Laserfiche WebLink
GENERAL -_ MI <br />ATING NC ITUIPMIRNT.- <br />THE INTERIOR OESiGN TEMPERATURES USED FOR HEATING AND COOLING LOAD CALCULATIONS SMALL <br />HE A MAXIMUM OF 727, 22CT FOR HEATING AND MINIMUM OF 75°F (24'C FOR COOLING PER R302,1. <br />THE HEATING OR COOLIN� OUTDOOR DESIGN TEMPERATURES SHALL BE S CTED FROM APPENDIX C <br />PER R302.2 WSEC. HEATING AND COOLING EQUIPMENT SHALT. BE SIZED IN ACCORDANCE WITH ACCA <br />MANUAL S BASED ON BUILDING LOADS CALCULATED IN ACCORDANCE WITH ACCA MANUAL J OR <br />OTHER APPROVED HEATING AND COOLING CALCULATION METHODOLOGIES PER R4033 WSEC. SYSTEMS <br />SERVING MULTIPLE DWELLING UNITS SHALL COMPLY WITH SECTIONS C403 AND C4404 OF THE IECC <br />COMMERCIAL PROVISIONS IN LIEU OF SECTION R403 PER R4018 WSEC <br />EQUIPMENT AND APPLIANCES HAVING AN IGNITION SOURCE AND LOCATED IN A GARAGE SHALL BE <br />ELNVATED SO THAT THE SOURCE OF IGNITION IS NOT LESS THAN 18 INCHES ABOVE THE FLOM <br />SURFACE PER IMC SECTION 304.3. <br />POTABLE WATER HEATERS AND HOT WATER STORAGE TANKS SHALL BE LISTED AND LABELED AND <br />INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS, THE <br />INTERNATIONAL PLUMBING CODE AND THE INTERNATIONAL MECHANICAL CODE. AL.L WATER -HEATERS <br />1 <br />a i I5 <br />k <br />yl 1 f I i ..� ' i! t I ►mil <br />IBIC FOOT PER MINUTE = 0.0004719W/s <br />;f <br />s <br />PERMITTEDFOR VENTILATION SYSTEM RUN TIME VALUES BETWEEN THOSE GIVEN, THE FACTORS <br />ARE BE DETERMINED BY <br />INTERP(ILATION. <br />BEYONDb. EXTRAPOLATION THE TABLEE IS PROHIBITED. <br />METHOD I, IRC M1507.3,4 WOLE HOUSE VENTILATION USING EXHAUST FANS, <br />M1507,3.4,1 -HOUSE VENTILATION FANS. EXHAUST FANS PROVIDING WHO HOUSE <br />VENTILATION SHALL HAVE A FLOW RATING AT 0.25 INCHES WATER GAUGE AS SPECIFIED IN TABLE <br />M1507.3.3(1�. MANUFACTUR FAN FLOW RATINGS SHALL BE DETERMINED ACCORDING TO HVI <br />916ORAMA210. <br />M1507.3,4.2 FAN NOISE, MOLE HOUSE FANS LOCATED 4 FEET OR LESS FROM THE INTERIOR <br />GRILLE SHALL HAVE A SOME RATING OF 1.0 OR LESS MEASURED AT 0.1 INCHES WATER GAUGE, <br />MANUFACTURER'S NOISE RATINGS SHALL BE DETERMINED AS PER HVI 915 (MARCH 2O09). <br />REMOTELY MOUNTED FANS SHALL BE ACOUSTICALLY IS FROM THE STRUCTURAL ELEMENTS <br />OF THE BUILDING AND FROM ATTACHED DUCT WORK USING INSULATED FLEXIBLE DUCT OR OTHER <br />APPROVED MATERIAL <br />M1 a07.3.4.3 FAIT CONTROLS, THE WHOLE HOUSE VENTILATION FAN SHALL MEET THE <br />REQUIREMENTS OF SECTION M1507.3.2 AND M1507,311. <br />M1507,3.4.4 VENTILATION OPENINGS. EACH HABITABLE SPACE SHALL BE PROVIDED WITH OUTDOOR AIR <br />INLETS OR OPERABLE WINDOWS WITH AN