Laserfiche WebLink
C YA M\w L E; <br />2015 Washington State Enerav Code Compliance Forms for Commercial Buildinas including R2. R3. R4 nvar 3 stnries and All Rt 901a <br />Project Title: Fill this line out on LGT-SUM <br />Date 7/1/2016 <br />Calculation <br />0 0 Addition - 0 Addition <br />For Building Department Use <br />NOTE 9 <br />Area <br />stand alone + existing <br />_ <br />0 Spaces where < 501()of Spaces where0 50% of <br />luminaires are replaced luminaires are replaced <br />LPA <br />* Standard 0 Additional Efficiency Package Option 0 <br />Calculation <br />C406.3 Reduced Interior Lighting <br />Type <br />To comply with C406.3, the Proposed LPD shall be 25% lower than the Target LPA. <br />Refer C406.3 <br />to for additional requirements. <br />Maximum Allowed Lighting Wattage "oTe t <br />Location (plan #, <br />Ceiling <br />Gross Interior <br />Allowed <br />Watts Allowed <br />room #) <br />Space Type <br />Height NOTE 2 <br />Area in fe <br />Watts per ft2 <br />(watts/ft2 x area) <br />OFFICE322 <br />Office: Enclosed <br />180 <br />0.890 <br />160 <br />OFFICE314 <br />Office: Enclosed <br />230 <br />0.890 <br />205 <br />OFFICE 318 <br />Office: Enclosed <br />154 <br />0.890 <br />137 <br />CONF RM 315 <br />Conference/meeting/multipurpose <br />156 <br />0.980 <br />153 <br />OPEN OFFICE <br />330 <br />Office: Open plan <br />480 <br />0.780 <br />374 <br />OFFICE 321 <br />Office: Enclosed <br />168 <br />0.890 <br />150 <br />Total Area 1368 <br />Retail Display Allowance from LTG-INT-DISPLAY <br />Lobby Art/Exhibit Display Allowance from LTG-INT-DISPLAY NOTE 6Allowed Watts 1179 <br />Proposed Lighting Wattage NOTE 3 <br />Location (plan #, <br />room #) <br />NOTE 4, 5, 6 <br />Fixture Description <br />Number of <br />Fixtures <br />NOTE 7 <br />Fixture <br />Watts/ <br />t--?:r k `'�•ry ^', <br />u az <br />y `t�" <br />}3; <br />(t<X <br />�xstt <br />Watts <br />Proposed <br />OFFICE322 <br />TYPE A2 <br />2 <br />60 <br />120 <br />OFFICE 314 <br />TYPE A2 <br />3 <br />60R. <br />180 <br />OFFICE 318 <br />TYPE A2 <br />2 <br />60 <br />120 <br />CONF RM 315 <br />TYPE A2 <br />2 <br />603t;,��t <br />120 <br />OPEN OFFICE <br />TYPE Al <br />14 <br />30 <br />420 <br />OFFICE321 <br />TYPE A2 <br />2 <br />60f <br />120 <br />Proposed Retail Display Lighting from LTG-INT-DISPLAY <br />Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed WattsWattsl <br />1080 <br />Interior Lighting Power Allowance COMPLIES <br />Note f -List all unique space types per Table C405.4.2(2) that occur in the project scope. Select space type category per from drop down menu. <br />Note 2 - Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.42(2), Footnotes d thru f. <br />Note 3 - List all proposed lighting fixtures including exempt lighting equipment and existing -to -remain fixtures. <br />Note 4 - For proposed Fixture Description, indicate fixture type, lamp type (e_g. T-8), number of lamps in the fixture, and ballast type (if included). For <br />track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. <br />Note 5 - For lighting equipment eligible for exemption per C405.4.1, note exception number and leave Watts/Fixture blank. <br />Note 6 - Existing -to -remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as existing <br />in fixture description. <br />Note 7- For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For <br />luminaires with screw -in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low voltage <br />lighting, enter the wattage of the transformer. For line voltage track/busway systems, enter the larger of the attached luminaire wattage or 50 <br />watt0ineal foot, or enter the wattage limit of permanent current limiting device. <br />Note 8 - LobbyArt/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. <br />Note 9 - Calculation Area Details: <br />a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing building <br />fiahtino systems to demonstrate compliance. Refer to C502.1. <br />