My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1321 COLBY AVE 4TH FLOOR 2022-01-26
>
Address Records
>
COLBY AVE
>
1321
>
4TH FLOOR
>
1321 COLBY AVE 4TH FLOOR 2022-01-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2022 3:32:52 PM
Creation date
8/16/2021 11:31:56 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
1321
Tenant Name
4TH FLOOR
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
www.hilti.us <br />Company: <br />Specifier: <br />Address: <br />Phone I Fax: <br />E-Mail: <br />Specifier's comments: <br />Itt�u�P� �e <br />Profis Anchor 2.7.9 <br />Page: 1 <br />Project: <br />Sub -Project I Pos. No.: <br />Date: 9/1 /2020 <br />1 Input data <br />` 4 � A 4 <br />Anchor type and diameter: <br />KWIK HUS-EZ (KH-EZ) 112 (2 114) <br />Effective embedment depth: <br />he,,_, = 1.520 in., hnom = 2.250 in. <br />Material: <br />Carbon Steel <br />Evaluation Service Report: <br />ESR-3027 <br />Issued I Valid: <br />12/1/2017 1 12/1/2019 <br />Proof: <br />Design method ACI 318-14 / Mech. <br />Stand-off installation: <br />eb = 0.000 in. (no stand-off); t = 0.250 in. <br />Anchor plate: <br />Ix x ly x t = 3.000 in. x 3.000 in. x 0.250 in.; (Recommended plate thickness: not calculated <br />Profile: <br />no profile <br />Base material: <br />cracked concrete, 3000, f,' = 3,000 psi; h = 5.500 in. <br />Installation: <br />hammer drilled hole, Installation condition: Dry <br />Reinforcement: <br />tension: condition B, shear: condition B; no supplemental splitting reinforcement present <br />edge reinforcement: none or < No. 4 bar <br />Seismic loads (cat. C, D, E, or F) <br />Tension load: yes (17.2.3.4.3 (d)) <br />Shear load: yes (17.2.3.5.3 (c)) <br />R - user is responsible to ensure a rigid base plate for the entered thickness with appropriate solutions <br />(stiffeners,...) <br />Geometry [in.] & Loading [lb, in.lb] <br />Z' <br />Input data and results must be checked for agreement with the existing conditions and for plausibility! <br />PROFIS Anchor (c) 2003-2009 HIM AG, FL-9494 Schaan HE Is a registered Trademark of HIM AG, Schaan <br />7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.