OPENABLE AREA NOT LESS THAN 4 SQUARE INCHES OF NET <br />FREE AREA OF OPENING FOR EACH 10 CFM OF OUTDOOR AIR REQUIRED BY TABLE M15007.3,30), WHERE <br />OUTDOOR AIR SUPPLIES ARE SEPARATED FROM EXHAUST POINTS BY DOORS, PROVISIONS SMALL BE <br />MADE TO ENSURE AIR FLOW BY INSTALLATION OF DISTRIBUTION DUCTS, UNDERCUTTING DOORS, <br />INSTALLATION OF GRfL1E5, TRANsOmS, OR SIMILAR MEANS. DOORS SHALL BE UNDERCUT TO A MINI' <br />OF 1/2 INCH ABOVE THE SURFACE OFF THE FINISH FLOOR COVERING. <br />INDIVIDUAL ROOM OUTDOOR AIR INLETS SHALL- <br />1. HAVE CONTROLLABLE AND SECURE OPENINGS; <br />2. BE SLEEVED OR OTHERWISE DESIGNED SO AS NOT TO COMPROMISE THE THERMAL PROPERTIES <br />OF DIE WALL OR WINDOW IN MICH THEY ARE PLACED, <br />3. ANY INLET OR COMBINATION OF INLETS WHICH PROVIDE 10 CFM AT 10 PASCALS ARE DEEMED <br />EQUIVALENT TO 4 SQUARE INCITES NET MEEE AREA, <br />VENTILATION OPENING SHAD BE SCREENED OR OTHERWISE PROTECTED FROM ENTRY BY LEAVES OR <br />OTHER MATERIAL. OPENINGS SHALL HE CONTROLLABLE, SECURABLE AND SHALL BE DESIGNED TO <br />NOT COMPROMISE THE THERMAL PROPERTIES OF THE BUILD)ING ENVELOPE. VENTILATION OPENINGS <br />SHALL BE LOCATED SO AS NOT TO TARE AIR FROM THE FOLLOWING AREAS: <br />1, CLOSER THAN 10 FEET FROM AN APPLIANCE VENT OUTLET, UNLESS SUCH VENT OUTLET IS 3 <br />FEET ABOVE THE OUTDOOR AIR INLET, <br />2. WHERE IT WILL PICK UP OBJECTIONABL IF ODORS, FUMES OR FLAMMABLE VAPORS. <br />1 A HAZARDOUS OR UNSANITARY LOCATION. <br />4. A ROOM OR SPACE HAVING ANY FUEL -BURNING APPLIANCES THEREIN, <br />5, CLOSER THAN 10 FEET FROM A VENT OPENING OF A PWM81NG DRAINAGE SYSTEM UNLESS THE <br />VENT OPENING IS AT LEAST 3 FEET ,ABOVE THE AIR INLET. <br />6. ATTIC, CRAWL SPACES, OR GARAGES. <br />7. ASPHALT ROOFS UNLESS IT IS SHOWN THAT NO OTHER LOCATION IS PERMISSIBLE. IN SUCH <br />CASES THE INLET OPENING SHALL HE LOCATED A MINIMUM OF 2 FEET FROM THE NEAREST <br />SURFACE OF THE ASPHALT ROOFING, MEASURED FROM THE INTAKE OPENING. <br />METHOD M1507.3,5.1 INTEGRATED 'MOLE HOUSE VENTILATION SYSTEMS. INTEGRATED <br />WHOLE -HOUSE VENTILATION SYSTEMS SHALL PROVIDE OUTDOOR AIR AT THE RATE CALCULATED <br />USING SECTION M1507.3,3. INTEGRATED FORCED -AIR VENTILATION SYSTEMS SHALL DISTRIBUTE <br />OUTDOOR AIR TO EACH HABITABLE SPACE THROUGH THE FORCED -AIR SYSTEM DUCTS. INTEGRATED <br />FORCED -AIR VENTILATION SYSTEMS SHALL HAVE AN OUTDOOR AIR INLET DUCT CONNECTING A <br />TERMINAL ELEMENT ON THE OUTSIDE OF THE BUILDING 'TO THE RETURN AIR PLENUM OF THE <br />FORCED -AIR SYSTEM, AT A POINT WITHIN 4 FEET UPSTREAM OF THE AIR HANDLER. THE OUTDOOR <br />AIR INLET DUCT