Laserfiche WebLink
LUMINAIRE SCHEDULE **SEE FIXTURE CLARIFICATION NOTE #9 (NP) = NEW POLE (CBO) CONTROLLED BY OTHERS`* CONTRACTOR TO VERIFY MOUNTING ACCESSORIES BEFORE ORDERING** <br />SYMBOL QTY LABEL FIXTURE ARRANGEMENT TOTAL FIXTURE COUNT NEW POLE COUNT FIXTURE TYPE / MOUNTING / MANUFACTURER BUG RATING MOUNTING HEIGHT MOUNTING ACCESSORIES NOTES <br />3 <br />UB01 <br />SINGLE <br />3 <br />- <br />(UBO) CPY250-A-DM-F-20W-UL-WH-30K / CANOPY MOUNT / CREE <br />B1-U0-G1 <br />MATCH EXISTING <br />XA-BXCC9001 <br />REPLACE EXISTING FIXTURE <br />1 <br />UB02 <br />SINGLE <br />1 <br />- <br />(UBO) CPY250-A-DM-F-20W-UL-WH-30K / CANOPY MOUNT / CREE <br />B1-U0-G1 <br />9' AFG <br />XA-BXCC9001 <br />ADD NEW FIXTURE - MATCH EXISTING CANOPY HEIGHT <br />5 <br />UDX1 <br />SINGLE <br />5 <br />- <br />(UDX) CR6T-825L-30K-12-E26GU24 / CANOPY MOUNT / CREE <br />B1-U0-G0 <br />MATCH EXISTING <br />GR8 TRIM RING <br />REPLACE EXISTING FIXTURE <br />5 <br />UEM1 <br />SINGLE <br />5 <br />- <br />(UEM) ZR24C-40L-30K-10V-FD (LED 2x4) / CANOPY MOUNT / CREE <br />B2-U0-G1 <br />MATCH EXISTING <br />- <br />REPLACE EXISTING FIXTURE <br />2 <br />UU1 <br />SINGLE <br />2 <br />- <br />AME-2-L-T5-144LC-5-3K-UNV-BOA6-BZ / POLE MOUNT / VISIONAIRE <br />B4-UO-G2 <br />MATCH EXISTING <br />- <br />REPLACE EXISTING FIXTURE <br />— <br />1 <br />UU2 <br />SINGLE <br />1 <br />- <br />AME-2-L-T4-72LC-5-3K-UNV-BOA6-BZ / POLE MOUNT / VISIONAIRE <br />B2-UO-G3 <br />MATCH EXISTING <br />- <br />REPLACE EXISTING FIXTURE <br />- <br />1 <br />UU3 <br />SINGLE <br />1 <br />- <br />AME-2-L-T4-72LC-3-3K-UNV-BOA6-BZ / POLE MOUNT / VISIONAIRE <br />B2-UO-G2 <br />MATCH EXISTING <br />- <br />REPLACE EXISTING FIXTURE <br />2 <br />UU4 <br />j DOUBLE (2@90°) <br />4 <br />- <br />AME-2-L-T4-72LC-5-3K-UNV-BOA6-BZ / POLE MOUNT / VISIONAIRE <br />B2-UO-G3 <br />MATCH EXISTING <br />- <br />REPLACE EXISTING FIXTURE <br />2 <br />UU5 (NEW POLE) <br />SINGLE <br />2 <br />2 <br />AME-2-L-T4-144LC-5-3K-UNV-BOA6-BZ / POLE MOUNT / VISIONAIRE <br />B3-UO-G4 <br />22' -6" AFG <br />- <br />ADD NEW POLE AND FIXTURE <br />1 <br />RE1 <br />SINGLE <br />1 <br />- <br />EXISTING CANOPY FIXTURE <br />- <br />- <br />- <br />REMOVE AND PATCH <br />2 <br />RG1 <br />SINGLE <br />2 <br />- <br />EXISTING CANOPY FIXTURE <br />- <br />- <br />- <br />REMOVE AND PATCH <br />7 <br />RH1 <br />SINGLE <br />7 <br />- <br />EXISTING CANOPY FIXTURE <br />- <br />- <br />- <br />REMOVE AND PATCH <br />2 <br />R11 <br />SINGLE <br />� 2 <br />- <br />EXISTING WALL FIXTURE <br />i <br />- <br />- <br />- <br />REMOVE AND PATCH <br />y <br />1 <br />YA1 <br />SINGLE <br />1 <br />- <br />EXISTING POLE FIXTURE <br />- <br />! - <br />- <br />OUT OF SCOPE <br />1 <br />YB1 <br />! SINGLE <br />1 <br />- <br />EXISTING POLE FIXTURE <br />- <br />- <br />- <br />OUT OF SCOPE <br />----- -------- -- -- <br />- <br />- - <br />---- --- -- - ----- <br />---_ <br />1 <br />Y132 <br />SINGLE <br />EXISTING POLE FIXTURE <br />- <br />OUT OF SCOPE <br />Bank A <br />4VIOSM <br />BLUE = NEW FIXTURE <br />GREEN = EXISTING FIXTURE LOCATION TO BE REPLACED <br />ORANGE = EXISTING FIXTURE TO REMAIN <br />TURQUOISE = FIXTURE TO BE REMOVED <br />PINK = REPLACE WITH NEW POLE AT NEW HEIGHT <br />REVISION REVISED <br />NO. DESCRIPTION R.4 <br />G"r? <br />Facility Analysis t Engineering <br />Silver Lake <br />WA4-138 <br />1803 112th St SE <br />Everett, WA <br />LUMINAIRE SCHEDULE <br />DESIGN BY: DRAWN BY: <br />JDH BRW <br />REVIEWED BY: APPROVED BY: <br />NOTE: THIS LIGHTING PLAN ILLUSTRATES ILLUMINATION LEVELS CALCULATED FROM MLP KRIVI <br />LABORATORY DATA UNDER CONTROLLED CONDITIONS IN ACCORDANCE WITH <br />ILLUMINATING ENGINEERING SOCIETY OF NORTH AMERICA (IESNA) APPROVED SHEET NO. <br />METHODS. ACTUAL SITE ILLUMINATION LEVELS AND PERFORMANCE OF LUMINARIES <br />MAY VARY DUE TO VARIATIONS IN WEATHER, ELECTRICAL VOLTAGE, TOLERANCE IN <br />LAMPS AND OTHER RELATED VARIABLE FIELD CONDITIONS. LU=2 <br />