. WRB SHALL BE INSTALLED IN WEATHER BOARD FASHION WITH NE UPPER LAYERS WRITTEN INSTRUCTIONS AND ASTM C 1193. CONTRACTOR SHALL VERIFY SEALANTS <br /> -1 I I—III III—III SUPPORT OVERLAPPING THE LOWER LAYER AS RECOMMENDED BY THE MANUFACTURER SEAL ARE RECOMMENDED BY MANUFACTURER TO USE, AND IS COMPATIBLE WIN, ALL <br /> ALL LAPS WIN A BEAD OF DOWSIL 158 SILICONE WEATHER BARRIER SEALANT. BUILDING COMPONENTS. <br /> co <br /> NOTE: VERTICAL LAPS SHALL BE STAGGERED 24" MINIMUM AND NOT PLACED ABOVE D. USE A PRIMER APPROVED BY NE MANUFACTURER OF THE SEALANT BEING USED. — <br /> ' 2 FLOOR FRAMING NOT WINDOW OR DOOR OPENINGS. PROPERLY INTEGRATE WITH OTHER WEATHER E. SEALANT JOINTS SHALL HAVE (2) RANDOM FIELD ADHESION TESTS FOR EACH TYPE <br /> SECT ION SECT ION SHOUJN RESISTIVE BARRIER AND FLASHING ASSEMBLIES IN WEATHER BOARD FASHION. OF JOINT SUBSTRATE PERFORMED BY AN AUTHORIZED PRODUCT REPRESENTATIVE. cI <br /> SCALE: 3/4" = i'-0" SCALE: I 1/2" = 1'-0" THE CONTRACTOR SHALL PROVIDE THE WRITTEN REPORT RESULTS TO PACIFIC o <br /> SELF ADHESIVE FLASHING (SAF): ENGINEERING TECHNOLOGIES, INC. FOR REVIEW o §N <br /> SHALL BE ONE OF THE FOLLOWING BUTYL SELF-ADHERED FLASHINGS: = ^N <br /> • GRACE VYCOR PRO TRIM SEALANT JOINTS: w co'-' <br /> • PROTECTO BT20XL BUTYL c� to <br /> • FORTIFIBER FORTIFLASH BUTYL 30 MIL. SHALL BE AN EXTERIOR GRADE HIGH PERFORMANCE SINGLE COMPONENT <br /> POLYURETHANE PAINTABLE JOINT SEALANT COMPLYING WITH ASTM C 920, GRADE NS, <br /> • OTHER APPROVED EQUIVALENT BUTYL SELF-ADHERED FLASHING CLASS 25 OR HIGHER. w <br /> I z <br /> I EXIST. WALL FRAMING APPROVED SEALANTS: <br /> AND BATT INSULATION MISCELANEOUS PENETRATION FLASHING PANELS: o <br /> FOR MISCELLANEOUS ELECTRICAL, •BASF MASTERSEAL NP-150 N Qf <br /> I PLUMBING AND MECHANICAL PENETRATIONS, PROVIDE •TREMCO DYMONIC 100 0 <br /> PLYWOOD SHEATHING PER QUICKFLASH FLASHING PANELS MANUFACTURED BY QUICKFLASH WEATHERPROOFING NM <br /> PLAN PRODUCTS, INC. NE FLASHING PANEL SHALL BE SIZED APPROPRIATELY FOR THE •SIKA SIKAFLEX 15-LM co <br /> INTENDED PENETRATION. •OR APPROVED EQUIVALENT N <br /> VINYL SIDING, REF. o <br /> NEW O EXIST. 