Laserfiche WebLink
GENERAL STRUCTURAL NOTES: <br />CRITERIA: <br />1.1 All Materials, workmanship, design, and construction shall conform to the drawings, specifications, and the International Building Code (IBC), 2015 Edition. <br />1.2 Design Loading Criteria <br />The Design Loading of the Structure is as follows: <br />Live Loads (in accordance with IBC Table 1607.1) <br />Occupancy or Use <br />Uniform Live <br />Load <br />Concentrated <br />Live Load <br />Notes <br />Floor, Residential <br />40-psf <br />- <br />Wind Design Data <br />ASCE 7-10, Chapter 28: Simplified Envelope Procedure <br />Ultimate Design Wind Speed (3-sec gust), Volt <br />Nominal Wind Speed, Vasd <br />110-mph <br />85-mph <br />Risk Catagory <br />II <br />Wind Exposure <br />B <br />Internal Pressure Coefficient <br />N/A <br />Exterior Components and Cladding <br />25-psf <br />Topographical Factor, Kt <br />1.00 <br />Snow Loads <br />(ASCE 7-10, Chapter 7) <br />Ground Snow Load, P9 <br />25-psf <br />Flat Roof Snow Load, Pf = 0.7 Ce Ct Is P9 <br />25-psf <br />* Snow Exposure Factor, Ce <br />1.0 <br />* Snow Load Importance Factor, IS <br />1.0 <br />* Thermal Factor, Ct <br />1.2 <br />See Drawings for Additional Loading Criteria. <br />Seismic Design Data <br />ASCE 7-10, Section 12.8: Equivalent Lateral Force Procedure <br />Risk Catagory <br />II <br />Seismic Importance Factor, le <br />1.0 <br />Mapped Spect. Accel., Short Period, Ss <br />Mapped Spect. Accel., 1-Sec, S1 <br />1.326 <br />0.504 <br />Site Class <br />D <br />Spectral Response Coeff., Short Period, SDS <br />Spectral ResponseCoeff., 1-Sec, SD1 <br />0.880 <br />0.500 <br />Seismic Design Catagory <br />D <br />Basic Seismic -Force -Resistance System <br />Ply. Shear Walls <br />Response Modification Factor, R <br />6.5 <br />Seismic Response Coefficient, Cs <br />0.13 <br />Design Base Shear, V <br />0.13 x Weight <br />1.3 Structural Drawings shall be used in conjunction with all other project documents for bidding and construction. Contractor shall verify dimensions and <br />conditions for compatibility and shall notify architect of all discrepancies prior to construction. <br />1.4 Contractor shall provide Temporary Bracing for the structure and structural components until all final connections have been completed in accordance with <br />the drawings. <br />1.5 Contractor shall be responsible for all safety precautions and the methods, techniques, sequences or procedures required to perform the work. <br />1.6 Contractor -initiated changes shall be submitted in writing to the Architect and Structural Engineer for approval prior to fabrication or construction. Changes <br />shown on shop drawings only will not satisfy this requirement. <br />1.7 Drawings indicate general and typical details of construction. Where conditions are not specifically indicated but are of similar character to details shown, <br />similar details of construction shall be used, subject to review and approval by the Architect and the Structural Engineer. <br />1.8 All structural systems composed of components to be field erected shall be supervised by the Supplier during manufacturing, delivery, handling, storage and <br />erection in accordance with instructions prepared by the Supplier. <br />WOOD: <br />6.1 Framing Lumber shall be kiln dried or MC-19, and graded and marked in conformance with WCLB Standard Grading Rules for West Coast Lumber No. 17. <br />Unless otherwise noted, furnish to the following minimum standards: <br />Member Use <br />Size <br />Species <br />Grade <br />Studs <br />2x, 3x <br />Hem -Fir or SPF <br />STUD <br />Beams <br />4x <br />Douglas Fir -Larch <br />No. 2 <br />6.2 Glued Laminated Members shall be fabricated in conformance with ASTM and AITC Standards. Each member shall bear an AITC Identification Mark and <br />shall be accompanied by an AITC certificate of conformance. Furnish to the following minimum standards: <br />Member Use <br />Combination <br />Species <br />Fb,1 <br />Fb,. <br />F,iX <br />FAX <br />EX <br />Beams <br />24F-V4 <br />DF/DF <br />2400-psi <br />1850-psi <br />650-psi <br />265-psi <br />1800-ksi <br />Camber all glulam beams to 3,500' radius, unless otherwise noted. Glued laminated members exposed to <br />weather or moisture shall be treated with an approved preservative. <br />6.3 Roof, Floor & Wall Sheathing shall be APA Rated, Exterior or Exposure 1 Plywood or OSB manufactured under the provisions of Voluntary Product <br />Standards DOC PS-1 or DOC PS-2, or APA PRP-108 Performance Standards and Policies for Structural Use Panels. See Drawings for thickness, span <br />rating, and nailing requirements. Unless otherwise noted, wall