NOTES AND SPECIFICATIONS APPLY TO WORK PERFORMED, AND DO NOT APPLY TO AREAS THAT <br />ARE NOT DISTURBED. <br />THE GENERAL CONTRACTOR ASSUMES RESPONSIBILITY FOR ALL WORK PERFORMED ON THE <br />SITE, WHETHER BY SUBCONTRACTORS, TENANTS OR OTHERS. <br />THE GENERAL CONTRACTOR, SUBCONTRACTORS AND MANUFACTURER SHALL COMPLY WITH <br />THE CURRENT EDITION OF THE INTERNATIONAL BUILDING CODE, OREGON STRUCTURAL <br />SPECIALTIES CODE, AND ALL ADDITIONAL STATEAND LOCAL CODE REQUIREMENTS. THE <br />CONTRACTOR/MANUFACTURER SHALL ASSUME FULL RESPONSIBILITY FOR ANY WORK <br />KNOWINGLY PERFORMED CONTRARY TO SUCH LAWS, ORDINANCES OR REGULATIONS. <br />THE GENERAL CONTRACTOR SHALL PERFORM COORDINATION WITH ALL UTILITY COMPANIES AND <br />STATE SERVICE AUTHORITIES. <br />WRITTEN DIMENSIONS ON DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. <br />THE MANUFACTURER AND CONTRACTOR SHALL VERIFY AND ARE RESPONSIBLE FOR ALL <br />DIMENSIONS (INCLUDING ROUGH OPENINGS) AND CONDITIONS ON THE JOB AND MUST NOTIFY <br />ARETE' DESING WITH ANY VARIATIONS FROM THESE DRAWINGS. <br />THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING DISTRIBUTION OF DRAWINGS TO ALL <br />SUBCONTRACTORS, AND ALL WORK IS BASED ON THE LATEST ISSUE OF DRAWINGS. ALL <br />STAMPED DRAWINGS ISSUED BY ARETE' DESING TO BE CONSIDERED CONTRACT DOCUMENTS. <br />THE GENERAL CONTRACTOR AND MANUFACTURER ARE RESPONSIBLE FOR THE DESIGN AND <br />PROPER FUNCTION OF THE PLUMBING, MECHANICAL, EQUIPMENT, AND ELECTRICAL SYSTEMS. <br />THE GENERAL CONTRACTOR AND MANUFACTURER SHALL NOTIFY ARETE' DESING WITH ANY <br />PLAN CHANGES REQUIRED FOR THE PROPER DESIGN AND FUNCTION OF THESE SYSTEMS. <br />ARETE' DESING SHALL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS AND METHODS, ACTS <br />OR OMISSIONS OF THE GENERAL CONTRACTOR, SUB -CONTRACTOR, OR MANUFACTURER, OR <br />FAILURE OF ANY OF THEM TO CARRY OUT WORK IN ACCORDANCE WITH THE CONSTRUCTION <br />DOCUMENTS. ANY ERROR OR OMMISSION DISCOVERED IN THE CONSTRUCTION DOCUMENTS <br />SHALL BE BROUGHT TO THE ATTENTION OF ARETE' DESING BY WRITTEN NOTICE BEFORE <br />PROCEEDING WITH WORK. REASONABLE TIME NOT ALLOWED ARETE' DESING TO CORRECT THE <br />ERROR OR OMMISSION SHALL PLACE THE BURDEN OF COST AND LIABILITY FROM SUCH DEFECT <br />UPON THE CONTRACTOR AND MANUFACTURER. <br />SEE STRUCTURAL DRAWINGS SHEETS FOR STRUCTURAL NOTES, MATERIALAND INSPECTION <br />REQUIREMENTS, AND TYPICAL DETAILS OF CONSTRUCTION NOT SPECIFICALLY REFERENCED IN <br />THESE NOTES. <br />ALL MATERIALS AND WORKMANSHIP SHALL BE NEW AND THE BEST OF ITS CLASS AND KIND. <br />DO NOT INSTALL MATERIALS OR COMPLETE ASSEMBLIES WHICH MAY HARBOR, CONTAMINATE, OR <br />OTHERWISE BE A SOURCE OF HARMFUL CHEMICALS, OR THAT MAY CAUSE