2x <br /> ELEVATIONS E R E FLUID APPLIED FLASHING: (ti <br /> ' <br /> WRB SEALANT: o <br /> LAP CONT. U1RB OVER FLASHINGS AND SEAL A. SHALL BE PROSOCO / R-GUARD, LIQUID FLASHING MEMBRANE SYSTEM. THE SYSTEM �3 <br /> CONSISTS OF THE FOLLOWING: SHALL BE COMPATIBLE WIN AND ABLE TO ADHERE TO THE WRB. <br /> - Z� • JOINT AND SEAM FILLER APPROVED SEALANTS: <br /> COUNTERFLASH METAL �`' I( • FASTFLASH •DOW CORNING 'i58 N 05 <br /> FLASHING 2" MIN. WITH _ 1/2" • POROUSPREP •OR APPROVED EQUIVALENT <br /> FASTFLASH Z B. THE FLUID FLASHING MEMBRANE IS TO BE INSTALLED SUCH THAT THE UNDERLYING <br /> - — PREFfNiSHED HEAD FLASHING SUBSTRATE THAT THE FLUID FLASHING IS APPLIED TO, IS NOT VISIBLE AFTER <br /> I lx TRIM PIECE APPLICATION. BACKER ROD: a <br /> N I — _ ��� — — A. ALL BACKER RODS SHALL BE HBR CLOSED CELL BACKER ROD MANUFACTURED BY C. WHERE FLUID FLASHING MEMBRANE IS TO BE INTEGRATED WITH THE WRB, VERIFY THE <br /> / r-, {LAP CONT. WRB OVER FLASHINGS AND SEAL — �— — — — — — ! ADHESION COMPATIBILITY WITH THE MANUFACTURER PRIOR TO PROCEEDING. NOMANCO. N <br /> FASTFLASH 12 UP STAINLESS STEEL METAL BASE OF WALL FLASHING SET IN D. USE POROUSPREP ON EXPOSED EDGES OF GYPSUM SHEATHING PRIOR t0 B. THE DIAMETER OR WIDTH SHALL BE AS RECOMMENDED BY MANUFACTURER FOR THE <br /> l 4s, .--. <br /> WALL SHEATHING AND I SAWCUT GROOVE IN CONC. FILLED WITH SEALANT EX(St. W000 GARAGE JAMB APPLICATION. SPECIFIC OPENING TO RECEIVE SEALANT. WHERE BACKER RODS ARE TO TURN 90 �4 `& <br /> ONTO CONC. 1" SET FLASHING BEFORE SEALANT SKINS OVER WRB) TO REMAIN IN PLACE DEGREE CORNERS THE SACKER ROD SHALL TERMINATE AT CORNER AND A NEW <br /> J J PLYWOOD SHEATHING METAL FLASHINGS: PIECE OF BACKER ROD WILL CONTINUE IN NE NEXT DIRECTION. ALLOW NE At R 8 <br /> = ['EXIST. CONC. BACKER ROD TO REST (APPROXIMATELY 30 MINUTES) BEFORE APPLYING SEALANT. '�,+r <br /> /� CONT. 1/2" WIDE BACKER ALL METAL FLASHINGS SHALL MEET THE FOLLOWING SPECIFICATIONS: p.► o itNEW FASTFLASH EXTEND ROD AND SEALANT JOINTC. IF BACKER ROD CANNOT BE USED IN A PARTICULAR SITUATION, BOND BREAKING • <br /> ONTO WALL SURFACE 9" A. METAL FLASHING TO BE 24 GAUGE (UN.O.). TAPE SHALL SE USED TO PREVENT THREE-SIDED ADHESION. INSTALL BACKER c$ ��� <br /> AND ONTO GARAGE EXIST. VINYL SIDING TO SE B. ALL METAL FLASHINGS ARE TO BE G90 GALVANIZED (UN.O.) RODS PER MANUFACTURER'S RECOMMENDATIONS. wc� 4416,. <br /> TRIM 1/2" REMOVED AND RE-INSTALLED C. UNFINISHED FLASHINGS IN CONTACT WIN CONCRETE ARE TO BE STAINLESS STEEL <br /> (U.N.O.) WOOD TRIM: 4., <br /> D. ALL VISIBLE METAL FLASHINGS SHALL BE PRE-PRIMED OR BONDERIZED METAL, SHALL BE PREPRIMED TIGHT