sheathing shall be'/2" (nominal) with Span Rating of 24/0. Glue floor sheathing to all <br />supporting members with adhesive conforming to APA Specification AFG-01. <br />6.4 Wood members shall be protected against decay and termites in accordance with IBC Section 2304.12. Where required, members shall be naturally durable <br />species or shall be treated with waterborne preservatives wood in accordance with American Wood Protection Association specification AWPA U1. Members <br />shall be clearly labeled. Modifed treated members (ripped or end cut) shall be field treated in accordance with specification AWPA M4. <br />6.5 Timber Connectors and Proprietary Fasteners shall be "Strong -Tie" by Simpson Company, as specified in their current catalog. Provide number and size of <br />fasteners as specified by manufacturer. Connectors shall be installed in accordance with the manufacturer's instructions. Where connector straps connect <br />two members, center strap on joint and provide number and size of fasteners as specified by manufacturer, with equal number and size of fasteners in each <br />member. <br />Alternate hardware manufacturer substitutions, such as USP Connectors, shall be [CC approval for equal or greater load capacities. All joist hangers and <br />other hardware shall be compatible in size with specified framing members. See Hanger Conversion Table for pre -approved substitutions. <br />Timber Connectors and their fasteners shall be protected from corrosion in accordance with manufacturer's recommendations or ASTM A 653, Type G185. <br />6.6 Dowel -Type Fasteners (Bolts, Lag Screws, Wood Screws and Nails) shall conform to Sections 11 and 12 of the ANSI/AWC NDS-2015. <br />Dowel Type Fastener <br />Grade <br />Requirements at Exterior Use or <br />when in Contact w/ Treated Lumber <br />Installation <br />All-Thread/Threaded Rod <br />ASTM F1554 <br />ASTM B 695, Class 55 Galvanized <br />ANSI/AWCNDS-2015 Section 12.1.3 <br />or Stainless Steel <br />Hole = Rod 0 + (1/32" to 1/16") <br />Washer @ Each Nut <br />Nails <br />ASTM F1667 <br />ASTM A 153 Galvanized <br />ANSI/AWC NDS-2015 Section 12.1.6 <br />or Stainless Steel <br />Avoid Overdriving or Underdriving; Avoid Wood Splitting <br />Toenails 300, 1/3 Nail Length from Joint <br />Nails specified on the drawings shall be as follows: <br />Nail Use <br />Penny <br />Weight <br />Grade <br />Framing Nails <br />12d Box <br />0.131"0 x 31/4" <br />Sheathing Nails <br />8d Common <br />0.131 "0 x 2%2' <br />All Metal Fasteners exposed to weather or in contact with treated wood shall be protected from corrosion according to table above. Nuts and bolts exposed <br />to weather or in contact with treated wood shall be galvanized in accordance with ASTM A 153 or Stainless Steel. See above for Proprietary Fastener <br />requirements. Do not substitute standard Dowel -Type Fasteners for Proprietary Fasteners unless specifically allowed. <br />6.7 Wood Framing Notes: The following apply unless otherwise noted on the drawings: <br />A. All wood framing details shall be constructed to the minimum standards of the IBC. Nailing not specified on the drawings shall conform to IBC Table <br />2304.10.1 or ICC ES ESR-1539. Coordinate the size and location of all openings with Mechanical and Architectural Drawings. <br />B. Wall Framing: Stud wall size and spacing shall be in accordance with the plan notes. Two studs minimum shall be provided at the ends of all walls, at <br />each side of all openings, and at the ends of all beams and headers. <br />C. Individual members of Built -Up stud posts shall be nailed to each other with framing nails @ 12"oc, staggered. Individual members of Built -Up joist <br />beams shall be nailed to each other with framing nails @ 12" oc; staggered. <br />D. Floor Framing: Provide solid blocking at all bearing points. Toenail joists to supports with two framing nails. Attach timber joists to flush headers or <br />beams with metal joist hangers in accordance with notes above. <br />QUALITY ASSURANCE: <br />7.1 Structural Observation is not required. <br />V <br />coD <br />O <br />O <br />� <br />4-1 <br />_ <br />O <br />U <br />IN <br />CD <br />O <br />� <br />N <br />W <br />'N <br />N <br />Vr/ <br />C <br />ENGINEERING P.S. <br />19011 Woodinville Snohomish Road NE, Suite 100 <br />WOODINVILLE, WA 98072-4436 <br />PHONE:425-814-8448 FAX:425-821-2120 <br />PROJECT NUMBER: <br />PROJECT MANAGER: <br />BTL <br />DRAWN BY: <br />BDS <br />DATE: <br />11-14-19 <br />REVISIONS: <br />I <br />REVISIONS 1 01-21-2020 <br />rl i <br />� p 1 <br />CITY OF �VERETT <br />Permit Services <br />GENERAL <br />STRUCTURAL <br />NOTES <br />S1.0 <br />