CORROSION, ROT OR <br />DAMAGE TO INHABITANTS, SITE OR OTHER PORTIONS OF THIS OR OTHER BUILDING(S). <br />PROCURE, STORE, INSTALL & FINISH ALL MATERIALS AND ASSEMBLIES IN ACCORDANCE TO <br />MANUFACTURER'S SPECIFICATIONS, INSTALLATION MANUALS AND OPERATING INSTRUCTIONS. <br />PROVIDE COPIES OF ALL MANUFACTURER'S SPECIFICATIONS AND INSTALLATION MANUALS TO <br />ARETE' DESING AND OWNER IN ASSEMBLED PROJECT CLOSE-OUT BINDER. <br />THE SITE AND BUILDINGS ARE NOT KNOW TO HAVE ASBESTOS OR OTHER HARMFUL MATERIALS <br />OR CHEMICALS. NO TESTING FOR ANY HARMFUL MATERIALS HAS BEEN DONE BY ARETE' DESING. <br />NOTIFY ARETE' DESING IMMEDIATELY IF A HARMFUL SUBSTANCE IS SUSPECTED OR KNOWN TO <br />EXIST. ALL HARMFUL MATERIALS ARE TO BE TESTED FOR AND OR ABATED PER REQUIREMENTS <br />OF LAW BY A LICENSED COMPANY. ARETE' DESING IS NOT RESPONSIBLE FOR UNWARY <br />PRACTICES BY CONTRACTOR. <br />ALL SUB -CONTRACTORS SHALL COOPERATE WITH EACH OTHER IN THE VARIOUS PARTS OF THE <br />WORK SO THAT THE WORK OF ONE WILL NOT BE DELAYED MORE THAN ABSOLUTELY NECESSARY <br />BY THE WORK OF ANOTHER. <br />EACH SUB -CONTRACTOR SHALL CLEAN UP AND REMOVE FROM THE PREMISES, FROM TIME TO <br />TIME, ALL WASTE MATERIALS AND DEBRIS WHICH MAYACCUMULATE IN THE BUILDING OR ABOUT <br />THE PREMISES AS A RESULT OF HIS WORK. <br />EACH SUB -CONTRACTOR SHALL MAINTAIN INSURANCE AS STATED UNDER THE WORKMAN'S <br />COMPENSATION ACT AND APPROPRIATE PUBLIC LIABILITY. <br />ON -SITE VERIFICATION OF ALL CONDITIONS AND LOCATING OF BUILDING OR BUILDINGS ON THE <br />PROPERTY, SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. <br />THE GENERAL CONTRACTOR SHALL PERSONALLY INSPECT THE SITE OF THE PROPOSED WORK <br />IN ORDER TO BECOME FAMILIAR WITH ALL THE CONDITIONS UNDER WHICH THE WORK IS TO BE <br />PERFORMED, <br />IF WORK CANNOT BE EXECUTED PER DRAWINGS, CONFER WITH ARETE' DESING FOR OTHER <br />SOLUTION(S) PRIOR TO PROCEEDING. <br />THE CONTRACTOR IS RESPONSIBLE FOR THE ABILITY OF HIS CHOSEN SUBCONTRACTORS TO <br />COMPLETE THE WORK AS SPECIFIED AND PROVIDE WARRANTIES FOR ALL WORK. <br />SUBMITTALS <br />PROVIDE ARETE' DESING OF EACH FINISH MATERIALAS SPECIFIED. SAMPLE MUST BE FROM <br />SAME LOT AS LOT ORDERED, IF APPLICABLE. <br />SUPPLY MINIMUM 6" X 6" SUBMITTAL WITH FINISH COATINGS AS SPECIFIED, IF APPLICABLE. <br />PAINT: PROVIDE DRAW -DOWNS OF EACH PAINT COLOR AND TYPE AS SPECIFIED. PROVIDE TX 3' <br />MOCK-UP ON SITE OF APPROVED PAINT COLORS ON APPLICABLE WALLS ON SITE. ARETE' <br />DESING AND OWNER(S) TO APPROVE OF COLORS PRIOR TO FINAL APPLICATION. <br />FABRICS: ORDER FABRICS OR PLACE ON -HOLD ATTHE INCEPTION OF PROJECT. ORDER <br />CUTTINGS AND PROVIDE TO ARETE' DESING FOR APPROVAL. FABRICS TO BE FROM SAME DYE <br />LOT AS APPROVED CUTTING. ORDER ENOUGH FABRIC FOR PROPER ALIGNMENT ON FINISHED <br />PIECES. <br />SUBSTITUTIONS <br />NO SUBSTITUTIONS OF PROPRIETARY SPECIFICATIONS WILL BE ALLOWED UNLESS SUBMITTED <br />TO ARETE' DESING IN SUFFICIENT TIME FOR REVIEW, AND APPROVED BY ARETE' DESING. <br />SUBMIT LITERATURE AND SAMPLES. <br />EXCAVATINGAND GRADING GENERAL NOTES <br />VERIFY SLOPE OF EXISTING TOPOGRAPHY. <br />REMOVE ALL EXISTING OBSTRUCTIONS THAT MAY INCLUDE FOOTINGS, SLABS, TREES, ROCKS, <br />ROOTS, ETC. <br />PROVIDE 3RD PARTY ENGINEER'S REPORT ON SOILS AFTER EXCAVATION, SEE ENGINEER'S NOTE <br />PAGE S1.0. <br />SLOPE CRAWL SPACE TO DRAIN. MAXIMUM SLOPE IS 2 HORIZ. TO 1 VERT. BETWEEN FOOTINGS AT <br />DIFFERENT ELEVATIONS. <br />FILL, PUDDLE AND TAMP UNDER ALL SLABS TO THE PROPER ELEVATION, AS NOTED. <br />ALL BACKFILL SHALL BE TAMPED OR COMPACTED IN 6" LAYERS WHERE NECESSARY. FOR <br />STRUCTURAL FILL, SEE ENGINEER'S DRAWINGS AND CALCULATIONS. <br />ALL BACKFILL SHALL BE RETURNED IN ACCORDANCE WITH THE LANDLORD'S CRITERIA. <br />ANY FILL OVER 12" MUST BE COMPACTED WITH ENGINEER'S COMPACTION REQUIREMENTS <br />DO NOT BACKFILL FOUNDATION WALLS UNTIL FOUNDATION WALLS HAVE ACHIEVED DESIGN <br />STRENGTH AS LISTED IN STRUCTURAL NOTES. <br />ALL SURPLUS EARTH NOT USED FOR BACKFILL OR SITE GRADING SHALL BE REMOVED FROM <br />SITE. <br />ALL SURFACE DRAINAGE OF LOT TO BE CONDUCTED TO STREET VIA 2% GRADE OR <br />UNDERGROUND DRAIN LINES. SEE PLOT PLAN. <br />ROOF GUTTER AND DOWNSPOUT DRAINAGE TO BE CONDUCTED TO STORMWATER MITIGATION <br />SYSTEMS. SEE SITE PLAN & SPECIFICATIONS. <br />CONCRETE AND FOUNDATION GENERAL NOTES <br />ALL FOOTINGS TO REST ON CLEAN, FIRM, UNDISTURBED SOIL OR COMPACTED FILL. STEP <br />FOUNDATION FOOTINGS AS REQUIRED MAINTAINING DEPTH BELOW FINISH GRADES. <br />ALL REINFORCING STEEL & FOUNDATION STRUCTURAL DESIGN PER ENGINEER'S DRAWINGS AND <br />CALCULATIONS. <br />NO FOOTING SHALL BE UNDERCUT CLOSER THAN 1: 1, SEE STRUCTURAL NOTES. <br />ALL FOOTINGS TO BE POURED ON UNDISTURBED SOIL OR COMPACT FILL. <br />CONCRETE FORMS SHALL BE DRESSED LUMBER WITH LEVELING STRIPS PROVIDED WHERE <br />REQUIRED, ROUGH LUMBER MAY BE USED AS FORMS BELOW FINISHED GRADE. <br />FORMS SHALL BE LEFT IN PLACE UNTIL CONCRETE HAS ATTAINED PERMANENT SET. <br />PROVIDE BLOCK -OUTS AS REQUIRED FOR SEWER, WATER, ELECTRICAL AND VENTING. VERIFY <br />LOCATION WITH GENERAL CONTRACTOR. <br />PROVIDE A MINIMUM 18" CRAWLSPACE CLEARANCE BELOW WOOD FLOOR JOIST AND 121, BELOW <br />WOOD BEAMS. <br />PROVIDE 6MIL MINIMUM POLY VAPOR BARRIER CONTINUOUSLY ABOVE EXPOSED EARTH IN <br />CRAWLSPACE AREAS & UNDER SLABS, WRAPPING VAPOR BARRIER UP FOOTINGS AT EDGES. <br />OVERLAP VAPOR BARRIER BY 18" MIN AT