VqINDOVq
<br />56HEOULE
<br />NUMBER
<br />ROOM NAM
<br />HEIGHT IEGRE55
<br />TEMPERED
<br />-PACT R
<br />DE50RIPTION
<br />5 G7
<br />W05
<br />-FLOORWIDTH
<br />GREAT ROOM
<br />2
<br />36 "
<br />44 "
<br />0.26
<br />DOUBLE HUNG
<br />W06
<br />GREAT ROOM
<br />2
<br />32 "
<br />45 "
<br />0.28
<br />DOUBLE HUNG
<br />W07
<br />BEDROOM
<br />2
<br />46 "
<br />48 "
<br />YE5
<br />0.26
<br />DOUBLE HUNG
<br />El
<br />W05
<br />BATH
<br />2
<br />32 "
<br />48 "
<br />0.26
<br />DOUBLE HUNG
<br />WOq
<br />BATH
<br />2
<br />161.
<br />48 "
<br />0.26
<br />DOUBLE HUNG
<br />W10
<br />LAUNDRY
<br />2
<br />24 "
<br />46 "
<br />0.25
<br />DOUBLE HUNG
<br />DOOR AND WINDOW NOTES
<br />1. EVERY SLEEPING ROOM AND HABITABLE ROOMS IN BASEMENTS SHALL
<br />HAVE AT LEAST ONE OPERABLE WINDOW WITH A NET CLEAR
<br />OPENING OF 5.7 SF. THE OPENING HEIGHT SHALL BE 24" MINIMUM
<br />AND WIDTH 20" MINIMUM, WITH A FINISHED SILL HEIGHT NO MORE THE
<br />44" ABOVE THE FLOOR, PER IRC R310.1. IF WINDOW WELLS ARE
<br />NECESSARY THEY SHALL MEET THE REQUIREMENTS OF IRC R310.2.
<br />2. EXTERIOR WINDOWS AND GLASS DOORS SHALL BE DESIGNED TO
<br />RESIST THE DESIGN WIND LOADS SPECIFIED IN TABLE R301.2(2) AND
<br />ADJUSTED FOR HEIGHT AND EXPOSURE PER TABLE R301.2(3).
<br />3. EXTERIOR WINDOWS AND GLASS DOORS SHALL BE TESTED BY AN
<br />APPROVED INDEPENDENT LABORATORY AND BEAR A LABEL
<br />IDENTIFYING MANUFACTURER, PERFORMANCE CHARACTERISTICS
<br />AND APPROVED INSPECTION AGENCY TO INDICATE COMPLIANCE
<br />WITH THE REQUIREMENTS OF IRC SECTION R308
<br />4. GLAZING IN HAZARDOUS LOCATIONS SUCH AS:
<br />a. PANES IN SWINGING, SLIDING, STORM OR BIFOLD DOORS,
<br />b. GLAZING WITHIN 24" OF A DOOR OPENING,
<br />P c. GLAZING IN STAIRWAYS,
<br />d. GLAZING IN SHOWER OR TUB SURROUNDS
<br />e. GLAZING IN GUARDS AND RAILINGS
<br />F. GLAZING CLOSER THAN 18" TO A FLOOR
<br />SHALL BE SAFETY GLAZING OR WIRE REINFORCED, TEMPERED OR
<br />LAMINATED SAFETY GLASS, OR SHATTER RESISTANT PLASTIC PER
<br />j IRC R308.4. GLAZING WITH THE EXPOSED EDGE WITHIN A 24"
<br />ARCH OF THE VERTICAL EDGE OF A DOOR SHALL BE
<br />SAFETY GLAZING PER IRC R308.4
<br />5. GLAZING IN SKYLIGHTS SHALL CONFORM TO IRC R308.6.
<br />MECHANICAL AND ENERGY NOTES
<br />1. ALL WORK SHALL CONFORM TO THE INTERNATIONAL MECHANICAL
<br />CODE, THE 2015 WASHINGTON STATE ENERGY CODE
<br />2. SEE BUILDING SECTION FOR INSULATION RATING AND LOCATION.