CONNECTION TO THE RETURN AIR STREAM SHALL BE LOCATED UPSTREAM OF THE <br />FORCED -AIR SYSTEM BLOWER AND SHALL NOT BE CONNECTED DIRECTLY INTO A FURNACE CABINET <br />TO PREVENT THERMAL SHOCK TO THE HEAT EXCHANG E THE SYSTEM WILL BE EQUIPPED WITH A <br />MOTORIZED DAMPER CONNECTED TO THE AUTOMATIC VENTILATION CONTROL AS SPECIFIED IN <br />SECTION M1507.3,2. THE REQUIRED FLOW RATE SHALL BE VERIFIED BY HELD TESTING WITH A FLOW <br />HOOD OR A FLOW MEASURING STATION. <br />M1507.3,5,2 VENTILATION DUCT INSULATION. ALL SUPPLY DUCTS IN THE CONDITIONED SPACE <br />SHALL BE INSULATED TO A MINIMUM OF Rm4. <br />M1507,3.5.3 OUTDOOR AIR INLETS, INLETS SHALL HE SCREENED OR OTHERWISE PROTECTED FROM <br />ENTRY BY LEAVES OR OTHER MATERIAL OUTDOOR AIR INLETS SMALL HE LOCATED SO AS NOT TO <br />TAKE AIR FROM THE FOLLOWING AREAS: <br />1. CLOSER THAN 10 FEET FROM AN APPLIANCE VENT OUTLET, UNLESS SUCH VENT OUTLET IS 3 <br />FEET ABOVE THE OUTDOOR AIR INLET, <br />2. WHERE E IT Will PICK UP 08JECTIONABLE ODORS, FUMES OR FLAMMABLE VAPORS, <br />3. A HAZARDOUS OR UNSANITARY LOCATION, <br />C A ROOM OR SPACE HAVING ANY FUEI BURNING APPLIANCES THEREIN. <br />5. CLOSER THAN 10 FEET FROM A VENT OPENING OF A PLUMBING DRAINAGE SYSTEM UNLESS THE <br />VENT OPENING IS AT LEAST 3 FEET ABOVE THE AIR INLET, <br />6. ATTIC, CRAWL SPACES, OR GARAGES. <br />METHOD 3, M1507,3.6, WHOLE HOUSE VENTILATION USING A SUPPLY FAN. SUPPLY FAN <br />VENTILATION SYSTEMS SHALL DISTRIBUTE OUTDOOR AIR TO EACH HABITABLE SPACE THROUGH THE <br />FOR -AIR SYSTEM DUCTS OR THROUGH DEDICATED DUCTS TO EACH HABITABLE SPACE. SUPPLY <br />FANS SHALL HAVE THE CAPACITY TO PROVIDE THE AMOUNT OF OUTDOOR AIR SPECIFIED IN TA <br />M1507.3,31 AT 0.40 INCHES WATER GAUGE AS PER HVI 9% THE OUTDOOR AIR MUST BE <br />FILTERED FORE IT IS DELIVERED TO HABITABL r SPACES, THE FILTER MAY BE LOCATED AT THE <br />INTAKE DEVICE, IN LINE WITH THE FAN, OR, IN THE CASE OF A CONNECTION TO THE RETURN <br />PLENUM OF THE AIR HANDLER, USING THE FURNACE FILTER, AN OUTDOOR AIR INLET SHALL BE <br />CONNECTED TO EITHER THE SUPPLY OR RETURN AIR STREAM. <br />M1507.3.6.2 DUCTS, AN OUTDOOR AIR INLET DUCT CONNECTION TO THE SUPPLY AIR STREAM SHALL <br />BE LOCATED DOWNSTREAM OF THE FORCED -AIR SYSTEM GLOWER. IF CONNECTED TO THE RETURN AIR <br />STREAM IT SHALL BE LOCATED AT LEAST 4 FEET UPSTREAM OF THE FORCED -AIR SYSTEM BLO <br />MO ITS FILTER, NEITHER SHALL BE CONNECTED DIRECTLY INTO A FURNACE CABINET. THE DUCT <br />SHALL BE SIZED IN ACCORDANCE NTH TABLE M1507.3.6.2. THE TERMINAL ELEMENT ON THE OUTSIDE <br />OF THE BUILDING SMALL BE SIZED 2 INCHES DIA. LARGER THAN