9TOP241737
<br />�'GRD241737
<br />�NOT241737
<br />'�3USD241737
<br />"'UWS241737
<br />I'BLOCK
<br />ASI T241737
<br />�SI T241737
<br />9LND241737
<br />PT . OF SE 1/4 OF SEC. 1.7, TWP 2 ., R5E W.M.
<br />LEGEND
<br />- - -51 WATER METER AND SERVICE LINE
<br />- ---� - N42'0513 W 25.27 --� FIRE DEPT. CONN. (FDC)
<br />N88'00'16"W 52.76' xo —F — FIRE SERVICE
<br />TfJ .. 0 4'6 "E 7. 6'
<br />OP OP
<br />r �_ STORM DRAIN
<br />W 42'04'55"W 51.54'
<br />�Q o � SD CATCH BASIN
<br />35+00 16TH TREE �� �
<br />ss+oo �
<br />- +57 SS SANITARY SEWER MAIN
<br />�. \
<br />I 43` N6$ 3849"W 11.18' 0STD. PRECAST MANHOLE
<br />SS
<br />- - - - - SIDE SEWER SERVICE
<br />SIDE SEWER CLEANOUT
<br />- _ - _ 0
<br />x�o EXIST. FIRE W WATER MAIN
<br />\ HYDRANT (TYP.) — — — — —
<br />' ' .� � •, .' — — WATER SERVICE
<br />{ �a----
<br />--------- PUBLIC UTILITY ESMT.
<br />i H FIRE HYDRANT (FH)
<br />S A 70+42. 8, 35.00' RT \\ \ N42 04'55"W 732.02' p DOMESTIC BACKFLOW ASSEMBLY (DCVA)
<br />7 BLD H C� G �\
<br />�y. \ '.
<br />CONSTRUCTION NOTES
<br />1 1' WATER SERVICE AND METER PER COE STD.
<br />DWG. 501 w/ 1" BACKFLOW ASSEMBLY (DCVA)
<br />PER COE STD. DWG. 520
<br />O2" WATER SERVICE AND METER PER COE STD.
<br />DWG. 502 w/ 2" BACKFLOW ASSEMBLY (DCVA)
<br />PER COE STD. DWG. 520
<br />(� DOUBLE CHECK DETECTOR VALVE ASSEMBLY
<br />`J (DCDA) VAULT PER COE STD. DWG. 515, SEE
<br />FIRE SYSTEM NOTE 3
<br />O2" FIRE SERVICE SUPPLY LINE (SEE FIRE
<br />SYSTEM NOTES)
<br />OFIRE HYDRANT ASSEMBLY PER COE STD. DWG.
<br />507, APPROX. 6" DI LENGTH PER PLAN
<br />OPOST INDICATOR VALVE (PIV), SEE FIRE SYSTEM
<br />NOTE 3
<br />O FIRE DEPARTMENT CONN. (FDC)
<br />U8 1" IRRIGATION METERED WATER SERVICE PER
<br />COE STD. DWG. 501 w/ 1" BACKFLOW ASSEMBLY
<br />(DCVA) PER COE STD. DW. 520. CONTRACTOR
<br />TO INSTALL
<br />O PUBLIC UTILITY EASEMENT
<br />10 3" FIRE SERVICE SUPPLY LINE (SEE FIRE
<br />SYSTEM NOTES)
<br />11 POTHOLE EXIST. WATER MAIN TO VERIFY
<br />LOCATION OF 8" SEGMENT
<br />12 SAWCUT, REMOVE AND REPLACE EXIST PVMT.
<br />13 BLOW OFF ASSEMBLY PER COE STD. DWG. 511
<br />J
<br />G
<br />�
<br />z
<br />�0
<br />U
<br />�
<br />W
<br />m
<br />0
<br />zo
<br />�
<br />W
<br />a
<br />U)
<br />a
<br />0
<br />m
<br />z
<br />zz
<br />U
<br />w
<br />W
<br />~
<br />z
<br />x
<br />o
<br />r
<br />Cn
<br />W
<br />Lu
<br />a 01
<br />q
<br />0
<br />STA 23+23.24, 1.00' RT I f t =, \, rH t LL, ►. vv tc r 4
<br />(1)8'x45' BEND, MJ e
<br />NOTES:
<br />(1) THRUST BLOCK f `; STA24+49.12, 0.83 RT
<br />x45'BEND MJ { (1)8 1. ALL WATER VALVES SHALL BE PROVIDED WITH VALVE BOX AND O
<br />r
<br />l (1) THRUST BLOCK OPERATING NUT EXTENDED PER COE STD. DWG. 505. o
<br />�.; z
<br />STA 22+86.23, ..: -�-.- _
<br />I I
<br />2 r ;: \� �\
<br />(1 8 x45 BEND, MJ '. IN T D AT ALL BENDS AND FITTINGS
<br />u 8 F £}ll \ ;, 2. MEGA LUGS SHALL BE S ALLE a
<br />(1) THRUST BLOCK' W
<br />F Bxfi °
<br />IN ACCORDANCE WITH COE STANDARDS ALL PIPES AND �
<br />I
<br />/-"- �\ � FITTINGS SHOWN AS RESTRAINED JOINTS (RJ) SHALL BE
<br />" ° \ :.