<br />3. KITCHEN RANGE FAN, EXHAUST FANS, AND CLOTHES DRYERS SHALL
<br />EXHAUST DIRECTLY TO THE OUTSIDE. VENTS SHALL BE SMOOTH,
<br />NON-COMBUSTIBLE, NONABSORBENT AND EQUIPPED WITH BACK -DRAFT
<br />DAMPER. ALL EXHAUST OUTLETS SHALL TERMINATE AT LEAST
<br />3 FEET FROM ANY OPENING INTO THE BUILDING.
<br />4. ENERGY CODE GENERAL NOTES:
<br />a. ELECTRICAL OR GAS WATER HEATERS SHALL HAVE THE
<br />FOLLOWING:
<br />i. SEPARATE POWER OR GAS SHUTOFF.
<br />ii. NONCOMBUSTIBLE R-10 PAD (UNHEATED SPACES ONLY)
<br />iii. 1987 NAECA LABEL ON TANK
<br />iv. TEMPERATURE SETTING OF 120 DEGREES F.
<br />b. SHOWER AND LAVATORIES SHALL LIMIT FLOW TO 2.6 GPM
<br />c. CEILING INSULATION:
<br />i. BAFFLES TO MAINTAIN 1" AIRSPACE ABOVE INSULATION
<br />ii. BAFFLES TO EXTEND 6" ABOVE BATT INSULATION
<br />iii. BAFFLES TO EXTEND 12" ABOVE LOOSE FILL INSULATION.
<br />d. WALL INSULATION SHALL BE:
<br />i. FACED, STAPLED BATTS, OR
<br />ii.FRICTION FIT UNFACED BATT WITH 4 MIL POLY VAPOR
<br />RETARDER, OR PVA PAINT WITH A DRY SUP PERM RATING
<br />OF 1.0 MAXIMUM.
<br />e. CONCEALED INSULATION SHALL BE PLACED BEHIND SHOWER/TUB
<br />AND BEHIND PARTITION STUD/ CORNER.
<br />Table 406.2
<br />Enerav Credits (2015 Code)
<br />OPTION
<br />DESCRIPTION
<br />CREDIT(S)
<br />Estimated Cost
<br />2c
<br />AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION 2c:
<br />1.5
<br />Compliance based on Section R402.4.1.2: Reduce the tested air leakage to 1.5 air
<br />changes per hour maximum
<br />and
<br />All whole house ventilation requirements as determined by Section M1507.3 of the
<br />International Residential Code shall be met with a heat recovery ventilation system
<br />with minimum sensible heat recovery efficiency of 0.85.
<br />To qualify to claim this credit, the building permit drawings shall specify the option
<br />being selected and shall specify the maximum tested building air leakage and shall
<br />show the heat recovery ventilations stem.
<br />3a
<br />HIGH EFFICIENCY HVAC EQUIPMENT 3a:
<br />1.0
<br />Gas, propane or oil -fired furnace with minimum AFUE of 94%, or
<br />Gas, propane or oiled -fired boiler with minimum AFUE of 92%
<br />To qualify to claim this credit, the building permit drawings shall specify the option
<br />being selected and shall specify the heating equipment type and the minimum
<br />equipment efficiency.
<br />3b b
<br />HIGH EFFICIENCY HVAC EQUIPMENT 3b:
<br />1.0
<br />Air -source heat pump with minimum HSPF of 9.0
<br />To qualify to claim this credit, the building permit drawings shall specify the option
<br />being selected and shall specify the heating equipment type and the minimum
<br />equipment efficiency.
<br />3Cb
<br />HIGH EFFICIENCY HVAC EQUIPMENT 3c:
<br />1.5
<br />Closed -loop ground source heat pump; with a minimum COP of 3.3
<br />or
<br />Open loop water source heat pump with a maximum pumping hydraulic head of 150
<br />feet and minimum COP of 3.6
<br />To qualify to claim this credit, the building permit drawings shall specify the option
<br />being selected and shall specify the heating equipment type and the minimum
<br />equipment efficiency.
<br />3d
<br />HIGH EFFICIENCY HVAC EQUIPMENT 3d:
<br />1.0
<br />Ductless Split System Heat Pumps, Zonal Control: In homes where the primary spat
<br />heating system is zonal electric heating, a ductless heat pump system shall be installe
<br />and provide heating to the largest zone of the housing unit.
