GENERAL STRUCTURAL NOTES: <br />CRITERIA: <br />1.1 All Materials, workmanship, design, and construction shall conform to the drawings, specifications, and the lnternatlonal Building Code (IBC), 2015 Edition. <br />1.2 Design Loading Criteria <br />The Design Loading of the Structure is as follows: <br />Live Loads (in accordance with IEC Table 1607.1) <br />Occupancy or Use <br />Uniform Live <br />Load <br />Concentrated <br />Live Load <br />Notes <br />Floor, Residential <br />40-psf <br />Wind, Design Data <br />ASCE 7-10, Chapter 28: Simplified Envelope Procedure <br />Ultimate Design Wind Speed (3-sec gust), Vlt I I 0-mph <br />Nominai Wind Speed, Vasd 85-mph <br />Risk Catagory 11l <br />Wind Exposure B <br />internal Pressure Coefficient N/A <br />Exterior Components and Cladding 25-psf <br />Topographical Factor, Kt 1.00 <br />SnowLoads <br />(ASCE 7-10, Chapter 7) <br />Ground Snow Load, P9 25-psf <br />Fiat Roof Snow Load, Pf = 0.7 CL Ct is P9 25-psf <br />• Snow Exposure Factor, Ce 1.0 <br />• Snow Load Importance Factor, is 1.0 <br />Thermal Factor, Ct 1.2 <br />See Drawings for Additional Loading Criteria. <br />Seismic Design Data <br />ASCE 7-10, Section 12.8: Equivalent Lateral Force Procedure <br />Risk Catagory <br />ii <br />Seismic importance Factor, l, <br />1.0 <br />Mapped Spect. Accell., Short Period, Ss <br />Mapped Spect. Accel., 1-Sec, S, <br />1.326 <br />0.504 <br />Site Class <br />D <br />Spectral Response Coeff., Short Period, SDS <br />Spectral Response Coeff., 1-Sec, SDI <br />0.880 <br />0.500 <br />Seismic Design Catagory <br />D <br />Basic Seismic -Force -Resistance System <br />Ply. Shear Walls <br />Response Modification Factor, R <br />6.5 <br />Seismic Response Coefficient, Cs <br />0.13 <br />Design Base Shear, V <br />0. <br />1.3 Structural Drawings shall be used in conjunction with all other project documents for bidding and construction. Contractor shall verify dimensions and <br />conditions for compatibility and shall notify architect of all discrepancies prior to construction. <br />1A Contractor shall provide Temporary Bracing for the structure and structural components until all final connections have been completed in accordance with <br />the drawings. <br />1.5 Contractor shall be responsible for all safety precautions and the methods, techniques, sequences or procedures required to perform the work <br />1.6 Contractor -initiated changes shall be submitted in writing to the Architect and Structural Engineer for approval prior to fabrication or construction. Changes <br />shown on shop drawings only will not satisfy this requirement. <br />1.7 Drawings indicate general and typical details of construction. Where conditions are not specifically indicated but are of similar character to details shown, <br />similar details of construction shall be used, subject to review and approval by the Architect and the Structural Engineer. <br />1.8 All structural systerns composed of components to be field erected shall be supervised by the Supplier during manufacturing, defivery, handling, storage and <br />erection in accordance with instructions prepared by the Supplier. <br />WOOD: <br />6.1 Framing Lumber shall be kiln dried or MC-1 9, and graded and marked in conformance with VVCLB Standard Grading Rules for West Coast Lumber No. 17. <br />Unless otherwise noted, furnish to the following minimum standards: <br />Member Use <br />Size <br />Species <br />Grade <br />Studs <br />2x, 3x <br />Hem -Fir or SPF <br />STUD <br />Beams <br />4.x <br />Douglas Fir -Larch <br />No. 2 <br />5.2 Glued Laminated Members shall be fabricated in conformance with ASTM and AlTC Standards. Each member shall bear an AlTC identification Mark and <br />shall be accompanied by an AITC certificate of conformance. Furnish to the following minimum standards: <br />Mamber Use <br />Combination <br />Species <br />Fld,,, <br />Fb.- <br />FLx <br />Fvx <br />Ex <br />Beams <br />24F-V4 <br />DFIDF <br />2400-psi <br />1850-psi <br />650-psi <br />265-psi <br />1800-ksi <br />Camber all glulam beams to 3,500'radius, unless otherwise noted. Glued laminated members exposed to <br />weather or moisture shall be treated with an approved preservative. <br />6.3 Roof, Floor & Wall Sheathing shall be APA Rated, Exterior or Exposure I Plywood or OSB manufactured under the provisions of Voluntary Product <br />Standards DOC PS-1 or DOC PS-2, or APA PRP-1 08 Performance Standards and Policies for Structural ,Use Panels. See Drawings for thickness, span <br />rating, and nailing requirements. Unless otherwise noted, wall sheathing shall be V2" (nominal) with