Laserfiche WebLink
Prescriptive Path, pg. 2 ENV -PRESCRIPTIVE <br />2015 WSEC Compliance Forms for Commercial Buildings including R2, R3, & R4 over 3 stories and all R1 Revised Oct 2017 <br />Project Title: Compass Health Supportive Housing Date 07/11/2019 <br />Fenestration Area as % gross above -grade wall area 21.4% Max. Target: 30.0% For Building Department Use <br />Skylight Area as % gross roof area 0.0% Max. Target: 5.0% <br />If vertical fenestration or skylight area exceeds maximum allowed per C402.4.1, then the project must <br />comply via Component Performance and provide ENV-UA and ENV-SHGC forms. <br />R-Value Method for U-Factor/F-Factor Method for <br />Building Component Prescriptive Compliance Prescriptive Compliance <br />Perim. Ins. Full Slab Cl <br />Provide plan/detail # of assembly and description R-Value R-Value F-Factor F-Factor Source10 <br />FC1/A5.4 & 1,2,3/A7.1 - R10 for 24" from top of slab R10 Appendix A <br />c <br />c <br />o � <br />m d <br />cp _ <br />Ins. Assembly 11 <br />Provide ID from door schedule and description R-Value U-Factor U-Factor Source <br />m <br />o c Door Schedule A8.2 (001, 010B, 122B, 139B) - <br />0 3 insulated steel door 0.370 Appendix A <br />m <br />O z <br />O <br />Factor(PF) <br />(N or <br />Provide ID from window schedule and description <br />if applicablet2 <br />SEW)13 <br />Window Schedule A8.5 (A, B, C, D, E, F, H, K) <br />Window Schedule A8.5 (G1, G2, G3, G4, G4, J1, J2) <br />N/A <br />SEW <br />o <br />Window Schedule A8.5 (A, B, C, D, E, F, H, K) <br />N/A <br />N <br />Z <br />Window Schedule A8.5 (G1, G2, G3, G4, G4, J1, J2) <br />N/A <br />SEW <br />a� <br />w <br />Storefront Schedule A8.5 (S5, S7, S8) <br />N/A <br />SEW <br />a2 <br />Storefront Schedule A8.5 (S3, S4, S6) <br />N/A <br />SEW <br />2 <br />Storefront Schedule A8.5 (S1, S2, S3) <br />N/A <br />N <br />o. <br />0 <br />Assembly <br />Assembly <br />SHGC14 <br />U-Factor <br />0.53 <br />0.40 <br />0.26 <br />0.53 <br />0.28 <br />0.40 <br />0.26 <br />0.40 <br />0.60 <br />0.40 <br />0.38 <br />0.53 <br />0.38 <br />U-Factor Source14 <br />Windows - Endurance <br />Windows-- Endurance <br />Windows - Endurance <br />Windows - Endurance <br />C303.1.3 <br />C303.1.3 <br />ml I I I <br />bath a slab-on-arade or exposed floor. this floor shall be thermally broken from the surrounding floor area with the same amount of insulation as re <br />N <br />� <br />� <br />rn <br />a <br />>, <br />T <br />� <br />Y <br />cn <br />— <br />Q <br />Miscellaneous - Ketr1 eratect 5 aces <br />Ins. Assembly <br />Provide plan/detail # of assembly and description R-Value U-Factor U-Factor Source <br />a� <br />o <br />LL LL <br />Cooler / Double Triple Pane Inert Gas Heat Reflective <br />Provide ID from window schedule and description Freezer Pane Glass Glass Filled Treated Glass <br />`o 0 <br />c <br />c <br />•N c <br />N <br />W <br />