<br />- STA 2 1, t8.50 LT \
<br />'� 1 I .:; _ r, MEGALUG GASKET OR APPROVED EQUAL. z
<br />BL A 7
<br />OLF 8
<br />41
<br />J. DOMESTIC WATER SERVICE SUPPLY SHALL INCLUDE A DOUBLE _
<br />w
<br />` -_ �_ h CHECK VALVE ASSEMBLY (DCVA) INSIDE BUILDING MECHANICAL -
<br />ROOM W/MATERIALS AND CLEARANCES PER COE STD. DWG. 0
<br />1 8 X6 DI TEE, MJXFL ° -ss ° ° " 520, REF. PROJECT PLUMBING PLANS/DETAILS. o
<br />(� I �" B 1T 0 ° s ° z
<br />�.. Ii ° \
<br />(1) 5%4' FH ASSEMBLY I i ° s - `°. ° AINT, W
<br />1 THRUST BLOCK ' BLDO s 4. THE CONTRACTOR SHALL VERIFY ALL SANITARY SEWER,
<br />22LF 6" D! SPOOL
<br />,� ' , ° a "1 DOMESTIC WATER, AND FIRE SERVICE CONNECTIONS SHOWN ON
<br />.i I I � � �`: . � .. = �� ,- � �: ,
<br />jj
<br />BBQ, PATIO THIS PLAN WITH THE INFORMATION PROVIDED IN THE PROJECT
<br />° 43
<br />STA 24+10.33, 1. BASKETBALL
<br />� ° PLUMBING AND FIRE SPRINKLER PLANS/DETAILS AND NOTIFY
<br />�5 ENGINEER OF ANY VARIANCES PRIOR TO CONSTRUCTION.
<br />rn (1)8 x6 DI TEE, F COURT °
<br />(1) 5/4 FH ASSE L: j 5. ALL WATER MAIN PIPES SHALL BE DUCTILE IRON, CLASS 52 Q
<br />- - (2) 8 DI GV, MJx ° F !�� STA 25+80.79, 46.60 LT 2 WITH A MINIMUM COVER OF 36" UNLESS OTHERWISE NOTED W
<br />° °
<br />{ �-L-� (1) THRUST BLOC � AND APPROVED BY THE CITY. (�
<br />6. COE WATER DEPT. CREWS SHALL MAKE ALL CONNECTIONS TO
<br />ACTIVE PUBLIC WATER MAINS UNDER SEPARATE UTILITY PERMIT.
<br />CONNECTION FEE SHALL BE BASED ON A COST ESTIMATE BY
<br />THE WATER DEPT. AND WORK SHALL BE AT OWNERS EXPENSE. UJ O Q
<br />FIRE SYSTEM NOTES >CC
<br />4�
<br />1. FIRE SERVICE SUPPLY LINE SIZES SHOWN ARE APPROXIMATE. J �Lu w
<br />ACTUAL LINE SIZES SHALL BE PER FIRE PROTECTION ENGINEER. W m w
<br />w
<br />2. COE UTILITY SERVICES DEPARTMENT SHALL HAVE ACCESS TO /`"`r �-
<br />MECHANICAL ROOMS DURING THE HOURS OF 7:30AM TO �-
<br />4:OOPM, MONDAY THROUGH FRIDAY. ry c�
<br />J. FIRE SERVICE SUPPLY FOR THE BUILDINGS A, B, E, F, G, AND
<br />J SHALL INCLUDE A DOUBLE CHECK DETECTOR ASSEMBLY CLIENT
<br />(DCDA) INSIDE BUILDING MECHANICAL ROOM PER COE STD.
<br />DWG. 523. FIRE SERVICE SUPPLY FOR BUILDINGS C, D, AND H
<br />SHALL INCLUDE A DCDA IN AN EXTERIOR VAULT PER COE STD. RIVERVIEW I, LLC
<br />DWG. 515. POST INDICATOR VALVE (PIV) AND FIRE 10900 NE 8TH STREET
<br />DEPARTMENT CONNECTION (FDC) FOR BUILDING J SHALL SUITE 1200
<br />CONNECT TO FIRE SUPPLY SERVICE LINE DOWNSTREAM OF BELLEVUE, WA 98004
<br />DCDA. ONE-WAY CHECK VALVE FOR FDC SERVICE SHALL BE PHONE: (425) 453-9551
<br />INSTALLED INSIDE VAULT OR MECHANICAL ROOM. ALL FIRE
<br />SPRINKLER SUPPLY LINES AND APPURTENANCES SHALL BE
<br />INSTALLED PER SECTION 5-17 OF COE DESIGN AND
<br />CONSTRUCTION STANDARDS AND SPECIFICATIONS. FIRE
<br />SPRINKLER SYSTEM DESIGN AND CONNECTION DETAILS SHALL
<br />BE PROVIDED AND APPROVED UNDER SEPARATE PLUMBING
<br />PERMIT.
<br />i;g
<br />U
<br />CONSULTANTS
<br />AUG2 7 2019
<br />Site Planning • Civil Engineering
<br />Land Use Consulting • Project Management
<br />CITYOF EVE.RETT
<br />11431 Willows Rd. NE, Suite 120
<br />Permit Servic--1;
<br />Redmond, WA98052
<br />Phone: (425) 285-2390 1 FAX: (425) 285-2389
<br />www.cphconsuItants.com
<br />PROJECT NO.
<br />0024-17-037
<br />�T
<br />lv
<br />DRAWING
<br />C4.04
<br />0 30 60 Know what's below.
<br />Call before you dig.
<br />SHEET 31 OF 47
<br />PLAN IN FEET Copyright Q 2019 CPH Consultants, LLC. All Rights Reserved