<br />To qualify to claim this credit, the building permit drawings shall specify the option
<br />being selected and shall specify the heating equipment type and the minimum
<br />equipment efficiency.
<br />4
<br />HIGH EFFICIENCY HVAC DISTRIBUTION SYSTEM:
<br />1.0
<br />All heating and cooling system components installed inside the conditioned space.
<br />This includes all equipment and distribution system components such as forced air
<br />ducts, hydronic piping, hydrome floor heating loop, convectors and radiators. All
<br />combustion equipment shall be direct vent or sealed combustion.
<br />For forced air ducts: A maximum of 10 linear feet of return ducts and 5 linear feet of
<br />supply ducts may be located outside the conditioned space. All metallic ducts located
<br />outside the conditioned space must have both transverse and longitudinal joints sealed
<br />with mastic. If flex ducts are used, they cannot contain splices. Flex duct connections
<br />must be made with nylon straps and installed using a plastic strapping tensioning tool.
<br />Ducts located outside the conditioned space must be insulated to a minimum of R-8.
<br />Locating system components in conditioned crawl spaces is not permitted under this
<br />option.
<br />Electric resistance heat and ductless heat pumps are not permitted under this option.
<br />Direct combustion heating equipment with AFUE less than 80% is not permitted
<br />under this option.
<br />To qualify to claim this credit, the building permit drawings shall specify the option
<br />being selected and shall specify the heating equipment type and shall show the
<br />location of the heating and cooling equipment and all the ductwork.
<br />Table 406.2
<br />Enerav Credits (2015 Code)
<br />OPTION
<br />DESCRIPTION
<br />CREDIT(S)
<br />Estimated Cost
<br />6
<br />RENEWABLE ELECTRIC ENERGY:
<br />0.5
<br />For each 1200 kWh of electrical generation per each housing unit provided annually
<br />by on -site wind or solar equipment a 0.5 credit shall be allowed, up to 3 credits.
<br />Generation shall be calculated as follows:
<br />For solar electric systems, the design shall be demonstrated to meet this requirement
<br />using the National Renewable Energy Laboratory calculator PV WATTs.
<br />Documentation noting solar access shall be included on the plans.
<br />For wind generation projects designs shall document annual power generation based
<br />on the following factors:
<br />The wind turbine power curve; average annual wind speed at the site; frequency
<br />distribution of the wind speed at the site and height of the tower.
<br />To qualify to claim this credit, the building permit drawings shall specify the option
<br />being selected and shall show the photovoltaic or wind turbine equipment type,
<br />provide documentation of solar and wind access, and include a calculation of the
<br />minimum annual energy power production.
<br />f. FLOOR INSULATION SHALL HAVE VAPOR BARRIER ON THE WARM
<br />SIDE.
<br />g. ATTIC AND CRAWL SPACE ACCESS PANELS SHALL BE INSULATED
<br />AND WEATHER STRIPED.
<br />h. RECESSED LIGHTING FIXTURES TO COMPLY WITH WSEC SECTION
<br />502.4.4
<br />i. VAPOR RETARDERS SHALL BE INSTALLED PER S.502.1.6.
<br />j. 6-MIL BLACK POLYETHYLENE GROUND COVER SHALL BE LAPPED
<br />12" AT JOINT AND EXTEND TO FOUNDATION WALL IN CRAWL
<br />SPACE.
<br />k. ALL EXTERIOR DOORS (EXCEPT 20 MINUTE DOORS) SHALL BE
<br />WEATHER STRIPPED PER S.502.4.3.
<br />I. SERVICE HOT AND COLD WATER PIPING IN UNCONDITIONED
<br />SPACES SHALL BE INSULATED TO THE MINIMUM VALUES
<br />LISTED IN TABLE 5-12 AND SECTION 503.1.1.
