My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4016 HOYT AVE 2022-02-17
>
Address Records
>
HOYT AVE
>
4016
>
4016 HOYT AVE 2022-02-17
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/17/2022 7:43:15 AM
Creation date
8/19/2021 8:08:10 AM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
4016
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3/22/2024 <br />9:31:15AM <br />City of Everett <br />INSPECTION ACTIVITY REPORT <br />age <br />11/13/2019 11/13/2019 <br />12/17/2019 12/17/2019 <br />12/17/2019 12/17/2019 <br />12/31 /2019 12/31 /2019 <br />MECH 04-ROUGH SDP <br />IN <br />MECH 04-ROUGH SDP <br />IN <br />CORRECTION <br />APPROVAL eTRAKiT Inspection <br />Request <br />BLDG KMK PARTIAL APPR see notes <br />08-FRAMING <br />BLDG DWF PARTIAL APPR eTRAKiT Inspection <br />08-FRAMING Request <br />11/12/2019 10:27 AM Oluseyi Oluwole <br />Preferred 9am to 1lam inspection. <br />Contact Name: Oluseyi Oluwole <br />Site Address: 4016 HOYT AVE <br />Phone:2063709445 <br />e-Mail: seyi_oluwole@msn.com <br />(11/13/2019 3:05 PM SDP) <br />1) Bathroom exhaust, dryer and stove <br />exhaust cannot terminate on the side of the <br />house due to the close property lines. The <br />main floor venting can terminate through <br />the roof as long as the termination is 4 feet <br />horizontally from the property lines. <br />2) You cannot penetrate the floor ceiling <br />assembly of the lower unit without using an <br />approved fire protection method. Inspector <br />left a tip sheet for damper and horizontal <br />shaft requirements. <br />3) Dryer and Stove exhaust cannot have a <br />fire damper installed (only bath exhaust). <br />4) Stove exhaust must be 6" min. duct, <br />solid ducting and no flex duct. <br />12/16/2019 10:40 AM Oluseyi Oluwole <br />Prefer morning inspection. Thanks for all <br />your help. <br />Contact Name: Oluseyi Oluwole <br />Site Address: 4016 HOYT AVE <br />Phone:2063709445 <br />e-Mail: seyi_oluwole@msn.com <br />12/16/2019 11:00 AM Oluseyi Oluwole <br />preferred morning inspection between <br />Contact Name: Oluseyi Oluwole <br />Site Address: 4016 HOYT AVE <br />Phone:2063709445 <br />e-Mail: seyi_oluwole@msn.com <br />(12/17/2019 12:39 PM KMK) <br />Lower floor: <br />1. Fire block both vertical and horizontal <br />every 10' <br />2. Air seal <br />3. Provide fix for over drilled studs and <br />plates at plumbing <br />Upper floor: ok to insulate <br />12/30/2019 11:14 AM Oluseyi Oluwole <br />Contact Name: Oluseyi Oluwole <br />Site Address: 4016 HOYT AVE <br />Phone:2063709445 <br />e-Mail: seyi_oluwole@msn.com <br />(12/31/2019 11:33 AM DWF) <br />Approved subject to completing air seal 10' <br />x 10' area or floor / ceiling and post/ beam <br />positive connection. <br />Will inspect corrections on insulation <br />inspection. <br />INSP 12 C YS TE S <br />
The URL can be used to link to this page
Your browser does not support the video tag.