Laserfiche WebLink
2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised August 2016 <br />Project Title: Coastal Communit Bank Administration T.I. <br />Date 2/27/2020 <br />Calculation <br />NOTE 9 <br />Area <br />0 Q Addition - O Addition <br />stand alone + existing <br />O Spaces where < 50% of 0 Spaces where >- 50% oo <br />luminaires are replaced luminaires are replaced <br />For Building Department Use <br />LPA <br />Calculation <br />Type <br />Standard O Additional Efficiency Package Option 0 <br />C406.3 Reduced Interior Lighting Power <br />To comply with C406.3, the Proposed LPD shall be 25% lower than the Target LPA. <br />Refer to C406.3 for additional requirements. <br />Maximum Allowed Lighting Wattage "oTE 1 <br />Location (plan #, <br />room #) <br />Space Type <br />Ceiling <br />Height NOTE 2 <br />Gross Interior <br />Area in ft2 <br />Allowed <br />Watts per ft2 <br />Watts Allowed <br />(watts/ft2 x area) <br />102 <br />Conference/meeting/multipurpose <br />9'-0" <br />2383 <br />0.980 <br />2335 <br />103 <br />Corridor: all other <br />9' -0" <br />522 <br />0.530 <br />277 <br />104 <br />Storage room <br />9' -0" <br />64 <br />0.500 <br />32 <br />105 <br />Electrical/mechanical <br />9'-0" <br />32 <br />0.760 <br />24 <br />106 <br />Office: Enclosed <br />9'-0" <br />139 <br />0.890 <br />124 <br />107 <br />Office: Enclosed <br />9'-0" <br />125 <br />0.890 <br />ill <br />108 <br />Office: Enclosed <br />9'-0" <br />128 <br />0.890 <br />114 <br />109 <br />Office: Enclosed <br />9'-0" <br />125 <br />0.890 <br />ill <br />110 <br />Office: Enclosed <br />9' -0" <br />128 <br />0.890 <br />114 <br />111 <br />Office: Enclosed <br />9' -0" <br />125 <br />0.890 <br />ill <br />112 <br />Office: Enclosed <br />9'-0" <br />121 <br />0.890 <br />108 <br />113 <br />Corridor: all other <br />9' -0" <br />51 <br />0.530 <br />27 <br />114 <br />Office: Open plan <br />9' -0" <br />4978 <br />0.780 <br />3883 <br />115 <br />Office: Enclosed <br />9'-0" <br />575 <br />0.890 <br />512 <br />116 <br />Office: Enclosed <br />9'-0" <br />193 <br />0.890 <br />172 <br />117 <br />Computer room <br />9'-0" <br />517 <br />1.370 <br />708 <br />118 <br />Storage room <br />9'-0" <br />79 <br />0.500 <br />40 <br />119 <br />Office: Enclosed <br />9' -0" <br />110 <br />0.890 <br />98 <br />120 <br />Office: Enclosed <br />9' -0" <br />137 <br />0.890 <br />122 <br />121 <br />Conference/meeting/multipurpose <br />9'-0" <br />250 <br />0.980 <br />245 <br />122 <br />Gymnasium/fitness center: Exercise area <br />9' -0" <br />667 <br />0.580 <br />387 <br />123 <br />Storage room <br />9' -0" <br />113 <br />0.500 <br />57 <br />124 <br />Corridor: all other <br />9' -0" <br />1782 <br />0.530 <br />944 <br />125 <br />Lounge/breakroom: all other <br />9' -0" <br />80 <br />0.580 <br />46 <br />127 <br />Lounge/breakroom: all other <br />9' -0" <br />46 <br />0.580 <br />27 <br />Total Area 13470 <br />Retail Display Allowance from LTG-INT-DISPLAY <br />Lobby Art/Exhibit Display Allowance from LTG-INT-DISPLAY NOTE 80 Allowed Watts 10729 <br />Proposed Lighting Wattage ""'t' <br />Location (plan #, <br />room #) <br />Fixture Description NOTE 4, 5, 6 <br />Number of <br />Fixtures <br />Watts/ <br />Fixture NOTE 7 <br />Watts <br />Proposed <br />102 <br />2x4 LED <br />25 <br />42 <br />1050 <br />103 <br />2x4 LED <br />10 <br />42 <br />420 <br />104 <br />1x4 LED <br />1 <br />21 <br />21 <br />105 <br />1x4 LED <br />1 <br />21 <br />21 <br />106 <br />2x4 LED <br />2 <br />42 <br />84 <br />107 <br />2x4 LED <br />2 <br />42 <br />84 <br />108 <br />2x4 LED <br />2 <br />42 <br />84 <br />109 <br />2x4 LED <br />2 <br />42 <br />84 <br />110 <br />2x4 LED <br />2 <br />42 <br />84 <br />111 <br />2x4 LED <br />2 <br />42 <br />84 <br />112 <br />2x4 LED <br />2 <br />42 <br />84 <br />113 <br />2x4 LED <br />1 <br />42 <br />42 <br />