<br />m. EACH DWELLING UNIT SHALL BE PROVIDED WITH HEATING
<br />FACILITIES CAPABLE OF MAINTAINING 70 DEGREES F AT A
<br />POINT 3'-0" ABOVE THE FLOOR IN ALL HABITABLE ROOMS
<br />WHEN THE OUTSIDE TEMPERATURE IS AS SET FORTH IN
<br />SECTION 305 WSEC, SECTION 310.11 OF UBC. FUEL BURNING
<br />APPLIANCES SHALL BE LISTED AND LABELED BY AN
<br />APPROVED AGENCY AND INSTALLED AND VENTED
<br />ACCORDING TO SPECIFICATIONS. PROVIDE A MINIMUM CLEAR
<br />WORKING SPACE OF 3" MINIMUM ALONG SIDES, BACK AND
<br />TOP OF APPLIANCE WITH 12" MINIMUM CLEARANCE TOTAL SIDE
<br />TO SIDE.
<br />n. STANDARD AIR LEAKAGE (WSEC SECTION 502.4.3) CAULKING IS
<br />COMPLETE WHEN INSTALLED IN THE FOLLOWING LOCATIONS:
<br />i. BETWEEN SOLE PLATE/ SUB FLOOR.
<br />ii. WIRING, PLUMBING/ DUCT REGISTER PENETRATIONS
<br />iii. RIM JOISTS/ MUD SILLS (HEATED LOWER FLOORS)
<br />iv. PARTITIONS/ STUD PENETRATIONS.
<br />v. LIGHT FIXTURE/ FLUE PENETRATIONS.
<br />vi. AROUND WINDOW AND DOORFRAMES
<br />5. WASHINGTON STATE VENTILATION AND INDOOR AIR
<br />QUALITY CODE NOTES:
<br />a. EACH DWELLING UNIT OR GUEST ROOM SHALL BE EQUIPPED WITH
<br />SOURCE SPECIFIC AND WHOLE HOUSE VENTILATION SYSTEMS
<br />DESIGNED TO SATISFY THE REQUIREMENTS OF THE
<br />WASHINGTON STATE VIASQ CHAPTER 3.
<br />b. MECHANICAL VENTILATION FAN DUCTS SHALL BE 4" OR PROPERLY
<br />SIZED USING VIASQ. TABLE 3.2 AND 3.3.
<br />c. MECHANICAL VENTILATION SYSTEMS SHALL HAVE A TIMER,
<br />DEHUMIDSTAT OR SWITCH PER VIAQ. S.302.3.1. AND
<br />VIASQ.S.302.3.2
<br />Property Address: 3605 Rucker Ave Everett NA g5201-4631
<br />Conditioned Floor Area: 460 5F mate: 04 / 15 120
<br />Builder or registered design professional :
<br />KE5H GHAYDA
<br />Signature: Ke s•G� c4AAW a.
<br />Ceiling: Vaulted R 35 Flours: Over unconditioned space R- 4,1
<br />Attic R- 4q Slab on grade floor R- 10
<br />Wails: Above grade R- 21 Doors: R-
<br />Below, int. R- 21 R-
<br />Below, ext. R- 10 R-
<br />NFRC rating (or)
<br />.Default rating (Appendix A WSEC 2015)
<br />Electric Wall Heaters
<br />Cooli
<br />Windows U- 0.25
<br />Skylights U- 0.50
<br />DHW i Tankless Electric Water Heater
<br />All duct & HVAC in conditione
<br />Air hand er present Qesy
<br />no )
<br />Test TarLet�CFM(r25
<br />Building air leakage target: ACH
<br />SHGC- N/A
<br />SHGC- N/A
<br />E F-2
<br />space ( es no ) Insulation - 8
<br />6
<br />Test Result CFMa 25Pa
<br />< 5.0 - Tested leakage: ACH50
<br />System type: Rated annual generation
<br />I ►'m rl
<br />d. MECHANICAL VENTILATION SYSTEMS SHALL HAVE R-4
<br />INSULATION IN UNCONDITIONED SPACES PLUS BACK -DRAFT
<br />DAMPER. (VIAQ. S.302.5)
<br />e. MECHANICAL VENTILATION SUPPLY DUCTS 1N CONDITIONED
<br />SPACES SHALL HAVE R-4 INSULATION. (VIASQ. S.302.5)
<br />f. SUPPLY DUCTS SHALL HAVE VOLUME DAMPERS, OR EQUIVALENT,
<br />TO BALANCE SYSTEM (WSEC S.503.6)
<br />g. SUPPLY AND RETURN AIR DUCTS SHALL HAVE SEALED DUCT
<br />JOINTS IN UNCONDITIONED SPACES (WSEC S.503.10.2)
<br />h. EXHAUST FANS SHALL BE:
<br />i. FLOW RATED AT 0.25 W.G. STATIC PRESSURE
<br />ii. SOUND RATED AT 1.5 SONES MAXIMUM FOR WHOLE
<br />HOUSE FAN.