THE OUTDOOR AIR INLET DUCT, <br />TABLE M1507.3.6,2 <br />PRESCRIPTIVE SUPPLY FAIN DUCT SIZING <br />SUPPLY FAN TESTED CFM AT 0.40' INC <br />SPECIFIED <br />VOLUME FROM <br />TABLE <br />M1507,13(I) <br />MINIMUM <br />SMOOTH DUCT <br />DIAMETER <br />MINIMUM <br />FLEXIBLE DUCT <br />DIAMETER <br />50-90ch <br />4 INCH <br />5 INCH <br />90-150cfm <br />5 INCH <br />6 INCH <br />150-120crh <br />6INCH <br />71NCH <br />250® c% <br />7INCH <br />8INCH <br />M1507,3,6.3 DAJPFRS, THE SYSTEM SHALL PE EQUIPPED WITH A BACK -DRAFT DAMPER AND ONE <br />OF THE FOLLOWING: <br />1. A CALIBRATED MANUAL VOLUME DAMPER INSTALLED AND SET TO MEET THE MEASURED FLOW <br />RATES SPECIFIED IN TABLE M1507,13(1) BY FIELD TESTING WITH A PRESSURE GAUGE AND/OR <br />FOLLOWING MANUFACTURER'S INSTALLATION INSTRUCTIONS, OR <br />2. A MANUAL `4OWME DAMPER INSTALLED AND SET TO MEET THE MEASURED FLOW RATES <br />SPECIFIED IN TABLE M1507.3.3(1) BY FIELD TESTING WITH A FLOW HOOD OR A FLOW MEASURING <br />STATION; OR <br />1 AN AUTOMATIC FLOW -REGULATING DEVICE SIZED TO THE SPECIFIED FLOW RATES IN TABLE <br />M1507.13(1) WHICH PROVIDES CONSTANT FLOW OVER A PRESSURE RANGE OF 0.20 TO 0.60 <br />INCHES WATER GAUGE, <br />M1507.3.6.4 VENTILATION DUCT INSULATION, ALL SUPPLY DUCTS IN THE CONDITIONED SPACE <br />SHALL BE INSULATED TO A MINIMUM OF R®4. <br />M1507.3.6.5 OUTDOOR AIR INLETS, INLETS SHALL BE SCREENED OR OTHERWISE PROTECTED FROM <br />ENTRY BY LEAVES OR OTHER MATERIAL OUTDOOR AIR INLETS SHALL BE LOCATED SO AS NOT TO <br />TAKE AIR FROM THE FMOWI NG AREAS, <br />1, CLOSER THAN 10 FEET FROM AN APPLIANCE VENT OUTLET, UNLESS SUCH VENT OUTLET IS 3 <br />FEET AEIOVEE THE OUTDOOR AR INLET. <br />2. WHERE IT WW1LL PICK UP 08-JECEONAM ODORS, FUMES OR FLAMMABI F VAPORS. <br />3. A HAZARDOUS OR UNSANTARY LOCATION, <br />4. A ROM OR SPACE HAVING ANY FUEL -BURNING APPLIANCES THEREIN. <br />5. CLOSER THAN 10 FEET FROM A VENT OPENING OF A PLUMBING DRAINAGE SYSTEM UNLESS THE <br />VENT OPENING IS AT LEAST 3 FEET ABOVE THE AIR INLET. <br />6, ATTIC, CRAWL SPACES, OR GARAGES, <br />AREA TO BE EXHAUSTED EXHAUST RATES <br />100 INTERMITTENT OR <br />KITCHENS 25 CFM CONTINUOUS _ <br />BATHROOMS ® TOILET ROOMS MECHANICAL EXHAUST <br />LAUNDRY ROOMS CAPACITY OF <br />INDOOR SWIMMING POOLS 50 CFM INTERMITTENT OR <br />SPAS 20 CFM CONTINUOUS <br />FOR Si:1 CUBIC FOOT PER MINUTE v 0.0004719MI/S <br />M1507.4.1 LOCAL EXHAUST FANS, EXHAUST FANS PROVIDING LOCAL EXHAUST SHALL HAVE A <br />MINIMUM FAN FLOW RATING N0T LESS THAN 50 GEM AT 0.25 INCHES WATER GAUGE FOR <br />BATHROOMS, LAUNDRIES, OR SIMILAR ROOMS MD 100 CFM AT 0,25 