|
— - 1
<br /> . ,
<br /> (N) 24 GA, PRE-FINISHED METAL
<br /> (E) BARRIER EIFS TO REMAIN COPING
<br /> BETWEEN AWNING SOFFIT . ,
<br /> I\ AND STOREFRONT f-lEAD (E) F.T. WD NAILER TO REMAIN,
<br /> n , .
<br /> SHIIVI AS REO.D. FOR SLOPE
<br /> 0 ' ,
<br /> GASKETED SCREWS CI), 24" 0.0.
<br /> --- TRANSITION MEMBRANE ONTO FA
<br /> ' , \ '----77-1 1 THROUGH SLOTTED HOLES ,
<br /> WRB AT OUTSIDE
<br /> [ 1 ____-------------- (N) EIFS FINISH COAT OVER
<br /> oF METAL CLADDING AT INSIDE ,
<br /> 1 r EXISTING FINISH COAT FACE
<br /> _, ------ EXTERIOR SHEATHING \ ---------- _ ,-,-----7-..---7----7-1 '
<br /> I-,-,..1
<br /> 1 1
<br /> 'C'0 IA 1 1 1
<br /> I
<br /> ..,_,. _ =-'- 4 11 11 N,
<br /> 1 1 i 1 r i/ o ..
<br /> 1
<br /> i ,
<br /> CONT CLEAT
<br /> \ , RESTORE BOTTOM EDGE OF li ' N
<br /> '
<br /> : / EIFS AS REO.D. AFTER i'-
<br /> , Lli , \
<br /> \ SEALANT FILLET w/BACKER ROD ' ----7
<br /> 1 I REMOVING (E) SEALANT
<br /> '''F---
<br /> )
<br /> -
<br /> _ --/ -UCi,u,
<br /> 1 , - ---
<br /> -,, ,—,-,, f----,-,--0--, --
<br /> -,..,_
<br /> ,---- FA DETAIL FLASHING, LAP ONTO —
<br /> —1 ."--...,,,,
<br /> ,-, 1 WOOD NAILER TURNING UP
<br /> - v,...NN '..„ W
<br /> .! ----_, OVER TOP.
<br /> '' (N) SEALANT JOINT \iv/ BACKER
<br /> ,
<br /> I ------------
<br /> F,
<br /> ----_____
<br /> NN, ROD
<br /> i ;
<br /> .--' ,,,]
<br /> 1:--------- -----__ FA WRB
<br /> 1\ 1 1 ,
<br /> _ I . -----......,_,._ 1, 1 ,.. .
<br /> \ \.,,,
<br /> STOREFRONT SYSTEM Al
<br /> v
<br /> „ — PRE-WAPPED 2 - INCH INSULATION : ,,,.,i
<br /> c0 ,
<br /> LOWER LEVEL ROTUNDA TO
<br /> . BOARD . ., ' --,.., cd,---
<br /> REMAIN IN PLACE
<br /> .---- DRAINAGE EIFS, INSTALL PER
<br /> MANUFACTURER'S WRITTEN
<br /> RECOMMENDATIONS — LA RI — , •
<br /> \ STOREFRONT HEAD AT LOWER LEVEL ROTUNDA
<br /> r-----
<br /> SS ----, -- .,,„,,
<br /> SECOND FLOOR DECK PARAPET r,
<br /> • -...,. _ ,-. EY_ (f) ,: .
<br /> SC
<br /> \ CALE: NT ALE: NTS
<br /> - _
<br /> 1.----
<br /> .,...- STANDING SEAM, TYP. 1
<br /> L ''---
<br /> EU
<br /> ---- ----
<br /> -,---"-------"----- ..----------- -0----, rt- „._
<br /> •, „-,,,,
<br /> :- --.,_
<br /> (E) STOREFRONT TO REMAIN IN „•;.._, „,, -',...,, -
<br /> cp
<br /> PLACE ---...---, --,„
<br /> ------- ----- -,, CD
<br /> I '
<br /> _--_ 4x4 PRE-FINISHED ANGLE SET -,.:‘,,,
<br /> --,,,--
<br /> ----____ , it il.',,, 4,1-!,i, NI:
<br /> 7- -
<br /> TIGHT TO END OF SHEAHTING "---..
<br /> -4
<br /> ET SI
<br /> / 7, ./XF—RIO V HEATHNG/ ZZ
<br /> 0
<br /> 7i-
<br /> ,
<br /> .._ .__
<br /> y/V v OA 1 _
<br /> \ -----,,---,
<br /> we,
<br /> _.}-2 . 2 _A___ ._ _},1,1- —)--, \ i,, :, d >
<br /> '--- i.- ';--- [-; \ ---. ,
<br /> -,
<br /> -, .. r- Lortlsi
<br /> ,4,,,s., ----
<br /> . , -, 1-0 LO
<br /> -,,___ ___ -1 CO IX) 0
<br /> q.-.H N
<br /> K
<br /> . ,-4 -!..•',t,,,,, - w (NJ C\I -
<br /> ,.. .
