My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1321 COLBY AVE 4TH FLOOR 2022-01-26
>
Address Records
>
COLBY AVE
>
1321
>
4TH FLOOR
>
1321 COLBY AVE 4TH FLOOR 2022-01-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2022 3:32:52 PM
Creation date
8/16/2021 11:31:56 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
1321
Tenant Name
4TH FLOOR
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
www.hilti.us <br />- I I WE Oil <br />Profis Anchor 2.7.9 <br />Company: <br />Page: 6 <br />Specifier: <br />Project: <br />Address: <br />Sub -Project I Pos. No.: <br />Phone I Fax: <br />Date: 9/1/2020 <br />E-Mail: <br />6 Warnings <br />• The anchor design methods in PROFIS Anchor require rigid anchor plates per current regulations (ETAG 001/Annex C, EOTA TR029, etc.). This <br />means load re -distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is assumed to be <br />sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Anchor calculates the minimum required anchor plate <br />thickness with FEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the rigid base plate assumption <br />is valid is not carried out by PROFIS Anchor. Input data and results must be checked for agreement with the existing conditions and for <br />plausibility! <br />• Condition A applies when supplementary reinforcement is used. The (V factor is increased for non -steel Design Strengths except Pullout Strength <br />and Pryout strength. Condition B applies when supplementary reinforcement is not used and for Pullout Strength and Pryout Strength. Refer to <br />your local standard. <br />• Refer to the manufacturer's product literature for cleaning and installation instructions. <br />• Checking the transfer of loads into the base material and the shear resistance are required in accordance with ACI 318 or the relevant standard! <br />• An anchor design approach for structures assigned to Seismic Design Category C, D, E or F is given in ACI 318-14, Chapter 17, Section <br />17.2.3.4.3 (a) that requires the governing design strength of an anchor or group of anchors be limited by ductile steel failure. If this is NOT the <br />case, the connection design (tension) shall satisfy the provisions of Section 17.2.3.4.3 (b), Section 17.2.3.4.3 (c), or Section 17.2.3.4.3 (d). The <br />connection design (shear) shall satisfy the provisions of Section 17.2.3.5.3 (a), Section 17.2.3.5.3 (b), or Section 17.2.3.5.3 (c). <br />• Section 17.2.3.4.3 (b) / Section 17.2.3.5.3 (a) require the attachment the anchors are connecting to the structure be designed to undergo ductile <br />yielding at a load level corresponding to anchor forces no greater than the controlling design strength. Section 17.2.3.4.3 (c) / Section 17.2.3.5.3 <br />(b) waive the ductility requirements and require the anchors to be designed for the maximum tension / shear that can be transmitted to the <br />anchors by a non -yielding attachment. Section 17.2.3.4.3 (d) / Section 17.2.3.5.3 (c) waive the ductility requirements and require the design <br />strength of the anchors to equal or exceed the maximum tension / shear obtained from design load combinations that include E, with E increased <br />by coo. <br />• Hilti post -installed anchors shall be installed in accordance with the Hilti Manufacturer's Printed Installation Instructions (MPII). Reference ACI <br />318-14, Section 17.8.1. <br />Fastening meets the design criteria! <br />Input data and results must be checked for agreement with the existing conditions and for plausibility! 12 <br />PROFIS Anchor (c) 2003-2009 HE AG, FL-9494 Schaan Hiltl is a registered Trademark of Hilti AG, Schaan <br />
The URL can be used to link to this page
Your browser does not support the video tag.