Laserfiche WebLink
9TOP241737 <br />�'GRD241737 <br />�NOT241737 <br />'�3USD241737 <br />"'UWS241737 <br />I'BLOCK <br />ASI T241737 <br />�SI T241737 <br />9LND241737 <br />PT . OF SE 1/4 OF SEC. 1.7, TWP 2 ., R5E W.M. <br />LEGEND <br />- - -51 WATER METER AND SERVICE LINE <br />- ---� - N42'0513 W 25.27 --� FIRE DEPT. CONN. (FDC) <br />N88'00'16"W 52.76' xo —F — FIRE SERVICE <br />TfJ .. 0 4'6 "E 7. 6' <br />OP OP <br />r �_ STORM DRAIN <br />W 42'04'55"W 51.54' <br />�Q o � SD CATCH BASIN <br />35+00 16TH TREE �� � <br />ss+oo � <br />- +57 SS SANITARY SEWER MAIN <br />�. \ <br />I 43` N6$ 3849"W 11.18' 0STD. PRECAST MANHOLE <br />SS <br />- - - - - SIDE SEWER SERVICE <br />SIDE SEWER CLEANOUT <br />- _ - _ 0 <br />x�o EXIST. FIRE W WATER MAIN <br />\ HYDRANT (TYP.) — — — — — <br />' ' .� � •, .' — — WATER SERVICE <br />{ �a---- <br />--------- PUBLIC UTILITY ESMT. <br />i H FIRE HYDRANT (FH) <br />S A 70+42. 8, 35.00' RT \\ \ N42 04'55"W 732.02' p DOMESTIC BACKFLOW ASSEMBLY (DCVA) <br />7 BLD H C� G �\ <br />�y. \ '. <br />CONSTRUCTION NOTES <br />1 1' WATER SERVICE AND METER PER COE STD. <br />DWG. 501 w/ 1" BACKFLOW ASSEMBLY (DCVA) <br />PER COE STD. DWG. 520 <br />O2" WATER SERVICE AND METER PER COE STD. <br />DWG. 502 w/ 2" BACKFLOW ASSEMBLY (DCVA) <br />PER COE STD. DWG. 520 <br />(� DOUBLE CHECK DETECTOR VALVE ASSEMBLY <br />`J (DCDA) VAULT PER COE STD. DWG. 515, SEE <br />FIRE SYSTEM NOTE 3 <br />O2" FIRE SERVICE SUPPLY LINE (SEE FIRE <br />SYSTEM NOTES) <br />OFIRE HYDRANT ASSEMBLY PER COE STD. DWG. <br />507, APPROX. 6" DI LENGTH PER PLAN <br />OPOST INDICATOR VALVE (PIV), SEE FIRE SYSTEM <br />NOTE 3 <br />O FIRE DEPARTMENT CONN. (FDC) <br />U8 1" IRRIGATION METERED WATER SERVICE PER <br />COE STD. DWG. 501 w/ 1" BACKFLOW ASSEMBLY <br />(DCVA) PER COE STD. DW. 520. CONTRACTOR <br />TO INSTALL <br />O PUBLIC UTILITY EASEMENT <br />10 3" FIRE SERVICE SUPPLY LINE (SEE FIRE <br />SYSTEM NOTES) <br />11 POTHOLE EXIST. WATER MAIN TO VERIFY <br />LOCATION OF 8" SEGMENT <br />12 SAWCUT, REMOVE AND REPLACE EXIST PVMT. <br />13 BLOW OFF ASSEMBLY PER COE STD. DWG. 511 <br />J <br />G <br />� <br />z <br />�0 <br />U <br />� <br />W <br />m <br />0 <br />zo <br />� <br />W <br />a <br />U) <br />a <br />0 <br />m <br />z <br />zz <br />U <br />w <br />W <br />~ <br />z <br />x <br />o <br />r <br />Cn <br />W <br />Lu <br />a 01 <br />q <br />0 <br />STA 23+23.24, 1.00' RT I f t =, \, rH t LL, ►. vv tc r 4 <br />(1)8'x45' BEND, MJ e <br />NOTES: <br />(1) THRUST BLOCK f `; STA24+49.12, 0.83 RT <br />x45'BEND MJ { (1)8 1. ALL WATER VALVES SHALL BE PROVIDED WITH VALVE BOX AND O <br />r <br />l (1) THRUST BLOCK OPERATING NUT EXTENDED PER COE STD. DWG. 505. o <br />�.; z <br />STA 22+86.23, ..: -�-.- _ <br />I I <br />2 r ;: \� �\ <br />(1 8 x45 BEND, MJ '. IN T D AT ALL BENDS AND FITTINGS <br />u 8 F £}ll \ ;, 2. MEGA LUGS SHALL BE S ALLE a <br />(1) THRUST BLOCK' W <br />F Bxfi ° <br />IN ACCORDANCE WITH COE STANDARDS ALL PIPES AND � <br />I <br />/-"- �\ � FITTINGS SHOWN AS RESTRAINED JOINTS (RJ) SHALL BE <br />" ° \ :. <br />- STA 2 1, t8.50 LT \ <br />'� 1 I .:; _ r, MEGALUG GASKET OR APPROVED EQUAL. z <br />BL A 7 <br />OLF 8 <br />41 <br />J. DOMESTIC WATER SERVICE SUPPLY SHALL INCLUDE A DOUBLE _ <br />w <br />` -_ �_ h CHECK