Span Rating of 24/0. Glue floor sheathing to all <br />supporting members with adhesive conforming to APA Specification AFG-01 . <br />6.4 Wood members shall be protected against decay and termites in accordance with lBC Section 2304.12. Where required, members shall be naturally durable <br />species or shall be treated with waterborne preservatives wood in accordance with American Wood Protection Association specification AWPA U1. Members <br />shall be clearly labeled. Modifed treated members (ripped or end cut) shall be field treated in accordance with specification AWPA M4. <br />6.5 Timber Connectors and Proprietary Fasteners shall be "Strong -Tie" by Simpson Company, as specified in their current catalog. Provide number and size of <br />fasteners as specified by manufacturer. Connectors shall be installed in accordance with the manufacturer's instructions. Where connector straps connect <br />two members, center strap on joint and provide number and size of fasteners as specified by manufacturer, with equal number and size of fasteners in each <br />member. <br />Alternate hardware manufacturer substitutions, such as USP Connectors, shall be lCC approval for equal or greater load capacities. All joist hangers and <br />other hardware shall be compatibie in size with specified framing members. See Hanger Conversion Table for pre -approved substitutions. <br />Timber Connectors and their fasteners shall be protected from corrosion in accordance with manufacturer's recommendations or ASTM A 653, Type G185. <br />6.8 Dowel -Type Fasteners (Bolts, Lag Screws, Wood Screws and Nails) shall conform to Sections 11 and 12 of the ANSUAWC NDS-2015. <br />Dowel Type Fastener <br />Grade <br />Requirements at Exterior Use or <br />when in Contact wl Treated Lumber <br />Installation <br />X l-Th read/Th read ed Rod <br />ASTNAI F1554 <br />ASTM 8 695, Class 55 Galvanized <br />ANSI/AWC; NDS-2015 Section 12.1.3 <br />or Stainless Steel <br />Hole = Rod 0 + 0 /32" to 1/16") <br />Washer @ Each Nut <br />Nails <br />ASTM F1667 <br />ASTM A 153 Galvanized <br />ANSl/AWC NDS-2015 Section 12.1.6 <br />or Stainless Steel <br />Avoid Overdriving or Underdriving; Avoid Wood Splitting <br />Toenails 300, 1/3 Nail Length from Joint <br />Nails specified on the drawings shall) be as follows: <br />bait Use <br />Penny <br />Weight <br />Grade <br />Framing Nails <br />12d Box <br />0 . 131 "0 x 3Y4" <br />Sheathing Nails <br />Sol Common <br />0.131"0 x 2Y2" <br />All Metal Fasteners exposed to weather or in contact with treated wood shall be protected from corrosion according to table above. Nuts and bolts exposed <br />to weather or in contact with treated wood shall be galvanized in accordance with ASTM A 153 or Stainless Steel. See above for Proprietary Fastener <br />requirements. Do not substitute standard Dowell -Type Fasteners for Proprietary Fasteners unless specifically allowed. <br />6.7 Wood Framing Notes: The following apply unless otherwise noted on the drawings: <br />A. All wood framing details shall be constructed to the minimum standards of the IBC. Nailing not specified on the drawings shall conform to IBC Table <br />2304. 10.1 or lCC ES ESR-1 539. Coordinate the size and location of all openings with Mechanical and Architectural Drawings. <br />B. Wall Framing: Stud wall size and spacing shall be in accordance with the plan notes. Two studs minimum shall be provided at the ends of all wails, at <br />each side of all openings, and at the ends of all beams and headers. <br />C. individual members of Built -Up stud posts shall be nailed to each other with framing nails @ 12"oc, staggered. individual members of Built -Up joist <br />beams shall be nailed to each other with framing nails @ 12"oe, staggered. <br />D. Floor Framing: Provide solid blocking at all bearing points. Toenail joists to supports with two framing nails. Attach timber joists to flush headers or <br />beams with metal joist hangers in accordance with notes above. <br />QUALITY ASSURANCE: <br />7.1 Structural Observation is not required. <br />C <br />ce) <br />C) <br />U <br />CD <br />U) <br />N <br />4m4 <br />U <br />6 <br />< <br />- (D <br />> <br />CD <br />N <br />co <br />101 I 2M1 <br />11 <br />A <br />4 11 wgi 11 ing: <br />-ENGINEERING P.S. <br />19011 Woodinville Snohomish Road NE, Suite 100 <br />WOODINVILLE, WA 98072-4436 <br />PHONF2.4251 2fll <br />PROJECT NUMBER <br />PROJECT MANAGER: <br />BTL <br />DRAWN BY: <br />BDS <br />DATE: <br />11-14-19 <br />REVISIONS: <br />pp <br />Z <br />u <br />U <br />P M <br />V <br />GENERAL <br />STRUCTURAL <br />NOTES <br />MR. <br />