My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1321 COLBY AVE 4TH FLOOR 2022-01-26
>
Address Records
>
COLBY AVE
>
1321
>
4TH FLOOR
>
1321 COLBY AVE 4TH FLOOR 2022-01-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2022 3:32:52 PM
Creation date
8/16/2021 11:31:56 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
1321
Tenant Name
4TH FLOOR
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br />0 <br />CITY OF EVERETT <br />Public Works Department <br />September 21, 2020 <br />Jill Kurtz <br />NAC Architecture <br />1203 West Riverside Avenue <br />Spokane, WA 99201 <br />jkurtz@nacarchitecture.com <br />Owner: Providence Health & Services <br />Job Address: 1321 Colby Avenue <br />Plan Check No: B2009-017 <br />RE: Building Permit Review Letter <br />Dear Ms. Kurtz, <br />In response to the application for a building permit, the plans have been examined and you are <br />advised that revisions may be necessary before a permit can be issued. Please review and <br />respond to the comments below. <br />1. The plans should show that fire -resistive penetrations and joints will require special <br />inspection. Section 1705.17 <br />2. The plans should note that the means of egress path at Level 2 from the North stair <br />enclosure to the exterior exit door has equivalent fire -resistive construction of an Exit <br />Passageway (two-hour partitions and 90-minute openings). <br />3. The Activity/Dining area is open to the corridor system. As this psychiatric treatment <br />area is less than 1500 square feet, it falls within the provisions of Section 407.2.3 which <br />provides for a non -separated use area. Section 407.2 <br />4. It should be confirmed that roller latches are not used on any doors into the corridor. <br />Section 407.3.1 <br />5. The procedures for egress from this treatment area should be presented to and <br />approved by the fire marshal's office as part of the emergency planning and <br />preparedness required by Chapter 4 of the IFC. Section 1010.1.9.6, Exception 1 <br />6. The refuge areas for each smoke compartment should be shown. Calculations should be <br />provided. Section 407.5.1 <br />3200 Cedar Street 425.257.8810 ® tlee@everettwa.gov <br />o O @ g <br />Everett, WA 98201 425.257.8857 fax everettwa.gov <br />
The URL can be used to link to this page
Your browser does not support the video tag.