VALVE ASSEMBLY (DCVA) INSIDE BUILDING MECHANICAL - <br />ROOM W/MATERIALS AND CLEARANCES PER COE STD. DWG. 0 <br />1 8 X6 DI TEE, MJXFL ° -ss ° ° " 520, REF. PROJECT PLUMBING PLANS/DETAILS. o <br />(� I �" B 1T 0 ° s ° z <br />�.. Ii ° \ <br />(1) 5%4' FH ASSEMBLY I i ° s - `°. ° AINT, W <br />1 THRUST BLOCK ' BLDO s 4. THE CONTRACTOR SHALL VERIFY ALL SANITARY SEWER, <br />22LF 6" D! SPOOL <br />,� ' , ° a "1 DOMESTIC WATER, AND FIRE SERVICE CONNECTIONS SHOWN ON <br />.i I I � � �`: . � .. = �� ,- � �: , <br />jj <br />BBQ, PATIO THIS PLAN WITH THE INFORMATION PROVIDED IN THE PROJECT <br />° 43 <br />STA 24+10.33, 1. BASKETBALL <br />� ° PLUMBING AND FIRE SPRINKLER PLANS/DETAILS AND NOTIFY <br />�5 ENGINEER OF ANY VARIANCES PRIOR TO CONSTRUCTION. <br />rn (1)8 x6 DI TEE, F COURT ° <br />(1) 5/4 FH ASSE L: j 5. ALL WATER MAIN PIPES SHALL BE DUCTILE IRON, CLASS 52 Q <br />- - (2) 8 DI GV, MJx ° F !�� STA 25+80.79, 46.60 LT 2 WITH A MINIMUM COVER OF 36" UNLESS OTHERWISE NOTED W <br />° ° <br />{ �-L-� (1) THRUST BLOC � AND APPROVED BY THE CITY. (� <br />6. COE WATER DEPT. CREWS SHALL MAKE ALL CONNECTIONS TO <br />ACTIVE PUBLIC WATER MAINS UNDER SEPARATE UTILITY PERMIT. <br />CONNECTION FEE SHALL BE BASED ON A COST ESTIMATE BY <br />THE WATER DEPT. AND WORK SHALL BE AT OWNERS EXPENSE. UJ O Q <br />FIRE SYSTEM NOTES >CC <br />4� <br />1. FIRE SERVICE SUPPLY LINE SIZES SHOWN ARE APPROXIMATE. J �Lu w <br />ACTUAL LINE SIZES SHALL BE PER FIRE PROTECTION ENGINEER. W m w <br />w <br />2. COE UTILITY SERVICES DEPARTMENT SHALL HAVE ACCESS TO /`"`r �- <br />MECHANICAL ROOMS DURING THE HOURS OF 7:30AM TO �- <br />4:OOPM, MONDAY THROUGH FRIDAY. ry c� <br />J. FIRE SERVICE SUPPLY FOR THE BUILDINGS A, B, E, F, G, AND <br />J SHALL INCLUDE A DOUBLE CHECK DETECTOR ASSEMBLY CLIENT <br />(DCDA) INSIDE BUILDING MECHANICAL ROOM PER COE STD. <br />DWG. 523. FIRE SERVICE SUPPLY FOR BUILDINGS C, D, AND H <br />SHALL INCLUDE A DCDA IN AN EXTERIOR VAULT PER COE STD. RIVERVIEW I, LLC <br />DWG. 515. POST INDICATOR VALVE (PIV) AND FIRE 10900 NE 8TH STREET <br />DEPARTMENT CONNECTION (FDC) FOR BUILDING J SHALL SUITE 1200 <br />CONNECT TO FIRE SUPPLY SERVICE LINE DOWNSTREAM OF BELLEVUE, WA 98004 <br />DCDA. ONE-WAY CHECK VALVE FOR FDC SERVICE SHALL BE PHONE: (425) 453-9551 <br />INSTALLED INSIDE VAULT OR MECHANICAL ROOM. ALL FIRE <br />SPRINKLER SUPPLY LINES AND APPURTENANCES SHALL BE <br />INSTALLED PER SECTION 5-17 OF COE DESIGN AND <br />CONSTRUCTION STANDARDS AND SPECIFICATIONS. FIRE <br />SPRINKLER SYSTEM DESIGN AND CONNECTION DETAILS SHALL <br />BE PROVIDED AND APPROVED UNDER SEPARATE PLUMBING <br />PERMIT. <br />i;g <br />U <br />CONSULTANTS <br />AUG2 7 2019 <br />Site Planning • Civil Engineering <br />Land Use Consulting • Project Management <br />CITYOF EVE.RETT <br />11431 Willows Rd. NE, Suite 120 <br />Permit Servic--1; <br />Redmond, WA98052 <br />Phone: (425) 285-2390 1 FAX: (425) 285-2389 <br />www.cphconsuItants.com <br />PROJECT NO. <br />0024-17-037 <br />�T <br />lv <br />DRAWING <br />C4.04 <br />0 30 60 Know what's below. <br />Call before you dig. <br />SHEET 31 OF 47 <br />PLAN IN FEET Copyright Q 2019 CPH Consultants, LLC. All Rights Reserved <br />.�• <br />a• a f's' Y'\ 7"' P°\ d i ri r— 0 A to IT' <br />S'ctVIi.-...VBE:V Fk.%i1 1 <br />