JOINTS. <br />SEE FOUNDATION PLAN FOR UNDER FLOOR VENTING LOCATIONS. PROVIDE INSECT SCREENS AT <br />ALL FOUNDATION OPENINGS. PROVIDE REQUIRED SQUARE INCHES OF VENTING AREA PER <br />CODE. <br />WATERPROOF ALL RETAINING WALLS & BASEMENT FOUNDATION WALLS ON EXTERIOR OF <br />CONCRETE SURFACE, SEE SPECIFICATIONS FOR MATERIAL. <br />PROVIDE DRAIN MATT AT ALL RETAINING WALLS & BASEMENT WALLS TO WICK ASSIST IN THE <br />REMOVAL OF WATER FROM BEHIND THE WALLS. <br />PROVIDE PERFORATED DRAIN PIPE AT BASE OF ALL RETAINING WALL FOOTINGS. PROVIDE SIZE, <br />AS REQUIRED, 4" DIAMETER MINIMUM. PROVIDE FILTER FABRIC WRAPAROUND PIPE AND 18" <br />SQUARE MINIMUM DRAIN ROCK. FULLY WRAP DRAIN ROCK WITH FILTER FABRIC, 18" CAP <br />MINIMUM, BEFORE BACKFILLING. CONDUCT PERFORATED PIPE TO STREET OR CITY COMBINED <br />SANITARY SEWER VIA SOLID PIPE. <br />LUMBER AND FRAMING GENERAL NOTES <br />PROVIDE 30# BUILDING PAPER UNDER ALL BEARING PLATES. BEARING PLATES TO BE PRESSURE <br />TREATED. <br />PROVIDE SOLID BLOCKING UNDER ALL BEARING WALLS PERPENDICULAR TO JOISTS AND OTHER <br />BEARING POINTS NOT OTHERWISE PROVIDED WITH SUPPORT. FLOOR JOISTS AND RAFTERS TO <br />HAVE SOLID BLOCKING AT ENDS OF EXPOSED SPANS AND AT MID -SPANS, IF SPAN IS GREATER <br />THAN 10 FEET. <br />ALL WOOD IN CONTACT WITH CONCRETE TO BE PRESSURE TREATED OR PROVIDE'/2" AIR SPACE. <br />ALL PLYWOOD TO HAVE SURFACE GRAIN PERPENDICULAR TO SUPPORTS. <br />STAGGER ALL JOINTS OF ALL PLYWOOD PANELS. <br />ALL NAILING TO CONFORM TO NAILING SCHEDULE. SEE FRAMING PLANS FOR ADDITIONAL <br />NOTES. <br />DOUBLE JOISTS UNDER ALL PARALLEL PARTITIONS. <br />PERFORMANCE SPECIFICATION ITEMS MUST BE SUPPLIED BY CONTRACTOR FROM ANY <br />MANUFACTURER THAT MEETS THE SPECIFICATION CRITERIA. THIS NOTE ALSO APPLIES TO ALL <br />SUBCONTRACTORS. <br />THERMAL & MOISTURE PROTECTION GENERAL NOTES <br />PROVIDE 15# TAR PAPER AS WALL VAPOR BARRIER, OR AS APPROVED BY LOCAL CODES AND AS <br />APPROVED BY MANUFACTURER'S SPECIFICATIONS ON ADJACENT MATERIAL. VAPOR BARRIER TO <br />BE INSTALLED ATALL EXTERIOR WALLS ON EXTERIOR SIDE OF SHEATHING. FULLY WRAP VAPOR <br />BARRIER TO INTERIOR ATALL OPENINGS. SEE DIAGRAM IN SPECIFICATIONS. <br />PROVIDE 30# TAR PAPER AS ROOF VAPOR BARRIER, OR AS APPROVED BY LOCAL CODES AND AS <br />APPROVED BY MANUFACTURER'S SPECIFICATIONS ON ADJACENT MATERIAL. VAPOR BARRIER TO <br />BE INSTALLED ATALL EXTERIOR WALLS ON EXTERIOR SIDE OF SHEATHING, FULLY WRAP VAPOR <br />BARRIER TO INTERIOR ATALL OPENINGS. <br />PROVIDE FLEXIBLE FLASHING ATALL OPENINGS AND ALL BUILDING CORNERS, WRAP ALL SIDES IN <br />ORDER FOR POSITIVE LAP TO OUTSIDE OF BUILDING. <br />CONTINUOUS METAL FLASHING ATALL JOINTS BETWEEN WALLS & ROOFS, VERTICALLY ON <br />CORNERS