KNOT CEDAR. PRIME ALL CUT ENDS WITH (2) COATS OF <br /> PAINTED TO MATCH THE EXIST. COLOR SCHEME. EXTERIOR GRADE PRIMER PRIOR TO INSTALLATION. <br /> 1/2" WIDE BY 3/4" DEEP SAWCUT GROOVE. E. COLOR SAMPLES SHALL BE SUBMITTED AND APPROVED BY PACIFIC ENGINEERING <br /> CLEAN KERF AND FILL WITH SEALANT TECHNOLOGIES, INC. AND THE HOMEOWNERS' ASSOCIATION. <br /> F. ALL JOINTS ARE TO BE SOLDERED, UNLESS NOTED OTHERWISE. GENERAL NOTES: <br /> f /� G. HEM ALL EXPOSED EDGES. ILI <br /> A. CONTRACTOR SHALL VERIFY ALL PRODUCTS AND MATERIALS ARE COMPATIBLE <br /> BLS OF WALL ,�T CONC. � � DOOR Jf-�t5 H. METAL FLASHINGS SHALL BE FORMED FROM THE LONGEST SECTIONS POSSIBLE t0 W(tH EACH OTHER PRIOR TO INSTALLATION. <br /> SCALE. 3 -i -0 MINIMIZE JOINTS. 0 <br /> SCALE: 3" I'-0" I. ALL HEAD FLASHINGS ARE TO BE ONE-CONTINUOUS PIECE U.N.O. AT HORIZONTAL B SUBSTITUTEDCONTRACTOR MAY MATERIALS SIMILAR <br /> TUTED MATER ALLSSHALL BE APPROVED BY P CIF MATERIALS. <br /> ENGINEERING Z <br /> PANEL JOINTS. TECHNOLOGIES, INC. PRIOR TO PURCHASE AND INSTALLATION. <br /> J. SHOP FABRICATE ALL FLASHINGS TO THE GREATEST EXTENT POSSIBLE. C. ALL PRODUCTS AND MATERIAL SAMPLES, INSTALLATION RECOMMENDATIONS AND l.-1 <br /> i \ K. FLASHINGS TO HAVE MINIMUM 6" VERTICAL LEGS AND 4" HORIZONTAL LEGS (UN.O.) SPECIFICATIONS SHALL SE SUBMITTED TO PACIFIC ENGINEERING TECHNOLOGIES, INC. Z <br /> L. SET ALL FLASHINGS IN SEALANT (REFERENCE SEALANTS SECTION). FOR APPROVAL PRIOR TO PURCHASE AND INSTALLATION. <br /> N. <br /> LAP WRB OVER FLASHING AND SEAL D. COLOR SAMPLES OF ALL PRODUCTS SHALL BE PROVIDED AND APPROVED BY <br /> M. ALL LAPS/SPLICES WITH OTHER FLASHINGS ARE TO BE 6" MINIMUM SET IN (3) 3/8" <br /> I CONT. BEADS OF SEALANT PARALLEL TO EDGE OF FLASHING, TYPICAL ALL METAL PACIFIC ENGINEERING TECHNOLOGIES, INC. AND THE CONDOMINIUM OWNERS' <br /> I WRB TARGET FLASHING FLASHINGS (REFERENCE SEALANTS SECTION). ASSOCIATION PRIOR TO PURCHASE AND INSTALLATION. Z <br /> N. PROPERLY INTEGRATE WITH OTHER WEATHER RESISTIVE BARRIER AND FLASHING E. CONTRACTOR IS TO FOLLOW MANUFACTURER'S APPLICATION RECOMMENDATIONS FOR 0 <br /> I SHINGLE 6" WIDE SAF OVER COLD WEATHER WHEN TEMPERATURES ARE BELOW 40% CONTRACTOR IS TO <br /> QUICKFLASH JAMB AND HEAD FLANGES A8SEMBLI IN WEATHER BOARD FASHION WITH 6 MINIMUM VERTICAL LAPS/SPLICES PERFORM AN ADHESION TEST FOR ANY QUESTIONABLE SUBSTRATES. <br /> AT HEAD, LAP WRB AND 3" MINIMUM HORIZONTAL LAPS/SPLICES. I— <br /> I OVER FLASHING / O. PROVIDE SEPARATION (SUCH AS A LAYER OF SAF) BETWEEN DISSIMILAR METALS TO c U <br /> AND SEAL / PREVENT GALVANIC ACTION (CORROSION). cu <br /> LU <br /> P. FABRICATION AND INSTALLATION OF METAL FLASHINGS IS TO TAKE INTO ACCOUNT 8 <br /> 'WRB TARGET <br /> I FLASHING I PREFINISHED HEAD FLASHING WITH EXPANSION AND CONTRACTION TO AVOID BUCKLING AND/OR OIL CANNING. <br /> 1.......... SEALED END DAM Q. UNDERBREAK OR OVERBREAK FLASHINGS TO PROVIDE A TIGHT FIT. 4 <br /> PREFINISHED METAL R. THE CONTRACTOR SHALL PROVIDE MOCK-UPS OF METAL FLASHINGS FOR APPROVAL <br /> 1 END DAMS FLASHINGHEAD WITH I , BY PACIFIC ENGINEERING TECHNOLOGIES, INC. PRIOR TO FINAL FABRICATION AND 4 1 <br /> I r 1/2 INSTALLATION. <br /> i/ 1/2" A S. METAL FLASHINGS SHALL BE IN ACCORDANCE WITH SHEET METAL AND AIR W <br /> / CONDITIONING CONTRACTORS NATIONAL ASSOCIATION (SMACNA) u1 <br /> ARCHITECTURAL SHEET METAL MANUAL. <br /> SET HOSE BIB QUICKFLASH WALL FLASHING FOR <br /> FASTENERS IN SEAL SHEATHING —i', ELECTRICAL PENETRATION 0 <br /> PREDRILLED HOLES PENETRATION // U <br /> FILLED W/ SEALANT y 1-� AROUND / , ` <br /> ELECTRICAL BOX (EXTERIOR FIXTURE U <br /> r .4 <br /> n <br /> APPLY BACKER '�- �� , ILI !J_. <br /> ROD AND SEALANT ) C oPROVIDEAROUND PIPE � UNDER FI TURAETHER GASKET n f <br /> PENETRATION TYP. �0ILI <br /> I EXIST. •HOSE BIB `' f I FIXTURE BLOCK W <br /> FLUID APPLIED APPLY CONT. 3/8" FILLET BEAD OF SEALANT T L.- <br /> FLASHING AROUND AND ( SQUARE U <br /> ONTO PIPE I" AND I WARP IETRIM AND BACKER ROD AT SIDES AND BOTTOM 0 <br /> EXTEND 9" BEYOND BLOCK .6 Ui 2 IY <br /> WRB TARGET FLASHING .o tn <br /> PIPE. LAP OVER WRB / I 5425 . APPLY CONT. 3/8" FILL M <br /> TARGET FLASHING <br /> BEAD OF SEALANT ANI / EXIST. VINYL SIDING <br /> I BACKER ROD AT SIDE / '` <br /> WRB TARGET FLASHING I I AND BOTTOM <br /> I EXIST. VINYL SHINGLE WRB BEHIND BOTTOM <br /> SIDING OF QUICKFLASH PANEL AND <br /> WRB TARGET FLASHING 2 <br /> N SHINGLE WRB BEHIND _ <br /> OF QUICKFLASH PANEL ALL INFORMATION ON THIS DOCUMENT <br /> WRB TARGET FLASHINC IS THE EXCLUSIVE PROPERTY OF a <br /> HOSE 315 5 EXTERIOR OUTLET/ F I XTURE 6 PACIFIC ENGINEERING TECHNOLOGIES, INC. 2 <br /> 3/17/2020 HALF SCALE SCALE: 3" = I'-0" <br /> © COPYRIGHT 2020 <br /> 20032 WD 01.dwg Job No. 20032.00 <br />