INCHES WATER GAUGE FOR <br />KITCHENS. MANUFACTURERS' FAN FLOW RATINGS SHALL BE DETERMINED AS PER HVI 916 (APRIL <br />191 OR AMCA 210E <br />EXCEPTION: WHERE A RANGE HOOD OR DON DRAFT EXHAUST FAN IS USED TO SATISFY THE <br />LOCAL EXHAUST REQUIREMENTS FOR KITCHENS, THE RANGE HOOD OR DOW 1 DRAFT EXHAUST <br />SHALL NOT BE LESS THAN 100 CFM AT 0.10 INCHES WATER GAUGE, <br />M1507.4,2 LOCAL EXHAUST CONTROLS. LOCAL EXHAUST SYSTEMS SHALL BE CONTROLLED BY <br />MANUAL SWITCHES, DEHUMIDISTATS, TIMERS, OR OTHER APPROVED MEANS, LOCAL EXHAUST <br />SYSTEM CONTROLS SHALL BE READILY ACCESSIBLE. <br />IRC CHAe_U� L6 I ICI SYS1T M5 WASHINGTON AMENDIa9ENT� <br />IRC M1601,1 DUCT DESIGN. DUCT SYSTEMS SERVING HEATING, COINING AND VENTILATION EQUIPMENT SHALL <br />BE INSTALLED IN ACCORDANCE NTH THE PROVISIONS OF THIS SECTION AND ACCA MANUAL D OR OTHER <br />APPROVED METHODS, <br />M1601.1.1 ABOV E-GROUND DUCT SYSTEMS. ABOVE®GROUND DUCT SYSTEMS SLIALL CONFORM TO THE <br />FOLLOWING: <br />1. EQUIPMENT CONNECTED TO DUCT SYSTEMS SHALL BE DESIGNED TO LIMIT DISCHARGE AIR TEMPERATURE <br />TO A MAXIMUM OF 250'F (121'C). <br />2. FACTORY -MADE DUCTS SHALL HE LISTED AND LABELED IN ACCORDANCE WITH UL 181 AND INSTALLED IN <br />ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTION& <br />3. FIBROUS DUCT CONSTRUCTION %AU CONFORM TO THE SMACNA FIBROUS CLASS DUCT CONSTRUCTION <br />STANDARDS OR NAIMA FIBROUS GLASS DUCT CONSTRUCTION STANDARDS, <br />4, FIELD -FABRICATED AND SHOP -FABRICATED METAL AND FLEXIBLE DUCT CONSTRUCTIONS SHAD CONFORM <br />TO THE SMACNA HVAC DUCT CONSTRUCTION STANDARDS -METAL MI) FLEXIBLE, EXCEPT AS ALLOWED BY <br />TABLE M1601.1,1. GALVANIZED STEEL SHALL CONFORM TO ASTM A 6533E <br />5, USE OF GYPSUM PRODUCTS TO CONSTRUCT RETURN AIR DUCTS OR PLENUMS IS PERMITTED, PROVIDED <br />THAT THE AIR TEMPERATURE DOES NOT EXCEED 1257 (527C) AND EXPOSED SURFACES ARE NOT SUBJECT <br />TO CONDENSATION. <br />6. DUCT SYSTEMS SHALL BE CONSTRUCTED OF MATERIALS HAVING A ME SPREAD INDEX NOT GREATER <br />THAN 200. <br />7. STUD WALL CAVITIES AND THE SPACES BETWEEN SOLID FLOOR JOISTS SHALL NOT BE USED AS A DUCT <br />OR AN AIR PLENUM IN NEW CONSTRUCTION. FOR EXISTING SYSTEMS, STUD WALL CAVITIES AND THE <br />SPACES BETWEEN SOLD FLOOR JOISTS TO BE USED AS AIR PLENUMS SHALL COMPLY WITH THE FOLLOWING: <br />7.1. THESE CAVITIES OR SPACES SHALL NOT BE USED AS A PLENUM FOR SUPPLY AIR, <br />7.2. THESE CAVITIES OR SPACES SHALL NOT BE PART OF A REQUIRED FIRE-REUSTANCE-RATED <br />ASSEMBLY. <br />7,3E STUD WALL CAVITIES SHALL NOT CONVEY AIR FROM MORE THAN ONE FLOOR LEVEL. <br />7.4, STUD WALL