WHERE WALL MEETS WALL, AND HORIZONTALLY OVER JOINT BETWEEN WALL <br />SHEATHING AND CONCRETE FOOTER. FLASHING TO BE OVERLAPPED WITH VAPOR BARRIERS, <br />TYP. <br />CONTINUOUS METAL COPING AT TOP OF PARAPET WALLS. SEAL JOINTS WITH STANDING SEAM <br />SEAL OR APPROVED SEALANT. <br />INSULATE ENTIRE ENVELOPE PER CODE REQUIREMENTS. PROVIDE BATTS WITH INTEGRAL <br />VAPOR BARRIER AS SPECIFIED. PLASTIC VAPOR BARRIERS ARE NOT ALLOWED. SEE CODE <br />SUMMARY SHEETS IN SPECIFICATIONS. <br />JOINT SEALANT: SONOBORN SONOLASTIC 150 OR APPROVED ALTERNATE. COLOR 'SPECIAL <br />BRONZE' OR TO MATCH ADJACENT SURFACES. <br />FINISHES GENERAL NOTES: <br />PROVIDE FINISHES AS SPECIFIED. FOLLOW CODE REQUIREMENTS, MANUFACTURER'S <br />SPECIFICATIONS AND INSTALLATION/APPLICATION MANUALS. PROVIDE ARETE' DESING AND <br />OWNER WITH COPIES OF MANUFACTURER'S SPECIFICATIONS AND INSTALLATION/APPLICATION <br />MANUALS. <br />SOME FINISHES MAY REQUIRE SPECIAL STORAGE, TEMPERATURE, VENTILATION, INSTALLATION <br />MEANS OR INSTALLATION METHODS TO EITHER PROTECT THE MATERIAL, THE BUILDING, THE <br />ENVIRONMENT OR THE INSTALLERS FROM HARMFUL FUMES, DAMAGE OR OTHER LOSS. <br />PLUMBING & HVAC GENERAL NOTES <br />PLUMBING: <br />ALL SPECIFICATIONS AND INSTALLATION SPECIFICATIONS TO BE CHECKED AND VERIFIED WITH <br />MANUFACTURER BY GENERAL CONTRACTOR PRIOR TO PURCHASE OR INSTALLATION. <br />SEE PLAN FOR LOCATION OF GAS JETS, VALVES, HOSE BIBS, GAS AND WATER SERVICES. <br />PLUMBER TO BE RESPONSIBLE FOR OBTAINING UTILITY COMPANY APPROVAL OR WATER <br />SERVICE AND GAS METER LOCATION. <br />USE "PEX" FLEXIBLE PVC WATERAND PLUMBING LINES, WIRSBO, IPEX, OR APPROVED. <br />VENTS AND DRAINS TO BE ABS. <br />INSULATE ALL SUPPLY & WASTE PIPING FOR THERMAL AND ACOUSTIC. <br />TPlsI5 <br />PROVIDE BIDDER DESIGNED SYSTEM THAT PROVIDES HVAC (HEATING, VENTILATING AND AIR- <br />CONDITIONING) SERVICE WITH REQUIRED FRESH AIR QUOTAS PER CODE REQUIREMENTS. <br />SUBMIT DESIGN TO ARETE' DESING AND OWNER FOR APPROVAL PRIOR TO MANUFACTURE OR <br />INSTALLATION. <br />EXHAUST ALL VENTS AND FANS DIRECTLY TO THE OUTSIDE VIA METAL DUCTS. PROVIDE 90CFM <br />(MIN) 1.5 SONES OR LESS FANS TO PROVIDE 5 AIR EXCHANGES PER HOUR IN BATHS CONTAINING <br />TUB AND/OR SHOWER AND IN LAUNDRY ROOMS. <br />KITCHEN EXHAUST HOODS TO HAVE MAKE-UP AIR SUPPLYAND FIRE PROTECTION SYSTEM AS <br />REQUIRED AT EACH LOCATION. <br />ELECTRICAL GENERAL NOTES <br />ALL SPECIFICATIONS TO BE CHECKED AND VERIFIED WITH GENERAL CONTRACTOR. <br />LOCATION OF ALL OUTLETS, SWITCHES AND FIXTURES TO BE VERIFIED ON THE JOB SITE WITH <br />THE OWNER, ARETE' DESING AND GENERAL CONTRACTOR. ELECTRICIAN TO INSTALLALL LOW - <br />VOLTAGE, AS WELL AS LINE VOLTAGE. <br />HARDWIRE