<br /> . ' .`',;• ' 11 '"vs_ . ----s' \ I
<br /> ''''',, ', 111N '-',...„,,_ , \•
<br /> \ ., ..,,,,,--
<br /> ' ,•',..S.,. UN,- cj ._.,
<br /> \' ' --- ' -----„,
<br /> , 1--- ---T1 I- ,.: &:,,,,,.0..„4,,,
<br /> -.,;-,.-,,,,,,,, -..i,
<br /> ,2,4 , I i ________T
<br /> . '-7- -Z,.'''',.7'
<br /> N,..., '•-..
<br /> y, " SEALANT JOINT ,,,
<br /> --,., FACE OF METAL 1 -,,,,.. ..4., Ci W
<br /> '',. w/ BACKER
<br /> ---„7, COPING
<br /> N PRE-WRAPPED INSULATION BOARD, ,,,..
<br /> --,. .`-‘,,, , ." ' a ,Il A A ' IX'
<br /> --,. TYP. ',., ' IVA)1, 4 - A ,,s--- - ---
<br /> --.., ,
<br /> SEALANT JOINT
<br /> '.- 2 '
<br /> ''''' DRAINAGE EIFS, INSTALL, PER -,,,,, w/BACKER ROD 3
<br /> en ... I . ,
<br /> MANUFACTURER'S WRITTEN ,-,.. ' '
<br /> RECOMMENDATIONS, TYP, ---,,,,
<br /> ------\A--
<br /> KEW' DETAIL
<br /> - ------,
<br /> STOREFRONT JAMB AT LOWER LEVEL ROTUNDA HVAC SCREEN COPING CAP AT FLYING BEAM
<br /> SCALE: NTS Gi Z.:3CALE: NTS
<br /> STOREFRONT TI_Ii16. 12.,,T
<br /> BACK DAM \
<br /> SHEET NOTE. FOLLOW EIFS MANUFACTURER'S WRITTEN INSTALLATION .
<br /> INS'FRUCTIONS FOR ALL EIFS INSTALLATIONS. NOTIFY ARCHITECT/ENGINEER OF1 ONTO FLASHING BOOT — FULLY WELDED SS
<br /> DISCREPANCIES BETWEEN MANUFACTURER'S INSTRUCTIONS AND DETAILS HERE. SET IN SEALANT FLASHING BOOT TO BE
<br /> SHOWN IN DRAWINGS, AND SEEK CLARIFICATIC)N BEFORE PROCEEDING WIT H
<br /> & RIVET SILL PAN TO
<br /> , _jN
<br /> — \\N:N,
<br /> NN
<br /> SET UNDER
<br /> STOREFRONT 2019-04-18
<br /> ASSEMBLIES w/CHANGE BID SET
<br /> Ill SILL HEIGHT & CONSTRUCTION SET
<br /> INSTALLATION. BOOT /
<br /> 2019-04-08
<br /> VERTICAL ANGLE OF
<br /> WALL PLANES
<br /> NN .
<br /> ----
<br /> / \\N 019 OAC SE COPYRIGHT VICES
<br /> 2019-0418
<br /> ,D.2R ,INC.
<br /> THESE DOC WJENTS,THE IDEAS AND DESIGNS INCORPORATED
<br /> ---------._- ....-- \ HEREIN AS AN INSTRUMENT OF SERVICE,ARE THE PROPERTY OF ,
<br /> \---- STOREFRONT SILL PAN OAC SERVICES,INC.AND ARE NOT TO BE USED IN WHOLE OR IN
<br /> N. PART WITHOUT WRITTEN AUTHORIZATION OF OAC SERVICES,INC.
<br /> „ DETAIL 12/A5.11 "AT
<br /> _„-------___
<br /> NN SILL" TO LAP ONTO
<br /> N
<br /> DESIGN DS/GYWDKt
<br /> , FLASHING BOOT HERE.
<br /> N
<br /> ,..
<br /> SET IN SEALANT & I DRAWN EOM REIVET SILL PAN TO
<br /> -.,, CHCK DKB
<br /> -, BOOT I,
<br /> N. E
<br /> FIELD VERIFY ALL DIMENSIONS & FIT
<br /> A
<br /> ir 4d4 N
<br /> •
<br /> , -
<br /> ( ,„ \Sill__ PAN TRANSITION BOOT AT ELEVATION CHANGE
<br /> \ 0
<br /> OAC PROJ. No. 2019012.01 .
<br />
|