CAVITIES AND JOIST -SPACE PLENUMS SHALL BE ISOLATED FROM ADJACENT CONCEALED <br />SPACES BY TIGHT -FITTING FIRE BLOCKING IN ACCORDANCE WITH SECTION R602,8, <br />7.5E STUD WALL CAVITIES IN THE OUTSIDE WADS OF BUILDING ENVELOPE ASSEMBLIES SHALL NOT BE <br />UTILIZED AS AIR P LIMS. <br />SOLID FUEL BURNING APPLIANCES: <br />SOLID FUEL BURNING APPLIANCES (INCLUDING STOVES, ROOM BEATERS, FACTORY BUILT <br />FIREPLACES, FIREPLACE INSERTS, AND MASONRY HEATERS) SHALL COMPLY WITH THE PROVISIONS <br />OF IMC, CHAPTERS 3 AND 9, AND IRC CHAPTER 10. <br />SOHO FUEL BURNING APPLIANCES SHALL BE PROVIDED WITH TIGHT FITTING METAL OR CERAMIC <br />CLASS DOORS AND ONE OF THE FOLLOWING: <br />1. A SOURCE FROM OUTSIDE THE STRUCTURE OF PRIMARY COMBUSTION AIR, CONNECTED TO THE <br />APPLIANCE AS PER MANUFACTURER'S SPECIFICATION. TIME AIR INLET SHALL ORIGINATE AT A POINT <br />BELOW THE. FIRE BOX. THE DUCT SHALL BE 4 INCHES OR GREATER IN DIAMETER, NOT EXCEED 20 <br />FEET IN LENGTH, AND BE INSTALLED AS PER MANUFACTURER'S INSTRUCTIONS; <br />2. THE APPLIANCE AND MANUFACTURER'S RECOMMENDED COMBUSTION AIR SUPPLY, AS AN <br />INSTALLED UNIT, SHALL BE CERTIFIED BY AN INDEPENDENT TESTING LABORATORY TO HAVE PASSED <br />TEST NO. 11-NEGATIVE PRESSURE TEST, SECTION 12.3E OF ULC S627-M1984 "SPACE HEATERS <br />FOR USE WITH SOLID FUELS." <br />FIREPLACES SHALL BE PROVIDED WITH READILY ACCESSIBLE MANUAL OR APPROVED AUTOMATIC <br />TIGHT FITTING FLUE DAMPERS, EXCEPT FIREPLACES WITH GAS LOGS ?JUST COMPLY WITH IMC 901 <br />OR LIQUEFIED PETROLEUM GAS INSTALLATIONS SHALL BE PER NFPA 58 AND 54. A 6 SO. IN. <br />OUTSIDE SOURCE FOR COMBUSTION AIR SHALL BE PROVIDED NTH AN OUTSIDE AIR DUCT DAMPER <br />(EXCEPTION: WA CERTIFIED FIREPLACES SHALL BE INSTALLED VAIN THE COMBUSTION AIR SYSTEM <br />NECESSARY FOR THEIR SAFE AND EFFICIENT COMBUSTION AS SPECIFIED BY THE MANUFACTURER). <br />SITE BUILT FIREPLACES SHALL HAVE TIGHT FITTING GLASS OR METAL DOORS, OR A FLUE DRAFT <br />INDUCTION FAN OR AS APPROVED FOR MINIMIZING BACK -DRAFTING. FACTORY BUILT FIREPLACES <br />SHAH. USE DOORS LISTED FOR THE INSTALLED APPLIANCE. <br />aEVIcEWED FOR PERUHT <br />COPYRYRIGHT@2016 DESIGN LINES, INC„ ALL RIGHTS RESERVED. THE USE OF THIS <br />SHEET IS EXCLUSIVELY FOR THE CLIENTS OF DESIGN LINES, INC, AND ONLY FOR <br />THE PARTICULAR PROJECT FOR WHICH THE PRINTS WERE ISSUED. USE OR REUSE <br />OF THIS SHEET FOR ANY OTHER PROJECT IS STRICTLY FORBIDDEN AND SUBJECT <br />TO PENALTY OF LAW. <br />co <br />_j <br />to <br />w <br />en <br />CD <br />00 <br />C) <br />to <br />w CA <br />4 <br />16 <br />4V <br />Ld <br />UA <br />rLn <br />