SMOKE DETECTOR TO UN -SWITCHED POWER. ALL DETECTORS TO HAVE INTEGRAL <br />BATTERY BACKUP. <br />ELECTRICIANS TO PROVIDE ELECTRICAL LAYOUT DRAWINGS, PANEL SCHEDULES, AND OBTAIN <br />ALL NECESSARY APPROVALS AS REQUIRED BY LOCAL BUILDING CODES, AND OBTAIN UTILITY <br />COMPANY APPROVAL OF METER LOCATION. <br />SECURITY REQUIREMENTS <br />ALL DOOR & WINDOW HARDWARE TO BE VERIFIED WITH MANUFACTURER, ARETE' DESING AND <br />OWNER PRIOR TO ORDERING. <br />CONTRACTOR TO VERIFY WITH OWNER REGARDING SECURITY SYSTEMS INTEGRATION. <br />SEE CONTRACT DOCUMENT PLANS & SPECIFICATIONS FOR ADDITIONAL NOTES <br />END OF GENERAL NOTES <br />WINDOW SCHEDULE <br />MARK <br />Library Part Name <br />SIZE <br />U VALUE <br />Home Story Name <br />WIDTH <br />HEIGHT <br />N3 <br />0861 OSAA Wn Horiz Slider <br />4'-0" <br />4'-0" <br />.30 <br />Basement <br />E1 <br />0861 OSAA Wn Horiz Slider <br />T-10" <br />T-10" <br />First Floor <br />E2 <br />0861 OSAA Wn Horiz Slider <br />3'-10" <br />T-10" <br />First Floor <br />E3 <br />0861 OSAA Wn Horiz Slider <br />2'-0" <br />4'-10" <br />First Floor <br />E4 <br />0861 OSHA Wn Horiz Slider <br />6'-0" <br />4'-10" <br />First Floor <br />E5 <br />0861 OSAA Wn Horiz Slider <br />2'-0" <br />4'-10" <br />First Floor <br />E6 <br />0861 OSAA Wn Horiz Slider <br />4'-0" <br />T-4" <br />First Floor <br />E7 <br />0861 OSAA Wn Horiz Slider <br />4'-10" <br />T-10" <br />First Floor <br />E8 <br />0861 OSAA Wn Horiz Slider <br />2'-0" <br />T-O" <br />First Floor <br />E8 <br />0861 OSAA Wn Horiz Slider <br />S-10" <br />3'-10" <br />First Floor <br />N 1 <br />08610SAA Wn Horiz Slider <br />4'-0" <br />4'-0" <br />.30 <br />Basement <br />N 2 <br />0861 OSAA Wn Horiz Slider <br />4'-0" <br />4'-0" <br />.30 <br />Basement <br />N 4 <br />0861 OSAA Wn Horiz Slider <br />4'-0" <br />4'-0" <br />.30 <br />Basement <br />DOOR AND FRAME SCHEDULE <br />MARK <br />Library Part Name <br />SIZE <br />U VALUE IF GLAZED <br />W <br />HT <br />CO <br />080060AA Dr Rect Opening <br />5'-0" <br />6-8" <br />CASED OPENING <br />Bas <br />D10 <br />08006AM Dr Swing <br />2'4" <br />6'-8" <br />Firs <br />D10 <br />08006AAA Dr Swing <br />2'-6" <br />6'-8" <br />Firs <br />D10 <br />RD07 Overhead <br />16'... <br />6'-8" <br />Bas <br />D11 <br />08006AAA Dr Swing <br />2'-0" <br />6-8" <br />Firs <br />D11 <br />08006AAA Dr Swing <br />2'-4" <br />6-8" <br />Firs <br />D11 <br />08006AAA Dr Swing <br />2'-6" <br />6-8" <br />Firs <br />D11 <br />08006BAB Or (2) BiFold <br />4'-0" <br />6-8" <br />Firs <br />D12 <br />08006BAB Dr (2) BiFold <br />4'-0" <br />6-8" <br />Firs <br />D13 <br />08006SAA Dr 21P Sliding <br />6'-0" <br />6'-8" <br />Firs <br />E1 <br />08006AAA Dr Swing <br />2'-8" <br />6-8" <br />LOCKING HARDWARE <br />Bas <br />E2 <br />080060AA Dr Rect Opening <br />2'-6" <br />6-8" <br />LOCKING HARDWARE <br />Bas <br />E3 <br />08006AAA Dr Swing <br />2'-6" <br />6%8" <br />LOCKING HARDWARE <br />Bas <br />NO <br />08006AAA Or Swing <br />2%8" <br />6-8" <br />LOCKING HARDWARE <br />Bas <br />N1 <br />08006AAA Or Swing <br />2'-8" <br />6'-8" <br />LOCKING HARDWARE <br />Bas <br />N3 <br />08006AAA Or Swing <br />2'-6" <br />6'-8" <br />Bas <br />N3 <br />08006BAA Or BiFold <br />2'-6" <br />6-8" <br />Bas <br />N4 <br />08006BAB Dr (2) BiFold <br />4'-0" <br />6' 8" <br />Bas <br />N5 <br />08006AAA Dr Swing <br />2'-6" <br />6%8" <br />LOCKING HARDWARE <br />Bas <br />N6 <br />08006AAA Or Swing <br />2%6" <br />6'-8" <br />LOCKING HARDWARE <br />Bas <br />N7 <br />08006BAA Or BiFold <br />T-O" <br />6'-8" <br />Bas <br />N8 <br />08006AAA Or Swing <br />2'-6" <br />6'-8" <br />LOCKING HARDWARE <br />Bas <br />N9 <br />08006BAB Dr (2) BiFold <br />4'-0" <br />6'-8" <br />Bas <br />N10 <br />08006BAB Or (2) BiFold <br />4'-0" <br />6'-8" <br />Bas <br />XTR1 <br />08006AAA Dr Swing <br />2'-8" <br />6'-8" <br />0.30; LOCKING HARDWARE; MIN 1 3/8" ... <br />Bas <br />XTR 2 <br />08006AAA Dr Swing <br />3'-0" <br />6'-8" <br />0.30; LOCKING HARDWARE <br />Bas <br />XTR 3 <br />08006AAA Dr Swing <br />T-O" <br />6'-8" <br />0.30; LOCKING HARDWARE <br />Firs <br />Prescriptive Energy Code Compliance for All Climate Zones in Washington <br />Project Information Contact Information <br />OWNER: GEBREMARIAM JOE LUCKEY <br />12041 22ND AVE NE <br />SEATTLE 98125 <br />This project will use the requirements of the Prescriptive Path below and incorporate the <br />the minimum values listed. In addition, based on the size of the structure, the appropriate <br />number of additional credits are checked as chosen by the permit applicant. <br />Authorized Representative Date <br />All (mate Zones <br />R-Value <br />U-Factor <br />Fenestration U-Facto <br />n/a <br />0.30 <br />Skylight U-Factor <br />n/a <br />0.50 <br />Glazed Fenestration SHGC , <br />n/a <br />n/a <br />Ceilingk <br />49 <br />0.026 <br />Wood Frame Wall9'"''" <br />21 int <br />0.056 <br />Mass Wall R-Value' <br />21/21 <br />0.056 <br />Floor <br />3011 <br />0.029 <br />Below Grade Walh'm <br />10/15/21 int + TB <br />0.042 <br />Slab'R-Value & Depth <br />10, 2 ft <br />n/a <br />'"Table R402.1.1 and Table R402.1.3 Footnotes included on Page Z. <br />Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 so as to achieve <br />the following minimum number of credits: <br />1. Small Dwelling Unit: 1.5 credits <br />0 Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration <br />area. Additions to existing building that are greater than 500 square feet of heated floor area but less than 1500 <br />square feet. <br />L12. Medium Dwelling Unit: 3.5 credits <br />All dwelling units that are not included in #1 or #3. Exception: Dwelling units serving R-2 occupancies shall <br />require 2.5 credits. <br />❑3. Large Dwelling Unit: 4.5 credits <br />Dwelling units exceeding 5000 square feet of conditioned floor area. <br />04. Additions less than 500 square feet: .5 credits <br />Table R406.2 Summary <br />Ontion Description <br />Credit(s) <br />1 a <br />Efficient Building Envelope 1 a <br />0.5 <br />1 b <br />Efficient Building Envelope lb <br />1.0 <br />1 c <br />Efficient Building Envelope 1 c <br />2.0 <br />1 d <br />Efficient Building Envelope 1 d <br />0.5 <br />2a <br />IXtr Leakage Control and Efficient Ventilation 2a <br />0.5 <br />2b <br />Air Leakage Control and Efficient Ventilation 2b <br />1.0 <br />2c <br />Air Leakage Control and Efficient Ventilation 2c <br />1.5 <br />3a <br />High Efficiency HVAC 3a <br />1.0 <br />3b <br />High Efficiency HVAC 3b <br />1.0 <br />3c <br />High Efficiency HVAC 3c <br />1.5 <br />3d <br />High Efficiency HVAC 3d <br />1.0 <br />4 <br />High Efficiency HVAC Distribution System <br />1.0 <br />5a <br />Efficient Water Heating 5a <br />0.5 <br />5b <br />Efficient Water Heating 5b <br />1.0 <br />5c <br />Efficient Water Heating 5c <br />1.5 <br />5d <br />Efficient Water Heating 5d <br />0.5 <br />6 <br />Renewable Electric Energy <br />0.5 <br />Total Credits <br />`Please refer to Table R406.2 for complete option descriptions <br />(E) EXTERIOR SHEATHING <br />1/2" LAG SCREW OR <br />THRU BOLT; STAGGERED <br />(E) 2x RIMMER <br />ro m <br />1 <br />FLASHING DETAIL <br />SCALE: 1 /2" = 1'-0" <br />El <br />11 <br />0 <br />El <br />*1200 kWh <br />)OUS FLASHING W/ <br />�E <br />1.5 <br />0.0 <br />1.50 <br />IATING OR MEMBRANE <br />RINE PLYWOOD <br />OISTS PER STR <br />DER BOARD <br />Nor <br />�, <br />DESIGNS <br />12041 22ND AVE NE <br />SEATTLE, WA. 98125 <br />206 365 2724 vice <br />206 499 2814 cell <br />luckeyjo@comcast.net <br />CONSULTANT STAMP <br />PROJECTINFO <br />PROJECT #:LEDER ADDITION <br />DRAWN BY: ARETE' <br />RELEASE DATE <br />MARK DATE DESCRIPTION <br />X XX.XX.XX XXXXXXXX <br />SET NOTES <br />PRINT DATE 1/7/2020 <br />PRINT TIME 12:36 PM <br />H <br />U <br />a <br />W <br />y <br />W <br />� <br />H <br />O <br />� <br />N <br />� <br />Z <br />li <br />Q� <br />a <br />W <br />Z <br />W <br />C9 <br />SHEET NUMBER <br />CITE' OF End Ti <br />EVIE ` E FOR - T <br />om <br />GEBREMARIAM ADDITION 20 DECEMBER 2019.pin; A 001 GENERAL NOTES; 100%; 1/7/2020 12:36 PM; NEW PLAN S <br />