My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
221 SE EVERETT MALL WAY ZOOM + CARE 2022-03-09
>
Address Records
>
SE EVERETT MALL WAY
>
221
>
ZOOM + CARE
>
221 SE EVERETT MALL WAY ZOOM + CARE 2022-03-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/9/2022 3:51:16 PM
Creation date
8/16/2021 1:49:27 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
221
Tenant Name
ZOOM + CARE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
COMcheck Software Version COMc a kWeb <br />Inspection Checklist <br />Energy Code: 2015 IECC <br />Requirements: 0.0% were addressed directly in the COMcheck software <br />Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each <br />requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception <br />is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. <br />Section <br /># Plan Review <br />Complies? <br />Comments/Assumptions <br />& Req.ID <br />— <br />C103.2 Plans and/or specifications provide all <br />❑Complies <br />[PR1]1 information with which compliance <br />El Does Not <br />can be determined for the building <br />❑Not Observable <br />envelope and document where <br />❑Not Applicable <br />exceptions to the standard are <br />claimed. <br />C103.2 <br />Plans, specifications, and/or <br />❑Complies <br />[PR4]1 <br />calculations provide all information <br />❑Does Not <br />with which compliance can be <br />❑Not Observable <br />determined for the interior lighting <br />❑Not Applicable <br />and electrical systems and equipment <br />and document where exceptions to <br />the standard are claimed. Information <br />provided should include interior <br />lighting power calculations, wattage of <br />bulbs and ballasts, transformers and <br />control devices. <br />C402.4.1 <br />The vertical fenestration area <= 30 <br />❑Complies <br />[PR10]1 <br />percent of the gross above -grade wall <br />❑Does Not <br />area. <br />❑Not Observable <br />❑Not Applicable <br />C402.4.1 The skylight area <= 3 percent of the ❑Complies <br />[PR11]1 gross roof area. ❑Does Not <br />❑Not Observable <br />' <br />❑Not Applicable <br />C402.4.2 In enclosed spaces > 2,500 ft2 <br />❑Complies <br />[PR14]1 directly under a roof with ceiling <br />❑Does Not <br />heights >15 ft. and used as an office, <br />❑Not Observable <br />lobby, atrium, concourse, corridor, <br />❑Not Applicable <br />storage, gymnasium/exercise center, <br />convention center, automotive <br />service, manufacturing, non - <br />refrigerated warehouse, retail store, <br />distribution/sorting area, <br />transportation, or workshop, the <br />following requirements apply: (a) the <br />daylight zone under skylights is >= <br />half the floor area; (b) the skylight <br />area to daylight zone is >= 3 percent <br />with a skylight VT >= 0.40; or a <br />minimum skylight effective aperture <br />>= 1 percent. <br />Additional Comments/Assumptions: <br />11 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) <br />Project Title: Zoom+care Everett, WA Report date: 02/27/20-, <br />Data filename: Page 4 of 10 �\ <br />
The URL can be used to link to this page
Your browser does not support the video tag.