Laserfiche WebLink
Project: <br />PRMC-BHU <br />I Designed By: I RHC <br />I Date: <br />9/1/2020 <br />Project No.: <br />Client: <br />I NAC <br />Sheet: <br />of <br />ASCE 7-10 Chapter 30 Part 4: <br />Components and Cladding Design Pressures <br />Inputs <br />K,; <br />1 <br />- <br />Roof Form <br />Flat Roof <br />- <br />Wind Speed <br />115 <br />mph <br />Exposure <br />C <br />- <br />Building Height <br />74 <br />ft <br />Zone 1 Area <br />10 <br />ft'' <br />Zone 2 Area <br />10 <br />ft' <br />Zone 3 Area <br />10 <br />ft` <br />Zone 4 Area <br />10 <br />fr` <br />Zone 5 Area <br />10 <br />ft' <br />EAF E= <br />Area Reduction Factors <br />Zone <br />Negative <br />Pressure <br />Positive <br />Pressure <br />1 <br />1.000 <br />1.000 <br />2 <br />1.000 <br />1.000 <br />3 <br />1.000 <br />1.000 <br />4 <br />1.000 <br />1.000 <br />5 <br />1.000 <br />1.000 <br />Load Case <br />Zone Pressures <br />1 <br />2 <br />3 <br />4 <br />5 <br />Neg. (PSF) <br />-54.00 <br />-84.76 <br />-115.52 <br />-36.90 <br />-67.66 <br />Pos. (PSF) <br />N/A <br />N/A <br />N/A <br />36.90 <br />36.90 <br />Overhangs Neg. <br />(PSF) <br />-54.00 <br />-84.76 <br />133.25 <br />N/A <br />N/A <br />For glazing <br />20 <br />