<br />iii. INSULATED TO R-4 IN UNCONDITIONED SPACES.
<br />iv. EQUIPPED WITH A BACKDRAFT DAMPER.
<br />i. HVAC PLENUMS, SUPPLY, AND RETURN AIR DUCTS SHALL HAVE
<br />R-8 INSULATION (WSEC TABLE 5-11, ALL OPTIONS)
<br />j. OUTDOOR AIR INLETS: INLETS SHALL BE SCREENED OR
<br />OTHERWISE PROTECTED FROM ENTRY BY INSECTS, LEAVES,
<br />OR OTHER MATERIALS. OUTDOOR AIR INLETS SHALL BE
<br />LOCATED SO AS NOT TO TAKE AIR FROM THE FOLLOWING
<br />AREAS: (VIAQ. S.302.6.1)
<br />i. CLOSER THEN TEN FEET FROM AN APPLIANCE VENT
<br />OUTLET, UNLESS SUCH VENT OUTLET IS THREE FEET
<br />ABOVE THE OUTDOOR AIR INLET.
<br />ii. WHERE IT WILL PICK UP OBJECTIONABLE ODORS, FUMES
<br />OR FLAMMABLE VAPORS.
<br />ii. IN HAZARDOUS OR UNSANITARY LOCATIONS.
<br />iv. IN A ROOM OR SPACE HAVING FUEL -BURNING.
<br />APPLIANCES.
<br />v. CLOSER THEN TEN FEET FROM A VENT OPENING TO A
<br />PLUMBING DRAINAGE SYSTEM UNLESS THE VENT
<br />A. OPENING IS AT LEAST THREE FEET ABOVE THE AIR INLET.
<br />IN AN ATTIC, CRAWL SPACE OR GARAGE.
<br />k. SOURCE SPECIFIC VENTILATION SHALL BE PROVIDED IN EACH
<br />KITCHEN, BATHROOM, WATER CLOSET, LAUNDRY ROOM, SPA,
<br />INDOOR SWIMMING POOL ENCLOSURE AND ANY OTHER
<br />ROOMS WERE EXCESS WATER VAPOR OR ODOR IS
<br />PRODUCED.
<br />I. WHOLE HOUSE VENTILATION SYSTEMS: EACH DWELLING UNIT
<br />SHALL BE EQUIPPED WITH A WHOLE HOUSE VENTILATION
<br />SYSTEM THAT SHALL BE CAPABLE OF PROVIDING AT LEAST
<br />0.35 AIR CHANGES PER HOUR, BUT NOT LESS THEN 15 CFM PER
<br />BEDROOM PLUS AND ADDITION 15 CFM. WHOLE HOUSE
<br />VENTILATION SYSTEM SHALL SUPPLY OUTDOOR AIR TO ALL
<br />HABITABLE ROOMS THROUGH INDIVIDUAL OUTDOOR AIR
<br />INLETS, FORCED AIR HEATING SYSTEMS, DUCTING OR
<br />EQUIVALENT.
<br />,,,Ty OF EVERETT
<br />REVIEWED FOR PER P17
<br />W
<br />m
<br />Z
<br />W
<br />W
<br />W
<br />0 0
<br />N N
<br />0
<br />N
<br />U
<br />Y
<br />N C)
<br />0 0
<br />N
<br />0
<br />m
<br />Z
<br />H
<br /><( W
<br />W
<br />0 ry
<br />01f
<br />0
<br />v
<br />l
<br />V `
<br />V
<br />�. r z
<br />
|